152 resultados para laptop performance


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to investigate the ergogenic effects of caffeine on motor performance of judo female athletes. Thirteen female athletes (17.6 +/- 1.6 years, 58.3 +/- 11.4 kg, 162 +/- 4.1 cm, 22.5 +/- 4 kg/m(2)), registered in the State Federation of Judo for at least two years, participated in this study. The motor performance was assessed using the Special Judo Fitness Test (SJFT), from which was considered the number of throws in each block, the total number of throws, recovery and final heart rate (HR) and final score in SJFT. The subjects were tested in two different conditions, after ingestion of gelatin capsules of caffeine (6 mg.kg(-1)) or placebo (dextrose) 60 minutes before testing in a randomized double-blind, crossover study. The number of throws in each block did not differs between the caffeine (CAF) and placebo (PL) conditions (Block A: 4.53 +/- 0.51 CAF and 4.46 +/- 0.51 PL; Block B: 8.3 +/- 0.63 CAF and 8.23 +/- 0.72 PL; Block C: 7.23 +/- 0.59 CAF and 7.46 +/- 0.77 PL), as well as the total number of throws (20.07 +/- 1.18 CAF and 20.15 +/- 1.67 PL), HR (Final: 190.3 +/- 9.63 bpm CAF and 190.69 +/- 9.19 bpm PL; Recovery 162.07 +/- 13.78 bpm CAF and 164.3 +/- 9.64 bpm PL) and final score in SJFT (17.59 +/- 1.4 CAF and 17.75 +/- 1.98 PL). Ingestion of caffeine did not improve performance during high intensity and short duration exercise in judo fighters

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A stability-indicating high-performance liquid chromatographic (HPLC) and a second-order derivative spectrophotometric (UVDS) analytical methods were validated and compared for determination of simvastatin in tablets. The HPLC method was performed with isocratic elution using a C18 column and a mobile phase composed of methanol:acetonitrile:water (60:20:20, v/v/v) at a flow rate of 1.0 ml/min. The detection was made at 239 nm. In UVDS method, methanol and water were used in first dilution and distilled water was used in consecutive dilutions and as background. The second-order derivative signal measurement was taken at 255 nm. Analytical curves showed correlation coefficients > 0.999 for both methods. The quantitation limits (QL) were 2.41 mu g/ml for HPLC and 0.45 mu g/ml for UVDS, respectively. Intra and inter-day relative standard deviations were < 2.0 %. Statistical analysis with t- and F-tests are not exceeding their critical values demonstrating that there is no significant difference between the two methods at 95 % confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High performance liquid chromatographic (HPLC) and UV derivative spectrophotometric (UVDS) methods were developed and validated for the quantitative determination of sotalol hydrochloride in tablets. The HPLC method was performed on a C18 column with fluorescence detection. The excitation and emission wavelengths were 235 and 310nm, respectively. The mobile phase was composed of acetonitrile-water containing 0.1% trietylamine (7:93v/v) and pH adjusted to 4.6 with formic acid. The UVDS method was performed taking a signal at 239.1nm in the first derivative. The correlation coefficients (r) obtained were 0.9998 and 0.9997 for HPLC and UVDS methods, respectively. The proposed methods are simple and adaptable to routine analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to develop and validate analytical methods for determination of amlodipine besylate in tablets. Simple, accurate and precise liquid chromatographic and spectrophotometric methods are proposed. For the chromatographic method, the conditions were: a LiChrospher (R) 100 RP-18 Merck (R) (125 mm x 4.6 mm, 5 mu m) column; methanol/water containing 1 % of trietylamine adjusted to pH 5.0 with phosphoric acid (35:65) as mobile phase; a flow rate of 1.0 mL/min and UV detector at 238 nm. Linearity was in the range of 50.0 - 350.0 mu g/mL with a correlation coefficient (r) = 0.9999. For the spectrophotometric method, the first dilutions of samples were performed in methanol and the consecutives in ultrapure water. The quantitation was made at 364.4 nm. Linearity was determined within the range of 41.0 - 61.0 mu g/mL with a correlation coefficient (r) = 0.9996. Our results demonstrate that both methods can be used in routine analysis for quality control of tablets containing amlodipine besylate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and rapid method, which involves liquid-phase