144 resultados para Optical multi-channel analyzer
Resumo:
Three patients with progressive visual loss, chronic alcoholism and tabagism were submitted to a complete neuro-ophthalmic examination and to retinal nerve fiber layer (RNFL) measurements using optical coherence tomography (OCT) scanning. Two patients showed marked RNFL loss in the temporal sector of the optic disc. However, a third patient presented RNFL measurements within or above normal limits, based on the Stratus-OCT normative database. Such findings may be due to possible RNFL edema similar to the one that may occur in the acute phase of toxic optic neuropathies. Stratus-OCT was able to detect RNFL loss in the papillomacular bundle of patients with tobacco-alcohol-induced toxic optic neuropathy. However, interpretation must be careful when OCT does not show abnormality in order to prevent diagnostic confusion, since overestimation of RNFL thickness measurements is possible in such cases.
Resumo:
PURPOSE: To compare the ability of Fourier-domain (FD) optical coherence tomography (3D OCT-1000; Top, con, Tokyo, Japan) and time domain (TD) OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA) to detect axonal loss in eyes with band atrophy (BA) of the optic nerve. DESIGN: Cross-sectional study. METHODS: Thirty-six eyes from 36 patients with BA and temporal visual field (VF) defect from chiasmal compression and 36 normal eyes were studied. Subjects were submitted to standard automated perimetry and macular and retinal nerve fiber layer (RNFL) measurements were taken using 3D OCT-1000 and Stratus OCT. Receiver operating characteristic (ROC) curves were calculated for each parameter. Spearman correlation coefficients were obtained to evaluate the relationship between RNFL and macular thickness parameters and severity of VF loss. Measurements from the two devices were compared. RESULTS: Regardless of OCT device, all RNFL and macular thickness parameters were significantly lower in eyes with BA compared with normal eyes, but no statistically significant difference was found with regard to the area under the ROC curve. Structure-function relationships were also similar for the two devices. In both groups, RNFL and macular thickness measurements were generally and in some cases significantly smaller with 3D OCT-1000 than with Stratus OCT. CONCLUSIONS: The introduction of FD technology did not lead to better discrimination ability for detecting BA of the optic nerve compared with TD technology when using the software currently provided by the manufacturer. 3D OCT-1000 FD OCT RNFL and macular measurements were generally smaller than TD Stratus OCT measurements. Investigators should be aware of this fact when comparing measurements obtained with these two devices. (Am J Oplathalmol 2009;147: 56-63. (c) 2009 by Elsevier Inc. All rights reserved.)
Resumo:
Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson`s correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.
Resumo:
PURPOSE. To evaluate the effect of disease severity and optic disc size on the diagnostic accuracies of optic nerve head (ONH), retinal nerve fiber layer (RNFL), and macular parameters with RTVue (Optovue, Fremont, CA) spectral domain optical coherence tomography (SDOCT) in glaucoma. METHODS. 110 eyes of 62 normal subjects and 193 eyes of 136 glaucoma patients from the Diagnostic Innovations in Glaucoma Study underwent ONH, RNFL, and macular imaging with RTVue. Severity of glaucoma was based on visual field index (VFI) values from standard automated perimetry. Optic disc size was based on disc area measurement using the Heidelberg Retina Tomograph II (Heidelberg Engineering, Dossenheim, Germany). Influence of disease severity and disc size on the diagnostic accuracy of RTVue was evaluated by receiver operating characteristic (ROC) and logistic regression models. RESULTS. Areas under ROC curve (AUC) of all scanning areas increased (P < 0.05) as disease severity increased. For a VFI value of 99%, indicating early damage, AUCs for rim area, average RNLI thickness, and ganglion cell complex-root mean square were 0.693, 0.799, and 0.779, respectively. For a VFI of 70%, indicating severe damage, corresponding AUCs were 0.828, 0.985, and 0.992, respectively. Optic disc size did not influence the AUCs of any of the SDOCT scanning protocols of RTVue (P > 0.05). Sensitivity of the rim area increased and specificity decreased in large optic discs. CONCLUSIONS. Diagnostic accuracies of RTVue scanning protocols for glaucoma were significantly influenced by disease severity. Sensitivity of the rim area increased in large optic discs at the expense of specificity. (Invest Ophthalmol Vis Sci. 2011;92:1290-1296) DOI:10.1167/iovs.10-5516
Resumo:
