131 resultados para Measurement scale
Resumo:
To validate the Brazilian version of the Brief Pain Inventory (BPI-B) scale and to determine the optimal cutpoints for mild, moderate, and severe pain based on patients` rating of their worst pain. One hundred forty-three outpatients with cancer were recruited in Hospital das Clinicas-University of Sao Paulo, Brazil. Confirmatory factor analysis confirmed two underlying dimensions, pain severity, and pain interference, with Cronbach`s alpha of 0.91 and 0.87, respectively. Convergent validity was shown by the correlation observed between the BPI dimensions with the EORTC-QLQ-C30 pain scale and the McGill Pain Questionnaire. The BPI-B detected significant differences in the two dimensions by disease and performance status, supporting known-group validity. For the worst pain, the optimal cutpoints were 4 and 7 (1-4 = mild pain, 5-7 = moderate, and 8-10 = severe). Our data show that BPI-B is a brief, useful, and valid tool for assessing pain and its impact on patient`s life.
Resumo:
Purpose. To use 3-dimensional sonography (3DUS) to measure contralateral lung volume and evaluate the potential of this measurement to predict neonatal outcome in isolated congenital diaphragmatic hernia (CDH). Methods. Between January 2002 and December 2004, the contralateral lung volumes of 39 fetuses with isolated CDH were measured via 3DUS using rotational multiplanar imaging. The observed/expected contralateral fetal lung volume ratios (o/eContFLVR) were compared with the lung/head ratio (LHR), observed/expected total fetal lung volume ratio (o/e-TotFLVR), and postnatal outcome. Results. Contralateral lung volumes are less reduced than total lung volumes in CDH. The bias and precision of 3DUS in estimating contralateral lung volumes were 0.99 cm(3) and 1.11 cm(3), respectively, with absolute limits of agreement ranging from -1.19 cm(3) to + 3.17 cm(3). The o/e-ContFLVR was significantly lower in neonatal death cases (median, 0.49 cm(3); range, 0.22-0.99 cm(3)) than in survival cases (median, 0.58 cm(3); range, 0.42-0.92 cm(3) [p < 0.011). Overall accuracy of the o/e-ContFLVR, o/e-TotFLVR, and LHR in predicting neonatal death were 67.7% (21/31), 80.7% (25/31), and 77.4% (24/31), respectively. Conclusion. Although o/e-ContFLVR can be precisely measured with 3DUS and can be used to predict neonatal death in CDH, it is less accurate than LHR and o/e-TotFLVR for that purpose. (C) 2007 Wiley Periodicals, Inc.
Resumo:
The magnitude Of functional impairment that may indicate the threshold between MCI and incipient Alzheimer`s disease (AD) has not been clearly defined. The objective was to examine the pattern of functional impairment in the continuum MCI-AD. Eighty-nine older adults (32 cognitively unimpaired, 31 MCI, and 26 AD patients) were examined with the Brazilian version of the Direct Assessment of Functional Status (DAFS-BR) at a University-based memory clinic. MCI patients were sub-divided according to the progression to AD upon follow-up, and had baseline cognitive, functional and biological variables analyzed. MCI patients displayed mild deficits in functional abilities, with intermediate scores as compared to controls and AD. The DAFS-BR items that differentiated MCI from controls involved the ability to deal with finances and shopping skills. At baseline, scores obtained by MCI patients who converted to AD were not significantly different from scores of nonconverters. The magnitude of functional deficits was associated with AD-like pathological findings in the CSF. In conclusion, MCI patients present with early functional changes in complex, instrumental abilities that require the integrity of memory and executive functions. The objective measurement of the functional state may help identify older adults with increased risk of developing dementia in the MCI-AD continuum. (JINS, 2010, 16, 297-305.)
