117 resultados para OCULAR ABERRATIONS
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Purpose: To evaluate wavefront performance and modulation transfer function (MTF) in the human eye aft er the implantation of diffractive or refractive multifocal intraocular lenses (IOLs). Materials and Methods: This was a prospective, interventional, comparative, nonrandomized clinical study. Uncorrected distance and near visual acuity, and wavefront analysis including MTF curves (iTrace aberrometer, Tracey Technologies, Houston, TX, USA) were measured in 60 patients aft er bilateral IOL implantation with 6 months of follow-up. Forty eyes received the diffractive ReSTOR (Alcon), 40 eyes received the refractive ReZoom (Advanced Medical Optics) and 40 eyes, the Tecnis ZM900 (Advanced Medical Optics). The comparison of MTF and aberration between the intraocular lenses was performed using analysis of variance (ANOVA), followed by the Dunn test when necessary. Results: The mean uncorrected distance visual acuity was similar in all three groups of multifocal IOLs. The ReSTOR group provided better uncorrected near visual acuity than the ReZoom group (P < 0.001), but similar to the Tecnis group. Spherical aberration was significantly higher in the ReZoom group (P = 0.007). Similar MTF curves were found for the aspheric multifocal IOL Tecnis and the spheric multifocal IOL ReSTOR, and both performed better than the multifocal IOL ReZoom in a 5 mm pupil (P < 0.001 at all spatial frequencies). Conclusions: Diffractive IOLs studied presented similar MTF curves for a 5 mm pupil diameter. Both diffractive IOLs showed similar spherical aberration, which was significantly better with the full-diffractive IOL Tecnis than with the refractive IOL ReZoom.
Resumo:
PURPOSE: To determine whether implantation of an aspherical intraocular lens (IOL) results in reduced ocular aberrations and improved contrast sensitivity after cataract surgery without critical reduction of depth of focus. DESIGN: Double-blinded, randomized, prospective study. METHODS: In an intraindividual study of 25 patients with bilateral cataract, an aspherical IOL (Akreos Advanced Optic [AO]; Bausch & Lomb, Inc., Rochester, New York, USA) was implanted in one eye and a spherical IOL (Akreos Fit; Bausch & Lomb, Inc) in the fellow eye. Higher-order aberrations with a 5- and 6-mm pupil were measured with a dynamic retinoscopy aberrometer at 1 and 3 months after surgery. Uncorrected and best-corrected visual acuity and contrast sensitivity under mesopic and photopic conditions also were measured. Distance-corrected near and intermediate visual acuity were studied as a measurement of depth of focus. RESULTS: There was no statistically significant difference between eyes in uncorrected and best-corrected visual acuity at I and 3 months after surgery. There was a statistically significant between-group difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. The Akreos AO group obtained statistically significant lower values of higher-order aberrations and spherical aberration with 5- and 6-mm pupils compared with the Akreos Fit group (P < .05). There was no significant difference in distance-corrected near and intermediate visual acuity between both groups. CONCLUSIONS: Aspherical aberration-free Akreos AO IOL induced significantly less higher-order aberrations and spherical aberration than the Akreos Fit. Contrast sensitivity was better under mesopic conditions with the Akreos AO with similar results of depth of focus. (Am J Ophthalmol 2010;149:383-389. (C) 2010 by Elsevier Inc. All rights reserved.)
