3 resultados para DEPTH DOSE DISTRIBUTIONS
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
In this paper, we propose a new method of measuring the very slow paramagnetic ion diffusion coefficient using a commercial high-resolution spectrometer. If there are distinct paramagnetic ions influencing the hydrogen nuclear magnetic relaxation time differently, their diffusion coefficients can be measured separately. A cylindrical phantom filled with Fricke xylenol gel solution and irradiated with gamma rays was used to validate the method. The Fricke xylenol gel solution was prepared with 270 Bloom porcine gelatin, the phantom was irradiated with gamma rays originated from a (60)Co source and a high-resolution 200 MHz nuclear magnetic resonance (NMR) spectrometer was used to obtain the phantom (1)H profile in the presence of a linear magnetic field gradient. By observing the temporal evolution of the phantom NMR profile, an apparent ferric ion diffusion coefficient of 0.50 mu m(2)/ms due to ferric ions diffusion was obtained. In any medical process where the ionizing radiation is used, the dose planning and the dose delivery are the key elements for the patient safety and success of treatment. These points become even more important in modern conformal radio therapy techniques, such as stereotactic radiosurgery, where the delivered dose in a single session of treatment can be an order of magnitude higher than the regular doses of radiotherapy. Several methods have been proposed to obtain the three-dimensional (3-D) dose distribution. Recently, we proposed an alternative method for the 3-D radiation dose mapping, where the ionizing radiation modifies the local relative concentration of Fe(2+)/Fe(3+) in a phantom containing Fricke gel and this variation is associated to the MR image intensity. The smearing of the intensity gradient is proportional to the diffusion coefficient of the Fe(3+) and Fe(2+) in the phantom. There are several methods for measurement of the ionic diffusion using NMR, however, they are applicable when the diffusion is not very slow.
Resumo:
The quality control optimization of medical processes that use ionizing radiation in the treatment of diseases like cancer is a key element for patient safety and success of treatment. The major medical application of radiation is radiotherapy, i.e. the delivery of dose levels to well-defined target tissues of a patient with the purpose of eliminating a disease. The need of an accurate tumour-edge definition with the purpose of preserving healthy surrounding tissue demands rigorous radiation treatment planning. Dosimetric methods are used for dose distribution mapping region of interest to assure that the prescribed dose and the irradiated region are correct. The Fricke gel (FXG) is the main dosimeter that supplies visualization of the three-dimensional (3D) dose distribution. In this work the dosimetric characteristics of the modified Fricke dosimeter produced at the Radiation Metrology Centre of the Institute of Energetic and Nuclear Research (IPEN) such as gel concentration dose response dependence, xylenol orange addition influence, dose response between 5 and 50Gy and signal stability were evaluated by magnetic resonance imaging (MRI). Using the same gel solution, breast simulators (phantoms) were shaped and absorbed dose distributions were imaged by MRI at the Nuclear Resonance Laboratory of the Physics Institute of Sao Paulo University. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Dental markers have been used to unravel particularities of paleodiet, subsistence, social structure, and health. This article aims to compare oral pathology among four pre-Columbian groups with different degrees of agricultural and socio-cultural development but comparable ecological conditions who lived on the coastal desert of Peru. Three of these groups are assigned to distinct phases of the Formative Period (2500-1 BC), a time critical for our understanding of the development of agriculture and social complexity. The fourth group corresponds to the Late Intermediate Period (1000-1470 AD), when agriculture had its apogee and society was highly stratified. In this study we test whether there is an increase (1) in the frequency of carious lesions and (2) in caries depth, and (3) if there is a shift from occlusal to extra-occlusal caries locations with the development of agriculture. Therefore, we analyze the frequencies of carious lesions and antemortem tooth loss (AMTL), the caries distributions by age, sex, and type of tooth, as well as the tissues affected by, and the location of the carious lesions. Since there are no significant differences in the frequencies of carious lesions and AMTL between the groups, we reject hypothesis 1. In contrast, caries depth does increase, and caries location changes from occlusal to extra-occlusal sites with agricultural development. However, we can only corroborate hypothesis 2 and 3 when taking into consideration dental wear. Thus, we recommend that caries depth and locations should be used with evaluations of dental wear to reconstruct subsistence in ancient populations. Am J Phys Anthropol 143:75-91, 2010. (C) 2010 Wiley-Liss, Inc.