Resumo:
Objective: To assess the serum levels of interleukin 1 beta (IL-1 beta) in elderly depressed patients in comparison with nondepressed healthy elderly subjects. Design: Cross-sectional study. Setting: Tertiary memory clinic. Participants: Twenty-three antidepressant-free elderly depressed patients and 44 nondepressed healthy elderly comparison group were enrolled to this study. Measurement: Serum IL-1 beta levels were determined with highly sensitive colorimetric sandwich enzyme-linked immunosorbent assay. Severity of the depressive episode was determined by scores on the Hamilton Depression Scale-21 item and cognitive performance by the scores on the Cambridge Cognition Examination, Mini Mental State Examination clock drawing test, and verbal fluency. Results: IL-1 beta serum levels were increased in elderly patients versus nondepressed elderly (t = 2.21, df = 65, p = 0.04). After categorizing elderly depressed subjects into late onset (LOD) versus early onset (EOD), patients with EOD had the highest IL-1 beta levels, when compared with nondepressed elderly patients and patients with LOD in analysis of variance (F = 4.9, df = 2, 64, p < 0.01). Conclusions: Late-life depression is associated with higher IL-1 beta levels suggesting that increased proinflammatory state may play a role in the physiopathology of depression in the elderly. The authors further show that this might be more prominent in those patients with EOD geriatric depression. (Am J Geriatr Psychiatry 2010; 18: 172-176)
Resumo:
Introduction: Although obsessions and compulsions comprise the main features of obsessive-compulsive disorder (OCD), many patients report that their compulsions are preceded by a sense of ""incompleteness"" or other unpleasant feelings such as premonitory urges or a need perform action`s until feeling ""just right."" These manifestations have been characterized as Sensory Phenomena (SP). The current study presents initial psychometric data for a new scale designed to measure SP. Methods: Seventy-six adult OCD subjects were probed twice. Patients were assessed with an open clinical interview (considered as the ""gold standard"") and with the following standardized instruments: Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition Axis I Disorders, Yale-Brown Obsessive-Compulsive Scale, Dimensional Yale-Brown Obsessive-Compulsive Scale, Yale Global Tic Severity Scale, Beck Anxiety Inventory, and Beck Depression Inventory. Results: SP were present in 51 OCD patients (67.1%). Tics were present in 16 (21.1%) of the overall sample. The presence of SP was significantly higher in early-onset OCD patients. There were no significant differences in the presence of SP according to comorbidity with tics or gender. The comparison between the results from the open clinical interviews and the University of Sao Paulo Sensory Phenomena Scale (USP-SPS) showed an excellent concordance between them, with no significant differences between interviewers. The inter-rater reliability between the expert raters for the USP-SPS was high, with K=.92. The Pearson correlation coefficient between the SP severity scores given by the two raters was .89. Conclusion: Preliminary results suggest that the USP-SPS is a valid and reliable instrument for assessing the presence and severity of SP in OCD subjects. CNS Spectr. 2009;14(6):315-323
Resumo:
Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a (192)Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the (192)Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the 192Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0 +/- 1.0 and 17.3 +/- 1:2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of vertical bar a vertical bar = 113 cm/s(2). In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors` knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3483780]
Resumo:
Data are reported on the background and performance of the K6 screening scale for serious mental illness (SMI) in the World Health Organization (WHO) World Mental Health (WMH) surveys. The K6 is a six-item scale developed to provide a brief valid screen for Diagnostic and Statistical Manual of Mental Disorders 4th edition (DSM-IV) SMI based on the criteria in the US ADAMHA Reorganization Act. Although methodological studies have documented good K6 validity in a number of countries, optimal scoring rules have never been proposed. Such rules are presented here based on analysis of K6 data in nationally or regionally representative WMH surveys in 14 countries (combined N = 41,770 respondents). Twelve-month prevalence of DSM-IV SMI was assessed with the fully-structured WHO Composite International Diagnostic Interview. Nested logistic regression analysis was used to generate estimates of the predicted probability of SMI for each respondent from K6 scores, taking into consideration the possibility of variable concordance as a function of respondent age, gender, education, and country. Concordance, assessed by calculating the area under the receiver operating characteristic curve, was generally substantial (median 0.83; range 0.76-0.89; inter-quartile range 0.81-0.85). Based on this result, optimal scaling rules are presented for use by investigators working with the K6 scale in the countries studied. Copyright (c) 2010 John Wiley & Sons, Ltd.
