101 resultados para metal-radical exchange


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Oncologic outcomes in men with radiation-recurrent prostate cancer (PCa) treated with salvage radical prostatectomy (SRP) are poorly defined. Objective: To identify predictors of biochemical recurrence (BCR), metastasis, and death following SRP to help select patients who may benefit from SRP. Design, setting, and participants: This is a retrospective, international, multi-institutional cohort analysis. There was amedian follow-up of 4.4 yr following SRP performed on 404 men with radiation-recurrent PCa from 1985 to 2009 in tertiary centers. Intervention: Open SRP. Measurements: BCR after SRP was defined as a serum prostate-specific antigen (PSA) >= 0.1 or >= 0.2 ng/ml (depending on the institution). Secondary end points included progression to metastasis and cancerspecific death. Results and limitations: Median age at SRP was 65 yr of age, and median pre-SRP PSA was 4.5 ng/ml. Following SRP, 195 patients experienced BCR, 64 developed metastases, and 40 died from PCa. At 10 yr after SRP, BCR-free survival, metastasis-free survival, and cancer-specific survival (CSS) probabilities were 37% (95% confidence interval [CI], 31-43), 77% (95% CI, 71-82), and 83% (95% CI, 76-88), respectively. On preoperative multivariable analysis, pre-SRP PSA and Gleason score at postradiation prostate biopsy predicted BCR (p = 0.022; global p < 0.001) and metastasis (p = 0.022; global p < 0.001). On postoperative multivariable analysis, pre-SRP PSA and pathologic Gleason score at SRP predicted BCR (p = 0.014; global p < 0.001) and metastasis (p < 0.001; global p < 0.001). Lymph node involvement (LNI) also predicted metastasis (p = 0.017). The main limitations of this study are its retrospective design and the follow-up period. Conclusions: In a select group of patients who underwent SRP for radiation-recurrent PCa, freedom from clinical metastasis was observed in > 75% of patients 10 yr after surgery. Patients with lower pre-SRP PSA levels and lower postradiation prostate biopsy Gleason score have the highest probability of cure from SRP. (C) 2011 European Association of Urology. Published by Elsevier B. V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Several studies have shown that robot-assisted laparoscopic radical prostatectomy (RALP) is feasible, with favorable complication rates and short hospital times. However, the early recovery of urinary continence remains a challenge to be overcome. Objective: We describe our technique of periurethral retropubic suspension stitch during RALP and report its impact on early recovery of urinary continence. Design, setting, and participants: We analyze prospectively 331 consecutive patients who underwent RALP, 94 without the placement of suspension stitch (group 1) and 237 with the application of the suspension stitch (group 2). Surgical procedure: The only difference between the groups was the placement of the puboperiurethral stitch after the ligation of the dorsal venous complex (DVC). The periurethral retropubic stitch was placed using a 12-in monofilament polyglytone suture on a CTI needle. The stitch was passed from right to left between the urethra and DVC, and then through the periostium on the pubic bone. The stitch was passed again through the DVC, and then through the pubic bone in a figure eight, and then tied. Measurements: Continence rates were assessed with a self-administered validated questionnaire (Expanded Prostate Cancer Index Composite [EPIC] at 1, 3, 6, and 12 mo after the procedure. Continence was defined as the use of no absorbent pads or no leakage of urine. Results and limitations: In group 1, the continence rate at 1, 3, 6, and 12 mo postoperatively was 33%, 83%, 94.7%, and 95.7%, respectively; in group 2, the continence rate was 40%, 92.8%, 97.9%, and 97.9%, respectively. The suspension technique resulted in significantly greater continence rates at 3 mo after RALP (p = 0.013). The median/mean interval to recovery of continence was also statistically significantly shorter in the suspension group (median: 6 wk; mean: 7.338 wk: 95% confidence interval [CI]: 6.387-8.288) compared to the non-suspension group (median: 7 wk; mean: 9.585 wk: 95% CI: 7.558-11.612; log rank test, p = 0.02). Conclusions: The suspension stitch during RALP resulted in a statistically significantly shorter interval to recovery of continence and higher continence rates at 3 mo after the procedure. (C) 2009 European Association of Urology. Published by Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To investigate the feasibility of radical retropubic prostatectomy (RRP) in renal transplant recipients with clinically localized prostate cancer. METHODS A prospective protocol was established between August 2004 and November 2007. In that period, 8 patients diagnosed with localized prostate cancer were submitted to RRP, and their clinicopathologic data were reviewed. RESULTS The mean age (standard deviation) at surgery was 59.6 +/- 6.7 years (range, 49-67 years). All patients had TIC tumors, except for 1 with a T2A tumor. The mean preoperative prostate-specific antigen value was 4.5 +/- 1.8 ng/mL (range, 1.6-7.0 ng/mL). The mean interval between renal transplantation and RRP was 89.9 +/- 65.1 months (range, 40-209 months). The procedure was well tolerated without major complications, and all patients were discharged on the fifth postoperative day. There was no impairment to bladder descent caused by the presence of the allograft or the ureteroneocystostomy. Urethrovesical anastomosis was easily performed in all cases in the standard manner. Blood transfusion was needed in 2 patients (1 received 2 U and another 5 U of blood). The mean operative duration was 183 +/- 29.7minutes (range, 150-240 minutes), the mean estimated blood loss was 656 +/- 576 mL (range, 100-2000 mL), and no deterioration of graft function was observed. All patients were followed, and the mean follow-up was 10.5 months (range, 2-30 months). Prostate-specific antigen was undetectable in all cases during this time frame. CONCLUSIONS Radical retropubic prostatectomy in renal transplant patients is safe, effective, and can be easily performed in the same manner as described by Walsh, regardless of the presence of the allograft. The only necessary technical modification is the avoidance of ipsilateral lymphadenectomy to prevent damage to the transplanted organ. UROLOGY 72: 1362-1365, 2008. (C) 2008 Elsevier Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To develop a rat model of erectile dysfunction (ED) after cavernous nerve injury. Given the great similarity between the anatomical structure of the cavernous nerve in rats and humans, 24 rats underwent dissections and the cavernous nerves were identified with the aid of an operating microscope. Then the rats were randomized into two groups: sham-operated controls and a bilateral cavernous nerve section group. At 3 months after surgery, the rats were evaluated for their response to an apomorphine challenge. The erectile response after an apomorphine challenge was normal in all the control rats, while there were no erections in the bilateral injured group. The rat major autonomic ganglion and its cavernous nerve can be identified with the aid of a microscope. Rats are inexpensive and easy to handle, thus a good animal for developing an ED model of cavernous nerve injury. In the present study, the rats with cavernous nerve injury lost erectile capacity in a reliable and reproducible fashion. Because of the great similarity between the cavernous nerve of rats and humans, one may consider this technique as a reliable experimental model for studying ED after radical prostatectomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Widespread use of prostate-specific antigen screening has resulted in younger and healthier men being diagnosed with prostate cancer. Their demands and expectations of surgical intervention are much higher and cannot be adequately addressed with the classic trifecta outcome measures. Objective: A new and more comprehensive method for reporting outcomes after radical prostatectomy, the pentafecta, is proposed. Design, setting, and participants: From January 2008 through September 2009, details of 1111 consecutive patients who underwent robot-assisted radical prostatectomy performed by a single surgeon were retrospectively analyzed. Of 626 potent men, 332 who underwent bilateral nerve sparing and who had 1 yr of follow-up were included in the study group. Measurements: In addition to the traditional trifecta outcomes, two perioperative variables were included in the pentafecta: no postoperative complications and negative surgical margins. Patients who attained the trifecta and concurrently the two additional outcomes were considered as having achieved the pentafecta. A logistic regression model was created to evaluate independent factors for achieving the pentafecta. Results and limitations: Continence, potency, biochemical recurrence-free survival, and trifecta rates at 12 mo were 96.4%, 89.8%, 96.4%, and 