64 resultados para Rapid assessment method
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Objective: To estimate the prevalence of blindness in the elderly population of Campinas, Brazil, and to describe the coverage and quality of cataract surgery services in the area. Methods: A brief assessment of cataract surgery services (using the RACSS (Rapid Assessment of Cataract Surgical Services Method) was conducted using random cluster sampling, with a sample composed of 60 clusters of 40 people aged 50 years or older. Visual acuity (VA) was measured and the lens status observed by direct visual ophthalmoscopy. From the selected sample of 2,400 subjects, 92.67% were examined. Results: Blindness (VA 3/60 with available correction) was found in 1.98 % (2.03 % among male subjects, and 1.94 % among female subjects). The prevalence of blindness varied with age, from 0.2%, in the group from 50 to 54 years, to 7.2% in those above 80. Cataract was the main cause of blindness (40.2%) followed by suspected posterior segment disorders (18.2%), diabetic retinopathy (15.9%), and glaucoma (11.4%). The cataract surgical coverage was of 93% (VA 3/60) and 82.18% when the criterion was VA 6/60 in the best eye. The main reasons the subjects did not receive surgical treatment were: fear of undergoing surgery, 11.1%; lack of awareness about the condition, 16.7%; waiting for maturity, 16.7%; and contraindication to surgery, 44.4%. Conclusion: Cataract is the major cause of blindness in Campinas. Education on eye diseases, their prevention and treatment must become part of the city`s public healthcare policies.
Resumo:
The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Objective Underreporting of energy intake is prevalent in food surveys, but there is controversy about which dietary assessment method provides greater underreporting rates. Our objective is to compare validity of self-reported energy intake obtained by three dietary assessment methods with total energy expenditure (TEE) obtained by doubly labeled water (DLW) among Brazilian women. Design We used a cross-sectional study. Subjects/setting Sixty-five females aged 18 to 57 years (28 normal-weight, 10 over-weight, and 27 obese) were recruited from two universities to participate. Main outcome measures TEE determined by DLW, energy intake estimated by three 24-hour recalls, 3-day food record, and a food frequency questionnaire (FFQ). Statistical analyses performed Regression and analysis of variance with repeated measures compared TEE and energy intake values, and energy intake-to-TEE ratios and energy intake-TEE values between dietary assessment methods. Bland and Altman plots were provided for each method. chi(2) test compared proportion of underreporters between the methods. Results Mean TEE was 2,622 kcal (standard deviation [SD] =490 kcal), while mean energy intake was 2,078 kcal (SD=430 kcal) for the diet recalls; 2,044 kcal (SD=479 kcal) for the food record and 1,984 kcal (SD=832 kcal) for the FFQ (all energy intake values significantly differed from TEE; P<0.0001). Bland and Altman plots indicated great dispersion, negative mean differences between measurements, and wide limits of agreement. Obese subjects underreported more than normal-weight subjects in the diet recalls and in the food records, but not in the FFQ. Years of education, income and ethnicity were associated with reporting accuracy. Conclusions The FFQ produced greater under- and overestimation of energy intake. Underreporting of energy intake is a serious and prevalent error in dietary self-reports provided by Brazilian women, as has been described in studies conducted in developed countries.
Resumo:
Conjugated linoleic acids (CLAs) are a group of linoleic acid isomers that are naturally found in food products originating from ruminants (meat and dairy). These acids have received special attention in recent years due to their potential human health benefits. Research efforts have been proposed to increase the CLA content in beef to improve public health. However, because there are more than 30 million beef cattle used each year by the American food industry, it will be necessary to ensure their content in a large number of samples. Therefore, it is important to have an inexpensive and rapid analytical method to measure CLA content in food products. Because gas chromatography (GC), a current popular method for measuring CLAs, is slow, this paper describes a nuclear magnetic resonance spectroscopy ((1)H NMR) method that is potentially >10 times faster than the GC method. Analyses show a correlation coefficient of 0.97, indicating the capacity of NMR to quantify the CLA content in beef samples. Furthermore, the method proposed herein is simple and does not require sophisticated sample preparation.
