312 resultados para PORCINE MODEL
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Purpose: To analyze in an experimental animal model the effect of 4 different levels of stents-graft oversizing on non-atherosclerotic aortas such as those found in young individuals who undergo stent-graft repair for traumatic aortic injuries. Methods: The diameter of the porcine thoracic aorta is similar to the aorta of young adults (18-20 mm), so 25 pigs were randomized into 5 groups: 1 control (without stent-graft) and 4 oversizing groups (A: 10%-19%, B: 20%-29%, C: 30%-39%, and D: >40%). Two types of biomechanical tests were performed on all aortas 4 weeks after endoprosthesis deployment. Results: The results of the detachment test, which analyzed the strength necessary to remove the stent-graft from the aorta, were similar in the 4 groups (A: 42 N, B: 41 N, C: 46 N, and D: 46 N). However, 2 aortas ruptured during the tests (groups C and D). The second test was performed in 3 aortic segments. Maximum shear strength, maximum stress, and maximum tension supported by the aortic wall had a negative and linear correlation with oversizing. There were significant differences in all 4 groups when compared with the control group. Strain, which reflects the elastic properties of the aortic wall, was very similar in all 4 groups, but a great difference was found when compared with the control group (p<0.0001). Conclusion: The study showed an important subacute change in the biomechanical properties of the aortic wall after implantation of an oversized endoprosthesis. This weakness of the aortic wall was confirmed by 2 ruptures during the detachment test. These results partially explain the interaction of stent-grafts with non-atherosclerotic thoracic aortas and may serve as a basis for further studies and the development of specific material to be used in vascular trauma and young patients. J Endovasc Ther. 2011; 18: 576-584
Resumo:
Background: The swine is an essential model for carrying out preclinical research and for teaching complex surgical procedures. There is a lack of experimental models describing anatomical and surgical aspects of total pancreatectomy in the pig. Materials and Methods: The experiments were performed on 10 white male swine weighing 27-33 kg. The animals were premedicated with midazolam (0.4 mg/kg, i.m.) and ketamine (4 mg/kg, i.m.). Anesthesia was induced with propofol (1-2 mg/kg, i.v.) and was maintained with propofol and fentanyl (0.3 mg and 0.1 mu g/kg/min, respectively, i.v.). The surgical period ranged from 44 to 77 min. The pancreas anatomy, and the main arterial, venous and pancreatic duct anatomy were assessed. Results: The pancreas anatomy was composed of 3 lobes, the `splenic`, `duodenal` and `connecting` lobe which is attached to the anterior portion of the portal vein. The splenic artery and the junction of the splenic vein and portal vein were divided. The left gastric artery was dissected and separated from its origin at the splenic artery. The head of the pancreas is disposed in a C shape. The pancreas was dissected and liberated from the right portion of the portal vein and the infrahepatic vena cava. The pancreas was separated from the duodenum preserving the pancreaticoduodenal artery, then we performed the total pancreatectomy preserving the duodenum, common bile duct and spleen. Conclusion: Total pancreatectomy with duodenum, bile duct and spleen preservation in the pig is feasible and an important instrument for research purposes and teaching surgical technique. Copyright (C) 2010 S. Karger AG, Basel
Resumo:
Positive end-expiratory pressure (PEEP) and sustained inspiratory insufflations (SI) during acute lung injury (ALI) are suggested to improve oxygenation and respiratory mechanics. We aimed to investigate the hemodynamic effects of PEEP with and without alveolar recruiting maneuver in a mild ALI model induced by inhalation of hydrochloric acid. Thirty-two pigs were randomly allocated into four groups (Control-PEEP, Control-SI, ALI-PEEP and ALI-SI). ALI was induced by intratracheal instillation of hydrochloric acid. PEEP values were progressively increased and decreased from 5, 10, 15 and 20 cmH(2)O in all groups. Three SIs maneuvers of 30 cmH(2)O for 20 s were applied to the assignable groups between each PEEP level. Transesophageal echocardiography (TEE), global hemodynamics, oxygenation indexes and gastric tonometry were measured 5 min after the maneuvers had been concluded and at each established value of PEEP (5, 10, 15 and 20 cmH(2)O). The cardiac index, ejection fraction and end-diastolic volume of right ventricle were significantly (P < 0.001) decreased with PEEP in both Control and ALI groups. Left ventricle echocardiography showed a significant decrease in end-diastolic volume at 20 cmH(2)O of PEEP (P < 0.001). SIs did not exert any significant hemodynamic effects either early (after 5 min) or late (after 3 h). In a mild ALI model induced by inhalation of hydrochloric acid, significant hemodynamic impairment characterized by cardiac function deterioration occurred during PEEP increment, but SI, probably due to low applied values (30 cmH(2)O), did not exert further negative hemodynamic effects. PEEP should be used cautiously in ALI caused by acid gastric content inhalation.