Resumo:
PURPOSE: To determine whether implantation of an intraocular lens (IOL) with an aspheric surface (Akreos AO, Bausch & Lomb Inc) results in reduced ocular aberrations (spherical aberration) and improved Strehl ratio and modulation transfer function (MTF) after cataract surgery. METHODS: In an intraindividual, randomized, double-masked, prospective study of 50 eyes (25 patients) with bilateral cataract, an IOL with modified anterior and posterior surfaces (Akreos AO) was implanted in one eye and a biconvex IOL with spherical surfaces (Akreos Fit, Bausch & Lomb Inc) implanted in the fellow eye. Ocular aberrations, Strehl ratio, and MTF curve with 4.5-, 5.0-, and 6.0-mm pupils were measured with a NIDEK OPD-Scan dynamic retinoscopy aberrometer 3 months after surgery. Uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively) were also measured. RESULTS: No statistically significant difference was noted between eyes in postoperative UDVA and CDVA at 1 month. At 3 months, the Akreos AO IOL group obtained statistically significant lower values of higher order and spherical aberrations with 4.5-, 5.0-, and 6.0-mm pupil diameters than the Akreos Fit IOL group (P<.05). The value of Strehl ratio was statistically significantly higher in eyes with the Akreos AO IOL for 4.5- and 6.0-mm pupils (P<.05). The MTF curve was better in the Akreos AO IOL group in 4.5-, 5.0-, and 6.0-mm pupils (P<.05). CONCLUSIONS: The aspheric Akreos AO IOL induced significantly less spherical aberration than the Akreos Fit IOL for 4.5-, 5.0-, and 6.0-mm pupils. Modulation transfer function and Strehl ratio were also better in eyes implanted with the Akreos AO IOL than the Akreos Fit. [J Refract Surg. 2011;27(4):287-292.] doi:10.3928/1081597X-20100714-01
Resumo:
Accurate iris reproduction in the fabrication of ocular prosthesis in order to match the remaining eye is a key factor to mask the loss and achieve an esthetic outcome for anophthalmic patients. This study evaluated the stability of acrylic paints used for replicating iris color in ocular prostheses by the analysis of two factors: the temperature of the acrylic resin polymerization cycle during prosthesis fabrication and the incidence of sun light, which is the main photodegrading agent undermining the longevity of ocular prostheses. An accelerated aging assay was used for both analyses. Specimens simulating the prosthetic iris in the colors blue, yellow, black, brown and green were fabricated, and were submitted to a colorimetric reading before and after undergoing the thermal conditions of acrylic resin polymerization. Next, the specimens were submitted to an artificial accelerated aging assay with ultraviolet radiation A and weekly colorimetric readings during a 3-week period. The color change (??*) values for the four specimens painted with the same color paint were averaged and the resulting values were considered for statistical analysis. Levine's test and Student's t-test were used to analyze the influence of the temperature of the polymerization cycle during prosthesis fabrication on the color stability of each acrylic resin paint. Friedman's test for three dependent samples was used for analysis of color photodegradation as function of time. Significance level was set at 0.05 for all analyses. It was observed that, after the action of the temperature of the polymerization cycle, alteration above clinically acceptable level of ??*> 3.3 was observed only for the yellow color. After the accelerated aging assay, there were statistically significant differences (p<0.05) as a function of time in the green, brown, black and blue colors. Changes were clinically acceptable for the brown and black colors; slightly above the clinically acceptable limit for the green color; and significantly high and impracticable from a clinical standpoint for the blue color. There was no statistically significant differences (p>0.05) for the yellow color, which presented color change only a little above the clinically acceptable limit. In conclusion: 1. Only the yellow color presented alterations above the clinically acceptable levels after the polymerization cycle; 2. After accelerated aging, there was no changes in the yellow color above the clinically acceptable levels; 3. For the green color, degradation was significant and slightly above the clinically acceptable levels; 4. The black, brown and blue colors presented significant alterations as function of time; the alterations of the brown and black colors were within acceptable clinical levels, while the blue color presented a more accentuated degradation over time.
