198 resultados para Life Design

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: We analyzed the influence of IUGR on the concentrations of plasma (Znpl) and erythrocyte (Zne) zinc and on the ratios of Zne to Znpl (Zne:Znpl) and Zne to hemoglobin (Zne:Hb) in term infants during the first month of life. Design: Cohort study. Setting: Tertiary Care Neonatal Unit. Subjects: Exclusively breastfed term newborns (n = 84) were divided into 3 groups: group 1, without IUGR (n = 41), group II. with mild to moderate IUGR (n = 12). and group III, with severe IUGR (n = 31). IUGR was defined as birth weight under the 5th percentile of the Alexander et at curve and as a Kramer Index (KI: ratio of birth weight to estimated weight for each gestational age) <0.85. Severe IUGR was defined as a KI <0.75. Znpl, Zne. and Hb were measured at birth. 3 days, and 1 month of life. Results: Znpl tended to decrease (P = 0.073), Zne and Zne:Znpl increased (P < 0.001), and Hb decreased (P < 0.001) during the first month of life. There was not Znpl, Zne and Zne:Znpl time by group interaction. Zne:Hb increased (P < 0.001) during the first month of life and was lower in Group II at I month of age. Differences between Groups I and If (P = 0.017) and Groups II and III at I month of age (P = 0.011) were detected. Conclusions: Our results suggest that IUGR did not have association with erythrocyte zinc and Zne:Hb ratio at birth. However. neonatal nutrition could have influenced zinc incorporation during this period, through Zne increase.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To assess whether the -11391G > A polymorphism in the regulatory region of the adiponectin gene (ADIPOQ) is associated with birth size, postnatal growth, adiponectinemia, and cardiometabolic risk in adult life. Design: Case-control study nested within a prospective cohort of 2063 community subjects born in 1978/1979 and followed since birth to date. Methods: ADIPOQ -11391G > A genotype-phenotype associations were evaluated in 116 subjects born large for gestational age (LGA) and 392 gender-matched controls at birth (birth size), at 8-10 years (catch-down growth), and at 23-25 years of age (cardiometabolic profile). Results: The -11391A variant allele frequency was higher in LGA subjects (P=0.04). AA genotype was associated with augmented probability of being born LGA (odds ratio=4.14; 95% confidence interval: 1.16-16.7; P=0.03). This polymorphism was associated neither with body composition nor with postnatal growth pattern. At the age of 23-25 years, the -11391A variant allele was associated with higher serum adiponectin levels (GG: 10.7 +/- 6.2 versus GA: 12.2 +/- 6.5 versus AA: 14.2 +/- 6.8 mu g/ml; P < 0.01). Subjects born LGA presented higher body mass index (BMI; P=0.01), abdominal circumference (P=0.04), blood pressure (P=0.04), and homeostasis assessment model for insulin resistance (P=0.01) than adequate for gestational age. Symmetry at birth did not influence these variables. The occurrence of catch-down of weight was associated with lower BMI and abdominal circumference (P < 0.001) at 23-25 years. Conclusions: The -11391A ADIPOQ gene variant was associated with increased chance of being born LGA and with higher adiponectin levels in early adult life.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives: To evaluate the effect of framework design on the fatigue life and failure modes of metal ceramic (MC, Ni-Cr alloy core, VMK 95 porcelain veneer), glass-infiltrated alumina (ICA, In-Ceram Alumina/VM7), and veneered yttria-stabilized tetragonal zirconia polycrystals (Y-TZP, IPSe.max ZirCAD/IPS e.max,) crowns. Methods: Sixty composite resin tooth replicas of a prepared maxillary first molar were produced to receive crowns systems of a standard (MCs, ICAs, and Y-TZPs, n = 10 each) or a modified framework design (MCm, ICAm, and Y-TZPm, n = 10 each). Fatigue loading was delivered with a spherical steel indenter (3.18 mm radius) on the center of the occlusal surface using r-ratio fatigue (30-300 N) until completion of 10(6) cycles or failure. Fatigue was interrupted every 125,000 cycles for damage evaluation. Weibull distribution fits and contour plots were used for examining differences between groups. Failure mode was evaluated by light polarized and SEM microscopy. Results: Weibull analysis showed the highest fatigue life for MC crowns regardless of framework design. No significant difference (confidence bound overlaps) was observed between ICA and Y-TZP with or without framework design modification. Y-TZPm crowns presented fatigue life in the range of MC crowns. No porcelain veneer fracture was observed in the MC groups, whereas ICAs presented bulk fracture and ICAm failed mainly through the veneer. Y-TZP crowns failed through chipping within the veneer, without core fractures. Conclusions: Framework design modification did not improve the fatigue life of the crown systems investigated. Y-TZPm crowns showed comparable fatigue life to MC groups. Failure mode varied according to crown system. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cementitious stabilization of aggregates and soils is an effective technique to increase the stiffness of base and subbase layers. Furthermore, cementitious bases can improve the fatigue behavior of asphalt surface layers and subgrade rutting over the short and long term. However, it can lead to additional distresses such as shrinkage and fatigue in the stabilized layers. Extensive research has tested these materials experimentally and characterized them; however, very little of this research attempts to correlate the mechanical properties of the stabilized layers with their performance. The Mechanistic Empirical Pavement Design Guide (MEPDG) provides a promising theoretical framework for the modeling of pavements containing cementitiously stabilized materials (CSMs). However, significant improvements are needed to bring the modeling of semirigid pavements in MEPDG to the same level as that of flexible and rigid pavements. Furthermore, the MEPDG does not model CSMs in a manner similar to those for hot-mix asphalt or portland cement concrete materials. As a result, performance gains from stabilized layers are difficult to assess using the MEPDG. The current characterization of CSMs was evaluated and issues with CSM modeling and characterization in the MEPDG were discussed. Addressing these issues will help designers quantify the benefits of stabilization for pavement service life.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The purpose of this study was to evaluate the isolated and associated effects of estrogen therapy (estradiol valerate 1 mg/d orally) and physical exercise (moderate aerobic exercise, 3 h/wk) on health-related quality of life (HRQOL) and menopausal symptoms among women who had undergone hysterectomy. Design: A 6-month, randomized, double-blind, placebo-controlled clinical trial with 44 postmenopausal women who had undergone hysterectomy. The interventions were physical exercise and hormone therapy (n = 9), being sedentary and hormone therapy (n = 14), physical exercise and placebo (n = 11), and being sedentary and placebo (n = 10). HRQOL was assessed by a Brazilian standard version of the Medical Outcome Study Short-Forrn Health Survey and symptoms by Kupperman Index at baseline and after 6 months. Results: There was a decrease in symptoms in all groups, but only groups who performed physical exercise showed an increase in quality of life. Analysis of variance showed that changes in physical functioning (P = 0.001) and bodily pain (P = 0.012) scores over the 6-month period differed significantly between women who exercised and women who were sedentary, regardless of hormone therapy. Hormone therapy had no effect, and there was also no significant association between physical exercise and hormone therapy in HRQOL. Conclusions: Physical exercises can reduce menopausal symptoms and enhance HRQOL, independent of whether hormone therapy is taken.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Context: Mutations in TAC3 and TACR3 (encoding neurokinin B and its receptor) have been identified in Turkish patients with idiopathic hypogonadotropic hypogonadism (IHH), but broader populations have not yet been tested and genotype-phenotype correlations have not been established. Objective: A broad cohort of normosmic IHH probands was screened for mutations in TAC3/TACR3 to evaluate the prevalence of such mutations and define the genotype/phenotype relationships. Design and Setting: The study consisted of sequencing of TAC3/TACR3, in vitro functional assays, and neuroendocrine phenotyping conducted in tertiary care centers worldwide. Patients or Other Participants: 345 probands, 18 family members, and 292 controls were studied. Intervention: Reproductive phenotypes throughout reproductive life and before and after therapy were examined. Main Outcome Measure: Rare sequence variants in TAC3/TACR3 were detected. Results: In TACR3, 19 probands harbored 13 distinct coding sequence rare nucleotide variants [three nonsense mutations, six nonsynonymous, four synonymous (one predicted to affect splicing)]. In TAC3, one homozygous single base pair deletion was identified, resulting in complete loss of the neurokinin B decapeptide. Phenotypic information was available on 16 males and seven females with coding sequence variants in TACR3/TAC3. Of the 16 males, 15 had microphallus; none of the females had spontaneous thelarche. Seven of the 16 males and five of the seven females were assessed after discontinuation of therapy; six of the seven males and four of the five females demonstrated evidence for reversibility of their hypogonadotropism. Conclusions: Mutations in the neurokinin B pathway are relatively common as causes of hypogonadism. Although the neurokinin B pathway appears essential during early sexual development, its importance in sustaining the integrity of the hypothalamic-pituitary-gonadal axis appears attenuated over time. (J Clin Endocrinol Metab 95: 2857-2867, 2010)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To determine the mass of colostrum ingested by exclusively breastfed newborn infants during the first 24 hours of extrauterine life. Study design Milk ingested during the first 24 hours of life by 90 healthy newborn infants was evaluated by use of a scale with high sensitivity. The masses were measured during 8-hour periods. Associations of the mass measured with prenatal and postnatal variables were tested. Results The mass of colostrum ingested was evaluated in 307 feedings, with 3.4 +/- 1 feedings recorded per 8-hour period of observation. Mean gain per feeding was 1.5 +/- 1.1 g. The daily mass of milk ingested by newborn infants was estimated at 15 +/- 11 g. This volume did not show a tendency to increase during the first 24 postnatal hours, nor was it related to perinatal or postnatal factors or to breastfeeding time. Conclusions During the first 24 hours of life newborns ingested 15 +/- 11 g of milk. (J Pediatr 2010; 156: 29-32).