105 resultados para Intraclass Correlation Coefficient
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
OBJECTIVE: The aim of this study was to translate the Structured Clinical Interview for Mood Spectrum into Brazilian Portuguese, measuring its reliability, validity, and defining scores for bipolar disorders. METHOD: Questionnaire was translated (into Brazilian Portuguese) and back-translated into English. Sample consisted of 47 subjects with bipolar disorder, 47 with major depressive disorder, 18 with schizophrenia and 22 controls. Inter-rater reliability was tested in 20 subjects with bipolar disorder and MDD. Internal consistency was measured using the Kuder Richardson formula. Forward stepwise discriminant analysis was performed. Scores were compared between groups; manic (M), depressive (D) and total (T) threshold scores were calculated through receiver operating characteristic (ROC) curves. RESULTS: Kuder Richardson coefficients were between 0.86 and 0.94. Intraclass correlation coefficient was 0.96 (CI 95 % 0.93-0.97). Subjects with bipolar disorder had higher M and T, and similar D scores, when compared to major depressive disorder (ANOVA, p < 0.001). The sub-domains that best discriminated unipolar and bipolar subjects were manic energy and manic mood. M had the best area under the curve (0.909), and values of M equal to or greater than 30 yielded 91.5% sensitivity and 74.5% specificity. CONCLUSION: Structured Clinical Interview for Mood Spectrum has good reliability and validity. Cut-off of 30 best differentiates subjects with bipolar disorder vs. unipolar depression. A cutoff score of 30 or higher in the mania sub-domain is appropriate to help make a distinction between subjects with bipolar disorder and those with unipolar depression.
Resumo:
OBJETIVO: Avaliar a confiabilidade do questionário Lista de Atividades Físicas em crianças. MÉTODOS: O estudo é parte da adaptação transcultural do questionário, realizado com 83 escolares de sete a dez anos, matriculados do segundo ao quinto ano do ensino fundamental da cidade de São Paulo, SP, em 2008. O questionário foi respondido pela criança por meio de entrevista individual, apresenta lista com 21 atividades físicas moderadas a vigorosas realizadas no dia anterior, é dividido em períodos (antes, durante e após a escola) e possui seção de avaliação da entrevista. O questionário permite quantificar: tempo em atividades físicas e sedentárias; e custos metabólicos total e ponderado. A confiabilidade foi avaliada comparando-se duas entrevistas realizadas com intervalo médio de três horas. Para a seção C (avaliação da entrevista), compararam-se dados da primeira entrevista e de um avaliador externo. Utilizaram-se a proposta de Bland & Altman e os coeficientes de correlação intraclasse e de correlação de concordância de Lin na avaliação da confiabilidade. RESULTADOS: Os limites inferiores dos coeficientes de correlação intraclasse para os desfechos analisados variaram de 0,84 a 0,96. A precisão e concordância variaram, respectivamente, de 0,83 a 0,97 e de 0,99 a 1. A reta estimada a partir de pares de valores obtidos nas duas aplicações para atividade física indica elevada precisão dos dados. O item da entrevista com pior resultado foi a habilidade em estimar tempo (regular em 27,7% das entrevistas). Os itens da seção C apresentaram coeficientes de correlação intraclasse entre 0,60 e 0,70, exceto o nível de cooperação (0,46). CONCLUSÕES: A Lista de Atividades Físicas apresenta alta confiabilidade para aferir atividade física e sedentária do dia anterior em crianças.
Resumo:
OBJECTIVES: to produce evidence of the validity and reliability of the Body Shape Questionnaire (BSQ) - a tool for measuring an individual's attitude towards his or her body image. METHODS: the study covered 386 young people of both sexes aged between 10 and 18 from a private school and used self-applied questionnaires and anthropometric evaluation. It evaluated the internal consistency, the discriminant validity for differences from the means, according to nutritional status (underweight, eutrophic, overweight and obese), the concurrent validity by way of Spearman's correlation coefficient between the scale and the Body Mass Index (BMI), the waist-hip circumference ratio (WHR) and the waist circumference (WC). Reliability was tested using Wilcoxon's Test, the intraclass correlation coefficient and the Bland-Altman figures. RESULTS: the BSQ displayed good internal consistency (±=0.96) and was capable of discriminating among the total population, boys and girls, according to nutritional status (p<0.001). It correlated with the BMI (r=0.41; p<0.001), WHR (r=-0.10; p=0.043) and WC (r=0.24; p<0.001) and its reliability was confirmed by intraclass correlation (r=0.91; p<0.001) for the total population. The questionnaire was easy to understand and could be completed quickly. CONCLUSIONS: the BSQ presented good results, thereby providing evidence of its validity and reliability. It is therefore recommended for evaluation of body image attitudes among adolescents.