Resumo:
Background: This study was designed to evaluate serum potassium level variation in a porcine model of hemorrhagic shock ( HS). Methods: Eight pigs were studied in a controlled hemorrhage model of HS. Blood withdrawal began at a 50 mL/min to 70 mL/min rate, adjusted to reach a mean arterial pressure ( MAP) level of 60 mm Hg in 10 minutes. When MAP reached 60 mm Hg, the blood withdrawal rate was adjusted to maintain a MAP decrease rate of 10 mm Hg every 2 minutes to 4 minutes. Arterial and mixed venous blood samples were collected at MAP levels of 60 mm Hg, 50 mm Hg, 40 mm Hg, 30 mm Hg, 20 mm Hg, and 10 mm Hg and analyzed for oxygen saturation, PO(2), PCO(2), potassium, lactate, bicarbonate, hemoglobin, pH, and standard base excess. Results: Significant increase in serum potassium occurred early in all animals. The rate of rise in serum potassium and its levels accompanied the hemodynamic deterioration. Hyperkalemia ( K >5 mmol/L) incidence was 12.5% at 60 mm Hg and 50 mm Hg, 62.5% at 40 mm Hg, 87.5% at 30 mm Hg, and 100% at 20 mm Hg. Strong correlations were found between potassium levels and lactate ( R = 0.82), SvO(2) ( R = 0.87), Delta pH ( R = 0.83), and Delta PCO(2) ( R = 0.82). Conclusions: Serum potassium increase accompanies the onset of HS. The rise in serum potassium was directly related to the hemodynamic deterioration of HS and strongly correlated with markers of tissue hypoxia.
Resumo:
Background-Epicardial coronary injury is by far the most feared complication of epicardial ablation. Little information is available regarding the chronic effects of delivering radiofrequency in the vicinity of large coronary vessels, and the long-term impact of this approach for mapping and ablation on epicardial vessel integrity is poorly understood. Therefore, the aim of this study was to characterize the acute and chronic histopathologic changes produced by in vivo epicardial pulses of radiofrequency ablation on coronary artery of porcine hearts. Methods and Results-Seven pigs underwent a left thoracotomy. The catheter was sutured adjacent to the left anterior descending artery and left circumflex artery, and 20 pulses of radiofrequency energy were applied. Radiofrequency lesions located no more than 1 mm of the vessel were used for this analysis. Three animals were euthanized 20 days (acute phase) after the procedure and 4 animals after 70 days (chronic phase). The following parameters were obtained in each vessel analyzed: (1) internal and external perimeter; (2) vessel wall thickness; (3) tunica media thickness, and (4) tunica intima thickness. The presence of adipose tissue around the coronary arteries, the distance between the artery and the epicardium, and the anatomic relationship of the artery with the coronary vein was also documented for each section. Sixteen of 20 (80%) sections analyzed, showed intimal thickening with a mean of 0.18 +/- 0.14 mm compared with 0.13 +/- 0.16 mm in the acute phase (P=0.331). The mean tunica media thickness was 0.25 +/- 0.10 mm in the chronic phase animals compared with 0.18 +/- 0.03 mm in the acute phase animals (P=0.021). A clear protective effect of pericardial fat and coronary veins was also present. A positive correlation between depth of radiofrequency lesion and the degree of vessel injury expressed as intimal and media thickening (P=0.001) was present. A negative correlation was identified (r = -0.83; P=0.002) between intimal thickening and distance between epicardium and coronary artery. Conclusions-In this porcine model of in vivo epicardial radiofrequency ablation in proximity to coronary arteries leads to acute and chronic histopathologic changes characterized by tunica intima and media thickening, with replacement of smooth muscle cells with extracellular matrix, but no significant stenosis was observed up to 70 days after the ablation. The absence of acute coronary occlusion or injury does not preclude subsequent significant arterial damage, which frequently occurs when epicardial radiofrequency applications are delivered in close vicinity to the vessels. (Circ Arrhythm Electrophysiol. 2011;4:526-531.)