There is increasing evidence of a reciprocal fronto-limbic network in the pathogenesis of mood disorders. Prior in vivo proton ((1)H) spectroscopy studies provide evidence of abnormal neurochemical levels in the cingulate and dorsolateral prefrontal cortex (DLPFC) of adult subjects with major depressive disorder (MOD). We examined whether similar abnormalities occur in children and adolescents with MDD. We collected two-dimensional multi-voxel in vivo 1H spectroscopy data at 1.5 Tesla to quantify levels of N-acetyl-aspartate (NAA), glycerolphosphocholine plus phosphocholine (GPC + PC), and phosphocreatine plus creatine (PCr + Cr) in the DLPFC, medial prefrontal cortex (MPFC), and anterior cingulate (AC) of children and adolescents aged 8-17 years with MDD (n = 16) compared with healthy control subjects (n = 38). Analysis of covariance with age and gender as covariates was performed. MDD subjects showed significantly lower levels of NAA in the right MPFC and right AC than controls. MDD subjects also had significantly lower levels of GPC + PC in the right AC than control subjects. There were no significant differences in other metabolites in the studied regions. Pediatric patients with MDD exhibit neurochemical alterations in prefrontal cortex regions that are important in the monitoring and regulation of emotional states. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a (192)Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the (192)Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the 192Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0 +/- 1.0 and 17.3 +/- 1:2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of vertical bar a vertical bar = 113 cm/s(2). In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors` knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3483780]
Resumo:
Congenital hyperinsulinism (CHI) is a rare pancreatic beta-cell disease of neonates, characterized by inappropriate insulin secretion with severe persistent hypoglycemia, with regard to which many questions remain to be answered, despite the important acquisition of its molecular mechanisms in the last decade. The aim of this study was to examine pancreatic histology, beta-cell proliferation (immunohistochemistry with double staining for Ki-67/insulin), and beta-cell adenosine triphosphate-sensitive potassium channels genes from 11 Brazilian patients with severe medically unresponsive CHI who underwent pancreatectomy. Pancreatic histology and beta-cell proliferation in CHI patients were compared to pancreatic samples from 19 age-matched controls. Ten cases were classified as diffuse form (D-CHI) and 1 as focal form (F-CHI). beta-cell nucleomegaly and abundant cytoplasm were absent in controls and were observed only in D-CHI patients. The Ki-67 labeling index (Ki-67-LI) was used to differentiate the adenomatous areas of the F-CHI case (10.15%) from the ""loose cluster of islets`` found in 2 D-CHI samples (2.29% and 2.43%) and 1 control (1.54%) sample. The Ki-67-LI was higher in the F-CHI adenomatous areas, but D-CHI patients also had significantly greater Ki-67-LI (mean value = 2.41%) than age-matched controls (mean value = 1.87%) (P = 0.009). In this 1st genetic study of CHI patients in Brazil, no mutations or new polymorphisms were found in the 33-37 exons of the ABCC8 gene (SUR1) or in the entire exon of the KCNJ11 gene (Kir 6.2) in 4 of 4 patients evaluated. On the other hand, enhanced beta-cell proliferation seems to be a constant feature in CHI patients, both in diffuse and focal forms.
Resumo:
Purpose: To evaluate retinal nerve fiber layer (RNFL), optic nerve head (ONH), and macular thickness measurements for glaucoma detection using the RTVue spectral domain optical coherence tomograph. Design: Diagnostic, case-control study. Participants: One hundred forty eyes of 106 glaucoma patients and 74 eyes of 40 healthy subjects from the Diagnostic Innovations in Glaucoma Study (DIGS). Methods: All patients underwent ocular imaging with the commercially available RTVue. Optic nerve head, RNFL thickness, and macular thickness scans were obtained during the same visit. Receiver operating characteristic (ROC) curves and sensitivities at fixed specificities (80% and 95%) were calculated for each parameter. Main Outcome Measures: Areas under the ROC curves (AUC) and sensitivities at fixed specificities of 80% and 95%. Results: The AUC for the RNFL parameter with best performance, inferior quadrant thickness, was significantly higher than that of the best-performing ONH parameter, inferior rim area (0.884 vs 0.812, respectively; P = 0.04). There was no difference between ROC curve areas of the best RNFL thickness parameters and the best inner macular thickness measurement, ganglion cell complex root mean square (ROC curve area = 0.870). Conclusions: The RTVue RNFL and inner retinal macular thickness measurements had good ability to detect eyes with glaucomatous visual field loss and performed significantly better than ONH parameters.
