Resumo

Background/Aims: It is a challenge to adapt traditional in vitro diffusion experiments to ocular tissue. Thus, the aim of this work was to present experimental evidence on the integrity of the porcine cornea, barrier function and maintenance of electrical properties for 6 h of experiment when the tissue is mounted on an inexpensive and easy-to-use in vitro model for ocular iontophoresis. Methods: A modified Franz diffusion cell containing two ports for the insertion of the electrodes and a receiving compartment that does not need gassing with carbogen was used in the studies. Corneal electron transmission microscopy images were obtained, and diffusion experiments with fluorescent markers were performed to examine the integrity of the barrier function. The preservation of the negatively charged corneal epithelium was verified by the determination of the electro-osmotic flow of a hydrophilic and non-ionized molecule. Results: The diffusion cell was able to maintain the temperature, homogenization, porcine epithelial corneal structure integrity, barrier function and electrical characteristics throughout the 6 h of permeation experiment, without requiring CO(2) gassing when the receiving chamber was filled with 25 m M of HEPES buffer solution. Conclusion: The system described here is inexpensive, easy to handle and reliable as an in vitro model for iontophoretic ocular delivery studies. Copyright (C) 2010 S. Karger AG, Basel

Funda ao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP)

National Counsel of Technological and Scientific Development (CNPq), Brazil[565361/2008-2]

Identificador

OPHTHALMIC RESEARCH, v.43, n.4, p.208-216, 2010

0030-3747

http://producao.usp.br/handle/BDPI/20410

10.1159/000274494

http://dx.doi.org/10.1159/000274494

Idioma(s)

eng

Publicador

KARGER

Relação

Ophthalmic Research

Direitos

restrictedAccess

Copyright KARGER

Palavras-Chave #Ocular diffusion cell #Excised porcine cornea #Iontophoresis #Corneal integrity #Electron transmission microscopy #CELL-CULTURE MODELS #TRANSCORNEAL PERMEATION #TOPICAL FLUCONAZOLE #DRUG-DELIVERY #RABBIT CORNEA #AQUEOUS-HUMOR #PENETRATION #INVITRO #ACID #PERMEABILITY #Ophthalmology