76 resultados para Patient-satisfaction

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate the advantages and disadvantages of the new low-addition (add) (+3.00 diopter [D]) ReSTOR multifocal IOL compared with the preceding ReSTOR model with +4.00 D add. SETTING: University Eye Hospital, Tuebingen, Germany. DESIGN: Comparative case series. METHODS: Patients with a +3.00 D or +4.00 D add multifocal IOL were examined for uncorrected and distance-corrected visual acuity at distance, intermediate, and near. A defocus profile was assessed, individual reading distance and the distance for lowest intermediate visual acuity were determined. Patient satisfaction was evaluated with a standardized questionnaire. Contrast sensitivity was tested under mesopic and photopic conditions. RESULTS: Uncorrected and distance-corrected intermediate visual acuities were statistically significantly better in the +3.00 D add group (24 eyes) than in the +4.00 D add group (30 eyes); distance and near visual acuities were not different between groups. The defocus profile significantly varied between groups. The +4.00 D add group had a closer reading distance (33.0 cm) than the +3.00 D add group (43.5 cm), a closer point of lowest intermediate visual acuity (65.8 cm versus 86.9 cm) and worse lowest intermediate visual acuity (20/59 +/- 4.5 letters [SD] versus 20/48 +/- 5.5 letters). Thus, patients in the +3.00 D add group reported being more satisfied with intermediate visual acuity. The +3.00 D add group reported more glare but less halos than the +4.00 D add group; contrast sensitivity was not different. CONCLUSION: The lower addition resulted in a narrower defocus profile, a farther reading distance, and better intermediate visual acuity and thus increased patient satisfaction.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: To evaluate soft tissue characteristics in individuals with cleft lip and palate and the degree of satisfaction of these individuals after rehabilitation. Setting: Hospital for Rehabilitation of Craniofacial Anomalies, Brazil. Patients: Forty-five individuals with repaired complete unilateral cleft lip and palate, aged 15 to 30 years. Interventions: One hundred thirty-five frontal facial photographs were obtained at rest and in natural and forced smile. Specialists in periodontics evaluated the soft tissue characteristics. Both patients and specialists evaluated the smiles and scored them as esthetically unpleasant, acceptable, or pleasant. Main Outcome Measures: Comparison of the cleft area with the contralateral region was performed for evaluation of soft tissue. The results of the degree of satisfaction with smile were expressed as percentages and means. The findings between patients and periodontists experienced or inexperienced with cleft care were compared. Results: Statistically significant differences were observed for alveolar process deficiency and absence of papilla in the esthetic area between groups (p < .05). Results show 84.4% of individuals considered their smile as esthetically pleasant. Specialists in periodontics of both groups scored the natural smile and forced smile as esthetically acceptable. There was a statistically significant difference in the mean of patients compared with both groups of specialists in periodontics (p < .05). Conclusions: Evaluation and knowledge of the soft tissue characteristics is extremely important for successful rehabilitation. The esthetic values and degree of patient satisfaction are essential for treatment success, since smile reconstruction should be esthetically pleasant to the patient.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The present work aims at the application of the decision theory to radiological image quality control ( QC) in diagnostic routine. The main problem addressed in the framework of decision theory is to accept or reject a film lot of a radiology service. The probability of each decision of a determined set of variables was obtained from the selected films. Methods: Based on a radiology service routine a decision probability function was determined for each considered group of combination characteristics. These characteristics were related to the film quality control. These parameters were also framed in a set of 8 possibilities, resulting in 256 possible decision rules. In order to determine a general utility application function to access the decision risk, we have used a simple unique parameter called r. The payoffs chosen were: diagnostic's result (correct/incorrect), cost (high/low), and patient satisfaction (yes/no) resulting in eight possible combinations. Results: Depending on the value of r, more or less risk will occur related to the decision-making. The utility function was evaluated in order to determine the probability of a decision. The decision was made with patients or administrators' opinions from a radiology service center. Conclusion: The model is a formal quantitative approach to make a decision related to the medical imaging quality, providing an instrument to discriminate what is really necessary to accept or reject a film or a film lot. The method presented herein can help to access the risk level of an incorrect radiological diagnosis decision.