170 resultados para Positioning precision
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
The problem of projecting multidimensional data into lower dimensions has been pursued by many researchers due to its potential application to data analyses of various kinds. This paper presents a novel multidimensional projection technique based on least square approximations. The approximations compute the coordinates of a set of projected points based on the coordinates of a reduced number of control points with defined geometry. We name the technique Least Square Projections ( LSP). From an initial projection of the control points, LSP defines the positioning of their neighboring points through a numerical solution that aims at preserving a similarity relationship between the points given by a metric in mD. In order to perform the projection, a small number of distance calculations are necessary, and no repositioning of the points is required to obtain a final solution with satisfactory precision. The results show the capability of the technique to form groups of points by degree of similarity in 2D. We illustrate that capability through its application to mapping collections of textual documents from varied sources, a strategic yet difficult application. LSP is faster and more accurate than other existing high-quality methods, particularly where it was mostly tested, that is, for mapping text sets.
Resumo:
OBJECTIVE: The aim of the present study was to verify the torque precision of metallic brackets with MBT prescription using the canine brackets as the representative sample of six commercial brands. MATERIAL AND METHODS: Twenty maxillary and 20 mandibular canine brackets of one of the following commercial brands were selected: 3M Unitek, Abzil, American Orthodontics, TP Orthodontics, Morelli and Ortho Organizers. The torque angle, established by reference points and lines, was measured by an operator using an optical microscope coupled to a computer. The values were compared to those established by the MBT prescription. RESULTS: The results showed that for the maxillary canine brackets, only the Morelli torque (-3.33º) presented statistically significant difference from the proposed values (-7º). For the mandibular canines, American Orthodontics (-6.34º) and Ortho Organizers (-6.25º) presented statistically significant differences from the standards (-6º). Comparing the brands, Morelli presented statistically significant differences in comparison with all the other brands for maxillary canine brackets. For the mandibular canine brackets, there was no statistically significant difference between the brands. CONCLUSIONS: There are significant variations in torque values of some of the brackets assessed, which would clinically compromise the buccolingual positioning of the tooth at the end of orthodontic treatment.
Resumo:
Some factors complicate comparisons between linkage maps from different studies. This problem can be resolved if measures of precision, such as confidence intervals and frequency distributions, are associated with markers. We examined the precision of distances and ordering of microsatellite markers in the consensus linkage maps of chromosomes 1, 3 and 4 from two F 2 reciprocal Brazilian chicken populations, using bootstrap sampling. Single and consensus maps were constructed. The consensus map was compared with the International Consensus Linkage Map and with the whole genome sequence. Some loci showed segregation distortion and missing data, but this did not affect the analyses negatively. Several inversions and position shifts were detected, based on 95% confidence intervals and frequency distributions of loci. Some discrepancies in distances between loci and in ordering were due to chance, whereas others could be attributed to other effects, including reciprocal crosses, sampling error of the founder animals from the two populations, F(2) population structure, number of and distance between microsatellite markers, number of informative meioses, loci segregation patterns, and sex. In the Brazilian consensus GGA1, locus LEI1038 was in a position closer to the true genome sequence than in the International Consensus Map, whereas for GGA3 and GGA4, no such differences were found. Extending these analyses to the remaining chromosomes should facilitate comparisons and the integration of several available genetic maps, allowing meta-analyses for map construction and quantitative trait loci (QTL) mapping. The precision of the estimates of QTL positions and their effects would be increased with such information.
