121 resultados para Absorption Measurements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Although inflammation has a defined role in the pathogenesis of atherosclerosis, the link between rheumatoid arthritis (RA) parameters of disease activity and atherosclerotic findings are not defined. Objective: To investigate the association between subclinical carotid atherosclerosis and clinical/laboratorial parameters of RA systemic inflammatory activity. Methods: Seventy-one RA patients were consecutively selected and compared to 53 healthy controls. Smoking, diabetes and hypertension were excluded, as well as the use of statins or fibrates. B-mode carotid ultrasound was performed in all subjects. CRP, ESR and fibrinogen were determined in both groups. Clinical assessment of RA activity included DAS 28 and SDAI. Correlation between plaques and intima-media thickness (IMT) of common carotid arteries and inflammatory parameters was evaluated. Results: Carotid plaques were more prevalent in RA patients than in controls (14.1% vs. 1.9 %, p=0.02) and marginally increased IMT was observed (0.72 +/- 0.17 vs. 0.67 +/- 0.15mm, p=0.07). RA patients with plaques had older age (p=0.001) and increased IMT (p<0.001), but low SDAI (p=0.025) compared to those without plaques. RA patients with plaques had also longer disease duration, although this difference did not reach statistical significance (p=0.06). No significant correlations were found between IMT and ESR (p=0.80), CRP (p=0.75), fibrinogen (p=0.94), HAQ (p=0.89) and DAS 28 (p=0.13). Conclusions: Carotid atherosclerosis is more frequently detected in RA but its prevalence was not correlated with isolated inflammatory markers measurement or noncumulative activity scores. These findings reinforce the need to evaluate subclinical atherosclerosis in RA patients, and to find predictors of atherosclerotic lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The antiatherogenic functions of high density lipoprotein (HDL-C) include its role in reverse cholesterol transport, but to what extent the concentration of HDL-C interferes with the whole-body cholesterol metabolism is unknown. Therefore, we measured markers of body cholesterol synthesis (desmosterol and lathosterol) and of intestinal cholesterol absorption (campesterol and beta-sitosterol) in healthy subjects that differ according to their plasma HDL-C concentrations. Methods: Healthy participants presented either low HDL-C (<40 mg/dl, n = 33,17 male and 16 female) or high HDL-C (>60 mg/dl, n = 33, 17 male and 16 female), BMI <30 kg/m(2), were paired according to age and gender, without secondary factors that might interfere with their plasma lipid concentrations. Plasma concentrations of non-cholesterol sterols were measured by the combined GC-MS analysis. Results: Plasma desmosterol did not differ between the two groups; however, as compared with the high HDL-C participants, the low HDL-C participants presented higher concentration of lathosterol and lower concentration of the intestinal cholesterol absorption markers campesterol and beta-sitosterol. Conclusion: Plasma concentrations of HDL, and not the activities of LCAT and CETP that regulate the reverse cholesterol transport system, correlate with plasma sterol markers of intestinal cholesterol absorption directly, and of cholesterol synthesis reciprocally. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here, we examine morphological changes in cortical thickness of patients with Alzheimer`s disease (AD) using image analysis algorithms for brain structure segmentation and study automatic classification of AD patients using cortical and volumetric data. Cortical thickness of AD patients (n = 14) was measured using MRI cortical surface-based analysis and compared with healthy subjects (n = 20). Data was analyzed using an automated algorithm for tissue segmentation and classification. A Support Vector Machine (SVM) was applied over the volumetric measurements of subcortical and cortical structures to separate AD patients from controls. The group analysis showed cortical thickness reduction in the superior temporal lobe, parahippocampal gyrus, and enthorhinal cortex in both hemispheres. We also found cortical thinning in the isthmus of cingulate gyrus and middle temporal gyrus at the right hemisphere, as well as a reduction of the cortical mantle in areas previously shown to be associated with AD. We also confirmed that automatic classification algorithms (SVM) could be helpful to distinguish AD patients from healthy controls. Moreover, the same areas implicated in the pathogenesis of AD were the main parameters driving the classification algorithm. While the patient sample used in this study was relatively small, we expect that using a database of regional volumes derived from MRI scans of a large number of subjects will increase the SVM power of AD patient identification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three patients with progressive visual loss, chronic alcoholism and tabagism were submitted to a complete neuro-ophthalmic examination and to retinal nerve fiber layer (RNFL) measurements using optical coherence tomography (OCT) scanning. Two patients showed marked RNFL loss in