Resumo:
Background: Oncologic outcomes in men with radiation-recurrent prostate cancer (PCa) treated with salvage radical prostatectomy (SRP) are poorly defined. Objective: To identify predictors of biochemical recurrence (BCR), metastasis, and death following SRP to help select patients who may benefit from SRP. Design, setting, and participants: This is a retrospective, international, multi-institutional cohort analysis. There was amedian follow-up of 4.4 yr following SRP performed on 404 men with radiation-recurrent PCa from 1985 to 2009 in tertiary centers. Intervention: Open SRP. Measurements: BCR after SRP was defined as a serum prostate-specific antigen (PSA) >= 0.1 or >= 0.2 ng/ml (depending on the institution). Secondary end points included progression to metastasis and cancerspecific death. Results and limitations: Median age at SRP was 65 yr of age, and median pre-SRP PSA was 4.5 ng/ml. Following SRP, 195 patients experienced BCR, 64 developed metastases, and 40 died from PCa. At 10 yr after SRP, BCR-free survival, metastasis-free survival, and cancer-specific survival (CSS) probabilities were 37% (95% confidence interval [CI], 31-43), 77% (95% CI, 71-82), and 83% (95% CI, 76-88), respectively. On preoperative multivariable analysis, pre-SRP PSA and Gleason score at postradiation prostate biopsy predicted BCR (p = 0.022; global p < 0.001) and metastasis (p = 0.022; global p < 0.001). On postoperative multivariable analysis, pre-SRP PSA and pathologic Gleason score at SRP predicted BCR (p = 0.014; global p < 0.001) and metastasis (p < 0.001; global p < 0.001). Lymph node involvement (LNI) also predicted metastasis (p = 0.017). The main limitations of this study are its retrospective design and the follow-up period. Conclusions: In a select group of patients who underwent SRP for radiation-recurrent PCa, freedom from clinical metastasis was observed in > 75% of patients 10 yr after surgery. Patients with lower pre-SRP PSA levels and lower postradiation prostate biopsy Gleason score have the highest probability of cure from SRP. (C) 2011 European Association of Urology. Published by Elsevier B. V. All rights reserved.
Resumo:
Suicidal behaviours are one of the most important contributors to the global burden of disease among women, but little is known about prevalence and modifiable risk factors in low and middle income countries. We use data from the WHO multi-country study on women`s health and domestic violence against women to examine the prevalence of suicidal thoughts and attempts, and relationships between suicide attempts and mental health status, child sexual abuse, partner violence and other variables. Population representative cross-sectional household surveys were conducted from 2000-2003 in 13 provincial (more rural) and city (urban) sites in Brazil, Ethiopia, japan, Namibia, Peru, Samoa, Serbia, Thailand and Tanzania. 20967 women aged 15-49 years participated. Prevalence of lifetime suicide attempts, lifetime suicidal thoughts, and suicidal thoughts in the past four weeks were calculated, and multivariate logistic regression models were fit to examine factors associated with suicide attempts in each site. Prevalence of lifetime suicide attempts ranged from 0.8% (Tanzania) to 12.0% (Peru city): lifetime thoughts of suicide from 7.2% (Tanzania province) to 29.0% (Peru province), and thoughts in the past four weeks from 1.9% (Serbia) to 13.6% (Peru province). 25-50% of women with suicidal thoughts in the past four weeks had also visited a health worker in that time. The most consistent risk factors for suicide attempts after adjusting for probable common mental health disorders were: intimate partner violence, non-partner physical violence, ever being divorced, separated or widowed, childhood sexual abuse and having a mother who had experienced intimate partner violence. Mental health policies and services must recognise the consistent relationship between violence and suicidality in women in low and middle income countries. Training health sector workers to recognize and respond to the consequences of violence may substantially reduce the health burden associated with suicidal behaviour. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
