54 resultados para COSTEO ABC
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
This report focuses on the effects of cholesterol on the expression and function of the ATP-binding cassette (ABCB1, ABCG2 and ABCC2) and solute-linked carrier (SLCO1B1 and SLCO2B1) drug transporters with a particular focus on the potential impact of cholesterol on lipid-lowering drug disposition. Statins are the most active agents in the treatment of hypercholesterolemia. However, considerable interindividual variation exists in the response to statin therapy. Therefore, it would be huge progress if factors were identified that reliably differentiate between responders and nonresponders. Many studies have suggested that plasma lipid concentrations can affect drug disposition of compounds, such as ciclosporin and amphotericin B. Both compounds are able to affect the expression and function of ABC transporters. Although still speculative, these effects might be owing to the regulation of drug transporters by plasma cholesterol levels. Studies with normo- and hyper-cholesterolemic individuals, before and after atorvastatin treatment, have demonstrated that plasma cholesterol levels are correlated with drug transporter expression, as well as being related to atorvastatin`s cholesterol-lowering effect. The mechanism influencing the correlation between cholesterol levels and the expression and function of drug transporters remains unclear. Some studies provide strong evidence that nuclear receptors, such as the pregnane X receptor and the constitutive androstane receptor, mediate this effect. In the near future, pharmacogenomic studies with individuals in a pathological state should be performed in order to identify whether high plasma cholesterol levels might be a factor contributing to interindividual oral drug bioavailability.
Resumo:
Resistance to drug is a major cause of treatment failure in pediatric brain cancer. The multidrug resistance (MDR) phenotype can be mediated by the superfamily of adenosine triphosphate-binding cassette (ABC) transporters. The dynamics of expression of the MDR genes after exposure to chemotherapy, especially the comparison between pediatric brain tumors of different histology, is poorly described. To compare the expression profiles of the multidrug resistance genes ABCB1, ABCC1, and ABCG2 in different neuroepithelial pediatric brain tumor cell lines prior and following short-term culture with vinblastine. Immortalized lineages from pilocytic astrocytoma (R286), anaplasic astrocytoma (UW467), glioblastoma (SF188), and medulloblastoma (UW3) were exposed to vinblastine sulphate at different schedules (10 and 60 nM for 24 and 72 h). Relative amounts of mRNA expression were analyzed by real-time quantitative polymerase chain reaction. Protein expression was assessed by immunohistochemistry for ABCB1, ABCC1, and ABCG2. mRNA expression of ABCB1 increased together with augmenting concentration and time of exposure to vinblastine for R286, UW467, and UW3 cell lines. Interestingly, ABCB1 levels of expression diminished in SF188. Following chemotherapy, mRNA expression of ABCC1 decreased in all cell lines other than glioblastoma. ABCG2 expression was influenced by vinblastine only for UW3. The mRNA levels showed consistent association to protein expression in the selected sets of cell lines analyzed. The pediatric glioblastoma cell line SF188 shows different pattern of expression of multidrug resistance genes when exposed to vinblastine. These preliminary findings may be useful in determining novel strategies of treatment for neuroepithelial pediatric brain tumors.
Resumo:
Reconhecer com precisão indivíduos com maior risco imediato de morte súbita cardíaca (MSC) ainda é uma questão em aberto. A natureza fortuita dos eventos cardiovasculares agudos não parece se adequar ao conhecido modelo de indução de taquicardia/fibrilação ventricular por um gatilho em sincronia a um substrato arritmogênico estático. Quanto ao mecanismo da MSC, uma instabilidade elétrica dinâmica explicaria melhor a raridade da associação simultânea de um gatilho certo a um substrato cardíaco apropriado. Diversos estudos tentaram medir essa instabilidade elétrica cardíaca (ou um equivalente válido) em uma sequência de batimentos cardíacos no ECG. Dentre os mecanismos possíveis podemos citar o prolongamento do QT, dispersão do QT, potenciais tardios, alternância de onda T ou T-wave alternans (TWA), e turbulência da frequência cardíaca. Este artigo se atém em particular ao papel da TWA no panorama atual da estratificação de risco cardíaco. Os achados sobre TWA ainda são heterogêneos, variando de um desempenho prognóstico muito bom até um quase nulo, dependendo da população clínica observada e protocolo clínico usado. Para preencher as atuais lacunas no conhecimento sobre TWA, profissionais médicos e pesquisadores devem explorar melhor as características técnicas das diversas tecnologias disponíveis para a avaliação de TWA e atentar ao fato de que os valores de TWA respondem a diversos outros fatores, além de medicamentos. Informações sobre mecanismos celulares e subcelulares da TWA estão fora do escopo deste artigo, mas são referenciados alguns dos principais trabalhos sobre este tópico, com o intuito de auxiliar no entendimento dos conceitos e fatos cobertos neste artigo.