Resumo:
Solanum lycocarpum A. St. Hil. (Solanaceae) is a hairy shrub or small much-branched tree of the Brazilian Cerrado. S. lycocarpum fruits are commonly used in traditional medicine in powder form or as folk preparations for the treatment of diabetes and obesity, as well as for controlling cholesterol levels. The aim of the present study was to chemically characterize the hydroalcoholic extract (SL) of S. lycocarpum by determination of total flavonoids and total poyphenols and quantification of steroidal alkaloids, as well as to evaluate its mutagenic and/or antimutagenic potential on V79 cells and Swiss mice using chromosomal aberrations and bone marrow micronucleus assays, respectively. Three concentrations of SL (16, 32, and 24 mu g/mL) were used for the evaluation of its mutagenic potential in V79 cells and four doses (0.25, 0.50, 1.0, and 2.0 g/kg body weight) were used for Swiss mice. In the antimutagenicity assays, the different concentrations of SL were combined with the chemotherapeutic agent doxorubicin (DXR). HPLC analysis of SL gave contents of 6.57% +/- 0.41 of solasonine and 4.60% +/- 0.40 of solamargine. Total flavonoids and polyphenols contents in SL were 0.04 and 3.60%, respectively. The results showed that not only SL exerted no mutagenic effect, but it also significantly reduced the frequency of chromosomal aberrations induced by DXR in both V79 cells and micronuclei in Swiss mice at the doses tested.
Resumo:
The aim of the present work was to obtain an ophthalmic delivery system with improved mechanical and mucoadhesive properties that could provide prolonged retention time for the treatment of ocular diseases. For this, an in situ forming gel comprised of the combination of a thermosetting polymer, poly (ethylene oxide)-poly (propylene oxide)-poly (ethylene oxide) (PEO-PPO-PEO, poloxamer), with a mucoadhesive agent (chitosan) was developed. Different polymer ratios were evaluated by oscillatory rheology, texture and mucoadhesive profiles. Scintigraphy studies in humans were conduced to verify the retention time of the formulations developed. The results showed that chitosan improves the mechanical strength and texture properties of poloxamer formulations and also confers mucoadhesive properties in a concentration-dependent manner. After a 10-min instillation of the poloxamer/chitosan 16:1 formulation in human eyes, 50-60% of the gel was still in contact with the cornea surface, which represents a fourfold increased retention in comparison with a conventional solution. Therefore, the developed formulation presented adequate mechanical and sensorial properties and remained in contact with the eye surface for a prolonged time. In conclusion, the in situ forming gel comprised of poloxamer/chitosan is a promising tool for the topical treatment of ocular diseases. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Sickle cell disease (SCD) is an inherited disorder caused by a single nucleotide substitution in the P-globin gene. The clinical heterogeneity observed in SCD patients has been attributed to environmental and genetic factors. The patients are subjected to increased oxidative stress, particularly during vaso-occlusive crises and acute chest pain. Another possible cause of oxidative stress in SCD is the high concentration of iron in the patients` plasma. The increase in oxidative stress could be a relevant risk factor for mutagenesis and carcinogenesis. Studies on the frequency of basal chromosomal aberrations in cultured lymphocytes from SCD patients have not been reported so far. In order to contribute to the understanding of the role of the different biomarkers and their relationship with the extremely variable clinical manifestation of SCD, we investigated the frequency of chromosome damage in peripheral lymphocytes from sickle cells patients and healthy controls. We found an increased frequency of chromosome damage and percentage of aberrant metaphases in these patients when compared with control subjects, even at basal values (p < 0.05). In the cytogenetic sensitivity assay, the results showed that these patients presented a marked decrease in the mitotic index values compared with healthy controls. Cisplatin-induced chromosomal damage in lymphocytes from these patients was significantly higher than the frequency measured in healthy controls. The results obtained in the present study showed that more investigations are needed in order to elucidate the susceptibility to genomic instability of SCD patients.