Resumo:
The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The dorsolateral prefrontal cortex (DLPFC) has been implicated in the pathophysiology of mental disorders. Previous region-of-interest MRI studies that attempted to delineate this region adopted various landmarks and measurement techniques, with inconsistent results. We developed a new region-of-interest measurement method to obtain morphometric data of this region from structural MRI scans, taking into account knowledge from cytoarchitectonic postmortem studies and the large inter-individual variability of this region. MRI scans of 10 subjects were obtained, and DLPFC tracing was performed in the coronal plane by two independent raters using the semi-automated software Brains2. The intra-class correlation coefficients between two independent raters were 0.94 for the left DLPFC and 0.93 for the right DLPFC. The mean +/- S.D. DLPFC volumes were 9.23 +/- 2.35 ml for the left hemisphere and 8.20 +/- 2.08 ml for the right hemisphere. Our proposed method has high inter-rater reliability and is easy to implement, permitting the standardized measurement of this region for clinical research applications. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Objective: To compare the performance of patients with obsessive-compulsive disorder (OCD) refractory to conventional treatments to healthy controls according to the Frontal Systems Behaviour Scale (FrSBe), comparing the scale scores within each group (Self or Family) and correlating FrSBe with Y-BOCS, DY-BOCS, tic disorder and age of first symptoms. Method: Twenty OCD patients and 20 healthy controls were assessed using the FrSBe, a scale designed to evaluate frontal syndromes. Results: The patients had higher scores when compared with the control group (p value .001) in terms of total score on the scale for both profile forms (Self and Family). In addition, there was a significant difference between the scores reported by the patients and their respective relatives. However, no correlation was observed between the scale and the other variables. Conclusions: The scale was able to clearly differentiate patients with OCD from healthy controls. This finding suggests that the FrSBe can be used not only in neurologic patients but also in psychiatric cases such as refractory OCD.
Resumo:
Background: Pain and anxiety are a common problem in all recovery phases after a burn. The Burns Specific Pain Anxiety Scale (BSPAS) was proposed to assess anxiety in burn patients related to painful procedures. Objectives: To assess internal consistency, discriminative construct validity, dimensionality and convergent construct validity of the Brazilian-Portuguese version of the Burns Specific Pain Anxiety Scale. Design: In this cross-sectional study, the original version of the BSPAS, adapted into Brazilian Portuguese, was tested for internal consistency (Cronbach`s Alpha), discriminative validity (related to total body surface area burned and sex), dimensionality (through factor analysis), and convergent construct validity (applying the Visual Analogue Scale for pain and State-Anxiety-STAI) in a group of 91 adult burn patients. Results: The adapted version of the BSPAS displayed a moderate and positive correlation with pain assessments: immediately before baths and dressings (r = 0.32; p < 0.001), immediately after baths and dressings (r = 0.31; p < 0.001) and during the relaxation period (r= 0.31; p < 0.001) and with anxiety assessments (r = 0.34; p < 0.001). No statistically significant differences were observed when comparing the mean of the adapted version of the BSPAS scores with sex (p = 0.194) and total body surface area burned (p = 0.162) (discriminative validity). The principal components analysis applied to our sample seems to confirm anxiety as one single domain of the Brazilian-Portuguese version of the BSPAS. Cronbach`s Alpha showed high internal consistency of the adapted version of the scale (0.90). Conclusion: The Brazilian-Portuguese version of the BSPAS 9-items has shown statically acceptable levels of reliability and validity for pain-related anxiety evaluation in burn patients. This scale can be used to assess nursing interventions aimed at decreasing pain and anxiety related to the performance of painful procedures. (c) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Background: Shrimp is a frequent cause of food allergy. Tropomyosin is the major allergen in shrimp, and it shares