Resumo:
Sepsis remains a major cause of morbidity and mortality mainly because of sepsis-induced multiple organ dysfunction. In contrast to preclinical studies, most clinical trials of promising new treatment strategies for sepsis have failed to demonstrate efficacy. Although many reasons could account for this discrepancy, the misinterpretation of preclinical data obtained from experimental studies and especially the use of animal models that do not adequately mimic human sepsis may have been contributing factors. In this review, the potentials and limitations of various animal models of sepsis are discussed to clarify to which extent these findings are relevant to human sepsis. Such models include intravascular infusion of endotoxin or live bacteria, bacterial peritonitis, cecal ligation and perforation, soft tissue infection, pneumonia or meningitis models using different animal species including rats, mice, rabbits, dogs, pigs, sheep, and nonhuman primates. Despite several limitations, animal models remain essential in the development of all new therapies for sepsis and septic shock because they provide fundamental information about the pharmacokinetics, toxicity, and mechanism of drug action that cannot be replaced by other methods. New therapeutic agents should be studied in infection models, even after the initiation of the septic process. Furthermore, debility conditions need to be reproduced to avoid the exclusive use of healthy animals, which often do not represent the human septic patient.
Resumo:
This study aims to evaluate the effectiveness of the duodenojejunal bypass liner (DJBL) in the improvement of insulin resistance and reduction of cardiovascular risk among morbidly obese patients with type 2 diabetes mellitus, using the triglyceride/high-density lipoprotein (HDL) cholesterol ratio, percentage of weight loss, and glycemic control. We used the TG/HDL ratio with a cutoff value of 3.5 to identify patients with insulin resistance. The value of the initial ratio was compared with the ratio obtained 6 months after implantation to evaluate whether an improvement in insulin resistance occurred. We also evaluated the improvement of glycated hemoglobin levels and the weight loss resulted from the use of the device and correlated that with the improvement of the TG/HDL ratio. All patients implanted with the device presented a statistically significant reduction of the HbA1c levels, with most patients (70.3%) obtaining diabetes control with HbA1c levels lower than 7% at the end of the study. All patients also presented a significant weight reduction, with an average loss of 12.6% of their initial weight. We observed an important improvement in insulin resistance and metabolic syndrome, with a significant reduction of the TG/HDL ratio from 5.75 to 4.36 (p < 0.001) and 42.6% of the patients presenting a TG/HDL ratio lower than 3.5 at the end of the study. The DJBL, when used for a period of 6 months, is effective in the control of diabetes, weight loss, improvement of insulin resistance, and decrease of cardiovascular risk among morbidly obese patients with type 2 diabetes mellitus.
Resumo:
Background: This study of a chronic porcine postinfarction model examined whether linear epicardial cryoablation was capable of creating large, homogenous lesions in regions of the myocardium including scarred ventricle. Endocardial and epicardial focal cryolesions were also compared to determine if there were significant differences in lesion characteristics. Methods: Eighty focal endocardial and 28 focal epicardial cryoapplications were delivered to eight normal caprine and four normal porcine ventricular myocardium, and 21 linear cryolesions were applied along the border of infarcted epicardial tissue in a chronic porcine infarct model in six swines. Results: Focal endocardial cryolesions in normal animals measured 9.7 +/- 0.4 mm (length) by 7.3 +/- 1.4 mm (width) by 4.8 +/- 0.2 mm (depth), while epicardial lesions measured 10.2 +/- 1.4 mm (length) by 7.7 +/- 2 mm (width) by 4.6 +/- 0.9 mm (depth); P > 0.05. Linear epicardial cryolesions in the chronic porcine infarct model measured 36.5 +/- 7.8 mm (length) by 8.2 +/- 1.3 mm (width) by 6.0 +/- 1.2 mm (depth). The mean depth of linear cryolesions applied to the border of the infarct scar was 7 +/- 0.7 mm, as measured by magnetic resonance imaging. Conclusions:Cryoablation can create deep lesions when delivered to the ventricular epicardium. Endocardial and epicardial cryolesions created by a focal cryoablation catheter are similar in size and depth. The ability to rapidly create deep linear cryolesions may prove to be beneficial in substrate-based catheter ablation of ventricular arrhythmias.