Resumo:
Background/Aims: It is a challenge to adapt traditional in vitro diffusion experiments to ocular tissue. Thus, the aim of this work was to present experimental evidence on the integrity of the porcine cornea, barrier function and maintenance of electrical properties for 6 h of experiment when the tissue is mounted on an inexpensive and easy-to-use in vitro model for ocular iontophoresis. Methods: A modified Franz diffusion cell containing two ports for the insertion of the electrodes and a receiving compartment that does not need gassing with carbogen was used in the studies. Corneal electron transmission microscopy images were obtained, and diffusion experiments with fluorescent markers were performed to examine the integrity of the barrier function. The preservation of the negatively charged corneal epithelium was verified by the determination of the electro-osmotic flow of a hydrophilic and non-ionized molecule. Results: The diffusion cell was able to maintain the temperature, homogenization, porcine epithelial corneal structure integrity, barrier function and electrical characteristics throughout the 6 h of permeation experiment, without requiring CO(2) gassing when the receiving chamber was filled with 25 m M of HEPES buffer solution. Conclusion: The system described here is inexpensive, easy to handle and reliable as an in vitro model for iontophoretic ocular delivery studies. Copyright (C) 2010 S. Karger AG, Basel
Resumo:
Previous studies have observed changes in the lacrimal gland and ocular surface related to diabetes mellitus and related it to insulin resistance or insufficiency and oxidative damage. The aim of this study was to evaluate whether insulin treatment inhibits those changes. Diabetes was induced in male Wistar rats with a single intravenous injection of streptozotocin and a subgroup was treated with insulin. After 5 and 10 weeks, the three groups (n = 5-10/group/experimental procedure) were compared for biochemical, functional, and histological parameters. After 5 weeks, changes in morphology and increased numbers of lipofucsin-like inclusions were observed in lacrimal glands of diabetic but not insulin-treated rats. After 5 weeks, malonaldehyde and total peroxidase activity were significantly higher in diabetic rats, but similar to control in insulin-treated diabetic rats (P = 0.03, P = 0.02, respectively). Our data indicate that diabetes induces histological alterations in lacrimal gland and suggests that hyperglycemia-related oxidative stress may participate in diabetic dry eye syndrome. Prevention by insulin replacement suggests direct hormone action and/or benefit by early sub optimal metabolic control.
Resumo:
Purpose To evaluate the ocular toxicity of escalating doses of intravitreous adalimumab (Humira) in the rabbit eye. Methods Twelve New Zealand albino rabbits received unilateral intravitreous injections of 0.1 ml of adalimumab 0.25 mg (three eyes), 0.50 mg (three eyes), 1.0 mg (three eyes) or 0.1 ml balanced salt solution (BSS, threeeyes). Slit-lamp biomicroscopy and fundoscopy were carried out at baseline, day 1, 7 and 14 following intravitreous injection, while electroretinography (ERG) was carried out at baseline and day 14. Animals were euthanized on day 14, and histopathological examination of the eyes was performed. Results Slit-lamp biomicroscopy and fundoscopy were normal in eyes having received BSS, 0.25 mg or 0.50 mg adalimumab; however, inflammation was present in two of three eyes having received 1.0 mg adalimumab. Similarly, comparison of scotopic and photopic ERG light at baseline and day 14 demonstrated no changes in eyes receiving BSS, 0.25 mg or 0.50 mg adalimumab, but two of three eyes having received 1.0 mg adalimumab showed a greater than 30% reduction in a and b wave. Finally, histopathology demonstrated no differences between eyes receiving BSS, 0.25 mg or 0.50 mg of adalimumab, but two of three eyes injected with 1.0 mg demonstrated inflammatory cell infiltration of the vitreous and anterior chamber, with one of these eyes demonstrating retinal necrosis. Conclusions Escalating doses of intravitreous adalimumab in rabbit eyes caused no detectable functional or structural ocular toxicity up to a dose of 0.50 mg. Administration of 1.0 mg in 0.1 ml was associated with an inflammatory reaction and retinal necrosis.
