126 resultados para Aerial behavior


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the effect of the ion exchange treatment on the R-curve behavior of a leucite-reinforced dental porcelain, testing the hypothesis that the ion exchange is able to improve the R-curve behavior of the porcelain studied. Porcelain disks were sintered, finely polished, and submitted to an ion exchange treatment with a KNO(3) paste. The R-curve behavior was assessed by fracturing the specimens in a biaxial flexure design after making Vickers indentations in the center of the polished surface with loads of 1.8, 3.1, 4.9, 9.8, 31.4, and 49.0 N. The results showed that the ion exchange process resulted in significant improvements in terms of fracture toughness and flexural strength as compared to the untreated material. Nevertheless, the rising R-curve behavior previously observed in the control group disappeared after the ion exchange treatment, i.e., fracture toughness did not increase with the increase in crack size for the treated group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To investigate the processing induced particle alignment on fracture behavior of four multiphase dental ceramics (one porcelain, two glass-ceramics and a glass-infiltrated-alumina composite). Methods. Disks (empty set12mm x 1.1 mm-thick) and bars (3 mm x 4 mm x 20 mm) of each material were processed according to manufacturer instructions, machined and polished. Fracture toughness (K(IC)) was determined by the indentation strength method using 3-point bending and biaxial flexure fixtures for the fracture of bars and disks, respectively. Microstructural and fractographic analyses were performed with scanning electron microscopy, energy dispersive spectroscopy and X-ray diffraction. Results. The isotropic microstructure of the porcelain and the leucite-based glass-ceramic resulted in similar fracture toughness values regardless of the specimen geometry. On the other hand, materials containing second-phase particles with high aspect ratio (lithium disilicate glass-ceramic and glass-infiltrated-alumina composite) showed lower fracture toughness for disk specimens compared to bars. For the lithium disilicate glass-ceramic disks, it was demonstrated that the occurrence of particle alignment during the heat-pressing procedure resulted in an unfavorable pattern that created weak microstructural paths during the biaxial test. For the glass-infiltrated-alumina composite, the microstructural analysis showed that the large alumina platelets tended to align their large surfaces perpendicularly to the direction of particle deposition during slip casting of green preforms. Significance. The fracture toughness of dental ceramics with anisotropic microstructure should be determined by means of biaxial testing, since it results in lower values. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tonic immobility behavior (TI) is an innate response characterized by profound motor inhibition that is exhibited by prey when physical contact with a predator is prolonged and the situation inescapable. The periaqueductal gray matter (PAG) is intimately associated with the somatic and autonomic components of defensive reactions. This study investigated whether the TI response was able to recruit specific functional columns of the PAG by examining c-fos immunolocalization in guinea pigs. In the TI group, the innate response was invoked in animals through inversion and physical contention for at least 15 min. In the control group, the animals were physically manipulated only. Our results demonstrate that the defensive behavior of TI is capable of promoting the expression of Fos protein in different areas of the PAG, with higher levels of staining in the ventrolateral (vI) and lateral (I) columns. In addition, our results demonstrate increased Fos immunoreactivity (FOS-IR) in the dorsal raphe nucleus, the Edinger-Westphal nucleus, the cuneiform nucleus and the superior colliculus. In contrast, there were no significant alterations in the number of FOS-IR cells in the inferior colliculus or the oculomotor nucleus. Analysis of the results suggests that neuronal activation after the TI response differs by functional column of the PAG. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tonic immobility (TI) is a temporary state of profound motor inhibition induced by situations that generate intense fear, with the objective of protecting an animal from attacks by predators. A preliminary study by our group demonstrated that microinjection into the basolateral nucleus of the amygdala (BLA) of an agonist to 5-HT(1A) and 5-HT(2) receptors promoted a decrease in TI duration. In the current study, the effects of GABAergic stimulation of the BLA and the possible interaction between GABA(A) and 5-HT(2) receptors on TI modulation were investigated. Observation revealed that GABAergic agonist muscimol (0.26 nmol) reduced the duration of TI episodes, while microinjection of the GABAergic antagonist bicuculline (1 nmol) increased TI duration. Additionally, microinjection of 5-HT(2) agonist receptors (alpha-methyl-5-HT, 0.32 nmol) into the BLA decreased TI duration, an effect reversed by pretreatment with bicuculline (at the dose that had no effect per se, 0.2 nmol). Moreover, the activation of GABA(A) and 5-HT(2) receptors in the BLA did not alter the spontaneous motor activity in the open field test. These experiments demonstrated that the activation of GABA(A) and 5-HT(2) receptors of the BLA possibly produce a reduction in unconditioned fear that decreases the TI duration in guinea pigs, but this is not due to increased spontaneous motor activity, which could affect a TI episode nonspecifically. Furthermore, these results suggest an interaction between GABAergic and serotoninergic mechanisms mediated by GABA(A) and 5-HT(2) receptors. In addition, the GABAergic circuit of the BLA presents a tonic inhibitory influence on TI duration. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: (1) To compare the anatomopathological variables and recurrence rates in patients with early-stage adenocarcinoma (AC) and squamous cell carcinoma (SCC) of the uterine cervix; (2) to identify the independent risk factors for recurrence. Study design: This historical cohort study assessed 238 patients with carcinoma of the uterine cervix (113 and IIA), who underwent radical hysterectomy with pelvic lymph node dissection between 1980 and 1999. Comparison of category variables between the two histological types was carried out using the Pearson`s X-2 test or Fisher exact test. Disease-free survival rates for AC and SCC were calculated using the Kaplan-Meier method and the curves were compared using the log-rank test. The Cox proportional hazards model was used to identify the independent risk factors for recurrence. Results: There were 35 cases of AC (14.7%) and 203 of SCC (85.3%). AC presented lower histological grade than did SCC (grade 1: 68.6% versus 9.4%; p < 0.001), lower rate of lymphovascular space involvement (25.7% versus 53.7%; p = 0.002), lower rate of invasion into the middle or deep thirds of the uterine cervix (40.0% versus 80.8%; p < 0.001) and lower rate of lymph node metastasis (2.9% versus 16.3%; p = 0.036). Although the recurrence rate was lower for AC than for SCC (11.4% versus 15.8%), this difference was not statistically significant (p = 0.509). Multivariate analysis identified three independent risk factors for recurrence: presence of metastases in the pelvic lymph nodes, invasion of the deep third of the uterine cervix and absence of or slight inflammatory reaction in the cervix. When these variables were adjusted for the histological type and radiotherapy status, they remained in the model as independent risk factors. Conclusion: The AC group showed less aggressive histological behavior than did the SCC group, but no difference in the disease-free survival rates was noted. (C) 2006 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The biocompatibility of commercially pure (cp) titanium stems from its chemical stability within an organism, due to a fine film of impermeable titanium oxide covering the metal surface, which guarantees its resistance to corrosion. Despite its biocompatible characteristic, this material does not promote the formation of a hydroxyapatite layer, therefore, many research groups have sought to alter the material`s surface, introducing modifications that might influence corrosion resistance. The electrochemical behavior of cp Ti, with hydroxyapatite coating and without hydroxyapatite coating, commonly used in implant materials, was investigated using an artificial saliva solution at 25 degrees C and pH=7.4. In the conditions of the study it was observed that the hydroxyapatite layer influences the properties of corrosion resistance. This study of the behavior of cp Ti with and without hydroxyapatite coating, in naturally aerated artificial saliva solution at 25 degrees C, was based on open circuit potential measurements and potentiodynamic polarization curves. At approximately 1x10(-6) A/cm(2) the potential for cp Ti with and without hydroxyapatite coating begins to increase at a faster rate, but at -74mV (SCE) for coated cp Ti and at 180mV (SCE) for uncoated cp Ti the increase in potential begins to slow. This behavior, characterized by a partial stabilization of current density, indicates that in those potential ranges a protective passive film is formed.