166 resultados para optical frequency
Resumo:
Recent advances in the control of molecular engineering architectures have allowed unprecedented ability of molecular recognition in biosensing, with a promising impact for clinical diagnosis and environment control. The availability of large amounts of data from electrical, optical, or electrochemical measurements requires, however, sophisticated data treatment in order to optimize sensing performance. In this study, we show how an information visualization system based on projections, referred to as Projection Explorer (PEx), can be used to achieve high performance for biosensors made with nanostructured films containing immobilized antigens. As a proof of concept, various visualizations were obtained with impedance spectroscopy data from an array of sensors whose electrical response could be specific toward a given antibody (analyte) owing to molecular recognition processes. In addition to discussing the distinct methods for projection and normalization of the data, we demonstrate that an excellent distinction can be made between real samples tested positive for Chagas disease and Leishmaniasis, which could not be achieved with conventional statistical methods. Such high performance probably arose from the possibility of treating the data in the whole frequency range. Through a systematic analysis, it was inferred that Sammon`s mapping with standardization to normalize the data gives the best results, where distinction could be made of blood serum samples containing 10(-7) mg/mL of the antibody. The method inherent in PEx and the procedures for analyzing the impedance data are entirely generic and can be extended to optimize any type of sensor or biosensor.
Resumo:
In this paper, we describe the blue photoluminescence (PL) observed in the multi-component oxosalt phosphor GdVO(4)center dot Ce(3+). Different doping concentrations (0.25-1 mol%) and heat treatment (900-1100 degrees C) were used to evaluate which conditions would lead to the most suitable blue phosphor for optimal display performance. The cerium doping concentration influences the profile of the emission spectrum (broad peak at 412 nm under UV excitation at 330 nm), as reflected on the values of chromaticity coordinates. On the basis of luminescent properties, we can conclude that, among the phosphors prepared in this work the most adequate for a blue display is the one obtained via the combustion method using glycine as fuel, a 0.50 mol% cerium doping concentration, and heat treatment at 1000 degrees C.
Resumo:
In this paper we present some result on sol-gel derived silica-hafnia systems. In particular we focus on fabrication, morphological and spectroscopic assessment of Er(3+)-activated thin films. Two examples of silica-hafnia-derived waveguiding glass ceramics, prepared by top-down and bottom-up techniques are reported, and the main optical properties are discussed. Finally, some properties of activated microspherical resonators, having a silica core, obtained by melting the end of a telecom fiber, coated with an Er(3+)-doped 70SiO(2)-30HfO(2) film, are presented. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
We investigated three amino derivatives of ortho-aminobenzoic or anthranilic acid (o-Abz): a) 2-Amino-benzamide (AbzNH(2)); b) 2-Amino-N-methyl-benzamide (AbzNHCH(3)) and c) 2-Amino-N-N`-dimethyl-bezamide (AbzNH(CH(3))(2)), see Scheme 1. We describe the results of ab-initio calculations on the structural characteristics of the compounds and experimental studies about solvent effects in their absorption and steady-state and time-resolved emission properties. Ab-initio calculations showed higher stability for the rotameric conformation in which the oxygen of carbonyl is near to the nitrogen of ortho-amino group. The derivatives present decrease in the delocalization of pi electron, and absorption bands are blue shifted compared to the parent compound absorption, the extent of the effect increasing from to Abz-NH(2) to Abz-NHCH(3) Abz-NH(CH(3))(2). Measurements performed in several solvents have shown that the the dependence of Stokes shift of the derivatives with the orientational polarizability follows the Onsager-Lippert model for general effects of solvent. However deviation occurred in solvents with properties of Bronsted acids, or electron acceptor characteristics, so that hydrogen bonds formed with protic solvents predominates over intramolecular hydrogen bond. In most solvents the fluorescence decay of AbzNH(2) and AbzNHCH(3) was fitted to a single exponential with lifetimes around 7.0 ns and no correlation with polarity of the solvent was observed. The fluorescence decay of AbzN(CH(3))(2) showed lifetimes around 2.0 ns, consistent with low quantum yield of the compound. The spectroscopic properties of the monoamino derivative AbzNHCH(3) are representative of the properties presented by Abz labelled peptides and fatty acids previously studied.