Resumo:
Introduction: Number 3 cleft or oral-nasal-ocular cleft is a well-known entity that was described by Morian over a century ago. This malformation is a paranasal-medial orbitomaxillary cleft running across the lacrimal segment of the lower eyelid and over the lacrimal groove. The Tessier number 3 naso-ocular cleft represents one of the most difficult and challenging malformations to correct for the reconstructive surgeon. We have conducted a retrospective analysis of our series consisting of 21 cases. Objective: The objective was to review the functional outcome and aesthetic results of the different techniques applied for each case. Materials and Methods: From 1997 to 2007, 21 patients with a Tessier number 3 cleft were treated in our craniofacial units. The clinical findings, tomographic studies, and surgical procedures were reviewed and analyzed. We have discussed our protocol of the treatment. Results: We have treated facial malformation in 2 craniofacial centers. Fourteen patients were evaluated in the first year of their life, with an average age at presentation of 3 years. Twelve patients were female, and 9 were male; 6 patients had amniotic bands in limbs, 5 patients had an association with Tessier number 11 cleft, 3 patients with number 9 cleft, and 1 with number 7 cleft. Related to cleft lip, 10 patients had bilateral cleft lip, and 8 patients had unilateral cleft lip. Three patients did not have any involvement of the upper lip. The alar base was deviated upward in 19 patients, 11 cases had severe anatomic alteration with the lateral border of the ala above the medial canthus, and 8 cases had a mild dislocation. Nine cases of lacrimal duct obstruction and 8 cases of lacrimal duct extrophy were identified. Twelve patients had a lower eyelid coloboma of varying grades, and there were 2 cases of microblepharia. Aiming the soft tissue reconstruction, eyelid, nose, and upper lip were evaluated regarding their position, absence of tissue, and position of medial canthus and ala. Twelve of our patients underwent correction in the same moment, their medial canthus rotated upward and the ala downward, using the contralateral side as the reference. The lip was treated using a Millard-like technique. Neo-conjunctivorhinostomy was performed in the same moment in 2 patients or later in 1 case. Four patients had plagiocephaly due to the cranial involvement, and they were submitted to cranioplasty. Three had neurosurgical approach and advancement of the frontal bandeau. One adult patient received an acrylic plate to reshape the frontal area. Conclusions: Tessier number 3 cleft is one of the most difficult and challenging malformations to correct for the reconstructive surgeon. Besides the difficulties of its treatment, patients with Tessier number 3 cleft may achieve good results when the team has good skills.
Resumo:
PURPOSE: To compare corneal reepithelialization, pain scores, ocular discomfort, and tear production after photorefractive keratectomy (PRK) and butterfly laser epithelial keratomileusis (LASEK). METHODS: This prospective, randomized, double-masked study comprised 102 eyes of 51 patients who underwent laser refractive surgery. Each patient was randomized to have one eye operated on with PRK and the other with butterfly LASEK. Patients were followed for 1 year. RESULTS: The mean reepithelialization time in the PRK group was 4.35 +/- 0.48 days (range: 4 to 5 days) and 4.75 +/- 0.72 days (range: 4 to 6 days) in the butterfly LASEK group (P<.002). Pain scores and ocular discomfort were not statistically different between groups, although a trend towards a lower pain level with PRK was noted (3.31 +/- 4.09 vs 4.43 +/- 4.27; P=.18). Schirmer test values were significantly reduced from preoperative levels through 12 months with both PRK (23.6 +/- 8.1 vs 19.4 +/- 10.1; P<.002) and butterfly LASEK (22.4 +/- 8.7 vs 18.9 +/- 9.7; P=.01); however, no difference between groups was noted at any time. CONCLUSIONS: Photorefractive keratectomy showed a modest but statistically significant shorter reepithelialization time and a tendency towards lower pain scores than butterfly LASEK. The reepithelialization time was strongly associated with the duration of surgery in both techniques. A similar reduction of Schirmer test values was observed up to 1 year postoperatively in both groups.
