128 resultados para Cervical length measurement
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Aim: To compare cervical length (CL) at 18-21 and 22-25 weeks` gestation in twin pregnancies in prediction of spontaneous preterm delivery and to examine cervical shortening. Methods: Retrospective cohort study of CL measured at 18-21 and 22-25 weeks` gestation in twin pregnancies. Results: Receiver operating characteristics (ROC) curve revealed area of 0.64 (95% CI 0.53-0.75) and 0.80 (95% CI 0.72-0.88) for measurements at 18-21 and 22-25 weeks, respectively (P <= 0.001). Sensitivities of 33.3% and 23% and negative predicting value (NPV) of 97.3% and 86.8% for delivery at <28 and <34 weeks gestation were reached for measurements at 18-21 weeks. Sensitivities of 71.4% and 38.2% and NPV of 99.1% and 91.4% for delivery at <28 and <34 weeks` gestation were reached for measurements at 22-25 weeks. Cervical length shortening analysis showed an area under ROC curve of 0.81 (95% CI 0.73-0.89) and best cut-off was at >= 2 mm/week. Sensitivities of 80% and 60.8% and NPV of 98.9% and 90.6% for delivery at <28 and <34 weeks gestation were reached. Conclusions: In twin gestations, assessment of CL at 22-25 weeks is better than assessment at 18-21 weeks to predict preterm delivery before 34 weeks. Cervical shortening at a rate of >= 2 mm/weeks between 18 and 25 weeks gestation was a good predictor of spontaneous preterm birth in this high-risk population.
Resumo:
Aim To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. Methodology One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the actual canal length and using two electronic apex locators. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using two electronic apex locators (Root ZX II - J. Morita Corp. and Mini Apex Locator - SybronEndo) according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual root canal length and the electronic root canal length measurements revealed high correlation (ICC = 0.99), regardless of the tooth type (single-rooted and multi-rooted teeth) or the presence/absence of physiological root resorption. Conclusions Root ZX II and Mini Apex Locator proved useful and accurate for apex foramen location during root canal length measurement in primary incisors and molars.
Resumo:
Purpose of review This review summarizes the evidence of the effectiveness of progesterone on the rate of preterm birth and evaluates the most recent studies. Recent findings The incidence of preterm delivery is about 7-11% of all pregnant women and preterm birth is one of the most important causes of neonatal morbidity and mortality. Interventions to reduce such complications have been attempted for several years. Most efforts so far have been tertiary interventions, such as treatment with antenatal corticosteroids, tocolytic agents, and antibiotics. Some of these measures have reduced perinatal morbidity and mortality, but the incidence of preterm birth is increasing. Recently, researches have suggested prophylactic progesterone could reduce the preterm birth rate in a select group presenting previous preterm birth and a short cervical length by transvaginal scan at mid-trimester pregnancy. Summary This review intends to define the current indication for administration of progesterone for pregnant women. On the basis of current knowledge, progesterone should be offered to women with a documented history of a previous spontaneous birth at less than 37 weeks and for those found to have a short cervical length of 15 mm or less. Studies are needed to evaluate progesterone efficacy on other risk factors.
Resumo:
The purpose of this study was to evaluate ex vivo the accuracy an electronic apex locator during root canal length determination in primary molars. Methods: One calibrated examiner determined the root canal length in 15 primary molars (total=34 root canals) with different stages of root resorption. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using an electronic apex locator (Digital Signal Processing). Data were analyzed statistically using the intraclass correlation (ICC) test. Results: Comparing the actual and electronic root canal length measurements in the primary teeth showed a high correlation (ICC=0.95) Conclusions: The Digital Signal Processing apex locator is useful and accurate for apex foramen location during root canal length measurement in primary molars. (Pediatr Dent 200937:320-2) Received April 75, 2008 vertical bar Lost Revision August 21, 2008 vertical bar Revision Accepted August 22, 2008
Resumo:
P>Aim To evaluate ex vivo the accuracy of the iPex multi-frequency electronic apex locator (NSK Ltd, Tokyo, Japan) for working length determination in primary molar teeth. Methodology One calibrated examiner determined the working length in 20 primary molar teeth (total of 33 root canals). Working length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the most coronal limit of root resorption, and electronically using the electronic apex locator iPex, according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual and the electronic measurements revealed high correlation (ICC = 0.99) between the methods, regardless of the presence or absence of physiological root resorption. Conclusions In this laboratory study, the iPex accurately identified the apical foramen or the apical opening location for working length measurement in primary molar teeth.