Resumo:
Vagal Denervation and Neurally Mediated Syncope. A 15-year-old female patient presented with frequent episodes of vasovagal syncope refractory to non-pharmacological and pharmacological measures. Two tilt-table tests performed before and after conventional therapy were positive and reproduced the patient`s clinical symptoms. Selective vagal denervation, guided by HFS, was performed. Six radiofrequency pulses were applied on the left and right sides of the interatrial septum, abolishing vagal responses at these locations. Basal sinus node and Wenckebach cycle lengths changed significantly following ablation. A tilt test performed after denervation was negative and revealed autonomic tone modification. The patient reported significant improvement in quality of life and remained asymptomatic for 9 months after denervation. After this period, three episodes of NMS occurred during a 4-month interval and a tilt test performed 11 months after the procedure demonstrated vagal activity recovery. (J Cardiovasc Electrophysiol, Vol. 20, pp. 558-563, May 2009).
Resumo:
PURPOSE: To determine whether implantation of an intraocular lens (IOL) with an aspheric surface (Akreos AO, Bausch & Lomb Inc) results in reduced ocular aberrations (spherical aberration) and improved Strehl ratio and modulation transfer function (MTF) after cataract surgery. METHODS: In an intraindividual, randomized, double-masked, prospective study of 50 eyes (25 patients) with bilateral cataract, an IOL with modified anterior and posterior surfaces (Akreos AO) was implanted in one eye and a biconvex IOL with spherical surfaces (Akreos Fit, Bausch & Lomb Inc) implanted in the fellow eye. Ocular aberrations, Strehl ratio, and MTF curve with 4.5-, 5.0-, and 6.0-mm pupils were measured with a NIDEK OPD-Scan dynamic retinoscopy aberrometer 3 months after surgery. Uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively) were also measured. RESULTS: No statistically significant difference was noted between eyes in postoperative UDVA and CDVA at 1 month. At 3 months, the Akreos AO IOL group obtained statistically significant lower values of higher order and spherical aberrations with 4.5-, 5.0-, and 6.0-mm pupil diameters than the Akreos Fit IOL group (P<.05). The value of Strehl ratio was statistically significantly higher in eyes with the Akreos AO IOL for 4.5- and 6.0-mm pupils (P<.05). The MTF curve was better in the Akreos AO IOL group in 4.5-, 5.0-, and 6.0-mm pupils (P<.05). CONCLUSIONS: The aspheric Akreos AO IOL induced significantly less spherical aberration than the Akreos Fit IOL for 4.5-, 5.0-, and 6.0-mm pupils. Modulation transfer function and Strehl ratio were also better in eyes implanted with the Akreos AO IOL than the Akreos Fit. [J Refract Surg. 2011;27(4):287-292.] doi:10.3928/1081597X-20100714-01
Resumo:
This study analyzed the genotype distribution and frequency of lamivudine (LAM) and tenofovir (TDF) resistance mutations in a group of patients co-infected with HIV and hepatitis B virus (HBV). A cross-sectional study of 847 patients with HIV was conducted. Patients provided blood samples for HBsAg detection. The load of HBV was determined using an ""in-house"" real-time polymerase chain reaction. HBV genotypes/subgenotypes, antiviral resistance, basal core promoter (BCP), and precore mutations were detected by DNA sequencing. Twenty-eight patients with co-infection were identified. The distribution of HBV genotypes among these patients was A (n = 9; 50%), D (n = 4; 22.2%), G (n = 3; 16.7%), and F (n = 2; 11.1%). Eighteen patients were treated with LAM and six patients were treated with LAM plus TDF. The length of exposure to LAM and TDF varied from 4 to 216 months. LAM resistance substitutions (rtL180M + rtM204V) were detected in 10 (50%) of the 20 patients with viremia. This pattern and an accompanying rtV173L mutation was found in four patients. Three patients with the triple polymerase substitution pattern (rtV173L+ rtL180M + rtM204V) had associated changes in the envelope gene (sE164D + sl195M). Mutations in the BCP region (A1762T, G1764A) and in the precore region (G1896A, G1899A) were also found. No putative TDF resistance substitution was detected. The data suggest that prolonged LAM use is associated with the emergence of particular changes in the HBV genome, including substitutions that may elicit a vaccine escape phenotype. No putative TDF resistance change was detected after prolonged use of TDF. J. Med. Virol. 82:1481-1488, 2010. (C) 2010 Wiley-Liss, Inc.
Resumo:
We have designed, built, and tested an early prototype of a novel subxiphoid access system intended to facilitate epicardial electrophysiology, but with possible applications elsewhere in the body. The present version of the system consists of a commercially available insertion needle, a miniature pressure sensor and interconnect tubing, read-out electronics to monitor the pressures measured during the access procedure, and a host computer with user-interface software. The nominal resolution of the system is <0.1 mmHg, and it has deviations from linearity of <1%. During a pilot series of human clinical studies with this system, as well as in an auxiliary study done with an independent method, we observed that the pericardial space contained pressure-frequency components related to both the heart rate and respiratory rate, while the thorax contained components related only to the respiratory rate, a previously unobserved finding that could facilitate access to the pericardial space. We present and discuss the design principles, details of construction, and performance characteristics of this system.