Resumo:
Congenital heart disease (CHD) is the most common birth defect and the leading cause of mortality in the first year of life. In fetuses with a heart defect, chromosomal abnormalities are very frequent. Besides aneuploidy, 22q11.2 deletion is one of the most recognizable chromosomal abnormalities causing CHD. The frequency of this abnormality varies in nonselected populations. This study aimed to investigate the incidence of the 22q11.2 deletion and other chromosomal alterations in a Brazilian sample of fetuses with structural cardiac anomalies detected by fetal echocardiography. In a prospective study, 68 fetuses with a heart defect were evaluated. Prenatal detection of cardiac abnormalities led to identification of aneuploidy or structural chromosomal anomaly in 35.3% of these cases. None of the fetuses with apparently normal karyotypes had a 22q11.2 deletion. The heart defects most frequently associated with chromosomal abnormalities were atrioventricular septal defect (AVSD), ventricular septal defect (VSD), and tetralogy of Fallot. Autosomal trisomies 18 and 21 were the most common chromosomal abnormalities. The study results support the strong association of chromosome alterations and cardiac malformation, especially in AVSD and VSD, for which a chromosome investigation is indicated. In fetuses with an isolated conotruncal cardiopathy, fluorescence in situ hybridization (FISH) to investigate a 22q11.2 deletion is not indicated.
Resumo:
Objectives: The purpose of this study was to explore the clinical relevance of chronic exposure to ambient levels of traffic derived air pollution on the ocular surface. Methods: A panel study involving 55 volunteers was carried out in Sao Paulo, Brazil. We measured the mean individual levels of nitrogen dioxide (NO(2)) exposure for 7 days. All subjects answered the Ocular Symptom Disease Index (OSDI) and a symptoms inventory. Subsequently, subjects underwent Schirmer I test, biomicroscopy, vital staining and tear breakup time (TOUT) assessment. Subject`s mean daily exposure to NO(2) was categorized in quartiles. Statistical analysis was performed using one-way ANOVA, Tukey HSD and Chi-Square tests. Results: A dose-response pattern was detected between OSDI scores and NO(2) quartiles (p < 0.05). There was a significant association between NO(2) quartiles and reported ocular irritation (X(2) = 9.2, p < 0.05) and a significant negative association between TBUT and NO(2) exposure (p < 0.05, R = -0.316. Spearman`s correlation). There was a significant increase in the frequency of meibomitis in subjects exposed to higher levels of NO(2) (p < 0.05). Conclusions: Subjects exposed to higher levels of traffic derived air pollution reported more ocular discomfort symptoms and presented greater tear film instability, suggesting that the ocular discomfort symptoms and tear breakup time could be used as convenient bioindicators of the adverse health effects of traffic derived air pollution exposure. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Objectives: We studied the neuroimaging and neurophysiological aspects of 17 patients with midline facial defects with ocular hypertelorism (MFDH). Methods: The investigation protocol included a previous semistructured questionnaire about family history; gestational, neonatal, and postnatal development; and dysmorphologic and neurologic evaluation. Recognized monogenic disorders and individuals with other well-known conditions were excluded. All patients had high resolution magnetic resonance imaging (MRI) with multiplanar reconstruction (MPR) and routine electroencephalograms (EEGs). Results: We detected abnormalities in five patients whose MRIs had been previously reported as normal. MRI showed central nervous system (CNS) structural abnormalities in all patients, which included commissural alterations in 16/17 (94%), malformations of cortical development in 10/17 (58%), disturbances of neural tube closure in 7/17(42%), and posterior fossa anomalies in 6/17 (35%). Some patients had more than one type of malformation occurring at different stages of the embryonary process. EEGs showed epileptiform activity in 4/17 (24%) and background abnormalities in 5/17 (29%) of patients. Conclusion: This study clearly demonstrated the presence of structural and functional neurologic alterations related to MFDH. Therefore, the CNS anomalies cannot be considered incidental findings but an intrinsic part of this condition, which could be related to environmental effects and/or genetic mutations. These findings would provide a basis for future investigations on MFDH and should also be considered when planning rehabilitation.