112 resultados para Protocol design


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: In the literature there is no validated instrument for the clinical evaluation of the orofacial myofunctional condition of children that will permit the examiner to express numerically his perception of the characteristics and behaviors observed. The proposal of this study is to describe a protocol for the evaluation of children aged 6-12 years in order to establish relations between the orofacial. myofunctional conditions and numerical scales. The protocol validity, reliability of the examiners and agreement between them was analyzed. Methods: Eighty children aged 6-12 years participated in the study. All were evaluated and 30 were selected at random for the analyses (age range: 72-149 months, mean = 103.3, S.D. = 23.57). Individuals with and without orofacial myofunctional. disorders were included. The examiners were two speech therapists property calibrated in orofacial myofunctional evaluation. Two protocols were constructed. One, based on traditional models, was called traditional orofacial. myofunctional. evaluation (TOME), and the other, with the addition of numerical scales, was called orofacial myofunctional. evaluation with scores (OMES). The clinical conditions included were: appearance, posture and mobility of lips, tongue, cheeks and jaws, respiration, mastication and deglutition. Statistical analysis was performed using the split-half reliability method. Means, standard deviations and the Spearman correlation coefficient were also calculated. Results: There was a statistically significant correlation between the evaluations of 30 children assessed with the TOME and OMES protocols (r = 0.85, p < 0.01). The reliability between protocols was 0.92. The test-retest reliability of the OMES instrument was 0.99 and the correlation was 0.98. Reliability between examiners 1 and 2 using the OMES protocol was 0.99, and the correlation was 0.98 (P < 0.01). Conclusion: The OMES protocot proved to be a valid and reliable instrument for orofacial myofunctional evaluation, permitting the grading of orofacial myofunctional conditions within the limits of the selected items. (c) 2007 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To describe event-free survival (EFS) and toxicities in children with low-risk acute lymphoblastic leukemia (ALL) assigned to receive either continuous 6-mercaptopurine (6-MP) and weekly methotrexate (MIX) or intermittent 6-MP with intermediate-dose MTX, as maintenance treatment. Patients and Methods Between October 1, 2000, and December 31, 2007, 635 patients with low-risk ALL were enrolled onto Brazilian Childhood Cooperative Group for ALL Treatment (GBTLI) ALL-99 protocol. Eligible children (n=544) were randomly allocated to receive either continuous 6-ME/MIX (group 1, n 272) or intermittent 6-MP (100 mg/m(2)/d for 10 days, with 11 days resting) and MIX (200 mg/m(2) every 3 weeks; group 2, n = 272). Results The 5-year overall survival (OS) and EFS were 92.5% +/- 1.5% SE and 83.6% +/- 2.1% SE, respectively. According to maintenance regimen, the OS was 91.4% +/- 2.2% SE (group 1) and 93.6% +/- 2.1% SE (group 2; P=.28) and EFS 80.9% +/- 3.2% SE (group 1) and 86.5% +/- 2.8% SE (group 2; P=.089). Remarkably, the intermittent regimen led to significantly higher EFS among boys (85.7% v 74.9% SE; P=027), while no difference was seen for girls (87.0% v 88.8% SE; P=.78). Toxic episodes were recorded in 226 and 237 children, respectively. Grade 3 to 4 toxic events for groups 1 and 2 were, respectively, 273 and 166 for hepatic dysfunction (P=.002), and 772 and 636 for hematologic episodes (P=.005). Deaths on maintenance were: seven (group 1) and one (group 2). Conclusion The intermittent use of 6-MP and MIX in maintenance is a less toxic regimen, with a trend toward better long-term EFS. Boys treated with the intermittent schedule had significantly better EFS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Limb praxis can be influenced by age, gender, and education. The present Study investigated the influence of these variables on gesture production by healthy elderly Subjects. We evaluated 96 individuals divided into two age groups (60-74 and 75-88 years). Each group contained 48 men and 48 women and was subdivided into four groups according to education: illiterates and 1-3, 4-7, and 8 or more years of education. Individuals were requested to carry Out tasks oil verbal command and imitation. There were no differences between the performance of men and women, while older individuals performed worse than their younger counterparts. Regarding educational level, three major groups emerged: illiterates, individuals with 1-7 years of education, and those with 8 or more years of education. In conclusion, age and education significantly influenced the performance of individuals in limb praxis tests. (JINS, 2009, 157 618-622.