Resumo:
The aim of this study was to compare different treatments for dentin hypersensitivity in a 6-month follow-up. One hundred and one teeth exhibiting non carious cervical lesions were selected. The assessment method used to quantify sensitivity was the cold air syringe, recorded by the visual analogue scale (VAS), prior to treatment (baseline), immediately after topical treatment, after 1 week, 1, 3 and 6 months. Teeth were randomly assigned to five groups (n = 20): G1: Gluma Desensitizer (GD); G2: Seal&Protect (SP); G3: Oxa-gel (OG); G4: Fluoride (F); G5: Low intensity laser-LILT (660 nm/3.8 J/cm²/15 mW). Analysis was based on the non-parametric Kruskal-Wallis test that demonstrated statistical differences immediately after the treatment (p = 0.0165). To observe the individual effects of each treatment, data was submitted to Friedman test. It was observed that GD and SP showed immediate effect after application. Reduction in the pain level throughout the six-month follow-up was also observed. In contrast, LILT presented a gradual reduction of hypersensitivity. OG and F showed effects as of the first and third month respectively. It can be concluded that, after the 6-month clinical evaluation, all therapies showed lower VAS sensitivity values compared with baseline, independently of their different modes of action.
Resumo:
The performance of laser-induced breakdown spectrometry (LIBS) for the determination of Ba, Cd, Cr and Pb in toys has been evaluated by using a Nd:YAG laser operating at 1064 nm and an Echelle spectrometer with intensified charge-coupled device detector. Samples were purchased in different cities of Sao Paulo State market and analyzed directly without sample preparation. Laser-induced breakdown spectrometry experimental conditions (number of pulses, delay time. integration time gate and pulse energy) were optimized by using a Doehlert design. Laser-induced breakdown spectrometry signals correlated reasonably well with inductively coupled plasma optical emission spectrometry (ICP OES) concentrations after microwave-assisted acid digestion of selected samples. Thermal analysis was used for polymer identification and scanning electron microscopy to Visualize differences in crater geometry of different polymers employed for toy fabrication. Results indicate that laser-induced breakdown spectrometry can be proposed as a rapid screening method for investigation of potentially toxic elements in toys. The unique application of laser-induced breakdown spectrometry for identification of contaminants in successive layers of ink and polymer is also demonstrated. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Objective To assess the validity and the reliability of the Portuguese version of the Delirium Rating Scale-Revised-98 (DRS-R-98). Methods The scale was translated into Portuguese and back-translated into English. After assessing its face validity, five diagnostic groups (n = 64; delirium, depression, dementia, schizophrenia and others) were evaluated by two independent researchers blinded to the diagnosis. Diagnosis and severity of delirium as measured by the DRS-R-98 were compared to clinical diagnosis, Mini-Mental State Exam, Confusion Assessment Method, and Clinical Global Impressions scale (CGI). Results Mean and rnedian DRS-R-98 total scores significantly distinguished delirium from the other groups (p < 0.001). Inter-rater reliability (ICC between 0.9 and 1) and internal consistency (alpha = 0.91) were very high. DRS-R-98 severity scores correlated highly with the CGI. Mean DRS-R-98 severity scores during delirium differed significantly (p < 0.01) from the post-treatment values. The area under the curve established by ROC analysis was 0.99 and using the cut-off Value of 20 the scale showed sensitivity and specificity of 92.6% and 94.6%, respectively. Conclusion The Portuguese version of the DRS-R-98 is a valid and reliable measure of delirium that distinguishes delirium from other disorders and is sensitive to change in delirium severity, which may be of great value for longitudinal studies. Copyright (c) 2007 John Wiley & Sons, Ltd.
