9 resultados para Enthalpy calibration

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assembling of a system for field sampling and activity concentration measurement of radon dissolved in groundwater is described. Special attention is given in presenting the calibration procedure to obtain the radon activity concentration in groundwater from the raw counting rate registered in a portable scintillation detector and in establishing the precision of the activity concentration measurements. A field procedure was established and the system tested during one year of monthly observations of (222)Rn activity concentration in groundwater drawn from two wells drilled on metamorphic rocks exposed at Eastern Sao Paulo State, Brazil. The observed mean (222)Rn activity concentrations are 374 Bq/dm(3) in one well and about 1275 Bq/dm(3) in the other one. In both wells the (222)Rn activity concentrations showed a seasonal variation similar to variations previously reported in the literature for the same region. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this paper is to discuss maximum likelihood inference for the comparative structural calibration model (Barnett, in Biometrics 25:129-142, 1969), which is frequently used in the problem of assessing the relative calibrations and relative accuracies of a set of p instruments, each designed to measure the same characteristic on a common group of n experimental units. We consider asymptotic tests to answer the outlined questions. The methodology is applied to a real data set and a small simulation study is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Corumba Group cropping out in the southern Paraguay Belt in Brazil is one of the most complete Ediacaran sedimentary archives of palaeogeographic climatic biogeochemical and biotic evolution in southwestern Gondwana The unit hosts a rich fossil record including acritarchs vendotaenids (Vendo taenia Eoholynia) soft-bodied metazoans (Corumbella) and skeletal fossils (Cloudina Titanotheca) The Tamengo Formation made up mainly of limestones and marls provides a rich bio- and chemostratigraphic record Several outcrops formerly assigned to the Cuiaba Group are here included in the Tamengo Formation on the basis of lithological and chemostratigraphical criteria High-resolution carbon isotopic analyses are reported for the Tamengo Formation showing (from base to top) (1) a positive delta(13)C excursion to +4 parts per thousand PDB above post-glacial negative values (2) a negative excursion to -3 5 parts per thousand associated with a marked regression and subsequent transgression (3) a positive excursion to +5 5 parts per thousand and (4) a plateau characterized by delta(13)C around +3 parts per thousand A U-Pb SHRIMP zircon age of an ash bed Interbedded in the upper part of the delta(13)C positive plateau yielded 543 +/- 3 Ma which is considered as the depositional age (Babinski et al 2008a) The positive plateau in the upper Tamengo Formation and the preceding positive excursion are ubiquitous features in several successions worldwide including the Nama Group (Namibia) the Dengying Formation (South China) and the Nafun and Ara groups (Oman) This plateau is constrained between 542 and 551 Ma thus consistent with the age of the upper Tamengo Formation The negative excursion of the lower Tamengo Formation may be correlated to the Shuram-Wonoka negative anomaly although delta(13)C values do not fall beyond -3 5 parts per thousand in the Brazilian sections Sedimentary breccias occur just beneath this negative excursion in the lower Tamengo Formation One possible interpretation of the origin of these breccias is a glacioeustatic sea-level fall but a tectonic interpretation cannot be completely ruled out Published by Elsevier B V

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In chemical analyses performed by laboratories, one faces the problem of determining the concentration of a chemical element in a sample. In practice, one deals with the problem using the so-called linear calibration model, which considers that the errors associated with the independent variables are negligible compared with the former variable. In this work, a new linear calibration model is proposed assuming that the independent variables are subject to heteroscedastic measurement errors. A simulation study is carried out in order to verify some properties of the estimators derived for the new model and it is also considered the usual calibration model to compare it with the new approach. Three applications are considered to verify the performance of the new approach. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, we introduce a semi-parametric Bayesian approach based on Dirichlet process priors for the discrete calibration problem in binomial regression models. An interesting topic is the dosimetry problem related to the dose-response model. A hierarchical formulation is provided so that a Markov chain Monte Carlo approach is developed. The methodology is applied to simulated and real data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, we present the EM-algorithm for performing maximum likelihood estimation of an asymmetric linear calibration model with the assumption of skew-normally distributed error. A simulation study is conducted for evaluating the performance of the calibration estimator with interpolation and extrapolation situations. As one application in a real data set, we fitted the model studied in a dimensional measurement method used for calculating the testicular volume through a caliper and its calibration by using ultrasonography as the standard method. By applying this methodology, we do not need to transform the variables to have symmetrical errors. Another interesting aspect of the approach is that the developed transformation to make the information matrix nonsingular, when the skewness parameter is near zero, leaves the parameter of interest unchanged. Model fitting is implemented and the best choice between the usual calibration model and the model proposed in this article was evaluated by developing the Akaike information criterion, Schwarz`s Bayesian information criterion and Hannan-Quinn criterion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we present a Bayesian approach for estimation in the skew-normal calibration model, as well as the conditional posterior distributions which are useful for implementing the Gibbs sampler. Data transformation is thus avoided by using the methodology proposed. Model fitting is implemented by proposing the asymmetric deviance information criterion, ADIC, a modification of the ordinary DIC. We also report an application of the model studied by using a real data set, related to the relationship between the resistance and the elasticity of a sample of concrete beams. Copyright (C) 2008 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analytical determination of atmospheric pollutants still presents challenges due to the low-level concentrations (frequently in the mu g m(-3) range) and their variations with sampling site and time In this work a capillary membrane diffusion scrubber (CMDS) was scaled down to match with capillary electrophoresis (CE) a quick separation technique that requires nothing more than some nanoliters of sample and when combined with capacitively coupled contactless conductometric detection (C(4)D) is particularly favorable for ionic species that do not absorb in the UV-vis region like the target analytes formaldehyde formic acid acetic acid and ammonium The CMDS was coaxially assembled inside a PTFE tube and fed with acceptor phase (deionized water for species with a high Henry s constant such as formaldehyde and carboxylic acids or acidic solution for ammonia sampling with equilibrium displacement to the non-volatile ammonium ion) at a low flow rate (8 3 nLs(-1)) while the sample was aspirated through the annular gap of the concentric tubes at 25 mLs(-1) A second unit in all similar to the CMDS was operated as a capillary membrane diffusion emitter (CMDE) generating a gas flow with know concentrations of ammonia for the evaluation of the CMDS The fluids of the system were driven with inexpensive aquarium air pumps and the collected samples were stored in vials cooled by a Peltier element Complete protocols were developed for the analysis in air of NH(3) CH(3)COOH HCOOH and with a derivatization setup CH(2)O by associating the CMDS collection with the determination by CE-C(4)D The ammonia concentrations obtained by electrophoresis were checked against the reference spectrophotometric method based on Berthelot s reaction Sensitivity enhancements of this reference method were achieved by using a modified Berthelot reaction solenoid micro-pumps for liquid propulsion and a long optical path cell based on a liquid core waveguide (LCW) All techniques and methods of this work are in line with the green analytical chemistry trends (C) 2010 Elsevier B V All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The time dependence of the concentration of CO2 in an electrochemical thin layer cavity is studied with Fourier transform infrared spectroscopy (FTIR) in order to evaluate the extent to which the thin layer cavity is diffusionally decoupled from the surrounding bulk electrolyte. For the model system of CO on Pt(111) in 0.1 M HClO4, it is found that the concentration of CO2, formed by electro-oxidation of CO, equilibrates rapidly with the surrounding bulk electrolyte. This rapid equilibration indicates that there is diffusion out of the thin layer, even on the short time scales of typical infrared experiments (1-3 min). However, since the measured CO2 absorbance intensity as a function of time is reproducible to within 10%, a new time-dependent method for surface coverage calibration using solution-phase species is proposed.