Resumo:
OBJETIVO:Validar escala de insatisfação corporal para adolescentes. MÉTODOS: Participaram do estudo 386 adolescentes, de ambos os sexos, entre dez e 17 anos de idade, de uma escola particular de ensino fundamental e médio, de São Bernardo do Campo, SP, em 2006. Foram realizadas tradução e adaptação cultural da "Escala de Evaluación de Insatisfación Corporal para Adolescentes" para o português. Foram avaliadas consistência interna por meio do coeficiente alfa de Cronbach, análise fatorial pelo método Varimax e validade discriminante pelas diferenças entre médias de estado nutricional, utilizando-se o teste de Kruskal-Wallis. Na validação concorrente, calculou-se o coeficiente de correlação de Spearman entre a escala e o índice de massa corporal, a razão circunferência quadril e a circunferência da cintura. Para reprodutibilidade, foram utilizados o teste de Wilcoxon, o coeficiente de correlação intra-classe. RESULTADOS: A escala traduzida não apresentou discordâncias significativas com a original. A escala apresentou consistência interna satisfatória para todos os subgrupos estudados (fases inicial e intermediária de adolescência, ambos os sexos) e foi capaz de discriminar os adolescentes segundo o estado nutricional. Na análise concorrente, as três medidas corporais foram correlacionadas, exceto adolescentes do sexo masculino em fase inicial, e sua reprodutibilidade foi confirmada. CONCLUSÕES: A Escala de Avaliação da Insatisfação Corporal para Adolescentes está traduzida e adaptada para o português e apresentou resultados satisfatórios, sendo recomendada para avaliação do aspecto atitudinal da imagem corporal de adolescentes.
Resumo:
Objective: To measure condylar displacement between centric relation (CR) and maximum intercuspation (MIC) in symptomatic and asymptomatic subjects. Materials and Methods: The sample comprised 70 non-deprogrammed individuals, divided equally into two groups, one symptomatic and the other asymptomatic, grouped according to the research diagnostic criteria for temporomandibular disorders (RDC/TMD). Condylar displacement was measured in three dimensions with the condylar position indicator (CPI) device. Dahlberg's index, intraclass correlation coefficient, repeated measures analysis of variance, analysis of variance, and generalized estimating equations were used for statistical analysis. Results: A greater magnitude of difference was observed on the vertical plane on the left side in both symptomatic and asymptomatic individuals (P = .033). The symptomatic group presented higher measurements on the transverse plane (P = .015). The percentage of displacement in the mesial direction was significantly higher in the asymptomatic group than in the symptomatic one (P = .049). Both groups presented a significantly higher percentage of mesial direction on the right side than on the left (P = .036). The presence of bilateral condylar displacement (left and right sides) in an inferior and distal direction was significantly greater in symptomatic individuals (P = .012). However, no statistical difference was noted between genders. Conclusion: Statistically significant differences between CR and MIC were quantifiable at the condylar level in asymptomatic and symptomatic individuals. (Angle Orthod. 2010;80:835-842.)
Resumo:
We evaluated the reliability and validity of a Brazilian-Portuguese version of the Epilepsy Medication Treatment Complexity Index (EMTCI). Interrater reliability was evaluated with the intraclass correlation coefficient (ICC), and validity was evaluated by correlation of mean EMTCI scores with the following variables: number of antiepileptic drugs (AEDs), seizure control, patients` perception of seizure control, and adherence to the therapeutic regimen as measured with the Morisky scale. We studied patients with epilepsy followed in a tertiary university-based hospital outpatient clinic setting, aged 18 years or older, independent in daily living activities, and without cognitive impairment or active psychiatric disease. ICCs ranged from 0.721 to 0.999. Mean EMTCI scores were significantly correlated with the variables assessed. Higher EMTCI scores were associated with an increasing number of AEDs, uncontrolled seizures, patients` perception of lack of seizure control, and poorer adherence to the therapeutic regimen. The results indicate that the Brazilian-Portuguese EMTCI is reliable and valid to be applied clinically in the country. The Brazilian-Portuguese EMTCI version may be a useful tool in developing strategies to minimize treatment complexity, possibly improving seizure control and quality of life in people with epilepsy in our milieu. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
To evaluate the correlation between intraocular pressure (IOP) rise, ocular pulse amplitude (OPA), and choroidal thickness (ChT) during the water drinking test (WDT). Primary open-angle glaucoma (POAG) patients were submitted to the WDT followed by serial IOP measurements using dynamic contour tonometry (DCT), Goldman tonometry (GAT), and ChT measurements using ultrasonographic A and B-scan (USG). A control group not submitted to the test was also evaluated using DCT, GAT, and USG. Intraclass correlation coefficient (ICC) was calculated in the control group in order to assess the reproducibility of measurements. Spearman`s coefficient (rho) was used to assess the correlation between the variables. Thirty eyes were included in the study. There was a significant IOP rise during the WDT using both GAT and DCT (p < 0.001). The OPA and ChT measurements also increased significantly (p < 0.001). Spearman`s correlation between the OPA values and ChT measurements was significant and moderate (rho = 0.40, p = 0.005). The average increase of OPA and ChT measurements occurred 15 min before the IOP rise. There was a significant increase of OPA and ChT measurements followed by an IOP rise during the WDT. Increased choroidal volume due to hemodynamic forces may be enrolled in the mechanism of IOP elevation during this stress test.