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Child oral health-related quality of life (COHRQoL) has been increasingly assessed; however, few studies appraised the influence of socioeconomic status on COHRQoL in developing countries. This study assessed the relationship of COHRQoL with socioeconomic backgrounds and clinical factors. This study followed a cross-sectional design, with a multistage random sample of 792 schoolchildren aged 12 years, representative of Santa Maria, a southern city in Brazil. Participants completed the Brazilian version of the Child Perceptions Questionnaire (CPQ(11-14)), their parents or guardians answered questions on socioeconomic status, and a dental examination provided information on the prevalence of caries, dental trauma and occlusion. The assessment of association used hierarchically adjusted Poisson regression models. Higher impacts on COHRQoL were observed for children presenting with untreated dental caries (RR 1.20; 95% CI 1.07-1.35) and maxillary overjet (RR 1.19; 95% CI 1.02-1.40). Socioeconomic factors also associated with COHRQoL; poorer scores were reported by children whose mothers have not completed primary education (RR 1.30; 95% CI 1.17-1.44) and those with lower household income (RR 1.13; 95% CI 1.02-1.26). Poor socioeconomic standings and poor dental status have a negative impact on COHRQoL; reducing health inequalities may demand dental programmes and policies targeting deprived population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the incidence of life support limitation and medical practices in the last 48 hrs of life of children in seven Brazilian pediatric intensive care units (PICUs). Design. Cross-sectional multicenter retrospective study based on medical chart review. Setting: Seven PICUs belonging to university and tertiary hospitals located in three Brazilian regions: two in Porto Alegre (southern region), two in Sao Paulo (southeastern region), and three in Salvador (northeastern region). Patients. Medical records of all children who died in seven PICUs from January 2003 to December 2004. Deaths in the first 24 hrs of admission to the PICU and brain death were excluded. Interventions: Two pediatric intensive care residents from each PICU were trained to fill out a standard protocol (K = 0.9) to record demographic data and all medical management provided in the last 48 hrs of life (inotropes, sedatives, mechanical ventilation, full resuscitation maneuvers or not). Student`s t-test, analysis of variance, chi-square test, and relative risk were used for comparison of data. Measurements and Main Results. Five hundred and sixty-one deaths were identified; 97 records were excluded (61 because of brain death and 36 due to <24 hrs in the PICU). Thirty-six medical charts could not be found. Cardiopulmonary resuscitation was performed in 242 children (57%) with a significant difference between the southeastern and northeastern regions (p =.0003). Older age (p = .025) and longer PICU stay (p = .001) were associated with do-not-resuscitate orders. In just 52.5% of the patients with life support limitation, the decision was clearly recorded in the medical chart. No ventilatory support was provided in 14 cases. Inotropic drug infusions were maintained or increased in 66% of patients with do-not-resuscitate orders. Conclusions. The incidence of life support limitation has increased among Brazilian PICUs but with significant regional differences. Do-not-resuscitate orders are still the most common practice, with scarce initiatives for withdrawing or withholding life support measures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Kidney transplantation improves the quality of life of end-stage renal disease patients. The quality of life benefits, however, pertain to patients on average, not to all transplant recipients. The aim of this study was to identify factors associated with health-related quality of life after kidney transplantation. Population-based study with a cross-sectional design was carried out and quality of life was assessed by SF-36 Health Survey Version 1. A multivariate linear regression model was constructed with sociodemographic, clinical and laboratory data as independent variables. Two hundred and seventy-two kidney recipients with a functioning graft were analyzed. Hypertension, diabetes, higher serum creatinine and lower hematocrit were independently and significantly associated with lower scores for the SF-36 oblique physical component summary (PCSc). The final regression model explained 11% of the PCSc variance. The scores of oblique mental component summary (MCSc) were worse for females, patients with a lower income, unemployed and patients with a higher serum creatinine. The regression model explained 9% of the MCSc variance. Among the studied variables, comorbidity and graft function were the main factors associated with the PCSc, and sociodemographic variables and graft function were the main determinants of MCSc. Despite comprehensive, the final regression models explained only a little part of the heath-related quality of life variance. Additional factors, such as personal, environmental and clinical ones might influence quality of life perceived by the patients after kidney transplantation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Over the useful life of a LAN, network downtimes will have a negative impact on organizational productivity not included in current Network Topological Design (NTD) problems. We propose a new approach to LAN topological design that includes the impact of these productivity losses into the network