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background There are multitudes of procedures in plastic surgery used to correct hypertrophic and pendulous breasts in patients with heavy and ptotic breasts who need great resections of breast tissue, where the suprasternal notch-to-nipple distance is long and the use of nipple-areola transposition techniques is a challenge for the plastic surgeon. The purpose of this study is to present a technique of reduction mammaplasty that could solve these problems based on the following principles: mammary reduction utilizing a thin superior medial pedicle (0.8-1.5 cm thick) and the resection performed in two steps: (1) the base excess at a plane perpendicular to the breast (this determines the cone`s height) and (2) central half keel (this determines the breast diameter reduction). Methods Ninety patients with mammary hypertrophy were operated on at the ""Hospital das Clinicas,"" Sao Paulo University Medical School, between January 2000 and November 2005. Inclusion in this study required a minimum of 12-cm change in nipple position and a 750-g breast resection. Results The mean change in nipple position was 16 cm (range = 12-21 cm). The mean weight of each breast was 1400 (range = 750-3000 g).Considering the great amount of volume removed and the size of the operated breasts, few complications were observed and were similar to those reported following other techniques described in the literature. Patient satisfaction following this procedure was high. Conclusion The results of this study clearly demonstrate that thin superior medial pedicle reduction mammaplasty is a safe and reliable technique in cases of severe mammary hypertrophy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim Chagas` disease is an endemic parasitosis found in Latin America. The disease affects different organs, such as heart, oesophagus, colon and rectum. Megacolon is the most frequent long-term complication, caused by damage to the myoenteric and submucous plexus, ultimately leading to a functional barrier to the faeces. Patients with severe constipation are managed surgically. The study aimed to analyse the 10-year minimum functional outcome after rectosigmoidectomy with posterior end-to-side anastomosis (RPESA). Method A total of 21 of 46 patients were available for follow up. Patients underwent clinical, radiological and manometric evaluation, and the results were compared with preoperative parameters. Results Of the 21 patients evaluated, 81% (17) were female, with a mean age of 60.6 years. Good function was achieved in all patients, with significant improvement in defaecatory frequency (P < 0.0001), usage of enemas (P < 0.0001) and patient satisfaction. Barium enema also showed resolution of the colonic and rectal dilatation in 19 cases evaluated postoperatively. Conclusion Minimal 10-year follow up of RPESA showed excellent functional results, with no recurrence of constipation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: There is scarce literature on assessing surgical results and the impact of upper blepharoplasty on quality of life of patients. OBJECTIVE: To evaluate the impact on quality of life of patients submitted to upper blepharoplasty. METHODS: A prospective study using a standardized questionnaire applied to adult women submitted to upper blepharoplasty and evaluated 90 days later to estimate the surgical impact on quality of life and complications. RESULTS: Forty-one healthy adult females (median age of 53 years) were evaluated from June 2005 to March 2006. The questionnaire showed high internal consistency. The quality of life element with greater impact on the first postoperative week was related to physical appearance perception and that of lesser impact was associated to relationship with relatives and close friends. Hypertrophic scar was the main late complication. Satisfaction levels with the surgery were significantly related with absence of undesirable effects (p<0.01). CONCLUSIONS: The authors suggest a consistent tool to evaluate the impact of this surgical procedure on quality of life of patients. High satisfaction levels with upper blepharoplasty stood out. Keywords: Blepharoplasty; Quality of life; Patient satisfaction

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Plastic surgery is based on improving esthetic for the patient. In most services, the surgery outcome is evaluated in a subjective manner. Aim: to objectively assess the degree of patient satisfaction one year after rhinoplasty using the Rhinoplasty Outcome Evaluation questionnaire at a referral academic center. Materials and Methods: 69 patients operated in the otorhinolaryngology service were selected. The patients were operated upon by third year residents during the period from January to December 2007 and answered the questionnaire translated by the authors of this study. Results: we obtained a mean value of 73.25% of satisfaction for primary rhinoplasty and a mean value of 72.02% of satisfaction for secondary rhinoplasty. Conclusion: the level of satisfaction presented by the patients was considered to be very good.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Allergies in Latin America is the first cross-national survey that describes the symptoms, impact, and treatment of nasal allergies (NAs) in individuals >= 4 years old in Latin America (LA). In total, 22,012 households across the Latin American countries of Argentina, Brazil, Chile, Colombia, Ecuador, Mexico, Peru, and Venezuela were screened for children, adolescents, and adults with a diagnosis of NA and either symptoms or treatment in the past 12 months. A total of 1088 adults and 457 children and adolescents were included and the sample was probability based to ensure valid statistical inference to the population. Approximately 7% of the LA population was diagnosed with NAs with two of three respondents stating that their allergies were seasonal or intermittent in nature. A general practice physician or otolaryngologist diagnosed the majority of individuals surveyed. Nasal congestion was the most common and bothersome symptom of NAs. Sufferers indicated that their symptoms affected productivity