Resumo:
Background: Tetralogy of Fallot (TOF) is a congenital conotruncal heart defect commonly found in DiGeorge (DGS) and velocardiofacial (VCFS) syndromes. The deletion of chromosome 22q11 has also been demonstrated in sporadic or familial cases of TOF. The aim of the present study was to investigate the frequency of del22q11 in patients with non-syndromic TOF seen at a tertiary Pediatric Cardiology care center. Method: One hundred and twenty three non-syndromic TOF patients were selected and evaluated by history, physical examination and review of medical records. Venous blood was drawn for genomic DNA extraction after informed consent 22q11 microdeletion diagnosis was conducted through a standardized SNP genotyping assay and consecutive homozygosity mapping. Phenotype-genotype correlations regarding cardiac anatomy were conducted. Results: We evaluated 123 non-syndromic TOF patients for a 22q11 deletion. 105 (85.4%) patients presented pulmonary stenosis and 18 (14.6%) had pulmonary atresia. Eight patients (6.5%) were found to have a deletion. Of the deleted patients, three (37.5%) presented pulmonary atresia. We have verified a tendency towards a higher prevalence of pulmonary atresia when comparing TOF patients with and without 22q11 microdeletion. Conclusions: 22q11.2 deletion in non-syndromic TOF patients is present in approximately 6% of patients. We suggest a tendency towards a higher prevalence of pulmonary atresia in non-syndromic TOF patients with 22q11 microdeletion. Molecular genetic screening of non-syndromic TOF patient may be important for the correct care of these patients and a more specific genetic diagnostic and counseling. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Background: Concurrent autoimmune disorders (CAIDs) have been shown to occur in 22% to 34% of the patients with autoimmune hepatitis (AIH). Their presence has been linked to female gender, older age, and to certain HLA antigens, namely HLA-A11. DRB1*04, and DRB4*01. Aims: To assess the frequency and nature of CAID in Brazilian patients with AIH types 1 (AIH-1) and 2 (AIH-2) and to investigate the influence of age, gender, and genetic background in their occurrence. Patients and Methods: The presence and nature of CAID was studied in 143 patients [117 females, median age 11 (1.3 to 69)] with AIH-1 (n = 125) and AIH-2 (n = 28). HLA typing and tumor necrosis factor a gene promoter and exon I cytotoxic T lymphocyte associated antigen 4 (CTLA-4) gene polymorphisms were determined by polymerase chain reaction-based techniques. Results: The frequency of CAID was similar in patients with AIH-1 (14%) and AIH-2 (18%), but their nature was shown to vary. Arthritis was seen in half of the patients (n = 8) with CAID and AIH-1 and in none of those with AIH-2. Subjects with AIH-1 and CAID were shown to be older [24 (1.3 to 6 1) vs. 11 (1.3 to 69) y P = 0.02] and to have more often circulating antinuclear antibody (76% vs. 40%, P = 0.008) and less frequently antiactin antibodies (33% vs. 75%, P = 0.008) when compared with their counterparts without CAID. No particular HLA-DR and DQ alleles, as well as tumor necrosis factor a and CTLA-4 genotypes, were associated with CAID. Conclusions: The nature, but not the frequency, of CAID was shown to vary in AIH-1 and AIH-2. In subjects with AIH-1, CAID was linked to older subjects and to the presence of antinuclear antibody. No predisposition to CAID was associated to HLA-DRB1*04 or DDB4*01 alleles. The observed lower frequency of CAID could be attributed to the lower age of disease onset in Brazilians and to differences in HLA-encoded susceptibility to AIH-1 observed in South America.
Resumo:
Three patients with progressive visual loss, chronic alcoholism and tabagism were submitted to a complete neuro-ophthalmic examination and to retinal nerve fiber layer (RNFL) measurements using optical coherence tomography (OCT) scanning. Two patients showed marked RNFL loss in the temporal sector of the optic disc. However, a third patient presented RNFL measurements within or above normal limits, based on the Stratus-OCT normative database. Such findings may be due to possible RNFL edema similar to the one that may occur in the acute phase of toxic optic neuropathies. Stratus-OCT was able to detect RNFL loss in the papillomacular bundle of patients with tobacco-alcohol-induced toxic optic neuropathy. However, interpretation must be careful when OCT does not show abnormality in order to prevent diagnostic confusion, since overestimation of RNFL thickness measurements is possible in such cases.
