109 resultados para implant fracture
Resumo:
Background: This study evaluated the effects of diclofenac sodium and meloxicam on peri-implant bone healing. Methods: Thirty male rats were divided into three groups: the control group (CG) received no drug; the diclofenac sodium group (DSG) received 1.07 mg/kg twice a day for 5 days; and the meloxicam group (MG) received 0.2 mg/kg daily for 5 days. A screw-shaped titanium implant was placed in the tibia. Fluorochromes, oxytetracycline (OxT), calcein (CA), and alizarin (AL), were injected at 7, 14, and 21 days, respectively, after implantation, and the animals were sacrificed 28 days after implant placement. The percentages of OxT-, CA-, and AL-labeled bone as well as the percentages of bone-to-implant contact (BIC), cortical bone area (CBA), and trabecular bone area (TBA) within the implant threads were evaluated. Results: Bone healing was delayed in the DSG during the first 14 days after implant placement (OxT-labeled bone: DSG: 5.3% +/- 7.3% versus CG: 13.2% +/- 9.8%, P= 0.002, and versus MG: 14.4% +/- 13.1%, P = 0.05). The percentages of BIC (DSG: 49.6% +/- 21.9%; MG: 67.1% +/- 22.8%; and CG: 68.1% +/- 22.8%) and CBA (DSG: 63.7% +/- 21.2%; MG: 82.7% +/- 12.4%; CG: 84.9% +/- 10.6%) were lower in the DSG compared to the MG and CG (P<0.001). The percentage of TBA was significantly greater in the DSG compared to the MG and CG (DSG: 36.3% +/- 21.2% versus MG: 17.3% +/- 12.7% and versus CG: 15.1% +/- 10.6%; P<0.001). Conclusion: Diclofenac sodium seemed to delay peri-implant bone healing and to decrease BIC, whereas meloxicam had no negative effect on peri-implant bone healing.
Resumo:
Systemic inflammation after augmentation mammaplasty with modern silicone implants is not currently recognized. In a prospective controlled study, C-reactive protein and other variables were monitored, aiming to test this hypothesis in a young cohort of patients. Females (18-30 years old, BMI = 18.5-30 kg/m(2), N = 52) were consecutively recruited for breast implant (n = 24, Group I) and for abdominal liposuction (n = 28, Group II/Controls). Patients were interviewed at baseline and followed until 6 months after operation. Variables included demographic and clinical information, surgical outcome, inflammatory markers and autoantibodies. Operations were well tolerated, without surgical or infectious complications. Mean prosthesis size was 258 +/- A 21 ml (range = 220-280) and mean aspirate of liposuction was 1972 +/- A 499 ml (range = 1200-3000). Preoperative, 2-month, and 6-month C-reactive protein concentrations for breast implant patients were 1.3 +/- A 1.2, 4.8 +/- A 3.0, and 4.3 +/- A 6.4 mg/l and for liposuction 3.5 +/- A 2.7, 3.5 +/- A 2.1, and 2.2 +/- A 2.2 mg/l, respectively. Change at 2 months was significant (p = 0.001). Autoantibody investigation failed to reveal remarkable aberrations, except for anticardiolipin elevation, which was nearly symmetrical in the two groups. C-reactive protein levels increased after operation and correlated with proinflammatory and procoagulatory indices. A mild increase in anticardiolipin IgM occurred but differences between populations were lacking. Despite excellent cosmetic outcomes and lack of complications, acute phase reaction could signal ongoing immunogenicity of silicone and long-term monitoring is recommended.
Resumo:
Silicon nitride has demonstrated to be a potential candidate for clinical applications because it is a non-cytotoxic material and has satisfactory fracture toughness, high wear resistance and low friction coefficient. In this paper, samples of silicon nitride, which were kept into rabbits` tibias for 8 weeks, and the adjacentbone tissue were analysed by scanning electron microscopy in order to verify the bone growth around the implants and the interaction between the implant and the bone. Bone growth occurred mainly in the cortical areas, although it has been observed that the newly bone tends to grow toward the marrow cavity. Differences were observed between the implants installed into distal and proximal regions. In the first region, where the distance between the implant and the cortical bone is greater than in the proximal region, the osteoconduction process was evidenced by the presence of a bridge bone formation toward the implant surface. The results showed that silicon nitride can be used as biomaterial since the newly bone grew around the implants. (c) 2007 Elsevier Inc. All rights reserved.
Resumo:
The chemical and dimensional stability associated with suitable fracture toughness and propitious tribological characteristics make silicon nitride-based ceramics potential candidates for biomedical applications, mainly as orthopedic implants. Considering this combination of properties, silicon nitride components were investigated in relation to their biocompatibility. For this study, two cylindrical implants were installed in each tibia of five rabbits and were kept in the animals for 8 weeks. During the healing time, tissue tracers were administrated in the animals so as to evaluate the bone growth around the implants. Eight weeks after the surgery, the animals were euthanized and histological analyses were performed. No adverse reactions were observed close to the implant. The osteogenesis process occurred during the entire period defined by the tracers. However, this process occurred more intensely 4 weeks after the surgery. In addition, the histological analyses showed that bone growth occurred preferentially in the cortical areas. Different kinds of tissue were identified on the implant surface, characterized by lamellar bone tissue containing osteocytes and osteons, by a noncalcified matrix containing osteoblasts, or by the presence of collagen III, which may change to collagen I or remain as a fibrous tissue. The results demonstrated that silicon nitride obtained according to the procedure proposed in this research is a biocompatible material. (c) 2007 Wiley Periodicals, Inc.