Resumo:
This study evaluated the sealing ability of different lengths of remaining root canal filling and post space preparation against coronal leakage of Enterococcus faecalis. Forty-one roots of maxillary incisors were biomechanically prepared, maintaining standardized canal diameter at the middle and coronal thirds. The roots were autoclaved and all subsequent steps were undertaken in a laminar flow chamber. The canals of 33 roots were obturated with AH Plus sealer and gutta-percha. The root canal fillings were reduced to 3 predetermined lengths (n=11): G1=6 mm, G2=4 mm and G3=2 mm. The remaining roots served as positive and negative controls. Bacterial leakage test apparatuses were fabricated with the roots attached to Eppendorf tubes keeping 2 mm of apex submerged in BHI in glass flasks. The specimens received an E. faecalis inoculum of 1 x 107 cfu/mL every 3 days and were observed for bacterial leakage daily during 60 days. Data were submitted to ANOVA, Tukey's test and Fisher's test. At 60 days, G1 (6 mm) and G2 (4 mm) presented statistically similar results (p>0.05) (54.4% of specimens with bacterial leakage) and both groups differed significantly (p<0.01) from G3 (2 mm), which presented 100% of specimens with E. faecalis leakage. It may be concluded that the shortest endodontic obturation remnant leaked considerably more than the other lengths, although none of the tested conditions avoids coronal leakage of E. faecalis.
Resumo:
This study investigated the influence of cervical preflaring with different rotary instruments on determination of the initial apical file (IAF) in mesiobuccal roots of mandibular molars. Fifty human mandibular molars whose mesial roots presented two clearly separated apical foramens (mesiobuccal and mesiolingual) were used. After standard access opening and removal of pulp tissue, the working length (WL) was determined at 1 mm short of the root apex. Five groups (n=10) were formed at random, according to the type of instrument used for cervical preflaring. In group 1, the size of the IAF was determined without preflaring of the cervical and middle root canal thirds. In groups 2 to 5, preflaring was performed with Gates-Glidden drills, ProTaper instruments, EndoFlare instruments and LA Axxes burs, respectively. Canals were sized manually with K-files, starting with size 08 K-files, inserted passively up to the WL. File sizes were increased until a binding sensation was felt at the WL and the size of the file was recorded. The instrument corresponding to the IAF was fixed into the canal at the WL with methylcyanoacrylate. The teeth were then sectioned transversally 1 mm short of the apex, with the IAF in position. Cross-sections of the WL region were examined under scanning electron microscopy and the discrepancies between canal diameter and the diameter of IAF were calculated using the tool "rule" (FEG) of the microscope's proprietary software. The measurements (µm) were analyzed statistically by Kruskal-Wallis and Dunn's tests at 5% significance level. There were statistically significant differences among the groups (p<0.05). The non-flared group had the greatest discrepancy (125.30 ± 51.54) and differed significantly from all flared groups (p<0.05). Cervical preflaring with LA Axxess burs produced the least discrepancies (55.10 ± 48.31), followed by EndoFlare instruments (68.20 ± 42.44), Gattes Glidden drills (68.90 ± 42.46) and ProTaper files (77.40 ± 73.19). However, no significant differences (p>0.05) were found among the rotary instruments. In conclusion, cervical preflaring improved IAF fitting to the canals at the WL in mesiobuccal roots of maxillary first molars. The rotary instruments evaluated in this study did not differ from each other regarding the discrepancies produced between the IAF size and canal diameter at the WL.
Resumo:
OBJETIVO: avaliar a morfometria da pars da segunda vértebra cervical, verificar as variações existentes e predizer sua segurança para a colocação de parafusos por meio de uma abordagem cervical posterior. MÉTODOS: 58 vértebras foram obtidas para estudo anatômico (116 pars de C2) e foram medidas a altura e largura da pars, além do comprimento eixo-pedículo, largura e comprimento do pedículo, angulação sagital e medial. Todas as medidas foram separadas quanto aos seus lados direito e esquerdo; foi realizado o cálculo da média, variação, desvio padrão e a médica foi comparada com os estudos prévios. RESULTADOS: a largura média da pars de C2 foi de 9,5 mm; a altura, 9,5 mm; não houve diferença significativa entre os lados esquerdo e direito. O comprimento médio do pedículo foi de 10,5 mm; a medida média encontrada para o comprimento eixo-pedículo foi de 24,9 mm; a largura do pedículo foi de 2,8 mm. A angulação sagital encontrada foi de 19,6º e a horizontal foi de 28,5º. CONCLUSÕES: este estudo demonstra a viabilidade para a colocação de parafuso na pars de C2 em uma população caucasiana, destacando-se, porém, a grande variabilidade anatômica encontrada nas referidas medidas.