Resumo:
The purpose of this study was to evaluate the impact and fracture resistance of acrylic resins: a heat-polymerized resin, a high-impact resin and an experimental polymethyl methacrylate with elastomer in different proportions (10, 20, 40 and 60%). 120 specimens were fabricated and submitted to conventional heat-polymerization. For impact test, a Charpy-type impact tester was used. Fracture resistance was assessed with a 3-point bending test by using a mechanical testing machine. Ten specimens were used for each test. Fracture (MPa) and impact resistance values (J.m-1) were submitted to ANOVA - Bonferroni's test - 5% significance level. Materials with higher amount of elastomer had statistically significant differences regarding to impact resistance (p < 0.05). Fracture resistance was superior (p < 0.01) for high-resistance acrylic resin. The increase in elastomer concentration added to polymethyl methacrylate raised the impact resistance and decreased the fracture resistance. Processing the material by injection decreased its resistance to impact and fracture.
Resumo:
This study evaluated the effect of surface sealant on the translucency of composite resin immersed in different solutions. The study involved the following materials: Charisma, Fortify and coffee, Coca-Cola®, tea and artificial saliva as solutions. Sixty-four specimens (n = 8) were manufactured and immersed in artificial saliva at 37 ± 1 °C. Samples were immersed in the solutions for three times a day and re-immersed in artificial saliva until the translucency readings. The measurements were carried out at nine times: T1 - 24 hours after specimen preparation, T2 - 24 hours after immersion in the solutions, T3 - 48 hours and T4 to T9 - 7, 14, 21, 30, 60 and 90 days, respectively, after immersion. The translucency values were measured using a JOUAN device. The results were subjected to ANOVA and Tukey's test at 5%. The surface sealant was not able to protect the composite resin against staining, the coffee showed the strongest staining action, followed by tea and regarding immersion time, a significant alteration was noted in the translucency of composite resin after 21 days.
Resumo:
The aim of the present study was to evaluate the influence of different photopolymerization (halogen, halogen soft-start and LED) systems on shear bond strength (SBS) and marginal microleakage of composite resin restorations. Forty Class V cavities (enamel and dentin margins) were prepared for microleakage assessment, and 160 enamel and dentin fragments were prepared for the SBS test, and divided into 4 groups. Kruskal-Wallis and Wilcoxon tests showed statistically significant difference in microleakage between the margins (p < 0.01) with incisal margins presenting the lowest values. Among the groups, it was observed that, only at the cervical margin, halogen soft-start photo polymerization presented statistically significant higher microleakage values. For SBS test, ANOVA showed no statistical difference (p > 0.05) neither between substrates nor among groups. It was concluded that Soft-Start technique with high intensity end-light influenced negatively the cervical marginal sealing, but the light-curing systems did not influence adhesion.