Resumo:
The noise, vibration and harshness (NVH) performance of passenger vehicles strongly depends on the fluid-structure interaction between the air in the vehicle cavity and the sheet metal structure of the vehicle. Most of the noise and vibration problems related to this interaction come from resonance peaks of the sheet metal, which are excited by external forces (road, engine, and wind). A reduction in these resonance peaks can be achieved by applying bitumen damping layers, also called deadeners, in the sheet metal. The problem is where these deadeners shall be fixed, which is usually done in a trial-and-error basis. In this work, one proposes the use of embedded sensitivity to locate the deadeners in the sheet metal of the vehicle, more specifically in the vehicle roof. Experimental frequency response functions (FRFs) of the roof are obtained and the data are processed by adopting the embedded sensitivity method, thus obtaining the sensitivity of the resonance peaks on the local increase in damping due to the deadeners. As a result, by examining the sensitivity functions, one can find the optimum location of the deadeners that maximize their effect in reducing the resonance peaks of interest. After locating the deadeners in the optimum positions, it was possible to verify a strong reduction in resonance peaks of the vehicle roof, thus showing the efficiency of the procedure. The main advantage of this procedure is that it only requires FRF measurements of the vehicle in its original state not needing any previous modification of the vehicle structure to find the sensitivity functions. [DOI: 10.1115/1.4000769]
Resumo:
This paper presents a proposal for a Quality Management System for a generic GNSS Surveying Company as an alternative for management and service quality improvements. As a result of the increased demand for GNSS measurements, a large number of new or restructured companies were established to operate in that market. Considering that GNSS surveying is a new process, some changes must be performed in order to accommodate the old surveying techniques and the old fashioned management to the new reality. This requires a new management model that must be based on a well-described procedure sequence aiming at the Total Management Quality for the company. The proposed Quality Management System was based on the requirements of the Quality System ISO 9000:2000, applied to the whole company, focusing on the productive process of GNSS surveying work.
Resumo:
Chloride attack in marine environments or in structures where deicing salts are used will not always show profiles with concentrations that decrease from the external surface to the interior of the concrete. Some profiles show an increase in chloride concentrations from when a peak is formed. This type of profile must be analyzed in a different way from the traditional model of Fick`s second law to generate more precise service life models. A model for forecasting the penetration of chloride ions as a function of time for profiles having formed a peak. To confirm the efficiency of this model, it is necessary to observe the behavior of a chloride profile with peak in a specific structure over a period of time. To achieve this, two chloride profiles with different ages (22 and 27 years) were extracted from the same structure. The profile obtained from the 22-year sample was used to estimate the chloride profile at 27 years using three models: a) the traditional model using Fick`s second law and extrapolating the value of C(S)-external surface chloride concentration; b) the traditional model using Fick`s second law and shifting the x-axis to the peak depth; c) the previously proposed model. The results from these models were compared with the actual profile measured in the 27-year sample and the results were analyzed. The model was presented with good precision for this study of case, requiring to be tested with other structures in use.
Resumo:
Vessel dynamic positioning (DP) systems are based on conventional PID-type controllers and an extended Kalman filter. However, they present a difficult tuning procedure, and the closed-loop performance varies with environmental or loading conditions since the dynamics of the vessel are eminently nonlinear. Gain scheduling is normally used to address the nonlinearity of the system. To overcome these problems, a sliding mode control was evaluated. This controller is robust to variations in environmental and loading conditions, it maintains performance and stability for a large range of conditions, and presents an easy tuning methodology. The performance of the controller was evaluated numerically and experimentally in order to address its effectiveness. The results are compared with those obtained from conventional PID controller. (c) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Precision agriculture (PA) technologies are being applied to crops in Brazil, which are important to ensure Brazil`s position in agricultural production. However, there are no studies available at present to indicate the extent to which PA technologies are being used in the country. Therefore, the main objective of this research was to investigate how the sugar-ethanol industry in So Paulo state, which produces 60% of the domestic sugarcane, is adopting and using these techniques. For this purpose, primary data were used, which were obtained from a questionnaire sent to all companies operating in the sugar-ethanol industry in the region. The aim was to determine to what extent these companies are adopting and using PA technologies, and also to promote a more in-depth discussion of the topic within the sugar-ethanol industry. Information was obtained on the features of the companies, on sources of information that they use for adopting these technologies, on their impacts on these companies and on obstacles hindering their adoption. The main conclusions of this research suggest that companies that adopt and use PA practices reap benefits, such as managerial improvements, higher yields, lower costs, minimization of environmental impacts and improvements in sugarcane quality.
