143 resultados para null distribution analysis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Blood irradiation can be performed using a dedicated blood irradiator or a teletherapy unit. A thermal device providing appropriate storage conditions during blood components irradiation with a teletherapy unit has been recently proposed. However, the most appropriated volume of the thermal device was not indicated. The goal of this study was to indicate the most appropriated blood volume for irradiation using a teletherapy unit in order to minimize both the dose heterogeneity in the volume and the blood irradiation time using these equipments. Theoretical and experimental methods were used to study the dose distribution in the blood volume irradiated using a linear accelerator and a cobalt-60 therapy machine. The calculation of absorbed doses in the middle plane of cylindrical acrylic volumes was accomplished by a treatment planning system. Experimentally, we also used cylindrical acrylic phantoms and thermoluminescent dosimeters to confirm the calculated doses. The data obtained were represented by isodose curves. We observed that an irradiation volume should have a height of 28 cm and a diameter of 28 cm and a height of 35 cm and a diameter of 35 cm, when the irradiation is to be performed by a linear accelerator and a cobalt-60 teletherapy unit, respectively. Calculated values of relative doses varied from 93% to 100% in the smaller volume, and from 66% to 100% in the largest one. A difference of 5.0%, approximately, was observed between calculated and experimental data. The size of these volumes permits the irradiation of blood bags in only one bath without compromising the homogeneity of the absorbed dose over the irradiated volume. Thus, these irradiation volumes can be recommend to minimize the irradiation time when a teletherapy unit is used to irradiate blood. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. To analyze the psychometric properties of the Brazilian Portuguese version of the Beck Anxiety Inventory (BAI) in terms of its internal consistency, scores distribution, concurrent and discriminant validity, and factorial analysis in a sample of university students and social anxiety disorder (SAD) cases and non-cases. Methods. A sample of Brazilian university students from the general population (N = 2314) and a sample of university students identified as cases (N = 88) and non-cases (N = 90) of SAD were assessed, using as a parameter the Structured Clinical Interview for the DSM-IV. The different instruments were completed individually in the presence of an experienced rater. Results. The BAI showed adequate internal consistency (0.88-0.92) and discriminant validity, with 0.74 sensitivity and 0.71 specificity for a cut-off score of 10. The factorial analysis suggested a three-factor solution to be the most adequate. Conclusions. The version of the BAI studied is quite adequate to be used in the context of Brazilian university students, identifying the presence of anxiety indicators. However, its usefulness to screen for SAD seems limited.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bioelectrical impedance vector analysis (BIVA) is a new method that is used for the routine monitoring of the variation in body fluids and nutritional status with assumptions regarding body composition values. The aim of the present study was to determine bivariate tolerance intervals of the whole-body impedance vector and to describe phase angle (PA) values for healthy term newborns aged 7-28 d. This descriptive cross-sectional study was conducted on healthy term neonates born at a low-risk public maternity. General and anthropometric neonatal data and bioelectrical impedance data (800 mu A-50 kHz) were obtained. Bivariate vector analysis was conducted with the resistance-reactance (RXc) graph method. The BIVA software was used to construct the graphs. The study was conducted on 109 neonates (52.3% females) who were born at term, adequate for gestational age, exclusively breast-fed and aged 13 (SD 3.6) d. We constructed one standard, reference, RXc-score graph and RXc-tolerance ellipses (50, 75 and 95 %) that can be used with any analyser. Mean PA was 3.14 (SD 0.43)degrees (3.12 (SD 0.39)degrees for males and 3.17 (SD 0.48)degrees for females). Considering the overlapping of ellipses of males and females with the general distribution, a graph for newborns aged 7-28 d with the same reference tolerance ellipse was defined for boys and girls. The results differ from those reported in the literature probably, in part, due to the ethnic differences in body composition. BIVA and PA permit an assessment without the need to know body weight and the prediction error of conventional impedance formulas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Phylogenetic analyses based on mitochondrial 16S rDNA sequences were generated from Rhipicephalus sanguineus group specimens collected in 29 localities among 9 Latin-American countries, plus ticks collected in South Africa, Spain, and Italy. Sequences from Latin America generated six different haplotypes (A, B, C, D, E, and F). Phylogenetic analyses generated trees that segregated our tick sequences into two distinct clades: one is represented by haplotypes A-C, and South African R. sanguineus and Rhipicephalus turanicus ticks; the second clade is represented by haplotypes D-F, and European R. sanguineus and R. turanicus ticks. When haplotypes A-Fare plotted in the Latin America map according to their geographical coordinates, it is clearly seen that haplotypes D-F are restricted to the southern portion of this continent, whereas haplotypes A-C