Resumo:
FUNDAMENTO: A doença periodontal representa risco à gestante portadora de valvopatia reumática, seja para contrair endocardite infecciosa, seja por propiciar complicações obstétricas. OBJETIVO: Estudar a frequência da doença periodontal em portadoras de valvopatia reumática durante a gravidez. MÉTODOS: Foram estudadas 140 gestantes, comparáveis quanto a idade e o nível socioeconômico, divididas em: 70 portadoras de doença valvar reumática e 70 mulheres saudáveis. Todas se submeteram a: 1) avaliação clínica odontológica que incluiu a análise dos seguintes parâmetros: 1.1) profundidade à sondagem, 1.2) distância da linha esmalte-cemento à margem gengival, 1.3) nível clínico de inserção, 1.4) índice de sangramento, 1.5) índice de placa bacteriana, e, 1.6) comprometimento de furca; e, 2) exame microbiológico nas amostras de saliva e do cone que considerou o controle positivo para as cepas das bactérias Porphyromonas gingivalis, Tannerella forsithia e Aggregobacter actinomycetemcomitans. RESULTADOS: A lesão valvar mitral foi prevalente (65 casos = 92,8%) dentre as gestantes cardiopatas. A comparação entre os grupos mostrou não haver diferenças entre idade e a paridade, e embora tenham sido verificadas diferenças entre as medidas da distância da linha esmalte-cemento à margem gengival (p = 0,01) e o índice de placa (p=0,04), a frequência da doença periodontal identificada em 20 (14,3%) gestantes, não foi diferente entre os grupos (p = 0,147). O exame microbiológico mostrou uma proporção maior da bactéria P. gingivalis na saliva de gestantes saudáveis (p = 0,004). CONCLUSÃO: O estudo clínico e microbiológico periodontal durante a gravidez demonstrou igual frequência da doença periodontal em portadoras de valvopatia reumática quando comparada às mulheres saudáveis.
Resumo:
With the increase in life expectancy, biomaterials have become an increasingly important focus of research because they are used to replace parts and functions of the human body, thus contributing to improved quality of life. In the development of new biomaterials, the Ti-15Mo alloy is particularly significant. In this study, the Ti-15Mo alloy was produced using an arc-melting furnace and then characterized by density, X-ray diffraction, optical microscopy, hardness and dynamic elasticity modulus measurements, and cytotoxicity tests. The microstructure was obtained with β predominance. Microhardness, elasticity modulus, and cytotoxicity testing results showed that this material has great potential for use as biomaterial, mainly in orthopedic applications.
Resumo:
This study investigated the influence of bioactive materials on the dentin surface whitened. MATERIAL AND METHODS: Three bovine teeth were shaped into three dentin wafers. Each wafer was then sectioned, into six dentin slices. One slice from each tooth was distributed into one of 6 groups: 1.CG = control group (distilled water); 2.WT = whitening treatment; 3.WT + MI Paste Plus, applied once a day; 4.WT + Relief ACP30, applied once a day for 30 mintes; 5.WT + Relief ACP60, applied once a day for 60 minutes; 6.WT + Biosilicate®, applied once a week. All groups were treated over 14 days. RESULTS: CG presented all dentinal tubules occluded by smear layer; WT group was observed all dentinal tubules opened. In the groups 3, 4 and 6, tubules were occluded. Group 5, dentinal tubules were completely occluded by mineral deposits. CONCLUSION: The use of bioactive materials immediately after whitening treatment can reduce or even avoid the demineralization effect of whitening and avoid exposing dentinal tubules.
Resumo:
This study evaluated the effect of specimens' design and manufacturing process on microtensile bond strength, internal stress distributions (Finite Element Analysis - FEA) and specimens' integrity by means of Scanning Electron Microscopy (SEM) and Laser Scanning Confocal Microscopy (LCM). Excite was applied to flat enamel surface and a resin composite build-ups were made incrementally with 1-mm increments of Tetric Ceram. Teeth were cut using a diamond disc or a diamond wire, obtaining 0.8 mm² stick-shaped specimens, or were shaped with a Micro Specimen Former, obtaining dumbbell-shaped specimens (n = 10). Samples were randomly selected for SEM and LCM analysis. Remaining samples underwent microtensile test, and results were analyzed with ANOVA and Tukey test. FEA dumbbell-shaped model resulted in a more homogeneous stress distribution. Nonetheless, they failed under lower bond strengths (21.83 ± 5.44 MPa)c than stick-shaped specimens (sectioned with wire: 42.93 ± 4.77 MPaª; sectioned with disc: 36.62 ± 3.63 MPa b), due to geometric irregularities related to manufacturing process, as noted in microscopic analyzes. It could be concluded that stick-shaped, nontrimmed specimens, sectioned with diamond wire, are preferred for enamel specimens as they can be prepared in a less destructive, easier, and more precise way.