microextraction (LPME) followed by HPLC analysis using Chiralpak AD column and UV detection, was developed for the enantioselective determination of mefloquine in plasma samples. Several factors that influence the efficiency of three-phase LPME were investigated and optimized. Under the optimal extraction conditions, the mean recoveries were 33.2 and 35.0% for (-)-(SR-)-mefloquine and (+)-(RS)-mefloquine, respectively. The method was linear over 50-1500 ng/ml range. Within-day and between-day assay precision and accuracy were below 15% for both enantiomers at concentrations of 150, 600 and 1200 ng/ml. Furthermore, no racemization or degradation were seen with the method described. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for the simultaneous analysis of the enantiomers of mefloquine (MQ) and its main metabolite carboxymefloquine (CMQ) in plasma is described for the first time. The assay involves two-step liquid-phase micro-extraction (LPME) and enantioselective high-performance liquid chromatography. In the first LPME step, the enantiomers of MQ were extracted from an alkalinized sample through a thin layer of di-n-hexyl ether immobilized in the pores of the hollow fiber and into 0.01 M perchloric acid as acceptor solution. In the second LPME step, the same sample was acidified to enable the extraction of CMQ using the same organic solvent and 0.05 M sodium hydroxide as acceptor phase. The analytes were resolved on a Chirobiotic T column in the polar-organic mode of elution and detected at 285 nm. The recovery rates from 1 mL of plasma were in the range 35-38%. The method presented limits of quantification of 50 ng/mL for all analytes and was linear up to 1,500 and 3,000 ng/mL for the enantiomers of MQ and CMQ, respectively. The plasmatic concentrations of (+)-(RS)-MQ were higher than those of (-)-(SR)-MQ after oral administration of the racemic drug to rats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

(+/-)-Licarin A (1), a neolignan obtained by the oxidative coupling reaction of isoeugenol, had in this study its enantiomers resolved. A novel, quick and efficient enantiomeric resolution of 1 was directly performed by chiral high-performance liquid chromatography (HPLC-PDA) protocol (CHIRALPACK (R) AD column; 9:1 (v/v) n-hexane:2-propanol; 1.0 mL/min). This method provided a chromatogram profile with a well-resolved peak separation. After isolation of each enantiomer with ee >99.9%, they were analysed in a polarimeter. Compound 2, which showed a retention time (t(r)) of 12.13 min, was the (+)-enantiomer and compound 3 (t(r) =18.90 min) was the (-)-enantiomer. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method for mercury speciation in hair samples with a fast sample preparation procedure using high-performance liquid chromatography coupled to inductively coupled plasma mass spectrometry is proposed. Prior to analysis, 50 mg of hair samples were accurately weighed into 15 mL conical tubes. Then, an extractant solution containing mercaptoethanol, L-cysteine and HCl was added to the samples following sonication for 10 min. Quantitative mercury extraction was achieved with the proposed procedure. Separation of inorganic mercury (Ino-Hg), methylmercury (Met-Hg) and ethylmercury (Et-Hg) was accomplished in less than 8 min on a C18 reverse phase column with a mobile phase containing 0.05% v/v mercaptoethanol, 0.4% m/v L-cysteine, 0.06 mol L(-1) ammonium acetate and 5% v/v methanol. The method detection limits were found to be 15 ng g(-1), 10 ng g(-1) and 38 ng g(-1), for inorganic mercury, methylmercury and ethylmercury, respectively. Sample throughput is 4 samples h(-1) (duplicate). A considerable improvement in the time of analysis was achieved when compared to other published methods. Method accuracy is traceable to Certified Reference Materials (CRMs) 85 and 86 human hair from the International Atomic Energy Agency (IAEA). Finally, the proposed method was successfully applied to the speciation of mercury in hair samples collected from fish-eating communities of the Brazilian Amazon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tramadol (T) is available as a racemic mixture of (+)-trans-T and (-)-trans-T. The main metabolic pathways are O-demethylation and N-demethylation, producing trans-O-desmethyltramadol (M1) and trans-N-desmethyltramadol (M2) enantiomers, respectively. The analgesic effect of T is related to the opioid activity of (+)-trans-T and (+)-M1 and to the monoaminergic