and sleep and had a negative impact on quality of life. Two-thirds of patients reported taking some type of medication for their NAs, with a roughly equal percentage of patients reporting taking over-the-counter versus prescription medications. Changing medications was most commonly done in those reporting inadequate efficacy. The most common reasons cited for dissatisfaction with current medications were related to inadequate effectiveness, effectiveness wearing off with chronic use, failure to provide 24-hour relief, and bothersome side effects (e.g., unpleasant taste and retrograde drainage into the esophagus). Findings from this cross-national survey on NAs have confirmed a high prevalence of physician-diagnosed NAs and a considerable negative impact on daily quality of life and work productivity as well as substantial disease management challenges in LA. Through identification of disease impact on the LA population and further defining treatment gaps, clinicians in LA may better understand and treat NAs, thus leading to improvements in overall patient satisfaction and quality of life. (Allergy Asthma Proc 31:S9-S27, 2010; doi: 10.2500/aap.2010.31.3347)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

P>This study assessed the effect of simulated mastication on the retention of two stud attachment systems for 2-implants overdentures. Sixteen specimens, each simulating an edentulous ridge with implants and an overdenture were divided into two groups, according to the attachment system: Group I (Nobel Biocare ball-socket attachments) and Group II (Locator attachments). Retention forces were measured before and after 400 000 simulated masticatory loads in a customised device. Data were compared by two-way anova followed by Bonferroni test (alpha = 0 center dot 05). Group I presented significantly lower retention forces (Newtons) than Group II at baseline (10 center dot 6 +/- 3 center dot 6 and 66 center dot 4 +/- 16 center dot 0, respectively). However, differences were not significant after 400 000 loads (7 center dot 9 +/- 4 center dot 3 and 21 center dot 6 +/- 17 center dot 0). The number of cycles did not influence the measurements in Group I, whereas a non-linear descending curve was found for Group II. It was concluded that simulated mastication resulted in minor changes for the ball attachment tested. Nevertheless, it reduced the retention of Locator attachments to 40% of the baseline values, what suggests that mastication is a major factor associated with maintenance needs for this system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

P>The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator (R)) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective The purpose of this study was to evaluate the retention force of an O-ring attachment system in different inclinations to the ideal path of insertion, using devices to compensate angulations. Material and methods Two implants were inserted into an aluminum base, and ball attachments were screwed to implants. Cylinders with O-rings were placed on ball attachments and connected to the test device using positioners to compensate implant angulations (0 degrees, 7 degrees, and 14 degrees). Plexiglass bases were used to simulate implant angulations. The base and the test device were positioned in a testing apparatus, which simulated insertion/removal of an overdenture. A total of 2900 cycles, simulating 2 years of overdenture use, were performed and 36 O-rings were tested. The force required for each cycle was recorded with computer software. Longitudinal sections of ball attachment-positioner-cylinder with O-rings of each angulation were obtained to analyze the relationship among them, and O-ring sections tested in each angulation were compared with an unused counterpart. A mixed linear model was used to analyze the data, and the comparison was performed by orthogonal contrasts (alpha=0.05). Results At 0 degrees, the retention force decreased significantly over time, and the retention force was significantly different in all comparisons, except from 12 to 18 months. When the implants were positioned at 7 degrees, the retention force was statistically different at 0 and 24 months. At 14 degrees, significant differences were found from 6 and 12 to 24 months. Conclusions Within the limitations of this study, it was concluded that O-rings for implant/attachments perpendicular to the occlusal plane were adequately retentive over the first year and that the retentive capacity of O-ring was affected by implant inclinations despite the proposed positioners. To cite this article:Rodrigues RCS, Faria ACL, Macedo AP, Sartori IAM, de Mattos MGC, Ribeiro RF. An in vitro study of non-axial forces upon the retention of an O-ring attachment.Clin. Oral Impl. Res. 20, 2009; 1314-1319.doi: 10.1111/j.1600-0501.2009.01742.x.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