Resumo:
Void fraction sensors are important instruments not only for monitoring two-phase flow, but for furnishing an important parameter for obtaining flow map pattern and two-phase flow heat transfer coefficient as well. This work presents the experimental results obtained with the analysis of two axially spaced multiple-electrode impedance sensors tested in an upward air-water two-phase flow in a vertical tube for void fraction measurements. An electronic circuit was developed for signal generation and post-treatment of each sensor signal. By phase shifting the electrodes supplying the signal, it was possible to establish a rotating electric field sweeping across the test section. The fundamental principle of using a multiple-electrode configuration is based on reducing signal sensitivity to the non-uniform cross-section void fraction distribution problem. Static calibration curves were obtained for both sensors, and dynamic signal analyses for bubbly, slug, and turbulent churn flows were carried out. Flow parameters such as Taylor bubble velocity and length were obtained by using cross-correlation techniques. As an application of the void fraction tested, vertical flow pattern identification could be established by using the probability density function technique for void fractions ranging from 0% to nearly 70%.
Resumo:
The inflammasome is an inducible cytoplasmic structure that is responsible for production and release of biologically active interleukin-1 (IL-1). A polymorphism in the inflammasome component NALP3 has been associated with decreased IL-1 levels and increased occurrence of vaginal Candida infection. We hypothesized that this polymorphism-induced variation would influence susceptibility to infertility. DNA was obtained from 243 women who were undergoing in vitro fertilization (IVF) and tested for a length polymorphism in intron 2 of the gene coding for NALP3 (gene symbol CIAS1). At the conclusion of testing the findings were analyzed in relation to clinical parameters and IVF outcome. The frequency of the 12 unit repeat allele, associated with maximal inflammasome activity, was 62.3% in cases of female infertility vs. 75.6% in cases where only the male partner had a detectable fertility problem (p = 0.0095). Conversely, the frequency of the 7 unit repeat allele was 28.9% in those with a female fertility problem, 17.0% in women with infertile males and 18.4% in idiopathic infertility (p = 0.0124). Among the women who were cervical culture-positive for mycoplasma the frequency of the 7 unit repeat was 53.7% as opposed to 19.5% in those negative for this infection (p < 0.0001). We conclude that the CIAS1 7 unit repeat polymorphism increases the likelihood of mycoplasma infection-associated female infertility. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Aims: To evaluate the role of hormonal contraceptives as a risk factor of high-risk human papillomavirus (HR-HPV), cervical intraepithelial lesions (CIN) and cervical cancer in our multi-center population-based LAMS (Latin American Screening) study. Methods: A cohort study with >12,000 women from Brazil and Argentina using logistic regression to analyze the covariates of hormonal contraception (HOC - oral, injections, patches, implants, vaginal ring and progesterone intrauterine system) use followed by multivariate modeling for predictors of HR-HPV and CIN2+. Results: HR-HPV infection was a consistent risk factor of high-grade CIN in all three groups of women. The length of HOC use was not significantly related to high-grade squamous intraepithelial lesions (HSIL)+ Pap (p = 0.069), LSIL+ Pap (p = 0.781) or ASCUS+ (p = 0.231). The same was true with the length of HOC use and histology CIN3+ (p = 0.115) and CIN2+ (p = 0.515). Frequently, HOC users have previously shown more HPV-related lesions, as well as lower HPV prevalence if they were current smokers. But HOC use and time of usage were not independent risk factors of either HR-HPV infection or high-grade CIN using multiple logistic regressions. Conclusions: No evidence was found for an association between the use of HOC with an increased risk for HR-HPV infection or high-grade CIN in this cohort. Copyright (C) 2010 S. Karger AG, Basel
Resumo:
The aim of this study was to compare the crown-rump length (CRL) and the fetal head and trunk (HT) volume between singletons and twins conceived after in vitro fertilization. Thirty pregnant patients submitted to embryo transfer were enrolled in this research. Ten conceived twins (20 dichorionic fetuses) while other 20 conceived singletons. The gestational age was calculated by adding 14 d to the number of days between the oocyte retrieval and the scheduled ultrasound. Three-dimensional ultrasound scans were performed weekly from 73 d (10 wk and 3 d) to 101 d (14 wk and 3 d) of gestational age. HT volume was assessed by VOCAL using 15 degrees step rotation on the manual mode. The measurement of CRL was performed by using the longitudinal plane of the fetus in the multiplanar view. The CRL and HT volume weekly relative increase were evaluated to compare the growth between singletons and twins. No significant difference was identified, in any analyzed week, when comparing the mean of CRL and HT volume between singletons and twins. Additionally, no significant difference between singletons and twins was noticed when comparing the weekly relative increase, both for CRL and HT volume. However, the weekly relative increase was significantly higher for HT volume than for CRL in every week studied for both singletons and twins. The total relative increase observed between 73 and 101 d was much higher for HT volume than for CRL: 679 +/- 39% versus 138 +/- 18% in singletons and 689 +/- 58% versus 139 +/- 21% in twins (HT volume and CRL, respectively), suggesting that HT volume could more accurately determine the gestational age.