Resumo:
Background/Objectives: We applied three dietary assessment methods and aimed at obtaining a set of physical, social and psychological variables that can discriminate those individuals who did not underreport (`never under-reporters`), those who underreported in one dietary assessment method (`occasional under-reporters`) and those who underreported in two or three dietary assessment methods (`frequent under-reporters`). Participants/Methods: Sixty-five women aged 18-57 years were recruited for this study. Total energy expenditure was determined by doubly labelled water, and energy intake was estimated by three 24-h diet recalls, 3-day food records and a food frequency questionnaire. A multiple discriminant analysis was used to identify which of those variables better discriminated the three groups: body mass index (BMI), income, education, social desirability, nutritional knowledge, dietary restraint, physical activity practice, body dissatisfaction and binge-eating symptoms. Results: Twenty-three participants were `never under-reporters`. Twenty-four participants were `occasional under-reporters` and 18 were `frequent under-reporters`. Four variables entered the discriminant model: income, BMI, social desirability and body dissatisfaction. According to potency indices, income contributed the most to the total discriminant power, followed in decreasing order by social desirability score, BMI and body dissatisfaction. Income, social desirability and BMI were the characteristics that mainly separated the `never under-reporters` from the under-reporters (occasional or frequent). Body dissatisfaction better discriminated the `occasional under-reporters` from the `frequent under-reporters`. Conclusions: `Frequent under-reporters` have a greater BMI, social desirability score, body dissatisfaction score and lower income. These four variables seemed to be able to discriminate individuals who are more prone to systematic under reporting. European Journal of Clinical Nutrition (2009) 63, 1192-1199; doi:10.1038/ejcn.2009.54; published online 15 July 2009
Resumo:
Aeromonas species are widely distributed in aquatic environments and recent studies include the genus in the emergent pathogens group because of its frequent association with local and systemic infections in immunocompetent humans. Aiming to search for virulence genes in environmental strains of Aeromonas hydrophila and Aeromonas jandaei, we designed specific primers to detect act/hly A/aer complex and alt genes. Primers described elsewhere were used to detect ast. Eighty-seven strains previously identified using phenotypic and genotypic tests as A. hydrophila (41) and A. jandaei (46) were analysed for the presence of the virulence genes using PCR. DNA fragments of expected size were purified and directly sequenced. Among the 41 strains of A. hydrophila 70.7% (29), 97.6% (40) and 26.8% (11) possessed act/hly A/aer complex, ast and alt genes, respectively. Among the 46 strains of A. jandaei, 4.4% (2), 0% (0) and 32.6% (15) were positive for act/hly A/aer complex, ast and alt genes, respectively. Sequencing allowed for the confirmation of amplified products using BLAST. The present work proposes a specific and rapid diagnostic method to detect the main virulence determinants of Aeromonas, a genus potentially pathogenic to humans.
Resumo:
OBJECTIVE: The aim of the present study was to use facial analysis to determine the effects of rapid maxillary expansion (RME) on nasal morphology in children in the stages of primary and mixed dentition, with posterior cross-bite. MATERIAL AND METHODS: Facial photographs (front view and profile) of 60 patients in the pre-expansion period, immediate post-expansion period and one year following rapid maxillary expansion with a Haas appliance were evaluated on 2 occasions by 3 experienced orthodontists independently, with a 2-week interval between evaluations. The examiners were instructed to assess nasal morphology and had no knowledge regarding the content of the study. Intraexaminer and interexaminer agreement (assessed using the Kappa statistic) was acceptable. RESULTS: From the analysis of the mode of the examiners' findings, no alterations in nasal morphology occurred regarding the following aspects: dorsum of nose, alar base, nasal width of middle third and nasal base. Alterations were only detected in the nasolabial angle in 1.64% of the patients between the pre-expansion and immediate post-expansion photographs. In 4.92% of the patients between the immediate post-expansion period and 1 year following expansion; and in 6.56% of the patients between the pre-expansion period and one year following expansion. CONCLUSIONS: RME performed on children in stages of primary and mixed dentition did not have any impact on nasal morphology, as assessed using facial analysis.
Resumo:
A simple and fast capillary zone electrophoresis (CZE) method has been developed and validated for quantification of a non-nucleoside reverse transcriptase inhibitor (NNRTI) nevirapine, in pharmaceuticals. The analysis was optimized using 10 mmol L-1 sodium phosphate buffer pH 2.5, +25 kV applied voltage, hydrodynamic injection 0.5 psi for 5 s and direct UV detection at 200 µm. Diazepam (50.0 µg mL-1) was used as internal standard. Under these conditions, nevirapine was analyzed in approximately less than 2.5 min. The analytical curve presented a coefficient of correlation of 0.9994. Limits of detection and quantification were 1.4 µg mL-1 and 4.3 µg mL-1, respectively. Intra- and inter-day precision expressed as relative standard deviations were 1.4% and 1.3%, respectively and the mean recovery was 100.81%. The active pharmaceutical ingredient was subjected to hydrolysis (acid, basic and neutral) and oxidative stress conditions. No interference of degradation products and tablet excipients were observed. This method showed to be rapid, simple, precise, accurate and economical for determination of nevirapine in pharmaceuticals and it is suitable for routine quality control analysis since CE offers benefits in terms of quicker method development and significantly reduced operating costs.
