129 resultados para Hospital of the Five Wounds


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our objective was to compare the polymerization stress (sigma(pol)) of a series of composites obtained using poly(methyl methacrylate) (PMMA) or glass as bonding substrates, and to compare the results with those from in vitro microleakage of composite restorations. The tested hypothesis was that stress values obtained in a less rigid testing system (i.e. using PMMA) would show a better relationship with microleakage data. Five dental composites were tested: Filtek Z250 (FZ), Z100 (Z1), Concept (CO), Durafill (DU) and Heliomolar (HM). sigma(pol) was determined in 1 mm high specimens inserted between two rods (empty set = 5 mm) of either PMMA or glass. The composite elastic modulus (E) was obtained by three-point bending. sigma(pol) and E data were submitted to a one-way analysis of variance/Tukey test (alpha = 0.05). For the microleakage test (MI), bovine incisors received cylindrical cavities (empty set = 5 mm, h = 2 mm), which were restored in bulk. After storage for 24 h in water, specimens were subjected to dye penetration using AgNO(3) as tracer. Specimens were sectioned twice, perpendicularly, and microleakage was measured (in millimeters) under 20x magnification. Data from MI were submitted to the Kruskal-Wallis test. Means (SD) of sigma(pol) (MPa) using glass/PMMA were FZ: 7.5(1.8)(A)/2.5(0.2)(bc); Z1: 7.3(0.5)(A)/2.8(0.3)(ab); CO: 6.8(1.1)(A)/3.2(0.5)(a); DU: 4.5(0.7)(B)/2.0(0.2)(bc); HM: 3.5(0.2)(B)/2.3(0.3)(c). sigma(pol) obtained using PMMA rods were 34-67% lower than with glass. Means (SD) for tooth average/tooth maximum microleakage were FZ: 0.92(0.19)(B)/1.53(0.30)(a); Z1: 1.19(0.21)(A)/1.75(0.20)(a); CO: 1.26(0.25)(A)/1.78(0.24)(a); DU: 0.83(0.30)(B)/1.68(0.46)(a): HM: 0.81(0.27)(B)/1.64(0.54)(a). The tested hypothesis was confirmed, as the composites showed the same ordering both in the polymerization stress test using PMMA rods and in the microleakage test. (C) 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the effect of the C-factor and dentin preparation method (DPM) in the bond strength (BS) of a mild self-etch adhesive; the study also observed the SEM superficial aspects of the corresponding smear layer. For purposes of this study, 25 molars (n=5) were used in a bond strength test. The molars were divided into two parts (buccal and lingual): one part received a Class V cavity (C-factor=3) and the other received a flat surface (C-factor=0) with the same bur type (coarse diamond or carbide bur and fine diamond or carbide bur), both within the same dentin depth. Five teeth were prepared with wet 60-grit and 600-grit SiC papers. After restoration with Clearfil SE Bond, microtensile beans (0.8 mm(2)) were prepared and tested after 24 hours in a universal testing machine (0.5 mm/minute). An additional two teeth for each DPM were prepared for SEM evaluation of the smear layer superficial aspects. The BS values were submitted to one-way ANOVA, considering only the DPM (flat surfaces) and two-way ANOVA (C-Factor x DPM, considering only burs) with p=0.05. Although the DPM in the flat surfaces was not significant, the standard deviations of carbide bur-prepared specimens were markedly lower. The BS was significantly lower in cavities. The fine carbide bur presented the most favorable smear layer aspect. It was concluded that different dentin preparation methods could not prevent the adverse effect in bond strength of a high C-factor. A coarse cut carbide bur should be avoided prior to a mild self-etch adhesive, because it adversely affected bond strength. In contrast, a fine cut carbide bur provided the best combination: high bond strength with low variability, which suggests a more reliable bond strength performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. The aim of the present study was to evaluate the radiopacity of 5 root end filling materials (white MTA Angelus, MTA Bio, light-cured MTA, Sealepox RP, and Portland cement clinker with bismuth oxide and calcium sulfate). Method. Five specimens, 10 mm in diameter and 1 mm in thickness according to specification ISO 6876: 2001 were fabricated from each material and radiographed using Insigth occlusal films close to a graduated aluminum step-wedge (2 to 16 mm in thickness). Radiographs were digitized and compared to the aluminum step-wedge. The radiographic density data were converted into millimeters of aluminum (mm Al), using the Digora 1.51 software. Results were evaluated statistically using the analysis of variance (ANOVA) followed by Tukey test. The level of significance was set at 5% (P<.05%). Results. Radiopacity values ranged from 1.21 mm Al (light-cured MTA) to 6.45 mm Al (MTA Angelus). Comparison between materials showed significant difference (P<.05) between MTA Angelus and all other materials, between Sealepox RP and MTA Bio, and between light-cured MTA and Portland cement clinker. Light-cured MTA was significantly less radiopaque than all other materials. No significant difference (P>.05) was found between MTA Bio and Portland cement clinker. Conclusions. All retrograde filling materials evaluated showed greater radiopacity than dentin. All the materials, except light-cured MTA met the minimum radiopacity standards of 3 mm Al recognized by the ISO 6876: 2001 and ADA n.57. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: e35-e38)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The purpose of this study was to evaluate the papilla level adjacent to single-tooth implants in the maxillary anterior region in individuals with cleft lip, alveolus, and palate to verify whether there is correlation among the vertical distance, horizontal distance, dental/prosthetic crown shape, and periodontal/peri-implant biotype with the presence of interproximal papilla. Design: Cross-sectional. Setting: Hospital for Rehabilitation of Craniofacial Anomalies, University of Sao Paulo (HRAC/USP). Patients: 77 papillae in 40 patients. Interventions: The periodontal/peri-implant biotype was clinically evaluated and characterized as thin or thick. Intraoral photographs were used to evaluate the presence or absence of papilla. Main Outcome Measures: Classification in scores (0 to 3) and determination of length (CL) and width (CW) of crowns adjacent to papillae. The CW/CL ratio was calculated for each crown in order to characterize it as square-shaped or triangular-shaped. The vertical and horizontal distances were obtained by radiographic evaluation. Results: The correlations between vertical distance and papilla score and horizontal distance and papilla score were statistically significant (p= .02 and p = .01). There was no significant difference between crown shape and periodontal/peri-implant biotype in distinct correlations with the papilla score (p = .41 and p = .07). Conclusion: The results suggest that the vertical and horizontal distances may have independent or combined relationship with the existence of interproximal papilla; the periodontal/peri-implant biotype (phenotype) was not correlated with the presence or absence of papilla, as well as the shape of the dental/prosthetic crown.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the repair of critical-size bone defects in rats treated with demineralized bovine bone (DBB) compared with autogenous bone (AB). Material and method: A bone defect of 8 mm in diameter was created in the calvaria of 50 Rattus norvegicus, treated either with DBB or AB. Sub-groups of five rats of each group were killed at 7, 14, 21, 30 and 90 days post-operatively, and the skulls were removed and processed histologically. Histological sections were stained with hematoxylin and eosin. Result: Histological analysis showed complete closure of the defects with new bone at 90 days in group AB, and substitution of the biomaterial by fibrotic connective tissue in the DBB group at 21 days. Morphometric analysis showed that DBB was rapidly absorbed at 14 days, with its volume density decreasing from 47%+/- 0.8% at 7 days to 1.2%+/- 0.41% at 14 days. Subsequently, volume densities of the connective tissue and neoformed bone increased from 51.1%+/- 11.17% to 86.8%+/- 7.92% and from 1.9%+/- 1.13% to 12%+/- 8.02%, respectively, for the same time interval. The volume density of AB particles did not change throughout the experimental periods, but the amount of new bone increased markedly between 7 and 90 days, from 4.5%+/- 1.57% to 53.5%+/- 6.42% (P < 0.05). Conclusion: DBB did not provide complete repair of the defects, with significantly less new bone formation than in the AB group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. The aim of this study was to identify the behavior of masticatory muscles after fractures of the zygomatico-orbital complex (ZOC) and subsequent surgical treatment, by using analyses of bite force, electromyography (EMG), and mandible mobility during a 6-month period after surgery. Study design. Five patients with fractured ZOCs treated surgically by using an intraoral approach and fixation exclusively in the region of the zygomaticomaxillary buttress were evaluated. The control group included 12 other patients. During postoperative follow-up, bite force, mandible mobility, and EMG analysis of the masticatory muscles were evaluated. Results. There was an increase in bite force with time, but a decline in EMG activity during the same period. In the mandible mobility analysis, only maximum mouth-opening values increased significantly after the surgical treatment. Conclusions. The masticatory musculature, according to bite force and EMG, returned to its normal condition by the second month after surgery, and maximum mouth opening was observed after the first month. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111:e1-e7)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to analyze the immediate effect of resilient splints through surface electromyography testing and to compare the findings with the electromyographic profiles of asymptomatic subjects. The participants were 30 subjects, 15 patients with TMD (TMD Group) and 15 healthy subjects (Control Group), classified according to Research Diagnostic Criteria (RDC/TMD) Axis I. A resilient occlusal splint was made for each patient in the TMD Group from two mm thick silicon to cover all teeth. The EMG examination was performed before and immediately after installing the splint. Three tests were performed as follows: 1. Maximum Voluntary Contraction (MVC) using cotton rolls (standards test); 2. MVC in maximal intercuspation position; and 3. MVC with the splint in position. The EMG signal was recorded for five seconds. EMG indices were calculated to assess muscle symmetry, jaw torque, and impact. There was a statistically significant difference when comparing the results among the study groups. The symmetry index values in the Control Group were higher than the TMD Initial Group and similar to the TMD Group after the installation of the splint. The index values of torque were higher in TMD Initial Group when compared with the Controls. Impact values were lower than normal values in the TMD Initial Group and restored upon installation of the splint. The resilient occlusal splints may be used as complementary or adjunctive treatment of temporomandibular disorders.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The double system of support, in which the distal-extension removable partial denture adapts, causes inadequate stress around abutment teeth, increasing the possibility of unequal bone resorption. Several ways to reduce or more adequately distribute the stress between abutment teeth and residual ridges have been reported; however, there are no definitive answers to the problem. The purpose of this study was to analyze, by means of photoelasticity, the most favorable stress distribution using three retainers: T bar, rest, proximal plate, I bar (RPI), and circumferential with mesialized rest. Materials and Methods: Three photoelastic models were made simulating a Kennedy Class II inferior arch. Fifteen dentures with long saddles, five of each design, were adjusted to the photoelastic patterns and submitted first to uniformly distributed load, and then to a load localized on the last artificial tooth. The saddles were then shortened and the tests repeated. The quantitative and qualitative analyses of stress intensity were done manually and by photography, respectively. For intragroup analyses the Wilcoxon test for paired samples was used, while for intergroup analyses Friedman and Wilcoxon tests were used to better identify the differences (p < 0.05). Results: The RPI retainer, followed by the T bar, demonstrated the best distribution of load between teeth and residual ridge. The circumferential retainer caused greater concentration of stress between dental apexes. Stress distribution was influenced by the type of retainer, the length of the saddle, and the manner of load application. Conclusions: The long saddles and the uniformly distributed loads demonstrated better distribution of stress on support structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

P>Aim To evaluate by 3D profilometry and scanning electron microscopy (SEM), the marginal adaptation of mineral trioxide aggregate (MTA) and Sealer 26 placed in root-end cavities with direct vision or under an optical microscope. Methodology The root ends of 52 root filled canine teeth were filled with MTA or Sealer 26 under direct vision or optical microscope (n = 13). In each group, eight specimens were analysed by profilometry for measurement of the area and depth of gaps. In the other five specimens, gap area was measured using SEM to verify marginal adaptation and surface characteristic. Data were analysed by parametric (anova and Tukey) and non-parametric (Kruskal-Wallis and Dunn) tests. Results The assessment of the adaptation of both materials to dentine was not influenced by the mode of visualization, which was confirmed by both profilometry and SEM observations. The voids measured with profilometry for Sealer 26 under direct vision were significantly wider and deeper than those for MTA under direct vision (P < 0.05). In SEM, significantly larger gap areas were observed with Sealer 26 (P < 0.05). Conclusion Root-end cavities filled with MTA had smaller gaps and better marginal adaptation than Sealer 26.