Resumo:
Background: The perception of improvement by a patient has assumed a central role in functional evaluation after a variety of knee problems. One of the instruments most used in clinical research is the International Knee Documentation Committee (IKDC) Subjective Knee Form because its psychometric properties are considered to be excellent. Nonetheless, this questionnaire was originally developed for use in the English language. Therefore, to use this questionnaire in the Brazilian population, it is essential to translate and validate it. Purpose: The aim of this study was to translate the IKDC Subjective Knee Form into a Brazilian version and to test its validity and reproducibility. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: The translation of the original IKDC Subjective Knee Form into a Brazilian version was accomplished in accordance with the American Orthopaedic Society for Sports Medicine guidelines and was tested in 32 patients with knee pathologic conditions to develop the first Brazilian version. To test validity and reproducibility, 117 patients with several knee complaints completed the Brazilian IKDC Subjective Knee Form, the Short Form 36 (SF-36), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Lysholm score. From these patients, 85 were retested within a week to achieve reproducibility. The validation was addressed by correlating the Brazilian IKDC Subjective Knee Form to the other outcome measures. The reproducibility was tested by measuring internal consistency, test-retest reliability, and agreement. Results: The Brazilian IKDC Subjective Knee Form was highly related to the physical component summary of the SF-36, the Lysholm score, and the WOMAC, and weakly related to the mental component summary of SF-36 (r=.79, .89, .85, and .51, respectively). The internal consistency was strong, with a Cronbach a value of .928 and .935 in the test and retest assessment, respectively. The test-retest reliability proved to be excellent, with a high value of the intraclass correlation coefficient (.988), as well as the agreement, demonstrated by the low differences between the means of the test and retest, and the short limit of agreement, observed in the Altman-Bland and survival-agreement plots. Conclusion: The results of this study provide evidence that the Brazilian IKDC Subjective Knee Form has psychometric properties similar to the original version. In addition, it was a reliable evaluation instrument for patients with knee-related problems.
Resumo:
The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Objective: The Purpose of this study was to determine whether handedness influences bilateral shoulder range of motion in nonathlete adult women. Methods: This was an observational Study. Shoulder range of motion (flexion, abduction, horizontal adduction, extension, external and internal rotation) was passively and bilaterally measured in 50 female, right-handed, and healthy university students, ranging from 20 to 29 years of age, who were not practicing repetitive activities with the upper limbs at the time Of this study. The assessment was performed with a universal goniometer, twice for each subject by the same examiner. irst and second measurements were correlated using the intraclass correlation coefficient, which was high for all movements and ranged from 0.80 to 0.97. The Student t test and Wilcoxon test were used to compare the range of motion between the dominant and nondominant shoulders and the mean differences between the 2 sides. The effect of size vias alpha = .05. Results: There is statistically significance difference between the 2 sides when the rotational range of motion is compared the dominant shoulder presented increased external rotation (mean, 4.74 degrees; 95% confidence interval, 1.61-7.87) and decreased internal rotation (mean, 3.52 degrees; 95% confidence interval, 1.64-5.4) compared to the opposite Shoulder. Conclusion: Dominance should be considered when shoulder rotation is evaluated even in nonathlete adult women. (J Manipulative Physiol Ther 2009;32:149-153)
Resumo:
The purpose of the present study was to evaluate the intra and interday reliability of surface electromyographic amplitude values of the scapular girdle muscles and upper limbs during 3 isometric closed kinetic chain exercises, involving upper limbs with the fixed distal segment extremity on stable base of support and on a Swiss ball (relatively unstable). Twenty healthy adults performed the exercises push-up, bench-press and wall-press with different effort levels (80% and 100% maximal load). Subjects performed three maximal voluntary contractions (MVC) in muscular testing position of each muscle to obtain a reference value for root mean square (RMS) normalization. Individuals were instructed to randomly perform three isometric contraction series, in which each exercise lasted 6 s with a 2-min resting-period between series and exercises. Intra and interday reliabilities were calculated through the intraclass correlation coefficient (ICC 2.1), standard error of the measurement (SEM). Results indicated an excellent intraday reliability of electromyographic amplitude values (ICC >= 0.75). The interday reliability of normalized RMS values ranged between good and excellent (ICC 0.52-0.98). Finally, it is suggested that the reliability of normalized electromyographic amplitude values of the analyzed muscles present better values during exercises on a stable surface. However, load levels used during the exercises do not seem to have any influence on variability levels, possibly because the loads were quite similar. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