PURPOSE. To evaluate the relationship between pattern electroretinogram (PERG) amplitude, macular and retinal nerve fiber layer (RNFL) thickness by optical coherence tomography (OCT), and visual field (VF) loss on standard automated perimetry (SAP) in eyes with temporal hemianopia from chiasmal compression. METHODS. Forty-one eyes from 41 patients with permanent temporal VF defects from chiasmal compression and 41 healthy subjects underwent transient full-field and hemifield (temporal or nasal) stimulation PERG, SAP and time domain-OCT macular and RNFL thickness measurements. Comparisons were made using Student`s t-test. Deviation from normal VF sensitivity for the central 18 of VF was expressed in 1/Lambert units. Correlations between measurements were verified by linear regression analysis. RESULTS. PERG and OCT measurements were significantly lower in eyes with temporal hemianopia than in normal eyes. A significant correlation was found between VF sensitivity loss and fullfield or nasal, but not temporal, hemifield PERG amplitude. Likewise a significant correlation was found between VF sensitivity loss and most OCT parameters. No significant correlation was observed between OCT and PERG parameters, except for nasal hemifield amplitude. A significant correlation was observed between several macular and RNFL thickness parameters. CONCLUSIONS. In patients with chiasmal compression, PERG amplitude and OCT thickness measurements were significant related to VF loss, but not to each other. OCT and PERG quantify neuronal loss differently, but both technologies are useful in understanding structure-function relationship in patients with chiasmal compression. (ClinicalTrials.gov number, NCT00553761.) (Invest Ophthalmol Vis Sci. 2009; 50: 3535-3541) DOI:10.1167/iovs.08-3093
Resumo:
Objective Obstructive sleep apnea (OSA) and hypertension (HYP) frequently coexist and have additive harmful effects on the cardiovascular system. There is also growing evidence that short sleep duration may contribute independently to poor cardiovascular outcome. The aim of this study was to evaluate the potential influence of antihypertensive medication on sleep parameters objectively measured by standard polysomnography in hypertensive patients with OSA. Methods We evaluated consecutive patients with a recent diagnosis of OSA by full polysomnography (apnea hypopnea index >= 5 events/h) and HYP. Smokers, patients with diabetes mellitus, heart failure, or using hypnotics and benzodiazepines were excluded. Results We evaluated 186 hypertensive patients with OSA, 64% men. All patients were on at least one antihypertensive medication, including angiotensin-converting enzyme inhibitors (37%), beta-blockers (35%), angiotensin receptor blockers (32%), diuretics (29%) and calcium channel blockers (21%). Backward multiple regression analysis showed that age (P <= 0.001) and the use of calcium channel blockers (P=0.037) were the only factors inversely associated with lower total sleep time. Sleep efficiency was inversely associated only with age (P <= 0.001), whereas the use of calcium channel blockers had a nonsignificant trend (P=0.092). Use of calcium channel blockers was associated with significant reduction in total sleep time (-41 min, P=0.005) and 8% lower sleep efficiency (P=0.004). No other antihypertensive medication, including diuretics and beta-blockers, was associated with sleep impairment. Conclusion Calcium channel blockers may impact negatively on sleep duration in hypertensive patients with OSA. The mechanisms and significance of this novel finding warrants further investigation. J Hypertens 29: 1236-1241 (C) 2011 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
Resumo:
