4 resultados para Best response

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hydroxymethylnitrofurazone presents in vitro activity against Trypanosoma cruzi. The optimization of the synthesis of this compound was performed through a 3(2) factorial statistical design. Quadratic model produced the best response surface predicting a maximum yield (82%) close to the center design point with a seven hours reaction and a 1:1.5 (NF:K(2)CO(3)) ratio.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A biomimetic sensor is proposed as a promising new analytical method for determination of captopril in different classes of samples. The sensor was prepared by modifying a carbon paste electrode with iron (II) phthalocyanine bis(pyridine) [FePe(dipy)] complex. Amperometric measurements in a batch analytical mode were first carried out in order to optimize the sensor response. An applied potential lower than 0.2 V vs Ag vertical bar AgCl in 0.1 mol L(-1) of TRIS buffer at pH 8.0 provided the best response, with a linear range of 2.5 x 10(-5) to 1.7 x 10(-4) mol L(-1). A detailed investigation of the selectivity of the sensor, employing seventeen other drugs, was also performed. Recovery studies were carried out using biological and environment samples in order to evaluate the sensor`s potential for use with these sample classes. Finally, the performance of the biomimetic sensor was optimized in a flow injection (FIA) system using a wall jet electrochemical cell. Under optimized flow conditions, a broad linear response range, from 5.0 x 10(-4) to 2.5 x 10(-2) mol L(-1), was obtained for captopril, with a sensitivity of 210 +/- 1 mu A L mol(-1).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To find the most reliable screening method for Trypanosoma cruzi infection in blood banks. Epidemiological data, lymphoproliferation assay, parasitological, conventional serological tests: immunofluorescence, haemagglutination, ELISA with epimastigote and trypomastigote antigens and reference serological tests: trypomastigote excreted-secreted antigens (TESA) blot and chemiluminescent ELISA assay with mucine from trypomastigote forms were applied to individuals with inconclusive serology, non-chagasic individuals and chronic chagasic patients. TESA blot had the best performance when used as a single test in all the groups. In the inconclusive group 20.5% of individuals were positive for TESA blot, 23.3% for either lymphoproliferation or TESA blot, and 17.8% for lymphoproliferation only. Positive lymphoproliferation without detectable antibodies was observed in 5.47% of all inconclusive serology cases. Analysis of six parameters (three serological assays, at least one parasitological test, one lymphoproliferation assay and epidemiological data) in the inconclusive group showed that diagnosis of Chagas` disease was probable in 15 patients who were positive by two or more serological tests or for whom three of those six parameters were positive. TESA blot is a good confirmatory test for Chagas` disease in the inconclusive group. Although lymphoproliferation suggests the diagnosis of Chagas` disease in the absence of antibodies when associated with a high epidemiological risk of acquiring Chagas` disease, the data from this study and the characteristics of the lymphoproliferation assay (which is both laborious and time-consuming) do not support its use as a confirmatory test in blood-bank screening. However, our findings underscore the need to develop alternative methods that are not based on antibody detection to improve the diagnosis when serological tests are inconclusive.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Some dosimetric properties of watch glasses were studied applying the thermoluminescence technique. The watch glass samples were powdered, and the selected grains were mixed with Teflon (TM). The mixture was pressed and sintered to produce pellets of watch glass-Teflon (TM) composites. The glow curves of the pellets show two peaks at 130 and 195 degrees C. Reproducibility of TL response was estimated to have a maximum coefficient of variation of 4.0%. The dose-response curve is sublinear between 0.5 and 20.0kGy. The calibration curve is linear between 1.0Gy and 1.0kGy. The minimum detection limits were also determined. The gamma radiation dose response and the thermal stability of the materials were studied with the purpose to establish the best conditions of watch glasses for use in gamma radiation dosimetry. (C) 2007 Elsevier Ltd. All rights reserved.