112 resultados para Calibration plot


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson`s correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To investigate clinical and MRI findings that are predictive of both visual loss in patients with pituitary adenomas and visual recovery after treatment. Design: Cohort study. Participants: Thirty patients (60 eyes) with pituitary adenoma. Methods: Patients underwent neuro-ophthalmic examination and MRI before and after optic chiasm decompression. Visual field (VF) was assessed using the mean deviation in standard automated perimetry (SAP) and temporal mean defect, the average of 22 temporal values of the total deviation plot. Tumour size was measured on sagittal and coronal cuts. Results: Visual loss was found in 47 eyes; 35 had optic atrophy (subtle in 9, moderate in 14, and severe in 12). Before treatment, the average SAP mean deviation and temporal mean defect were -11.78 (SD 8.56) dB and -18.66 (SD 11.20) dB, respectively. The chiasm was 17.3 (SD 6.2, range 10-34) mm above the reference line on the sagittal and 21.8 (SD 8.3, range 12-39) mm on the coronal images. Tumour size correlated with the severity of VF defect. VF improvement occurred in 80% of eyes after treatment. The degree of optic atrophy, visual loss, and tumour size were significantly associated with improvement after treatment. Conclusions: The best predictive factor for visual loss was tumour size, and factors related to visual recovery were the degree of optic atrophy, the severity of VF defect, and the tumour size. Diagnosing pituitary adenomas before optic atrophy becomes severe may be related to a better prognosis in such patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Understanding the mating patterns of populations of tree species is a key component of ex situ genetic conservation. In this study, we analysed the genetic diversity, spatial genetic structure (SGS) and mating system at the hierarchical levels of fruits and individuals as well as pollen dispersal patterns in a continuous population of Theobroma cacao in Para State, Brazil. A total of 156 individuals in a 0.56 ha plot were mapped and genotyped for nine microsatellite loci. For the mating system analyses, 50 seeds were collected from nine seed trees by sampling five fruits per tree (10 seeds per fruit). Among the 156 individuals, 127 had unique multilocus genotypes, and the remaining were clones. The population was spatially aggregated; it demonstrated a significant SGS up to 15m that could be attributed primarily to the presence of clones. However, the short seed dispersal distance also contributed to this pattern. Population matings occurred mainly via outcrossing, but selfing was observed in some seed trees, which indicated the presence of individual variation for self-incompatibility. The matings were also correlated, especially within ((r) over cap (p(m)) = 0.607) rather than among the fruits ((r) over cap (p(m)) = 0.099), which suggested that a small number of pollen donors fertilised each fruit. The paternity analysis suggested a high proportion of pollen migration (61.3%), although within the plot, most of the pollen dispersal encompassed short distances (28m). The determination of these novel parameters provides the fundamental information required to establish long-term ex situ conservation strategies for this important tropical species. Heredity (2011) 106, 973-985; doi:10.1038/hdy.2010.145; published online 8 December 2010

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: A new adjustable pinch has been developed for producing a crush injury, with a previously known load of 5 kg, on a 5 mm-long segment of the nerve. Methods: Stainless steel was the material selected for building the pinch due its durability and possibility of sterilization with anti-septic substances, which are often corrosive. The crushing load of the pinch is adjustable by increasing or decreasing the tension of the spring by means of a screw used for calibration, which is performed by a load cell. Result: This pinch has been used in a few experimental investigations and was shown to be as efficient as both the universal testing machine and the dead weight machine, previously used. Conclusion: The developed pinch has the advantages of being portable and user-friendly. In addition, the pinch is cheap and allows for the standardization of the applied load.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: This study aimed to assess the relative validity of a food frequency questionnaire.