design, minimizing not only the CAPEX but also the expected cost of unproductiveness attributable to network downtimes over a certain period of network operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For centuries, specific instruments or regular toothbrushes have routinely been used to remove tongue biofilm and improve breath odor. Toothbrushes with a tongue scraper on the back of their head have recently been introduced to the market. The present study compared the effectiveness of a manual toothbrush with this new design, i.e., possessing a tongue scraper, and a commercial tongue scraper in improving breath odor and reducing the aerobic and anaerobic microbiota of tongue surface. The evaluations occurred at 4 moments, when the participants (n=30) had their halitosis quantified with a halimeter and scored according to a 4-point scoring system corresponding to different levels of intensity. Saliva was collected for counts of aerobic and anaerobic microorganisms. Data were analyzed statistically by Friedman's test (p<0.05). When differences were detected, the Wilcoxon test adjusted for Bonferroni correction was used for multiple comparisons (group to group). The results confirmed the importance of mechanical cleaning of the tongue, since this procedure provided an improvement in halitosis and reduction of aerobe and anaerobe counts. Regarding the evaluated methods, the toothbrush's tongue scraper and conventional tongue scraper had a similar performance in terms of breath improvement and reduction of tongue microbiota, and may be indicated as effective methods for tongue cleaning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study ascertained whether under dental erosion models that closely mimics the real-life situation enamel and root dentin from bovine origin would be reliable substitutes for human counterparts. Through a 2x2 crossover design, in a first trial, 14 volunteers wore a palatal device containing slabs of bovine and human enamel. Half of the participants ingested (4x daily, for 10 days) orange juice first, crossing over to mineral water, while the remainder received the reverse sequence. In a second trial, volunteers wore devices with slabs of bovine and human root dentin. Except for the duration of each intraoral phase, which lasted 2 rather 10 days, the experiment with root dentin run exactly as for enamel. Dental substrates were analyzed for surface microhardness. Two-way ANOVAs (α=0.05) indicated no difference between the microhardness values recorded for human and bovine enamel (p=0.1350), but bovine root dentin had lower microhardness compared to its human counterpart (p=0.0432). While bovine enamel can reliably substitute its human counterpart in in situ dental erosion models, bovine root dentin does not seem to be a viable alternative to the corresponding human tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accelerated stability tests are indicated to assess, within a short time, the degree of chemical degradation that may affect an active substance, either alone or in a formula, under normal storage conditions. This method is based on increased stress conditions to accelerate the rate of chemical degradation. Based on the equation of the straight line obtained as a function of the reaction order (at 50 and 70 ºC) and using Arrhenius equation, the speed of the reaction was calculated for the temperature of 20 ºC (normal storage conditions). This model of accelerated stability test makes it possible to predict the chemical stability of any active substance at any given moment, as long as the method to quantify the chemical substance is available. As an example of the applicability of Arrhenius equation in accelerated stability tests, a 2.5% sodium hypochlorite solution was analyzed due to its chemical instability. Iodometric titration was used to quantify free residual chlorine in the solutions. Based on data obtained keeping this solution at 50 and 70 ºC, using Arrhenius equation and considering 2.0% of free residual chlorine as the minimum acceptable threshold, the shelf-life was equal to 166 days at 20 ºC. This model, however, makes it possible to calculate shelf-life at any other given temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of specimens' design and manufacturing process on microtensile bond strength, internal stress distributions (Finite Element Analysis - FEA) and specimens' integrity by means of Scanning Electron Microscopy (SEM) and Laser Scanning Confocal Microscopy (LCM). Excite was applied to flat enamel surface and a resin composite build-ups were made incrementally with 1-mm increments of Tetric Ceram. Teeth were cut using a diamond disc or a diamond wire, obtaining 0.8 mm² stick-shaped specimens, or were shaped with a Micro Specimen Former, obtaining dumbbell-shaped specimens (n = 10). Samples were randomly selected for SEM and LCM analysis. Remaining samples underwent microtensile test, and results were analyzed with ANOVA and Tukey test. FEA dumbbell-shaped model resulted in a more homogeneous stress distribution. Nonetheless, they failed under lower bond strengths (21.83 ± 5.44 MPa)c than stick-shaped specimens (sectioned with wire: 42.93 ± 4.77 MPaª; sectioned with disc: 36.62 ± 3.63 MPa b), due to geometric irregularities related to manufacturing process, as noted in microscopic analyzes. It could be concluded that stick-shaped, nontrimmed specimens, sectioned with diamond wire, are preferred for enamel specimens as they can be prepared in a less destructive, easier, and more precise way.