action of (+/-)-trans-T. This is the first study using tandem mass spectrometry as a detection system for the simultaneous analysis of trans-T, M1, and M2 enantiomers. The analytes were resolved on a Chiralpak (R) AD column using hexane: ethanol (95.5:4.5, v/v) plus 0.1% diethylamine as the mobile phase. The quantitation limits were 0.5 ng/ml for trans-T and M1 and 0.1 ng/ml for M2. The method developed and validated here was applied to a pharmacokinetic study in rats. Male Wistar rats (n = 6 at each time point) received a single oral dose of 20 mg/kg racemic trans-T. Blood samples were collected up to 12 h after drug administration. The kinetic disposition of trans-T and M2 was enantioselective (AUC((+)/(-)) ratio = 4.16 and 6.36, respectively). The direction and extent of enantioselectivity in the pharmacokinetics of trans-T and M2 in rats were comparable to data previously reported for healthy volunteers, suggesting that rats are a suitable model for enantioselective studies of trans-T pharmacokinetics. Chirality 23: 287-293, 2011. (C) 2010 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diffusion of Pollution Prevention faces organizational barriers as for instance resistance to change, insufficient support from decision-makers, unclear project leadership, insufficient employee accountability and inflexible organizational structures. To understand how to overcome such barriers, the performance of a Pollution Prevention program of a multinational corporation is analyzed. The quantitative analyses of 2096 Pollution Prevention projects conducted between 1995 and 2007 support the conclusion that the performance of the Pollution Prevention program increased after the implementation of the Six Sigma program. Moreover, the analyses of 1906 Pollution Prevention projects and 31,133 Six Sigma projects for cost reduction in 27 countries indicate that in countries where the implementation of Six Sigma is more expressive, pollution is prevented more than in countries with less expressive Six Sigma implementation. In fact, the Six Sigma implementation improved the organizational capability for data based project management. Therefore, comparing six years before and six years after the Six Sigma implementation, the total number of Pollution Prevention projects recognized increased 6.9 times and the total amount of pollution prevented increased by 62%. The qualitative analysis describes how the Six Sigma program interacts with the Pollution Prevention program in the studied company. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article assesses if innovators outperform non-innovators in Brazilian manufacturing during 1996-2002. To do so, we begin with a simple theoretical model and test the impacts of technological innovation (treatment) on innovating firms (treated) by employing propensity score matching techniques. Correcting for the survivorship bias in the period, it was verified that, on an average, the accomplishment of technological innovations produces positive and significant impacts on the employment, the net revenue, the labor productivity, the capital productivity, and market share of the firms. However, this result was not observed for the mark-up. Especially, the net revenue reflects more robustly the impacts of the innovations. Quantitatively speaking, innovating firms experienced a 10.8-12.5 percentage points (p.p. henceforth) higher growth on employment, a 18.1-21.7 p.p. higher growth on the net revenue, a 10.8-11.9 p.p. higher growth on labor productivity, a 11.8-12.0 p.p. higher growth on capital productivity, and a 19.9-24.3 p.p. higher growth on their market share, relative to the average of the non-innovating firms in the control group. It was also observed that the conjunction of product and process innovations, relative to other forms of innovation, presents the stronger impacts on the performance of Brazilian firms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among marine invertebrates, the overall biomass invested in egg production varies widely within populations, which can result from the interaction of endogenous and exogenous factors. Species that have constant reproduction throughout the year can be good models to study the influence of environmental factors on reproductive processes. We conducted a seasonal comparison of egg production in the intertidal snapping shrimp Alpheus nuttingi, which shows a continuous reproductive pattern, to examine the hypothesis that differences