83.1%, respectively. With regard to the perioperative outcomes, 93.4% had no postoperative complication and 90.7% had negative surgical margins. The pentafecta rate at 12 mo was 70.8%. On multivariable analysis, patient age (p = 0.001) was confirmed as the only factor independently associated with the pentafecta. Conclusions: A more comprehensive approach for reporting prostate surgery outcomes, the pentafecta, is being proposed. We believe that pentafecta outcomes more accurately represent patients` expectations after minimally invasive surgery for prostate cancer. This approach may be beneficial and may be used when counseling patients with clinically localized disease. (C) 2011 European Association of Urology. Published by Elsevier B. V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. There are no established clinical procedures for bonding zirconia to tooth structure using resin cements. Purpose. The purpose of this study was to evaluate the influence of metal primers, resin cements, and aging on bonding to zirconia. Material and methods. Zirconia was treated with commercial primers developed for bonding to metal alloys (Metaltite, Metal Primer II, Alloy Primer or Totalbond). Non-primed specimens were considered as controls. One-hundred disk-shaped specimens (19 x 4 mm) were cemented to composite resin substrates using Panavia or RelyX Unicem (n=5). Microtensile bond strength specimens were tested after 48 hours and 5 months (150 days), and failure modes were classified as type 1 (between ceramic/cement), 2 (between composite resin/cement) or 3 (mixed). Data were analyzed by 3-way ANOVA and Multiple Comparison Tukey test (alpha=.05). Results. The interactions primer/luting system (P=.016) and luting system/storage time (P=.004) were statistically significant. The use of Alloy Primer significantly improved the bond strength of RelyX Unicem (P<.001), while for Panavia, none of the primers increased the bond strength compared to the control group. At 48 hours, Panavia had statistically higher bond strength (P=.004) than Unicem (13.9 +/- 4.4MPa and 10.2 +/- 6.6MPa, respectively). However, both luting systems presented decreasing, statistically similar; values after aging (Panavia: 3.6 +/- 2.2MPa; Unicem: 6.1 +/- 5.3MPa). At 48 hours, Alloy Primer/Unicem had the lowest incidence of type 1 failure (8%). After aging, all the groups showed a predominance of type 1 failures. Conclusions. The use of Alloy Primer improved bond strength between RelyX Unicem and zirconia. Though the initial values obtained with Panavia were significantly higher than RelyX Unicem, after aging, both luting agents presented statistically similar performances. (J Prosthet Dent 2011;105:296-303)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the effect of the ion exchange treatment on the R-curve behavior of a leucite-reinforced dental porcelain, testing the hypothesis that the ion exchange is able to improve the R-curve behavior of the porcelain studied. Porcelain disks were sintered, finely polished, and submitted to an ion exchange treatment with a KNO(3) paste. The R-curve behavior was assessed by fracturing the specimens in a biaxial flexure design after making Vickers indentations in the center of the polished surface with loads of 1.8, 3.1, 4.9, 9.8, 31.4, and 49.0 N. The results showed that the ion exchange process resulted in significant improvements in terms of fracture toughness and flexural strength as compared to the untreated material. Nevertheless, the rising R-curve behavior previously observed in the control group disappeared after the ion exchange treatment, i.e., fracture toughness did not increase with the increase in crack size for the treated group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to determine the influence of different ion-exchange temperatures on the biaxial flexural strength (sigma(f)), hardness (HV) and indentation fracture resistance (K(IF)) of a dental porcelain. Disk-shaped specimens were divided into five groups (n = 10) and submitted to an ion-exchange procedure using KNO(3) paste for 15 min in the following temperatures (degrees C); (I) 430; (II) 450; (III) 470; (IV) 490; (V) 510; and control (no ion exchange). The value of sigma(f) was determined in artificial saliva at 37 degrees C. The values of HV and K(IF) were obtained using 3 Vickers indentations in each specimen (19.6 N). Results showed that ion exchange increases significantly the properties of the material as compared to the control and no significant differences were found among the temperatures tested for any of the properties studied. (C) 2010 Elsevier Ltd and Techna Group S.r.l. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To determine the effect of ion exchange on slow crack growth (SCG) parameters (n, stress corrosion susceptibility coefficient, and sigma(f0), scaling parameter) and Weibull parameters (m, Weibull modulus, and sigma(0), characteristic strength) of a dental porcelain. Methods. 160 porcelain discs were fabricated according to manufacturer`s instructions, polished through 1 mu m and divided into two groups: GC (control) and GI (submitted to an ion exchange procedure using a KNO(3) paste at 470 degrees C for 15 min). SCG parameters were determined by biaxial flexural strength test in artificial saliva at 37 degrees C using five constant stress rates (n =10). 20 specimens of each group were tested at 1 MPa/s to determine Weibull parameters. The SPT diagram was constructed using the least-squares fit of the strength data versus probability of failure. Results. Mean values of m and sigma(0) (95% confidence interval), n and sigma(f0) (standard deviation) were, respectively: 13.8 (10.1-18.8) and 60.4 (58.5 - 62.2), 24.1 (2.5) and 58.1 (0.01) for GC and 7.4 (5.3 -10.0) and 136.8 (129.1-144.7), 36.7 (7.3) and 127.9 (0.01) for GI. Fracture stresses (MPa) calculated using the SPT diagram for lifetimes of 1 day, 1 year and 10 years (at a 5% failure probability) were, respectively, 31.8, 24.9 and 22.7 for GC and 71.2, 60.6 and 56.9 for GI. Significance. For the porcelain tested, the ion exchange process improved strength and resistance to SCG, however, the material`s reliability decreased. The predicted fracture stress at 5% failure probability for a lifetime of 10 years was also higher for the ion treated group. (C) 009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of framework design on the fracture resistance of metal-ceramic implant-supported crowns. Screw-retained molar crowns with a screw access hole composed of metal or porcelain were compared to a cement-retained crown (control). For each group (n = 10), five crowns were subjected to dynamic loading (1,200,000 x 100 N x 2 Hz at 37 degrees C). Afterward, all specimens were loaded to failure using a universal testing machine. Significant differences could be established between the cement-and screw-retained groups (P <= .05), but no difference was found between the screw-retained groups and the specimens subjected to dynamic loading. Occlusal discontinuity of screw-retained crowns affects their resistance, and the metallic support on the screw access hole did not reinforce the crowns. Int J Prosthodont 2010;23:350-352.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. Dental fractures can occur in endodontically treated teeth restored with posts. Purpose. The purpose of this study was to evaluate the in vitro fracture resistance of roots with glass-fiber and metal posts of different lengths. Material and methods. Sixty endodontically treated maxillary canines were embedded in acrylic resin, except for 4 mm of the cervical area, after removing the clinical crowns. The post spaces were opened with a cylindrical bur at low speed attached to a surveyor, resulting in preparations with lengths of 6 mm (group 6 mm), 8 mm (group 8 mm), or 10 mm (group 10 mm). Each group was divided into 2 subgroups according to the post material: cast post and core or glass-fiber post (n=30). The posts were luted with dual-polymerizing resin cement (Panavia F). Cast posts and cores of Co-Cr (Resilient Plus) crowns were made and cemented with zinc phosphate. Specimens were subjected to increasing compressive load (N) until fracture. Data were analyzed with 2-way ANOVA and the Tukey-Kramer test (alpha=.05). Results. The ANOVA analysis indicated significant differences (P<.05) among the groups, and the Tukey test revealed no significant difference among the metal posts of 6-mm length (26.5 N +/- 13.4), 8-mm length (25.2 N +/- 13.9), and 10-mm length (17.1 N +/- 5.2). Also, in the glass-fiber post group, there was no significant difference when posts of 8-mm length (13.4 N +/- 11.0) were compared with the 6-mm (6.9 N +/- 4.6) and 10-mm (31.7 N +/- 13.1) groups. The 10-mm-long post displayed superior fracture resistance, and the 6-mm-long post showed significantly lower mean values (P<.001). Conclusions. Within the limitations of this study, it was concluded that the glass-fiber post represents a viable alternative to the cast metal post, increasing the resistance to fracture of endodontically treated canines. (J Prosthet Dent 2009;101:183-188)