are distributed in areas between northern Mexico and Brazil (except for the extreme south of this last country, where haplotype E was present). Hence, our phylogenetic analyses separated New World specimens of R. sanguineus into two distinct clades, one represented by tropical and subtropical populations (haplotypes A-C), here designated as the `tropical` species. On the other hand, haplotypes D-F are here designated as the `temperate` species because of their distribution in the southern portion of South America. Until recently, it was assumed that the R. sanguineus group was represented by a single species in the New World, namely R. sanguineus. While the present results coupled with recent studies support the presence of at least two species under the taxon R. sanguineus in the New World, they also show that even in the Old World, the taxon R. sanguineus might be represented by more than one species, since our phylogenetic analysis segregated European and South African R. sanguineus ticks into two distinct clades. The same can be applied for Spanish and South African R. turanicus. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The critically endangered black-faced lion tamarin, Leontopithecus caissara, has a restricted geographical distribution consisting of small mainland and island populations, each with distinct habitats in coastal southeastern Brazil. Necessary conservation management actions require an assessment of whether differences in habitats are reflected in use of space by the species. We studied two tamarin groups on the mainland at Sao Paulo state between August 2005 and March 2007, and compared the results with data from Superagui Island. Three home range estimators were used: minimum convex polygon (MCP), Kernel, and the new technique presented dissolved monthly polygons (DMP). These resulted, respectively, in home ranges of 345, 297, and 282 ha for the 12-month duration of the study. Spatial overlap of mainland groups was extensive, whereas temporal overlap was not, a pattern that indicates resource partitioning is an important strategy to avoid intraspecific competition. L. caissara large home ranges seem to be dynamic, with constant incorporation of new areas and abandonment of others through time. The main difference between mainland and island groups is the amount and variety of sleeping sites. A better understanding of the home range sizes, day range lengths, and territorial behavior of this species will aid in developing better management strategies for its protection. Additionally, the presented DMP protocol is a useful improvement over the MCP method as it results in more realistic home range sizes for wildlife species. Am. J. Primatol. 73: 1114-1126, 2011. (C) 2011 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stress distributions in torsion and wire-loop shear tests were compared using three-dimensional (3-D) linear-elastic finite element method, in an attempt to predict the ideal conditions for testing adhesive strength of dental resin composites to dentin. The torsion test presented lower variability in stress concentration at the adhesive interface with changes in the proportion adhesive thickness/resin composite diameter, as well as lower variability with changes in the resin composite elastic modulus. Moreover, the torsion test eliminated variability from changes in loading distance, and reduced the cohesive fracture tendency in the dentin. The torsion test seems to be more appropriate than wire-loop shear test for testing the resin composite-tooth interface strength. (c) Koninklijke Brill NV, Leiden, 2009

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Understanding how clinical variables affect stress distribution facilitates optimal prosthesis design and fabrication and may lead to a decrease in mechanical failures as well as improve implant longevity. Purpose: In this study, the many clinical variations present in implant-supported prosthesis were analyzed by 3-D finite element method. Materials and Method: A geometrical model representing the anterior segment of a human mandible treated with 5 implants supporting a framework was created to perform the tests. The variables introduced in the computer model were cantilever length, elastic modulus of cancellous bone, abutment length, implant length, and framework alloy (AgPd or CoCr). The computer was programmed with physical properties of the materials as derived from the literature, and a 100N vertical load was used to simulate the occlusal force. Images with the fringes of stress were obtained and the maximum stress at each site was plotted in graphs for comparison. Results: Stresses clustered at the elements closest to the loading point. Stress increase was found to be proportional to the increase in cantilever length and inversely proportional to the increase in the elastic modulus of cancellous bone. Increasing the abutment length resulted in a decrease of stress on implants and framework. Stress decrease could not be demonstrated with implants longer than 13 mm. A stiffer framework may allow better stress distribution. Conclusion: The relative physical properties of the many materials involved in an implant-supported prosthesis system affect the way stresses are distributed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this in vitro study was to analyze the stress distribution on components of a mandibular-cantilevered implant-supported prosthesis with frameworks cast in cobalt-chromium (Co-Cr) or palladium-silver (Pd-Ag) alloys, according to the cantilever length. Frameworks were fabricated on (Co-Cr) and (Pd-Ag) alloys and screwed into standard abutments positioned on a