Resumo:
The objective of this work was to evaluate biaxial-flexural-strength (σf), Vickers hardness (HV), fracture toughness (K Ic), Young's modulus (E), Poisson's ratio (ν) and porosity (P) of two commercial glass-ceramics, Empress (E1) and Empress 2 (E2), as a function of the hot-pressing temperature. Ten disks were hot-pressed at 1065, 1070, 1075 and 1080 °C for E1; and at 910, 915, 920 and 925 °C for E2. The porosity was measured by an image analyzer software and s f was determined using the piston-on-three-balls method. K Ic and HV were determined by an indentation method. Elastic constants were determined by the pulse-echo method. For E1 samples treated at different temperatures, there were no statistical differences among the values of all evaluated properties. For E2 samples treated at different temperatures, there were no statistical differences among the values of σf, E, and ν, however HV and K Ic were significantly higher for 910 and 915 °C, respectively. Regarding P, the mean value obtained for E2 for 925 °C was significantly higher compared to other temperatures.
Resumo:
The present work describes non-conventional sisal (Agave sisalana) chemical (organosolv) pulp from residues of cordage as reinforcement to cement based materials. Sisal organosolv pulp was produced in a 1:1 ethanol/water mixture and post chemically and physically characterized in order to compare its properties with sisal kraft pulp. Cement based composites reinforced with organosolv or kraft pulps and combined with polypropylene (PP) fibres were produced by the slurry de-watering and pressing method as a crude simulation of the Hatschek process. Composites were evaluated at 28 days of age, after exposition to accelerated carbonation and after 100 soak/dry cycles. Composites containing organosolv pulp presented lower mechanical strength, water absorption and apparent porosity than composites reinforced with kraft pulp. The best mechanical performance after ageing was also achieved by samples reinforced with kraft pulp. The addition of PP fibres favoured the maintenance of toughness after ageing. Accelerated carbonation promoted the densification of the composites reinforced with sisal organosolv + PP fibres.
Resumo:
FUNDAMENTO: Os efeitos da anestesia local em odontologia com lidocaína e epinefrina, sobre parâmetros cardiovasculares de gestantes portadoras de valvopatias e seus conceptos, não estão esclarecidos. OBJETIVO: Avaliar e analisar parâmetros da cardiotocografia, de pressão arterial e eletrocardiográficos da gestante portadora de doença valvar reumática, quando submetida à anestesia local com 1,8 ml de lidocaína 2% sem vasoconstritor e com epinefrina 1:100.000, durante procedimento odontológico restaurador. MÉTODOS: Realizamos monitorização ambulatorial da pressão arterial, eletrocardiografia ambulatorial materna e cardiotocografia de 31 portadoras de cardiopatia reumática, entre a 28ª e 37ª semana de gestação, divididas em dois grupos conforme presença ou não do vasoconstritor RESULTADOS: Demonstrou-se redução significativa dos valores de frequência cardíaca materna nos dois grupos, durante o procedimento, quando comparado aos demais períodos (p < 0,001). Houve ocorrência de arritmia cardíaca em 9 (29,0%) pacientes, das quais 7 (41,8%) pertencentes ao grupo de 17 gestantes que recebeu anestesia com adrenalina. A pressão arterial materna não apresentou diferença quando comparamos períodos ou grupos (p > 0,05). O mesmo ocorreu (p > 0,05) com número de contrações uterinas, nível e variabilidade da linha de base e número de acelerações da frequência cardíaca fetal. CONCLUSÃO: O uso de 1,8 ml de lidocaína 2% associado à adrenalina mostrou-se seguro e eficaz em procedimento odontológico restaurador durante a gestação de mulheres com cardiopatia valvar reumática.