(FFQ), previously validated to measure usual intakes in adults, for measuring dietary intakes in children 5 to 10 y of age. Methods: Dietary intakes were measured using an FFQ and a 3-d dietary record. Healthy children, 5 to 10 y old (n = 151), were recruited from public schools and asked to answer the questions in the FFQ and to provide non-consecutive 3-d dietary records based on reported estimated portion sizes. Paired sample t tests and Pearson`s correlation coefficients were conducted to determine whether the two instruments reported similar values for energy and nutrients. The agreement of quartile categorization between the two instruments was also examined. Results: Estimated energy and nutrient intakes derived from the FFQ were significantly higher than those derived from 3-d dietary records. As expected, Pearson`s correlations increased after adjusting for residual measurement error, presumably due to exclusion of the high within-person variability in intake of these nutrients. Moderate to high (r > 0.50) correlation coefficients were verified for some nutrients such as calcium, folate, vitamin 132, vitamin A, and vitamin C. Conclusion: This FFQ, originally developed for use in adults, appears to overestimate usual energy and nutrient intakes in children 5 to 10 y of age. Further work is necessary to conduct a calibration study to establish adequate portion sizes before instrument adoption in this population. (c) 2008 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. This study investigated the prevalence of dental wear in 12-year-old adolescents using a modification of the tooth wear index (TWI). The modifications were proposed in order to fit with the World Health Organization standard, thus allowing application of the index in broad epidemiological surveys. Study design: An epidemiological cross-sectional survey was performed by trained, calibrated examiners, using a modified version of the TWI. Methods: Urban elementary schools were chosen because they provide a fair representation of the city`s population in terms of socio-economic status. The sample included 295 adolescents, selected randomly and systematically. Dental wear was assessed by calibrated examiners (kappa > 0.85), using a modified version of the TWI. This modified version includes a code for teeth restored due to wear, and another code for teeth that cannot be assessed. In addition, it does not differentiate the depth of dentine involvement. Proportions and confidence intervals were used to describe the prevalence of dental wear. Mann-Whitney test was used to detect differences in the degree of dental wear between mates and females. The level of statistical significance was set at 5%. Results: In total, 24,780 dental surfaces were evaluated. Among these surfaces, 73.10% did not present dental wear, 24.10% had incipient lesions, 2.46% had moderate lesions and 0.34% had been restored. No severe lesions were detected. Tooth wear was mainly seen on the occlusal/incisal surfaces (26.55%), involving enamel or enamel-dentine, but not the secondary dentine or pulp. The prevalence of dental wear was 26.90%. Considering the different teeth, wear was present in 53.22% of incisors, 50.51% of canines, 10.17% of premolars and 10.85% of molars. The prevalence of the different degrees of dental wear was similar in mates and females (P > 0.05). Conclusion: The modified TWI seems to bean effective toot for use in broad epidemiological surveys, due to easier calibration and high reproducibility rates. (C) 2008 The Royal Institute of Public Health. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the effect of core-design modification on the characteristic strength and failure modes of glass-infiltrated alumina (In-Ceram) (ICA) compared with porcelain fused to metal (PFM). Premolar crowns of a standard design (PFMs and ICAs) or with a modified framework design (PFMm and ICAm) were fabricated, cemented on dies, and loaded until failure. The crowns were loaded at 0.5 mm min(-1) using a 6.25 mm tungsten-carbide ball at the central fossa. Fracture load values were recorded and fracture analysis of representative samples were evaluated using scanning electron microscopy. Probability Weibull curves with two-sided 90% confidence limits were calculated for each group and a contour plot of the characteristic strength was obtained. Design modification showed an increase in the characteristic strength of the PFMm and ICAm groups, with PFM groups showing higher characteristic strength than ICA groups. The PFMm group showed the highest characteristic strength among all groups. Fracture modes of PFMs and of PFMm frequently reached the core interface at the lingual cusp, whereas ICA exhibited bulk fracture through the alumina core. Core-design modification significantly improved the characteristic strength for PFM and for ICA. The PFM groups demonstrated higher characteristic strength than both ICA groups combined.