homology to tropomyosins from other crustaceans, dust mites, cockroach, and parasites. Objective: The aim of this study was to determine the value of detection of IgE to shrimp tropomyosin in the diagnosis of shrimp allergy. Methods: We have studied 35 patients with asthma, rhinitis, or both who were sensitized to Dermatophagoides pteronyssinus. All subjects underwent skin prick testing in addition to double-blind, placebo-controlled food challenges (DBPCFC); oral open challenges; or both with shrimp. Measurements of IgE to shrimp and shrimp tropomyosin were carried out by means of CAP and chimeric ELISA, respectively. Results: Oral challenges confirmed the diagnosis of shrimp allergy in 7 patients. IgE measurement to shrimp tropomyosin was positive in 71.4% of the patients with shrimp allergy. Of the 28 patients without shrimp allergy, only 7.1% (2/28) had IgE to shrimp tropomyosin compared with 25% (7/28) who had IgE to shrimp and 35.7% (10/28) who had positive skin prick test responses to shrimp. Sensitivity was similar for all 3 methods (71.4%); in contrast, specificity of IgE to shrimp tropomyosin (92.8%) was greater than that of IgE to shrimp (75%) and skin prick testing (64.2%). With regard to diagnostic efficiency, measurement of IgE to shrimp tropomyosin was superior to measurement of IgE to shrimp and skin prick testing (88.5%, 74.2%, and 65.7%, respectively). Conclusion: Use of measurements of IgE to shrimp tropomyosin provided added value to the diagnosis of shrimp allergy. (J Allergy Clin Immunol 2010;125:872-8.)
Resumo:
Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
Social anxiety disorder (SAD) is a highly prevalent condition even though its recognition and diagnosis are underestimated by both patients and clinicians. In view of the importance of assessment scales for systematic diagnosis in psychiatry, the objective of this investigation was to present studies of validation for the Brazilian population of three instruments for the assessment of different aspects of SAD. The following psychometric studies were carried out: a) discriminative validity of the Mini Social Phobia Inventory (Mini-SPIN-MS), a reduced instrument for the screening of SAD; b) reliability and discriminative validity of the Brief Social Phobia Scale (BSPS), a hetero-applied instrument for the assessment of different aspects of SAD, and c) discriminative validity of the items and subscales of the Self-Statements during Public Speaking Scale (SSPS), an instrument for the assessment of cognitive aspects related to public speaking. All instruments showed excellent psychometric qualities, especially indicators of discrimination between persons with and without SAD, with diagnostic confirmation by the Structured Clinical Interview for DSM-IV (SCID-IV). It was concluded that this set of instruments, with specificity regarding their objectives, could be of great clinical usefulness, especially for the Brazilian population that, until recently, had no such resources for the measurement and assessment of the different aspects of SAD. New multicenter and intercultural studies may provide further information about cultural influences on SAD.
Resumo:
The aim of this study was to create an adaptation of the Revised Knox Preschool Play Scale (RKPPS) for the Brazilian population, as well as to apply the instrument with statistical analysis to verify the preliminary intra-rater and inter-rater reliability and repeatability of the instrument. The instructions presented by Beaton et al. regarding adaptation of instruments were followed to perform a cross-cultural adaptation of the RKPPS. A preliminary test of the Portuguese version was performed on 18 children with no motor, cognitive or sensory impairment. The video recordings of this administration were analysed on two separate occasions by two examiners within a 5-month interval, using the scores suggested by Pfeifer. The Spearman`s test was used in the statistical analysis of the obtained data. The author of the RKPPS agreed with the small necessary cultural adaptations. The Spearman test revealed a high correlation coefficient and good significance levels for both intra- and inter-raters values. This study demonstrated the reliability and repeatability of the Brazilian version of the RKPPS. This is a preliminary study and further studies are needed in order to validate the scale to be administered in the Brazilian population. Copyright (C) 2010 John Wiley & Sons, Ltd.