Resumo:
To obtain a high quality EMG acquisition, the signal must be recorded as far away as possible from muscle innervations and tendon zones, which are known to shift during dynamic contractions. This study describes a methodology, using commercial bipolar electrodes, to identify better electrode positions for superficial EMG of lower limb muscles during dynamic contractions. Eight female volunteers participated in this study. Myoelectric signals of the vastus lateralis, gastrocnemius medialis, peroneus longus and tibialis anterior muscles were acquired during maximum isometric contractions using bipolar electrodes. The electrode positions of each muscle were selected assessing SENIAM and then, other positions were located along the length of muscle up and down the SENIAM site. The raw signal (density), the linear envelopes, the RMS value, the motor point site, the position of the IZ and its shift during dynamic contractions were taken into account to select and compare electrode positions. For vastus lateralis and peroneus longus, the best sites were 66% and 25% of muscle length, respectively (similar to SENIAM location). The position of the tibialis anterior electrodes presented the best signal at 47.5% of its length (different from SENIAM location). The position of the gastrocnemius medialis electrodes was at 38% of its length and SENIAM does not specify a precise location for signal acquisition. The proposed method should be considered as another methodological step in every EMG study to guarantee the quality of the signal and subsequent human movement interpretations. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Introduction: Mini-implants are placed in restricted sites, requiring an accurate surgical technique. However, no systematic study has quantified technique accuracy to reliably predict the surgical risks. Therefore, a graduated 3-dimensional radiographic-surgical guide (G-RSG) was proposed, and its inaccuracy and risk index (RI) were estimated. Methods: The sample consisted of 6 subjects (4 male, 2 female), who used mini-implant anchorage. Ten drill-free screws (DFS) were placed by using the G-RSG. The central point of the mesiodistal septum width (SW) was the selected implant site on the presurgical radiograph. The distances between DFS and the adjacent teeth (5-DFS and 6-DFS) were measured to evaluate screw centralization and inaccuracy degree (ID). These distances were statistically compared by independent t tests, and inaccuracy was determined by the expression ID = (5-DFS-6-DFS)/2, which represents deviation of the mini-implant`s final position regarding the central point initially selected. Then SW, ID, and screw diameter (SO) were combined to estimate the surgical risk with RI expressed by RI = SO/SW-ID. Results: The 5-DFS and 6-DFS distances were not significantly different. The ID of the G-RSG was 0.17 mm. The low ID ensured a safe RI (<1) in spite of the restricted SW. Conclusions: The G-RSG accuracy allowed fine prediction of the final DFS position in the inter-radicular septum, with a low RI, which is a helpful tool to estimate surgical risks. (Am J Orthod Dentofacial Orthop 2009; 136: 722-35)
Resumo:
Aim To evaluate the influence of implant positioning into extraction sockets on osseointegration. Material and methods Implants were installed immediately into extraction sockets in the mandibles of six Labrador dogs. In the control sites, the implants were positioned in the center of the alveolus, while in the test sites, the implants were positioned 0.8 mm deeper and more lingually. After 4 months of healing, the resorptive patterns of the alveolar crest were evaluated histomorphometrically. Results All implants were integrated in mineralized bone, mainly composed of mature lamellar bone. The alveolar crest underwent resorption at the control as well as at the test sites. After 4 months of healing, at the buccal aspects of the control and test sites, the location of the implant rough/smooth limit to the alveolar crest was 2 +/- 0.9 mm and 0.6 +/- 0.9 mm, respectively (P < 0.05). At the lingual aspect, the bony crest was located 0.4 mm apically and 0.2 mm coronally to the implant rough/smooth limit at the control and test sites, respectively (NS). Conclusions From a clinical point of view, implants installed into extraction sockets should be positioned approximately 1 mm deeper than the level of the buccal alveolar crest and in a lingual position in relation to the center of the alveolus in order to reduce or eliminate the exposure above the alveolar crest of the endosseous (rough) portion of the implant. To cite this article:Caneva M, Salata LA, de Souza SS, Baffone G, Lang NP, Botticelli D. Influence of implant positioning in extraction sockets on osseointegration: histomorphometric analyses in dogs.Clin. Oral Impl. Res. 21, 2010; 43-49.