Resumo:
PURPOSE: To compare the ability of Fourier-domain (FD) optical coherence tomography (3D OCT-1000; Top, con, Tokyo, Japan) and time domain (TD) OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA) to detect axonal loss in eyes with band atrophy (BA) of the optic nerve. DESIGN: Cross-sectional study. METHODS: Thirty-six eyes from 36 patients with BA and temporal visual field (VF) defect from chiasmal compression and 36 normal eyes were studied. Subjects were submitted to standard automated perimetry and macular and retinal nerve fiber layer (RNFL) measurements were taken using 3D OCT-1000 and Stratus OCT. Receiver operating characteristic (ROC) curves were calculated for each parameter. Spearman correlation coefficients were obtained to evaluate the relationship between RNFL and macular thickness parameters and severity of VF loss. Measurements from the two devices were compared. RESULTS: Regardless of OCT device, all RNFL and macular thickness parameters were significantly lower in eyes with BA compared with normal eyes, but no statistically significant difference was found with regard to the area under the ROC curve. Structure-function relationships were also similar for the two devices. In both groups, RNFL and macular thickness measurements were generally and in some cases significantly smaller with 3D OCT-1000 than with Stratus OCT. CONCLUSIONS: The introduction of FD technology did not lead to better discrimination ability for detecting BA of the optic nerve compared with TD technology when using the software currently provided by the manufacturer. 3D OCT-1000 FD OCT RNFL and macular measurements were generally smaller than TD Stratus OCT measurements. Investigators should be aware of this fact when comparing measurements obtained with these two devices. (Am J Oplathalmol 2009;147: 56-63. (c) 2009 by Elsevier Inc. All rights reserved.)
Resumo:
to test the ability of frequency-doubling technology (FDT) perimetry to detect dysthyroid optic neuropathy (DON). Fifteen eyes of 15 patients with DON and 15 healthy control eyes were studied. Eligible eyes had a diagnosis of DON based on visual field abnormalities on standard automated perimetry and had visual acuity better than 20/30. FDT testing was performed using both the C-20-5 screening test and the C-20 full-threshold test. Normal and DON eyes were compared with regard to FDT mean sensitivity. Sensitivity ranges were 40.0%-86.7% for the screening test, and 53.3%-100.0% (total deviation) and 20.0-93.3 (pattern deviation) for the C-20 threshold test. The corresponding specificity ranges were 86.7-100.0, 33.3-93.3, and 26.7-100.0, respectively. The best sensitivity/specificity ratios were for one abnormal point depressed < 5% in the screening test (86.7%/86.7%), one point depressed < 1% in the total deviation analysis (80.0%/86.7%), and one point depressed < 2% in the pattern deviation analysis (80.0%/86.7%). DON eyes presented significantly lower than normal average sensitivity in the central, pericentral, and peripheral areas. FDT perimetry is a useful screening tool for DON in eyes with normal or only slightly reduced visual acuity.
Resumo:
Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson`s correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.
Resumo:
Olm MA, Kogler JE Jr, Macchione M, Shoemark A, Saldiva PH, Rodrigues JC. Primary ciliary dyskinesia: evaluation using cilia beat frequency assessment via spectral analysis of digital microscopy images. J Appl Physiol 111: 295-302, 2011. First published May 5, 2011; doi:10.1152/japplphysiol.00629.2010.-Ciliary beat frequency (CBF) measurements provide valuable information for diagnosing of primary ciliary dyskinesia (PCD). We developed a system for measuring CBF, used it in association with electron microscopy to diagnose PCD, and then analyzed characteristics of PCD patients. 1 The CBF measurement system was based on power spectra measured through digital imaging. Twenty-four patients suspected of having PCD (age 1-19 yr) were selected from a group of 75 children and adolescents with pneumopathies of unknown causes. Ten healthy, nonsmoking volunteers (age >= 17 yr) served as a control group. Nasal brush samples were collected, and CBF and electron microscopy were performed. PCD was diagnosed in 12 patients: 5 had radial spoke defects, 3 showed absent central microtubule pairs with transposition, 2 had outer dynein arm defects, 1 had a shortened outer dynein arm, and 1 had a normal ultrastructure. Previous studies have reported that the most common cilia defects are in the dynein arm. As expected, the mean CBF was higher in the control group (P < 0.001) and patients with normal ultrastructure (P < 0.002), than in those diagnosed with cilia ultrastructural defects (i.e., PCD patients). An obstructive ventilatory pattern was observed in 70% of the PCD patients who underwent pulmonary function tests. All PCD patients presented bronchial wall thickening on chest computed tomography scans. The protocol and diagnostic techniques employed allowed us to diagnose PCD in 16% of patients in this study.