in egg production are driven by environmental conditions and population features. This population showed an uncommon strategy, characterized by females that produce eggs of varying sizes within their clutches, with reduced egg volume when the number of eggs is higher (Spring-Summer). In these seasons, higher temperatures and greater food availability may allow the production of more eggs compared to the Autumn-Winter seasons. Compared to other alpheid shrimps, this population produces small eggs, but in larger numbers. Despite the higher fecundity, the reproductive output is relatively low, this production being supported by the large size of females from the southern Atlantic region. Our findings showed that the egg production of A. nuttingi was greatly influenced by environmental factors. Therefore, this shrimp, and probably other decapods that possess continuous reproduction, adopt different reproductive strategies during the year. (C) Koninklijke Brill NV, Leiden, 2010.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Malnourished rats since birth (mothers fed on 6% of protein) or controlled ones (16% of protein), half of each group received environmental stimulation (ES) from the age of 0-35th day, were studied. The performance in the elevated plus maze (EPM) was assessed on the last day. ES increased time spent and also the entries into open arms of EPM, but malnourished non-stimulated rats visited more segments near the central area than the distant ones. Data suggests an anxiolytic effect of ES which is less evident in malnourished rats. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss the expectation propagation (EP) algorithm for approximate Bayesian inference using a factorizing posterior approximation. For neural network models, we use a central limit theorem argument to make EP tractable when the number of parameters is large. For two types of models, we show that EP can achieve optimal generalization performance when data are drawn from a simple distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The accuracy of multidetector computed tomographic (CT) angiography involving 64 detectors has not been well established. Methods: We conducted a multicenter study to examine the accuracy of 64-row, 0.5-mm multidetector CT angiography as compared with conventional coronary angiography in patients with suspected coronary artery disease. Nine centers enrolled patients who underwent calcium scoring and multidetector CT angiography before conventional coronary angiography. In 291 patients with calcium scores of 600 or less, segments 1.5 mm or more in diameter were analyzed by means of CT and conventional angiography at independent core laboratories. Stenoses of 50% or more were considered obstructive. The area under the receiver-operating-characteristic curve (AUC) was used to evaluate diagnostic accuracy relative to that of conventional angiography and subsequent revascularization status, whereas disease severity was assessed with the use of the modified Duke Coronary Artery Disease Index. Results: A total of 56% of patients had obstructive coronary artery disease. The patient-based diagnostic accuracy of quantitative CT angiography for detecting or ruling out stenoses of 50% or more according to conventional angiography revealed an AUC of 0.93 (95% confidence interval [CI], 0.90 to 0.96), with a sensitivity of 85% (95% CI, 79 to 90), a specificity of 90% (95% CI, 83 to 94), a positive predictive value of 91% (95% CI, 86 to 95), and a negative predictive value of 83% (95% CI, 75 to 89). CT angiography was similar to conventional angiography in its ability to identify patients who subsequently underwent revascularization: the AUC was 0.84 (95% CI, 0.79 to 0.88) for multidetector CT angiography and 0.82 (95% CI, 0.77 to 0.86) for conventional angiography. A per-vessel analysis of 866 vessels yielded an AUC of 0.91 (95% CI, 0.88 to 0.93). Disease severity ascertained by CT and conventional angiography was well correlated (r=0.81; 95% CI, 0.76 to 0.84). Two patients had important reactions to contrast medium after CT angiography. Conclusions: Multidetector CT angiography accurately identifies the presence and severity of obstructive coronary artery disease and subsequent revascularization in symptomatic patients. The negative and positive predictive values indicate that multidetector CT angiography cannot replace conventional coronary angiography at present. (ClinicalTrials.gov number, NCT00738218.).