master-cast containing five implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation. A vertical static load of 100 N was applied to the cantilever arm at the distances of 10, 15, and 20 mm from the center of the distal abutment and the absolute values of specific deformation were recorded. Different patterns of abutment deformation were observed according to the framework alloy. The Co-Cr alloy framework resulted in higher levels of abutment deformation than the silver-palladium alloy framework. Abutment deformation was higher with longer cantilever extensions. Physical properties of the alloys used for framework interfere with abutment deformations patterns. Excessively long cantilever extensions must be avoided. To cite this article:Jacques LB, Moura MS, Suedam V, Souza EAC, Rubo JH. Effect of cantilever length and framework alloy on the stress distribution of mandibular-cantilevered implant-supported prostheses.Clin. Oral Impl. Res. 20, 2009; 737-741.doi: 10.1111/j.1600-0501.2009.01712.x.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In cantilevered implant-supported complete prosthesis, the abutments` different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis. A circular steel master cast with five perforations containing implant replicas (O3.75 mm) was used. Two groups were formed according to the types of alloy of the framework (CoCr or PdAg). Three frameworks were made for each group to be tested with 4, 5.5 and 7 mm abutments. A 100 N load was applied at a point 15 mm distal to the center of the terminal implant. Readings of the deformations generated on the mesial and distal aspects of the abutments were obtained with the use of strain gauges. Deformation caused by tension and compression was observed in all specimens with the terminal abutment taking most of the load. An increase in deformation was observed in the terminal abutment as the height was increased. The use of an alloy of higher elastic modulus (CoCr) also caused the abutment deformation to increase. Abutment`s height and framework alloy influence the deformation of abutments of mandibular cantilevered implant-supported prosthesis. To cite this article:Suedam V, Capello SouzaEA, Moura MS, Jacques LB, Rubo JH. Effect of abutment`s height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin. Oral Impl. Res. 20, 2009; 196-200.doi: 10.1111/j.1600-0501.2008.01609.x.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The objective of this study was to evaluate the stress on the cortical bone around single body dental implants supporting mandibular complete fixed denture with rigid (Neopronto System-Neodent) or semirigid splinting system (Barra Distal System-Neodent). Methods and Materials: Stress levels on several system components were analyzed through finite element analysis. Focusing on stress concentration at cortical bone around single body dental implants supporting mandibular complete fixed dentures with rigid ( Neopronto System-Neodent) or semirigid splinting system ( Barra Distal System-Neodent), after axial and oblique occlusal loading simulation, applied in the last cantilever element. Results: The results showed that semirigid implant splinting generated lower von Mises stress in the cortical bone under axial loading. Rigid implant splinting generated higher von Mises stress in the cortical bone under oblique loading. Conclusion: It was concluded that the use of a semirigid system for rehabilitation of edentulous mandibles by means of immediate implant-supported fixed complete denture is recommended, because it reduces stress concentration in the cortical bone. As a consequence, bone level is better preserved, and implant survival is improved. Nevertheless, for both situations the cortical bone integrity was protected, because the maximum stress level findings were lower than those pointed in the literature as being harmful. The maximum stress limit for cortical bone (167 MPa) represents the threshold between plastic and elastic state for a given material. Because any force is applied to an object, and there is no deformation, we can conclude that the elastic threshold was not surpassed, keeping its structural integrity. If the force is higher than the plastic threshold, the object will suffer permanent deformation. In cortical bone, this represents the beginning of bone resorption and/or remodeling processes, which, according to our simulated loading, would not occur. ( Implant Dent 2010; 19:39-49)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Primary teeth were analyzed by micro-SRXRF. The aim of this study was to determine the elemental distribution of lead and calcium in different regions of primary incisor of children living in a notoriously contaminated area (Santo Amaro da Purificacao, Bahia State, Brazil). The measurements were performed in standard geometry of 45 incidence, exciting with a white beam and using a conventional system collimation (orthogonal slits) in the XRF beamline at the Synchrotron Light National Laboratory (Campinas, Brazil). (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is no consensus in literature regarding the best plan for prosthetic rehabilitation with partial multiple adjacent implants to minimize stress generated in the bone-implant interface. The aim of this study was to evaluate the biomechanical behavior of cemented fixed partial dentures, splinted and nonsplinted, on Morse taper implants and with different types of coating material (ceramic and resin), using photoelastic stress analysis. A photoelastic model of an interposed edentulous space, missing a second premolar and a first molar, and rehabilitated with 4 different types of cemented