2 resultados para MECHANICAL STIMULI

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate the duration of the effect of mepivacaine when hyaluronidase is injected immediately prior to the end of pulpal anesthesia. Patients and Methods: Forty bilateral, symmetrical third molar surgeries were performed in 20 healthy patients. Inferior alveolar nerve block was induced using 2.8 mL 2% mepivacaine with epinephrine. Hyaluronidase (75 turbidity-reducing units) or a placebo was injected 40 minutes after the beginning of pulpar anesthesia (randomized and double-blind trial). The duration of effect in the pulpal and gingival tissues was evaluated by response to painful electrical stimuli applied to the Adjacent premolar, and by mechanical stimuli (pin prick) to the vestibular gingiva, respectively. Results: in both tissues, the duration of anesthetic effect with hyaluronidase was longer (P <.01) than with the placebo. Conclusion: Hyaluronidase increases the duration of mepivacaine in inferior alveolar nerve blocks. (c) 2008 American Association of Oral and Maxillofacial Surgeons.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cells are able to detect and respond to mechanical cues from their environment. Previous studies have investigated this mechanosensitivity on various cell types, including neural cells such as astrocytes. In this study, we have carefully optimized polyacrylamide gels, commonly used as compliant growth substrates, considering their homogeneity in surface topography, mechanical properties, and coating density, and identified several potential pitfalls for the purpose of mechanosensitivity studies. The resulting astrocyte response to growth on substrates with shear storage moduli of G` = 100 Pa and G` = 10 kPa was then evaluated as a function of coating density of poly-D-lysine using quantitative morphometric analysis. Astrocytes cultured on stiff substrates showed significantly increased perimeter, area, diameter, elongation, number of extremities and overall complexity if compared to those cultured on compliant substrates. A statistically significant difference in the overall morphological score was confirmed with an artificial intelligence-based shape analysis. The dependence of the cells` morphology on PDL coating density seemed to be weak compared to the effect of the substrate stiffness and was slightly biphasic, with a maximum at 10-100 mu g ml(-1) PDL concentration. Our finding suggests that the compliance of the surrounding tissue in vivo may influence astrocyte morphology and behavior.