Resumo:
P>Soil bulk density values are needed to convert organic carbon content to mass of organic carbon per unit area. However, field sampling and measurement of soil bulk density are labour-intensive, costly and tedious. Near-infrared reflectance spectroscopy (NIRS) is a physically non-destructive, rapid, reproducible and low-cost method that characterizes materials according to their reflectance in the near-infrared spectral region. The aim of this paper was to investigate the ability of NIRS to predict soil bulk density and to compare its performance with published pedotransfer functions. The study was carried out on a dataset of 1184 soil samples originating from a reforestation area in the Brazilian Amazon basin, and conventional soil bulk density values were obtained with metallic ""core cylinders"". The results indicate that the modified partial least squares regression used on spectral data is an alternative method for soil bulk density predictions to the published pedotransfer functions tested in this study. The NIRS method presented the closest-to-zero accuracy error (-0.002 g cm-3) and the lowest prediction error (0.13 g cm-3) and the coefficient of variation of the validation sets ranged from 8.1 to 8.9% of the mean reference values. Nevertheless, further research is required to assess the limits and specificities of the NIRS method, but it may have advantages for soil bulk density predictions, especially in environments such as the Amazon forest.
Resumo:
The aim of this work is to propose a biomonitoring method for the simultaneous determination of Cd and Pb in whole blood by simultaneous electrothermal atomic absorption spectrometry for assessment of environmental levels. A volume of 200 mu L of whole blood was diluted in 500 mu L of 0.2% (w v(-1)) Triton(R) X-100 + 2.0% (v v(-1)) HNO3. Trichloroacetic acid was added for protein precipitation and the supernatant analyzed. A mixture of 250 mu g W + 200 mu g Rh as permanent and 2.0% (w v(-1)) NH4H2PO4 as co-injected modifiers were used. Characteristic masses and limits of detections (n = 20, 3s) for Cd and Pb were 1.26 and 33 pg and 0.026 mu g L-1 and 0.65 mu g L-1, respectively. Repeatability ranged from 1.8 to 6.8% for Cd and 1.2 to 1.7% for Pb. The trueness of method was checked by the analysis of three Reference Materials: Lyphocheck(R) Whole Blood Metals Control level 1 and Seronorm(TM) Trace Elements in Whole Blood levels 1 and 2. The found concentrations presented no statistical differences at the 95% confidence level. Blood samples from 40 volunteers without occupational exposure were analyzed and the concentrations ranged from 0.13 to 0.71 mu g L-1 (0.32 +/- 0.19 mu g L-1) for Cd and 9.3 to 56.7 mu g L-1 (25.1 +/- 10.8 mu g L-1) for Pb. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
A capillary electrophoresis method for organic acids in wine was developed and validated. The optimal electrolyte consisted of 10 mmol/L 3,5-dinitrobenzoic acid (DNB) at pH 3.6 containing 0.2 mmol/L cetyltrimethylammonium bromide as flow reverser. DNB was chosen because it has an effective mobility similar to the organic acids under investigation, good buffering capacity at pH 3.6, and good chromophoric characteristics for indirect UV-absorbance detection at 254 nm. Sample preparation involved dilution and filtration. The method showed good performance characteristics: Linearity at 6 to 285 mg/L (r > 0.99); detection and quantification limits of 0.64 to 1.55 and 2.12 to 5.15 mg/L, respectively; separation time of less than 5.5 min. Coefficients of variation for ten injections were less than 5% and recoveries varied from 95% to 102%. Application to 23 samples of Brazilian wine confirmed good repeatability and demonstrated wide variation in the organic acid concentrations. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
OBJECTIVE: This study evaluated the influence of metallic dental artifacts on the accuracy of simulated mandibular lesion detection by using multislice technology. MATERIAL AND METHODS: Fifteen macerated mandibles were used. Perforations were done simulating bone lesions and the mandibles were subjected to axial 16 rows multislice CT images using 0.5 mm of slice thickness with 0.3 mm interval of reconstruction. Metallic dental restorations were done and the mandibles were subjected again to CT in the same protocol. The images were analyzed to detect simulated lesions in the mandibles, verifying the loci number and if there was any cortical perforation exposing medullar bone. The analysis was performed by two independent examiners using e-film software. RESULTS: The samples without artifacts presented better results compared to the gold standard (dried mandible with perforations). In the samples without artifacts, all cortical perforation were identified and 46 loci were detected (of 51) in loci number analysis. Among the samples with artifacts, 12 lesions out of 14 were recognized regarding medullar invasion, and 40 out of 51 concerning loci number. The sensitivity in samples without artifacts was 90% and 100% regarding loci number and medullar invasion, respectively. In samples with artifacts, these values dropped to 78% and 86%, respectively. The presence of metallic restorations affected the sensitivity values of the method, but the difference was not significant (p>0.05). CONCLUSIONS: Although there were differences in the results of samples with and without artifacts, the presence of metallic restoration did not lead to misinterpretation of the final diagnosis. However, the validity of multislice CT imaging in this study was established for detection of simulated mandibular bone lesions.