the temporal sector of the optic disc. However, a third patient presented RNFL measurements within or above normal limits, based on the Stratus-OCT normative database. Such findings may be due to possible RNFL edema similar to the one that may occur in the acute phase of toxic optic neuropathies. Stratus-OCT was able to detect RNFL loss in the papillomacular bundle of patients with tobacco-alcohol-induced toxic optic neuropathy. However, interpretation must be careful when OCT does not show abnormality in order to prevent diagnostic confusion, since overestimation of RNFL thickness measurements is possible in such cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arterial stiffness is an independent marker of cardiovascular events. Pulse wave velocity (PWV) is a validated method to detect arterial stiffness that can be influenced by several factors including age and blood pressure. However, it is not clear whether PWV could be influenced by circadian variations. In the present study, the authors measured blood pressure and carotid-femoral PWV measurements in 15 young healthy volunteers in 4 distinct periods: 8 am, noon, 4 pm, and 8 pm. No significant variations of systolic (P=.92), mean (P=.77), and diastolic (P=.66) blood pressure among 8 am (113 +/- 15, 84 +/- 8, 69 +/- 6 mm Hg), noon (114 +/- 13, 83 +/- 8, 68 +/- 6 mm Hg), 4 pm (114 +/- 13, 85 +/- 8, 70 +/- 7 mm Hg), and 8 pm (113 +/- 7, 83 +/- 10, 68 +/- 7 mm Hg), respectively, were observed. Similarly, carotid-femoral PWV did not change among the periods (8 am: 7.6 +/- 1.4 m/s, noon: 7.4 +/- 1.1 m/s, 4 pm: 7.6 +/- 1.0 m/s, 8 pm, 7.6 +/- 1.3 m/s; P=.85). Considering all measurements, mean blood pressure significantly correlated with PWV (r=.31; P=.016). In young healthy volunteers, there is no significant circadian variation of carotid-femoral PWV. These findings support the concept that it does not appear mandatory to perform PWV measurements at exactly the same period of the day. J Clin Hypertens (Greenwich). 2011;13:19-22. (c) 2010 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To determine if knee alignment measures differ between African Americans and Caucasians without radiographic knee osteoarthritis (rOA). Methods. A single knee was randomly selected from 175 participants in the Johnston County Osteoarthritis Project without rOA in either knee. Anatomic axis, condylar, tibia] plateau, and condylar plateau angles were measured by I radiologist; means were compared and adjusted for age and body mass index (BMI). Results. There were no significant differences in knee alignment measurements between Caucasians and African Americans among men or women. Conclusion. Observed differences in knee rOA occurrence between African Americans and Caucasians are not explained by differences in static knee alignment. (First Release July 15 2009; J Rheumatol 2009;36:1987-90; doi: 10.3899/jrheum.081294)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper is to study the correlation between the intraocular pressure peaks and fluctuation detected during the water drinking test and the same parameters observed during long-term follow up. This prospective cohort study enrolled 22 eyes of 22 newly diagnosed primary open angle glaucoma patients. After an initial complete ophthalmological examination, patients were started on antiglaucoma medication and returned 4 weeks later to perform the water drinking test. Thereafter, patients were evaluated at least eight times within a period of 6-12 months. The intraocular pressure peaks and fluctuation detected during the water drinking stress test were compared with those observed during regular office visits. Spearman`s correlation coefficient and Bland-Altman Plots were used for statistical analysis. The mean age of participants was 54.3 +/- 8.2 years (+/- SD), 59% were women, and average mean deviation -10.2 +/- 4.5 dB. The mean follow-up period was 8.2 +/- 2.0 months. The average intraocular pressure peaks and fluctuation during the water drinking test were 20.0 +/- 2.9 mmHg and 40 +/- 10%, respectively, and 18.1 +/- 2.8 mmHg and 30 +/- 10% during follow up. Spearman`s correlation coefficients were significant and strong between the intraocular pressure peaks and fluctuation detected during the water drinking test and during the follow-up period (P < 0.001, rho = 0.76 and 0.82, respectively). There was good agreement between the variables. The intraocular pressure peaks and fluctuation detected during the water drinking test showed significant correlation and agreement with the pressures observed during follow-up visits. Stress tests could be used to estimate long-term intraocular pressure variation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To build nomograms of fetal thyroid circumference (FTC), fetal thyroid area (FTA), and fetal thyroid transverse diameter (FTTD) throughout gestational age (GA). Method. Between January 2006 and July 2006, FTC, FTA, and FTTD were measured once in 196 normal fetuses examined at a GA of 22-35 weeks. Inclusion criteria were a healthy mother with normal maternal thyrotropin level during pregnancy, a singleton pregnancy with normal fetal morphology on sonography, and GA confirmed via first-trimester sonographic