P>The use of seven domains for the Oral Health Impact Profile (OHIP)-EDENT was not supported for its Brazilian version, making data interpretation in clinical settings difficult. Thus, the aim of this study was to assess patients` responses for the translated OHIP-EDENT in a group of edentulous subjects and to develop factor scales for application in future studies. Data from 103 conventional and implant-retained complete denture wearers (36 men, mean age of 69 center dot 1 +/- 10 center dot 3 years) were assessed using the Brazilian version of the OHIP-EDENT. Oral health-related quality of life domains were identified by factor analysis using principal component analysis as the extraction method, followed by varimax rotation. Factor analysis identified four factors that accounted for 63% of the 19 items total variance, named masticatory discomfort and disability (four items), psychological discomfort and disability (five items), social disability (five items) and oral pain and discomfort (five items). Four factors/domains of the Brazilian OHIP-EDENT version represent patient-important aspects of oral health-related quality of life.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Although the use of local flaps in conservative breast surgery (CBS) reconstruction is a reliable technique, little information has been available regarding outcome following the use of perforator flaps. The purpose of this study is to analyze the feasibility, surgical planning and outcome following CBS reconstruction with intercostal artery perforator (ICAP) flap. Patients/methods: Thirteen patients underwent CBS reconstructions with an ICAP flap. These flaps were raised from adjacent tissue located on the lateral and thoracic region and based on perforators originating from the costal and muscular segment of the intercostal vessels. The technique was indicated in patients with small/moderate volume breasts. Results: Mean time of follow-up was 32 months. Flap complications were evaluated and information on patient satisfaction were collected. 61.5 percent had tumors located in the lower-outer quadrants and 69.2 percent had tumors measuring 2 cm or less (T1). Complications occurred in 3 patients (23%), including wound dehiscence in 2 patients and fat necrosis in one. All cases were treated by conservative approach with a good result. No flap loss or wound infection were reported. 90 percent were either satisfied or very satisfied with their result. Conclusion: The ICAP flap is a reliable technique for immediate CBS reconstruction. The technique is advantageous because it does not require the use of muscle transfer, with minimum donor site morbidity. Success depends on patient selection, coordinated planning with the oncological surgeon and careful intra-operative management. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Although the biodimensional anatomical expander-implant system (BEIS) is a reliable technique, little information has been available regarding outcome following nipple-areola sparing mastectomy (NSM). To perform the resection of glandular tissue, while improving the surgical access and maintaining the nipple-areola vascularization we have developed a new approach for NSM based on the double concentric periareolar incision (DCPI). The purpose of this study is to analyze the feasibility, surgical planning and its outcome following NSM. 18 patients underwent NSM reconstructions. Mean time of follow-up was 29 months. The technique was indicated in patients with small/moderate volume breasts. Flap complications were evaluated and information on aesthetic results and patient satisfaction were collected. 83.3% had tumors measuring 2 cm or less (T1) and 72.1% were stage 0 and 1. All patients presented peripherally tumors located (at least 5 cm from the nipple). Skin complications occurred in 11.1%. One patient (5.5%) presented small skin necrosis and a wound dehiscence was observed in one patient (5.5%). The aesthetic result was good/very good in 94.4 percent and the majority of patients were very satisfied/satisfied. No local recurrences were observed. All complications except one were treated by a conservative approach. DCPI-BEIS is a simple and reliable technique for NSM reconstruction. The success depends on patient selection, coordinated planning with the oncologic surgeon and careful intra-operative and post-operative management. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction. Sexual satisfaction is linked to life satisfaction, and erectile dysfunction (ED) may lead to an impaired quality of life (QOL). Aim. Our goal was to evaluate the QOL among Brazilian patients with ED, before and after three kinds of treatment. Methods. Men aged 25-55 years, with a diagnosis of psychogenic or mixed ED, according to the Classification of Mental and Behavioral Disorders of the International Classification of Diseases, 10th edition, and the Standard Practice in Sexual Medicine, were randomly assigned to three treatment groups: counseling, sildenafil, and sildenafil plus counseling. At baseline each group had 40 patients. Sildenafil was provided in 50 mg that could be adjusted to 100 mg. The patients could initially take one to two tablets per week and the entire treatment lasted for 3 months. Counseling was provided in group sessions that took place once a week. They were evaluated at baseline and after 3 months of treatment with the Male Sexual Quotient (MSQ) and the Sexual Health Inventory for Men (SHIM). Main Outcome Measures. The correlation between the patients` MSQ score and scores on the SHIM. Results. One hundred seventeen patients were enrolled. The three groups were similar according to age, marital status, mean time of ED, and ED severity and etiology. At baseline, MSQ and SHIM total scores were not different among the three groups. MSQ scores increased from 41.2 +/- 15.3, 38.7 +/- 18.0, and 46.8 +/- 17.0 to 48.5 +/- 15.3, 63.8 +/- 21.6, and 70.0 +/- 17.3 after counseling, sildenafil, and sildenafil plus counseling, respectively (P < 0.05). SHIM scores also increased significantly (9.6 +/- 4.1, 9.7 +/- 4.1, and 10.2 +/- 3.9 to 12.1 +/- 3.9, 16.7 +/- 5.6, and 17.7 +/- 4.5 after counseling, sildenafil, and sildenafil plus counseling, respectively) (P < 0.05). There were no serious adverse events related to sildenafil, and no patient was withdrawn from the study because of an adverse event. Conclusions. The three treatments were significantly efficient, and the best treatment was sildenafil associated with counseling.