Resumo:
Objectives. The objectives of this study were to assess the accuracy of working length determination using 3 electronic apex locators and direct digital radiography and to compare the results with those obtained using the visual method (control measurement). Study design. Twenty extracted human maxillary premolars were selected: 17 two-rooted and 3 single-rooted (total of 37 canals). Working length was measured using electronic apex locators Elements Diagnostic, Root ZX, and Just II. Subsequently, teeth were positioned in the alveolar bone of a dry skull and submitted to direct digital radiography. A variation of +/- 1 mm was considered as acceptable. Results were analyzed using the Wilcoxon and the chi(2) tests. Results. Results presented an accuracy of 94.6% for Elements Diagnostic, 91.9% for Root ZX, 73.0% for Just II, and 64.9% for direct digital radiography when considering the margin of +/- 1 mm in relation to the control measurement. Comparisons with the actual control measurements resulted in accuracy results of 13.51%, 13.51%, 10.10%, and 2.70%, respectively. Conclusions. Root ZX and Elements Diagnostic are more accurate in determining working length when compared with Just II and Schick direct digital radiography. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111:e44-e49)
Resumo:
Background. Researchers have proposed the restoration of abfraction lesions, but limited information is available about the effects of occlusal loading on the margins of such restorations. Because abfraction is a well-recognized problem, the authors conducted a study to assess the effects of occlusal loading on the margins of cervical restorations. Methods. The authors prepared 40 wedge-shaped cavities in extracted premolars and restored them with a resin-based composite. They subjected specimens to occlusal loading (150 newtons, 101 cycles) on the buccal cusp, on the central fossa or on the lingual cusp, and they stored 1 the control group, specimens in deionized water. The authors used fluorescein to delimit marginal defects and evaluated the defects by using laser scanning confocal microscopy. Results. Results of chi(2) and Kruskal-Wallis tests (P < .05) showed that specimens subjected to occlusal loading had a higher percentage of marginal gaps (53.3 percent) than did the control specimens (10.0 percent). There were no differences between groups in marginal defect formation or in defect location, length or width. Conclusions. Occlusal loading led to a significant increase in gap formation at the margins of cervical resin-based composite restorations. Clinical Implications. The clinician cannot underestimate the effects of occlusal loading When restoring teeth with cervical wedge-shaped lesions. If occlusal loading is the main factor contributing to lesion formation, the clinician should identify and treat it before placing the restoration or otherwise run the risk that the restorative treatment will fail because of marginal gap formation.
Resumo:
The present study aimed to evaluate the cephalometric changes in Class II patients treated exclusively with cervical headgear (CHG) in the maxillary arch and fixed appliances in the mandibular arch as compared with a control group. The sample comprised 82 lateral cephalograms obtained pre- (T1) and post- (T2) treatment/observation of 41 subjects, divided into two groups: group 1-25 Class II division 1 patients (20 females and five males), with a mean pre-treatment age of 10.4 years, treated for a mean period of 2.5 years and group 2-16 Class II untreated subjects (12 females and four males), with a mean initial age of 9.9 years, followed for a mean period of 2.2 years. Treatment changes between the groups were compared by means of t-tests. The results showed restriction of maxillary forward displacement and also a restriction in maxillary length growth, improvement in the maxillomandibular relationship, restriction of mandibular incisor vertical development, reduction in overjet and overbite, and improvement in molar relationship. It was concluded that this treatment protocol corrected the Class II malocclusion characteristics primarily through maxillary forward growth restriction.