Resumo:
FUNDAMENTO: A ressuscitação de parada cardíaca pode apresentar disfunção miocárdica determinada pelo tempo da isquemia, e a inibição da enzima conversora de angiotensina (ECA) pode reduzir a disfunção cardíaca durante a reperfusão. OBJETIVO: Investigar os efeitos da angiotensina-I e diferentes períodos de isquemia na recuperação funcional em corações de ratos isolados. MÉTODOS: Os corações isolados de ratos Wistar (n = 45; 250-300 g) foram submetidos a diferentes períodos de isquemia global (20, 25 ou 30 min) e reperfundidos (30 min) com o tampão Krebs-Henseleit, ou com a adição de 400 nmol/L de angiotensina-I, ou com 400 nmol/L de angiotensina-I + 100 µmol/L de captopril durante o período de reperfusão. RESULTADOS: A derivada positiva máxima de pressão (+dP/dt max) e o produto frequência-pressão foram reduzidos nos corações expostos à isquemia de 25 min (~ 73%) e à isquemia de 30 min (~ 80%) vs. isquemia de 20 min. A pressão diastólica final do ventrículo esquerdo (PDFVE) e a pressão de perfusão (PP) foram aumentadas nos corações expostos à isquemia de 25 min (5,5 e 1,08 vezes, respectivamente) e à isquemia de 30 min (6 e 1,10 vezes, respectivamente) vs. isquemia de 20 min. A angiotensina-I ocasionou uma diminuição no +dP/dt max e no produto frequência-pressão (~ 85-94%) em todos os períodos de isquemia e um aumento na PDFVE e na PP (6,9 e 1,25 vezes, respectivamente) apenas na isquemia de 20 min. O captopril foi capaz de reverter parcial ou completamente os efeitos da angiotensina-I na recuperação funcional nas isquemias de 20 e 25 min CONCLUSÃO: Os dados sugerem que a angiotensina-II participa direta ou indiretamente no dano pós-isquêmico e que a capacidade de um inibidor da ECA atenuar esse dano depende do tempo de isquemia.
Resumo:
FUNDAMENTO: A oxidação da lipoproteína de baixa densidade (LDL-ox) induz à formação de epítopos imunogênicos na molécula. A presença de autoanticorpos contra a LDL-ox tem sido demonstrada no soro de pacientes com doença arterial coronariana (DAC). Contudo, o papel desses autoanticorpos na fisiopatologia das síndromes coronarianas agudas (SCA) e o seu significado clínico permanecem indefinidos. OBJETIVO: Avaliar a associação entre autoanticorpos contra a LDL-ox e SCA. MÉTODOS: Os títulos de imunoglobulina G autoanticorpos contra a LDL-ox por cobre (antiLDL-ox) e contra o peptídeo sintético D derivado da apolipoproteína B (antipeptD) foram determinados por ensaio imunoenzimático (ELISA) em 90 pacientes, nas primeiras 12h de SCA (casos) e em 90 pacientes com DAC crônica (controles). RESULTADOS: Os resultados mostraram que os títulos de antiLDL-ox foram significativamente mais elevados (p = 0,017) nos casos (0,40 ± 0,22), do que nos controles (0,33 ± 0,23). Por outro lado, os títulos de antipeptD foram significativamente menores (p < 0,01) nos casos (0,28 ± 0,23) do que nos controles (0,45 ± 0,30). A diferença dos títulos de ambos anticorpos entre os dois grupos estudados foi independente de idade, sexo, hipertensão arterial, diabete melito, dislipidemia, índice de massa corporal, tabagismo, perfil lipídico, uso de estatinas e história familiar de DAC. CONCLUSÃO: Os resultados mostraram que os títulos de antiLDL-ox foram significativamente mais elevados nos pacientes com síndrome coronariana aguda quando comparados aos pacientes com doença arterial coronariana e podem estar associados à instabilidade da placa aterosclerótica.