examination. Results. Mean FTC, FTA, and FTTD ranged from 3.21 cm, 0.58 cm(2), and 1.19 cm at 22 weeks to 5.11 cm, 1.69 cm(2), and 1.89 cm at 35 weeks, respectively. Linear regression analysis yielded the following formulas for FTC, FTA, and FTTD according to GA: FTC (cm) = 0.146 X GA (weeks); FTA (cm(2)) = -1.289 + 0.085 X GA (weeks); FTTD (cm) = 0.054 X GA (weeks). The following logarithmic formulas were obtained for the expected fetal thyroid measurements according to estimated fetal weight (FW): FTC (cm) = -4.791 + 1.265 X logN FW; FTA (cm(2)) = -1.676 + 0.455 X logN FW; and FTTD (cm) = 0.399 + 0.001 X logN FW. Conclusion. We describe new nomograms of fetal thyroid measurements throughout gestation that may be useful in case of thyroid dysfunction. (C) 2008 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND CONTEXT: The vertebral spine angle in the frontal plane is an important parameter in the assessment of scoliosis and may be obtained from panoramic X-ray images. Technological advances have allowed for an increased use of digital X-ray images in clinical practice. PURPOSE: In this context, the objective of this study is to assess the reliability of computer-assisted Cobb angle measurements taken from digital X-ray images. STUDY DESIGN/SETTING: Clinical investigation quantifying scoliotic deformity with Cobb method to evaluate the intra- and interobserver variability using manual and digital techniques. PATIENT SAMPLE: Forty-nine patients diagnosed with idiopathic scoliosis were chosen based on convenience, without predilection for gender, age, type, location, or magnitude of the curvature. OUTCOME MEASURES: Images were examined to evaluate Cobb angle variability, end plate selection, as well as intra- and interobserver errors. METHODS: Specific software was developed to digitally reproduce the Cobb method and calculate semiautomatically the degree of scoliotic deformity. During the study, three observers estimated the Cobb angle using both the digital and the traditional manual methods. RESULTS: The results showed that Cobb angle measurements may be reproduced in the computer as reliably as with the traditional manual method, in similar conditions to those found in clinical practice. CONCLUSIONS: The computer-assisted method (digital method) is clinically advantageous and appropriate to assess the scoliotic curvature in the frontal plane using Cobb method. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The duodenum and proximal jejunum are excluded after Roux-en-Y gastric bypass but these intestinal sites are where iron and zinc are most absorbed. Therefore, they are among the nutrients whose digestive and absorptive process can be impaired after surgery. The aim of the present study was to investigate the iron and zinc plasma response to a tolerance test before and after bariatric surgery. The study was performed at Sao Paulo University School of Medicine of Ribeirao Preto, Brazil. Methods: In a longitudinal paired study, 9 morbidly obese women (body mass index >= 40 kg/m(2)) underwent an iron and zinc tolerance test before and 3 months after surgery. The iron and zinc levels were determined at 0, 1, 2, 3, and 4 hours after a physiologic unique oral dose. The mineral concentrations in die plasma and 24-hour urine sample were assayed using an atomic absorption spectrophotometer. The anthropometric measurements and 3-day food record were also evaluated. A linear mixed model was used to compare the plasma concentration versus interval after the oral dose, before and after surgery. Results: The pre- and postoperative test results revealed a significantly lower plasma zinc response (P <.01) and a delayed response to iron intake after surgery. The total plasma iron concentration area, during the 4 hours, was not different after surgery (P >.05). The 24-hour urinary iron and zinc excretion did not differ between the pre- and postoperative phases. Conclusion: The present data showed a compromised response to the zinc tolerance test after gastric bypass surgery, suggesting an impaired absorption of zinc. More attention must be devoted to zinc nutritional status after surgery. (Surg Obes Relat Dis 2011;7:309-314.) (C) 2011 American Society for Metabolic and Bariatric Surgery. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The mechanism underlying increased perception of food bolus passage in the absence of esophageal mechanical obstruction has not been completely elucidated. A correlation between the intensity of the symptom and the severity of esophageal dysfunction, either motility (manometry) or bolus transit (impedance) has not been clearly demonstrated. The aim of this study was to analyze the correlation between objective esophageal function assessment (with manometry and impedance) and perception of bolus passage in healthy volunteers (HV) with normal and pharmacologically-induced esophageal hypocontractility, and in patients with gastro-esophageal reflux disease (GERD) with and without ineffective esophageal motility (IEM). Methods Combined manometry-impedance was performed in 10 HV, 19 GERD patients without IEM and nine patients with IEM. Additionally, nine HV were studied after 50 mg sildenafil, which induced esophageal