Resumo:
Background/Aims: It is a challenge to adapt traditional in vitro diffusion experiments to ocular tissue. Thus, the aim of this work was to present experimental evidence on the integrity of the porcine cornea, barrier function and maintenance of electrical properties for 6 h of experiment when the tissue is mounted on an inexpensive and easy-to-use in vitro model for ocular iontophoresis. Methods: A modified Franz diffusion cell containing two ports for the insertion of the electrodes and a receiving compartment that does not need gassing with carbogen was used in the studies. Corneal electron transmission microscopy images were obtained, and diffusion experiments with fluorescent markers were performed to examine the integrity of the barrier function. The preservation of the negatively charged corneal epithelium was verified by the determination of the electro-osmotic flow of a hydrophilic and non-ionized molecule. Results: The diffusion cell was able to maintain the temperature, homogenization, porcine epithelial corneal structure integrity, barrier function and electrical characteristics throughout the 6 h of permeation experiment, without requiring CO(2) gassing when the receiving chamber was filled with 25 m M of HEPES buffer solution. Conclusion: The system described here is inexpensive, easy to handle and reliable as an in vitro model for iontophoretic ocular delivery studies. Copyright (C) 2010 S. Karger AG, Basel
Resumo:
Purpose: alpha-Melanocyte stimulating hormone protects kidneys against ischemia and sepsis induced acute kidney injury in rodents. We examined the efficacy of a-melanocyte stimulating hormone analogue AP214 to protect against acute kidney injury in higher vertebrates. Materials and Methods: We performed a prospective, blinded, randomized, placebo controlled study in 26 pigs. Laparoscopic technique was used for left nephrectomy and to induce complete warm ischemia in the right kidney for 120 minutes. AP214 (200 mu g/kg intravenously) was administered daily on the day of surgery and for 5 days thereafter. Kidney function was measured for 9 days. We measured changes in serum creatinine, estimated glomerular filtration rate, serum C-reactive protein and urine interleukin-18. Results: In the placebo control and AP214 groups mean peak serum creatinine was 10.2 vs 3.92 mg/dl and the estimated glomerular filtration rate nadir was 22.9 vs 62.6 ml per minute per kg (each p = 0.001). Functional nadir occurred at 72 vs 24 hours in the control vs AP214 groups. Estimated glomerular filtration rate outcome on postoperative day 9 was 118 vs 156 ml per minute per kg in the control vs AP214 groups (p = 0.04). Conclusions: We noted a robust renoprotective effect of AP214. A similar AP214 effect may be observed in humans. Future research includes mechanistic studies in pigs and a phase II human clinical trial of AP214 in kidney transplant and partial nephrectomy populations.
Resumo:
This study evaluated the arterial response to cobalt-chromium stents with and without polymer coating (Camouflage (R), Hemoteq AG, Wuerselen, Germany) implanted in pigs. Cobalt-chromium balloon-expandable stents (4 x 16 mm) were implanted in the common carotid arteries of nine pigs. Histological analysis of endothelialization, inflammation and injury was performed one month later. All stents were successfully deployed, and all but one animal survived the 30 study days. All arteries were patent. Endothelialization was nearly complete in most sections of all carotid stents in both groups. There were mild inflammatory infiltrate and mild-to-moderate injury, which were associated with the stent shafts and not significantly different between groups. Our findings suggest that, in porcine carotid arteries, the histological response to balloon-expandable cobalt-chromium stents coated with polymer (Camouflage (R), Hemoteq AG) is similar to the response to non-coated cobalt-chromium stents.
Resumo:
Recent works have pointed to the use of volatile electrolytes such as carbon dioxide (CO(2)) dissolved in aqueous solutions as a promising alternative to the precipitating agents conventionally used for protein recovery in the food and pharmaceutical industries. In this work we investigated experimental and theoretical aspects of the precipitation of porcine insulin, a biomolecule of pharmaceutical interest, using CO(2) as an acid- precipitating agent. The Solubility of porcine insulin in NaHCO(3) solutions in pressurized CO(2) was determined as a function of temperature and pressure, with a minimum being observed close to the protein isoclectric point. A thermodynamic model was developed and successfully utilized to correlate the experimental data. Insulin was considered a polyelectrolyte in the model and its self-association reactions were also taken into account. The biological activity of insulin was maintained after precipitation With CO(2), although some activity can be lost if foam is formed in the depressurization step. Biotechnol. Bioeng. 2009;103: 909-919. (C) 2009 Wiley Periodicals, Inc.