This study investigated the genetic characteristics of Toxoplasma gondii samples collected from 62 patients with toxoplasmosis in Sao Paulo State, Brazil. DNA samples were isolated from blood, cerebrospinal fluid and amniotic fluids of 25 patients with cerebral toxoplasmosis and AIDS, two patients with acute toxoplasmosis, 12 patients with ocular toxoplasmosis, six newborns with congenital toxoplasmosis and 17 pregnant women with acute infection. Diagnosis of toxoplasmosis was based in clinical, radiological and laboratory features. Genotyping was performed using multilocus PCR-RFLP genetic markers including SAG1, SAG2, 5`- and 3`-SAG2, alt.SAG2, SAG3, BTUB, GRA6, C22-8, c29-2, L358, PK1 and Apico. Among the 62 clinical samples, 20 (32%) were successfully genotyped at eight or more genetic loci and were grouped to three distinct genotypes. Eighteen samples belonged to ToxoDB Genotype #65 and the other two samples were identified as ToxoDB Genotypes #6 and #71, respectively (http://toxodb.org/toxo/). Patients presenting Genotypes #6 and #71 had severe and atypical cerebral toxoplasmosis, characterized by diffuse encephalitis without extensive brain lesions. These results indicate that T. gondii Genotype #65 may have a high frequency in causing human toxoplasmosis in Sao Paulo State, Brazil. This unusual finding highlights the need to investigate the possible association of parasite genotypes with human toxoplasmosis. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
Phosphodiesterase type-5 (PDE5) specifically cleaves cyclic guanosine monophosphate (cGMP), a key intracellular secondary messenger. The PDE5 inhibitor sildenafil is a well-known vasodilator that also has gastrointestinal myorelaxant properties. In the present study, we further investigated sildenafil-induced myorelaxation in rat isolated duodenum, assessing its interaction with nitric oxide (NO) synthase and K+ channel opening. The spontaneous contractions of duodenal strips were reversibly inhibited by sildenafil (0.1-300 mu M) in a concentration-dependent manner [mean (95% confidence interval); EC50 = 6.8 (2.7-17.3) mu M]. The sildenafil-induced myorelaxation was significantly decreased by the NO synthase inhibitor N-nitro-L-arginine methyl ester [increasing the EC50 value to 41.9 (26.1-67.3) mu M]. Sodium nitroprusside or forskolin pretreatments enhanced the sildenafil-induced myorelaxation. In isolated strips pretreated with BaCl2 (0.2 mM), 4-aminopyridine (4-AP, 3 mM), or glybenclamide (1 mu M), the sildenafil-induced EC50 value was significantly increased to 32.8 (19.1-56.4), 27.1 (15.2-48.3) and 20.1 (16.4-24.7) mu M, respectively. Minoxidil (50 mu M) or diazoxide (100 mu M) also significantly attenuated the sildenafil-induced potency. In conclusion, the NO synthase/cyclic nucleotide pathway activation is involved in sildenafil-induced inhibition of spontaneous duodenal contractions. Its pharmacological action seems to be influenced by K+ channel opening, especially the voltage-sensitive ones, being inhibited by 4-AP and K-ATP channels, sensitive to glybenclamide.
Resumo:
In the present study, the participation of the Na(v)1.8 sodium channel was investigated in the development of the peripheral pro-nociceptive state induced by daily intraplantar injections of PGE(2) in rats and its regulation in vivo by protein kinase A (PKA) and protein kinase C epsilon (PKC epsilon) as well. In the prostaglandin E(2) (PGE(2))-induced persistent hypernociception, the Na(v)1.8 mRNA in the dorsal root ganglia (DRG) was up-regulated. The local treatment with dipyrone abolished this persistent hypernociception but did not alter the Na(v)1.8 mRNA level in the DRG. Daily intrathecal administrations of antisense Na(v)1.8 decreased the Na(v)1.8 mRNA in the DRG and reduced ongoing persistent hypernociception. once the persistent hypernociception had been abolished by dipyrone, but not by Na(v)1.8 antisense treatment, a small dose of PGE(2) restored the hypernociceptive plateau. These data show that, after a period of recurring inflammatory stimuli, an intense and prolonged nociceptive response is elicited by a minimum inflammatory stimulus and that this pro-nociceptive state depends on Na(v)1.8 mRNA up-regulation in the DRG. in addition, during the persistent hypernociceptive state, the PKA and PKC epsilon expression and activity in the DRG are up-regulated and the administration of the PKA and PKC epsilon inhibitors reduce the hypernociception as well as the Na(v)1.8 mRNA level. In the present study, we demonstrated that the functional regulation of the Na(v)1.8 mRNA by PKA and PKC epsilon in the primary sensory neuron is important for the development of the peripheral pro-nociceptive state induced by repetitive inflammatory stimuli and for the maintenance of the behavioral persistent hypernociception. (C) 2008 Elsevier Inc. All rights reserved.