crowns and supported by 2 adjacent implants was used. Groups were as follows: UC, splinted ceramic crowns; IC, nonsplinted ceramic crowns; UR, splinted resin crowns; and IR, nonsplinted resin crowns. Different vertical static loading conditions were performed: balanced occlusal load, 10 kgf; simultaneous punctiform load on the implanted premolar and molar, 10 kgf; and alternate punctiform load on the implanted premolar and molar, 5 kgf. Changes in stress distribution were analyzed in a polariscope, and digital photographs were taken of each condition to allow comparison of stress pattern distribution around the implants. Cementation of the fixed partial dentures generated stresses between implants. Splinted restorations distributed the stresses more evenly between the implants than nonsplinted when force was applied. Ceramic restorations presented better distribution of stresses than resin restorations. Based on the results obtained, it was concluded that splinted ceramic restorations promote better stress distribution around osseointegrated implants when compared with nonsplinted crowns; metal-ceramic restorations present less stress concentration and magnitude than metal-plastic restorations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The current study evaluated the influence of two endodontic post systems and the elastic modulus and film thickness of resin cement on stress distribution in a maxillary central incisor (MCI) restored with direct resin composite using finite element analysis (FEA). A three-dimensional model of an MCI with a coronary fracture and supporting structures was performed. A static chewing pressure of 2.16 N/mm(2) was applied to two areas on the palatal surface of the composite restoration. Zirconia ceramic (ZC) and glass fiber (GF) posts were considered. The stress distribution was analyzed in the post, dentin and cement layer when ZC and GF posts were fixed to the root canals using resin cements of different elastic moduli (7.0 and 18.6 GPa) and different layer thicknesses (70 and 200 mu m). The different post materials presented a significant influence on stress distribution with lesser stress concentration when using the GF post. The higher elastic modulus cement created higher stress levels within itself. The cement thicknesses did not present significant changes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background The objectives were to estimate the prevalence of hepatitis A among children and adolescents from the Northeast and Midwest regions and the Federal District of Brazil and to identify individual-, household- and area-levels factors associated with hepatitis A infection. Methods This population-based survey was conducted in 20042005 and covered individuals aged between 5 and 19 years. A stratified multistage cluster sampling technique with probability proportional to size was used to select 1937 individuals aged between 5 and 19 years living in the Federal capital and in the State capitals of 12 states in the study regions. The sample was stratified according to age (59 and 10- to 19-years-old) and capital within each region. Individual- and household-level data were collected by interview at the home of the individual. Variables related to the area were retrieved from census tract data. The outcome was total antibodies to hepatitis A virus detected using commercial EIA. The age distribution of the susceptible population was estimated using a simple catalytic model. The associations between HAV infection and independent variables were assessed using the odds ratio and corrected for the random design effect and sampling weight. Multilevel analysis was performed by GLLAMM using Stata 9.2. Results The prevalence of hepatitis A infection in the 59 and 1019 age-group was 41.5 and 57.4, respectively for the Northeast, 32.3 and 56.0, respectively for the Midwest and 33.8 and 65.1 for the Federal District. A trend for the prevalence of HAV infection to increase according to age was detected in all sites. By the age of 5, 31.5 of the children had already been infected with HAV in the Northeast region compared with 20.0 in the other sites. By the age of 19 years, seropositivity was 70 in all areas. The curves of susceptible populations differed from one area to another. Multilevel modeling showed that variables relating to different levels of education were associated with HAV infection in all sites. Conclusion The study sites were classified as areas with intermediate endemicity area for hepatitis A infection. Differences in age trends of infection were detected among settings. This multilevel model allowed for quantification of contextual predictors of hepatitis A infection in urban areas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main goal of this work was to evaluate thermodynamic parameters of the soybean oil extraction process using ethanol as solvent. The experimental treatments were as follows: aqueous solvents with water contents varying from 0 to 13% (mass basis) and extraction temperature varying from 50 to 100 degrees C. The distribution coefficients of oil at equilibrium have been used to calculate enthalpy, entropy and free energy changes. The results indicate that oil extraction process with ethanol is feasible and spontaneous, mainly under higher temperature. Also, the influence of water level in the solvent and temperature were analysed using the response surface methodology (RSM). It can be noted that the extraction yield was highly affected by both independent variables. A joint analysis of thermodynamic and RSM indicates the optimal level of solvent hydration and temperature to perform the extraction process.