Resumo:
This paper describes a new mechanical samples positioning system that allows the safe placement and removal of biological samples for prolonged irradiation, in a nuclear reactor during full-power continuous operation. Also presented herein the materials of construction and operating principles. Additionally, this sample positioning system is compared with an existing pneumatic and automated transfer system, already available at the research reactors. The system consists of a mechanical arm with a claw, which can deliver the samples for irradiations without reactor shutdown. It was installed in the lEA-R1 research reactor at Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, Brazil, and for the past 5 years, the system has successfully operated and allowed the conducting of important experiments. As a result of its introduction, the facility has been in a position to positively respond to the increased demand in studies of biology, medicine, physics, engineering, detector/dosimeter calibrations, etc. It is one example of the appropriated technologies that save energy and resources. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
We perform an analysis of the electroweak precision observables in the Lee-Wick Standard Model. The most stringent restrictions come from the S and T parameters that receive important tree level and one loop contributions. In general the model predicts a large positive S and a negative T. To reproduce the electroweak data, if all the Lee-Wick masses are of the same order, the Lee-Wick scale is of order 5 TeV. We show that it is possible to find some regions in the parameter space with a fermionic state as light as 2.4-3.5 TeV, at the price of rising all the other masses to be larger than 5-8 TeV. To obtain a light Higgs with such heavy resonances a fine-tuning of order a few per cent, at least, is needed. We also propose a simple extension of the model including a fourth generation of Standard Model fermions with their Lee-Wick partners. We show that in this case it is possible to pass the electroweak constraints with Lee-Wick fermionic masses of order 0.4-1.5 TeV and Lee-Wick gauge masses of order 3 TeV.
Resumo:
OBJETIVO: avaliar a participação da protrusão mandibular ortopédica e da posição condilar na prevalência de sinais e sintomas de disfunção temporomandibular (DTM). METODOLOGIA: a amostra foi composta por 60 indivíduos divididos em 3 grupos, sendo o grupo I correspondente a indivíduos não tratados; o grupo II composto por jovens em tratamento com o Bionator; e o grupo III por jovens já tratados com este aparelho. Os indivíduos da amostra responderam a um questionário relativo aos principais sintomas de DTM, permitindo a classificação dos mesmos de acordo com a presença e severidade dessas disfunções. Esses jovens também se submeteram à avaliação da movimentação mandibular, palpação dos músculos mastigatórios e inspeção de ruídos articulares. Radiografias transcranianas padronizadas das ATMs direita e esquerda foram realizadas, para obtenção do grau de concentricidade condilar. RESULTADOS: os testes ANOVA, Kruskal-Wallis e qui-quadrado foram utilizados para análise dos dados. De acordo com os resultados do questionário anamnésico, 66,67% da amostra foram classificados com ausência de DTM; 30% com DTM leve e apenas 3,33% com DTM moderada, sem diferença entre os grupos estudados (p > 0,05). Quanto à concentricidade condilar, o grupo II apresentou os valores de menor concentricidade (côndilos mais anteriorizados), com diferença estatisticamente significante em relação ao grupo I (p < 0,05). Uma associação entre a concentricidade condilar e a prevalência de DTM, no entanto, não foi encontrada. CONCLUSÃO: a protrusão ortopédica, apesar de alterar a posição dos côndilos, não aumentou a prevalência de DTM na população estudada.
Resumo:
INTRODUÇÃO: quanto menor a dimensão do voxel, maior a nitidez da imagem de tomografia computadorizada Cone-Beam (TCCB), porém, maior a dose de radiação emitida. OBJETIVOS: avaliar e comparar a reprodutibilidade da mensuração da espessura das tábuas ósseas vestibular e lingual em imagens de TCCB, utilizando diferentes protocolos de aquisição de imagem com variação da dimensão do voxel. MÉTODOS: exames de TCCB foram tomados de 12 mandíbulas humanas secas, com dimensão do voxel de 0,2; 0,3 e 0,4mm, no aparelho i-CAT Cone-Beam 3-D Dental Imaging System. No software i-CAT Viewer, foi mensurada a espessura das tábuas ósseas vestibular e lingual, em um corte axial passando 12mm acima do forame mentoniano do lado direito. A reprodutibilidade intraexaminador foi avaliada por meio da aplicação do teste t pareado. Para a comparação interexaminadores, foi utilizado o teste t independente. Os resultados foram considerados com o nível de significância de 5%. RESULTADOS: observou-se uma excelente reprodutibilidade interexaminadores para os três protocolos avaliados. A reprodutibilidade intraexaminadores foi muito boa, com exceção de algumas regiões dos dentes anteriores, que mostraram diferenças estatisticamente significativas, independentemente da dimensão do voxel. CONCLUSÃO: a mensuração da espessura das tábuas ósseas vestibular e lingual em imagens de TCCB mostrou boa precisão para exames obtidos com voxel de 0,2; 0,3 ou 0,4mm. A reprodutibilidade das mensurações na região anterior da mandíbula foi mais crítica do que na região posterior.