In adolescent idiopathic scoliosis (AIS) there has been a shift towards increasing the number of implants and pedicle screws, which has not been proven to improve cosmetic correction. To evaluate if increasing cost of instrumentation correlates with cosmetic correction using clinical photographs. 58 Lenke 1A and B cases from a multicenter AIS database with at least 3 months follow-up of clinical photographs were used for analysis. Cosmetic parameters on PA and forward bending photographs included angular measurements of trunk shift, shoulder balance, rib hump, and ratio measurements of waist line asymmetry. Pre-op and follow-up X-rays were measured for coronal and sagittal deformity parameters. Cost density was calculated by dividing the total cost of instrumentation by the number of vertebrae being fused. Linear regression and spearman`s correlation were used to correlate cost density to X-ray and photo outcomes. Three independent observers verified radiographic and cosmetic parameters for inter/interobserver variability analysis. Average pre-op Cobb angle and instrumented correction were 54A degrees (SD 12.5) and 59% (SD 25) respectively. The average number of vertebrae fused was 10 (SD 1.9). The total cost of spinal instrumentation ranged from $6,769 to $21,274 (Mean $12,662, SD $3,858). There was a weak positive and statistically significant correlation between Cobb angle correction and cost density (r = 0.33, p = 0.01), and no correlation between Cobb angle correction of the uninstrumented lumbar spine and cost density (r = 0.15, p = 0.26). There was no significant correlation between all sagittal X-ray measurements or any of the photo parameters and cost density. There was good to excellent inter/intraobserver variability of all photographic parameters based on the intraclass correlation coefficient (ICC 0.74-0.98). Our method used to measure cosmesis had good to excellent inter/intraobserver variability, and may be an effective tool to objectively assess cosmesis from photographs. Since increasing cost density only improves mildly the Cobb angle correction of the main thoracic curve and not the correction of the uninstrumented spine or any of the cosmetic parameters, one should consider the cost of increasing implant density in Lenke 1A and B curves. In the area of rationalization of health care expenses, this study demonstrates that increasing the number of implants does not improve any relevant cosmetic or radiographic outcomes.
Resumo:
Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
Objective. Endothelial impairment evaluation by sonographic measurement of flow-mediated dilatation (FMD) has become broadly used. However, this method has 2 main caveats: the dilatation depends on the baseline arterial diameter, and a high precision level is required. Vasodilatation leads to an amplified fall in impedance. We hypothesized that assessment of the pulsatility index change (PI-C) 1 minute after 5-minute forearm compression might evaluate that fall in impedance. The aim of this study was to compare the PI-C with FMD. Methods. Flow-mediated dilatation and the PI-C were assessed in 51 healthy women aged between 35.1 and 67.1 years. We correlated both FMD and the PI-C with age, body mass index, waist circumference, cholesterol level, high-density lipoprotein level, glucose level, systolic and diastolic blood pressure, pulse pressure, brachial artery diameter, simplified Framingham score, intima-media thickness, and carotid stiffness index. Intraclass correlation coefficients between 2 FMD and PI-C measurements were also examined. Results. Only FMD correlated with baseline brachial diameter (r=-0.53). The PI-C had a high correlation with age, body mass index, waist circumference, cholesterol level, systolic blood pressure, pulse pressure, simplified Framingham score, and intima-media thickness. The correlation between FMD and the PI-C was high (r=-0.66). The PI-C had a higher intraclass correlation coefficient (0.991) than FMD (0.836) but not brachial artery diameter (0.989). Conclusions. The PI-C had a large correlation with various markers of cardiovascular risk. Additionally, PI-C measurement does not require offline analysis, extra software, or electrocardiography We think that the PI-C could be considered a marker of endothelial function. However, more studies are required before further conclusions.
Resumo:
The mechanical alterations related to the excessive use of accessory respiratory muscles and the mouth breathing observed in children with asthma may lead to the development of alterations in head posture, shoulders, thoracic region and, consequently, in alterations of body posture. The purpose of this study was to assess body posture changes of children with asthma compared to a non-asthmatic control group matched for gender, age, weight, and height. Thirty children with asthma and 30 non-asthmatic children aged 7 to 12 years were enrolled in this study. Digital photographic records were obtained for analysis of the body posture of the children by computed photogrammetry. The intraclass correlation coefficient and Student`s t test (p < 0.05) were used for statistical analysis. There were no significant differences between groups for the angles analyzed, except for the knee flexor angle. These results demonstrate that children with asthma did not present postural alterations compared to non-asthmatic controls since the only angle for which there was a significant difference between groups showed weak reproducibility. The findings of this study do not support the notion that children with asthma present alterations in body posture.