Resumo:
Background. The main purpose of the present investigation was to describe a model of intestinal denervation and in situ intestinal ischemia-reperfusion injury in adult rats, with utilization of the distal branch of the superior mesenteric artery close to the cecum for perfusion. Methods. In the root of the mesentery, the mesenteric artery and vein were completely isolated. Close to the cecal valve, a lymphatic node served as the reference point for the localization of the cecal artery, which was cannulated for perfusion with cold lactated Ringer`s solution. One hundred adult male rats were utilized in the study. Results. In a pilot study, we demonstrated that the cold ischemia time was sufficient to promote histopathologic intestinal changes characteristic of ischemia-reperfusion injury. Among 88 operated animals, 62 (70.5%) survived the procedure. Conclusion. The experimental model described herein has the advantage of preserving the entire intestine, which makes it more suitable for studies of physiological and morphological alterations after intestinal transplantation.
Resumo:
Meconium (MEC) is a potent inactivator of pulmonary surfactant. The authors studied the effects of polyethylene glycol addition to the exogenous surfactant over the lung mechanics and volumes. Human meconium was administrated to newborn rabbits. Animals were ventilated for 20 minutes and dynamic compliance, ventilatory pressure, and tidal volume were recorded. Animals were randomized into 3 study groups: MEC group (without surfactant therapy); S100 group (100 mg/kg surfactant); and PEG group (100 mg/kg porcine surfactant plus 5% PEG). After ventilation, a pulmonary pressure-volume curve was built. Histological analysis was carried out to calculate the mean alveolar size (Lm) and the distortion index (DI). Both groups treated with surfactant showed higher values of dynamic pulmonary compliance and lower ventilatory pressure, compared with the MEC group (P .05). S100 group had a larger maximum lung volume, V30, compared with the MEC group (P .05). Lm and DI values were smaller in the groups treated with surfactant than in the MEC group (P .05). No differences were observed between the S100 and PEG groups. Animals treated with surfactant showed significant improvement in pulmonary function as compared to nontreated animals. PEG added to exogenous surfactant did not improve lung mechanics or volumes.
Resumo:
Introduction: In vitro studies and ambulatory ECG recordings from the MERLIN TIMI-36 clinical trial suggest that the novel antianginal agent ranolazine may have the potential to suppress atrial arrhythmias. However, there are no reports of effects of ranolazine on atrial electrophysiologic properties in large intact animals. Methods and Results: In 12 closed-chest anesthetized pigs, effects of intravenous ranolazine (similar to 9 mu M plasma concentration) on multisite atrial effective refractory period (ERP), conduction time (CT), and duration and inducibility of atrial fibrillation (AF) initiated by intrapericardial acetylcholine were investigated. Ranolazine increased ERP by a median of 45 ms (interquartile range 29-50 ms; P < 0.05, n = 6) in right and left atria compared to control at pacing cycle length (PCL) of 400 ms. However, ERP increased by only 28 (24-34) ms in right ventricle (P < 0.01, n = 6). Ranolazine increased atrial CT from 89 (71-109) ms to 98 (86-121) ms (P = 0.04, n = 6) at PCL of 400 ms. Ranolazine decreased AF duration from 894 (811-1220) seconds to 621 (549-761) seconds (P = 0.03, n = 6). AF was reinducible in 1 of 6 animals after termination with ranolazine compared with all 6 animals during control period (P = 0.07). Dominant frequency (DF) of AF was reduced by ranolazine in left atrium from 11.7 (10.7-20.5) Hz to 7.6 (2.9-8.8) Hz (P = 0.02, n = 6). Conclusions: Ranolazine, at therapeutic doses, increased atrial ERP to greater extent than ventricular ERP and prolonged atrial CT in a frequency-dependent manner in the porcine heart. AF duration and DF were also reduced by ranolazine. Potential role of ranolazine in AF management merits further investigation. (J Cardiovasc Electrophysiol, Vol. 20, pp. 796-802, July 2009).