peristaltic failure. Perception of each 5 mL viscous swallow was evaluated using a 5-point scale. Manometry identified hypocontractility (contractions lower than 30 mmHg) and impedance identified incomplete bolus clearance. Key Results In HV and in GERD patients with and without IEM, there was no association between either manometry or impedance and perception on per swallow analysis (OR: 0.842 and OR: 2.017, respectively), as well as on per subject analysis (P = 0.44 and P = 0.16, respectively). Lack of correlation was also found in HV with esophageal hypocontractility induced by sildenafil. Conclusions & Inferences There is no agreement between objective measurements of esophageal function and subjective perception of bolus passage. These results suggest that increased bolus passage perception in patients without mechanical obstruction might be due to esophageal hypersensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate duodenocecostomy in horses performed through a ventral midline laparotomy and report its influence oil body weight, glucose absorption, serum components, and characteristics of jejunum, cecum, and large colon histology. Four horses were submitted to the duodenocecostomy technique through a ventral midline laparotomy with animals in dorsal recumbency under inhalation anesthesia, followed by abdominal exploration. A side-to-side anastomosis was performed between the duodenojejunal flexure and the base of the cecum with two simple continuous suture lines of the serosal and muscular layers. The size of the opening created was approximately 2 cm in diameter. The mucosa layer was not Sutured. After 30 days, animals were submitted to a second laparotomy to check the patency of the duodenocaecal fistula. During both laparotomy procedures, excisional biopsies of different segments of the gastrointestinal tract were performed. Information on physical examination findings, results of hematologic and histopathologic evaluations, and oral glucose absorption test were recorded. The horses did not have significant weight loss from baseline, and absorption curve of glucose did not significantly vary from baseline. Only triglycerides had significant alterations. Histologic evaluation of jejunum, cecum, and large colon did not show alterations of intestinal structure and morphology. We concluded that the proposed technique, principally in relation to the fistula size and not suturing the mucosa layer, allowed partial or total Occlusion of the fistulae without the necessity of a second surgery and avoided the permanent bypass of ingesta and weight loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective was to evaluate the influence of dental metallic artefacts on implant sites using multislice and cone-beam computed tomography techniques. Ten dried human mandibles were scanned twice by each technique, with and without dental metallic artefacts. Metallic restorations were placed at the top of the alveolar ridge adjacent to the mental foramen region for the second scanning. Linear measurements (thickness and height) for each cross-section were performed by a single examiner using computer software. All mandibles were analysed at both the right and the left mental foramen regions. For the multislice technique, dental metallic artefact produced an increase of 5% in bone thickness and a reduction of 6% in bone height; no significant differences (p > 0.05) were detected when comparing measurements performed with and without metallic artefacts. With respect to the cone-beam technique, dental metallic artefact produced an increase of 6% in bone thickness and a reduction of 0.68% in bone height. No significant differences (p > 0.05) were observed when comparing measurements performed with and without metallic artefacts. The presence of dental metallic artefacts did not alter the linear measurements obtained with both techniques, although its presence made the location of the alveolar bone crest more difficult.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The purpose of this research was to provide further evidence to demonstrate the precision and accuracy of maxillofacial linear and angular measurements obtained by cone-beam computed tomography (CBCT) images. Study design. The study population consisted of 15 dry human skulls that were submitted to CBCT, and 3-dimensional (3D) images were generated. Linear and angular measurements based on conventional craniometric anatomical landmarks, and were identified in 3D-CBCT images by 2 radiologists twice each independently. Subsequently, physical measurements were made by a third examiner using a digital caliper and a digital goniometer. Results. The results demonstrated no statistically significant difference between inter-and intra-examiner analysis. Regarding accuracy test, no statistically significant differences were found of the comparison between the physical and CBCT-based linear and angular measurements for both examiners (P = .968 and .915, P = .844 and .700, respectively). Conclusions. 3D-CBCT images can be used to obtain dimensionally accurate linear and angular measurements from bony maxillofacial structures and landmarks. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 430-436)