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context In 2007, the effects of the autologous nonmyeloablative hematopoietic stem cell transplantation (HSCT) in 15 patients with type 1 diabetes mellitus (DM) were reported. Most patients became insulin free with normal levels of glycated hemoglobin A(1c) (HbA(1c)) during a mean 18.8-month follow-up. To investigate if this effect was due to preservation of beta-cell mass, continued monitoring was performed of C-peptide levels after stem cell transplantation in the 15 original and 8 additional patients. Objective To determine C-peptide levels after autologous nonmyeloablative HSCT in patients with newly diagnosed type 1 DM during a longer follow-up. Design, Setting, and Participants A prospective phase 1/2 study of 23 patients with type 1 DM(aged 13-31 years) diagnosed in the previous 6 weeks by clinical findings with hyperglycemia and confirmed by measurement of serum levels of anti glutamic acid decarboxylase antibodies. Enrollment was November 2003-April 2008, with follow-up until December 2008 at the Bone Marrow Transplantation Unit of the School of Medicine of Ribeirao Preto, Ribeirao Preto, Brazil. Hematopoietic stem cells were mobilized via the 2007 protocol. Main Outcome Measures C-peptide levels measured during the mixed-meal tolerance test, before, and at different times following HSCT. Secondary end points included morbidity and mortality from transplantation, temporal changes in exogenous insulin requirements, and serum levels of HbA1c. Results During a 7- to 58-month follow-up (mean, 29.8 months; median, 30 months), 20 patients without previous ketoacidosis and not receiving corticosteroids during the preparative regimen became insulin free. Twelve patients maintained this status for a mean 31 months (range, 14-52 months) and 8 patients relapsed and resumed insulin use at low dose (0.1-0.3 IU/kg). In the continuous insulin-independent group, HbA(1c) levels were less than 7.0% and mean (SE) area under the curve (AUC) of C-peptide levels increased significantly from 225.0 (75.2) ng/mL per 2 hours pretransplantation to 785.4 (90.3) ng/mL per 2 hours at 24 months posttransplantation (P<.001) and to 728.1 (144.4) ng/mL per 2 hours at 36 months (P=.001). In the transient insulin-independent group, mean (SE) AUC of C-peptide levels also increased from 148.9 (75.2) ng/mL per 2 hours pretransplantation to 546.8 (96.9) ng/mL per 2 hours at 36 months (P=.001), which was sustained at 48 months. In this group, 2 patients regained insulin independence after treatment with sitagliptin, which was associated with increase in C-peptide levels. Two patients developed bilateral nosocomial pneumonia, 3 patients developed late endocrine dysfunction, and 9 patients developed oligospermia. There was no mortality. Conclusion After a mean follow-up of 29.8 months following autologous nonmyeloablative HSCT in patients with newly diagnosed type 1 DM, C-peptide levels increased significantly and the majority of patients achieved insulin independence with good glycemic control. Trial Registration clinicaltrials.gov Identifier: NCT00315133

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate the effect of aerobic physical training on cardiovascular autonomic control in ovariectomized rats using different approaches. Design: Female Wistar rats were divided into four groups: sedentary sham rats (group SSR), trained sham rats (group TSR), sedentary ovariectomized rats (group SOR), and trained ovariectomized rats (group TOR). Animals from the trained groups were submitted to a physical training protocol (swimming) for 12 weeks. Results: Pharmacological evaluation showed that animals from group TSR had an increase in their cardiac vagal tonus compared with the animals from groups SSR and SOR. The analysis of heart rate variability (HRV) showed that groups TSR and SOR had fewer low-frequency oscillations (0.20-0.75 Hz) compared with groups SSR and TOR. When groups TSR and SOR were compared, the former was found to have fewer oscillations. With regard to high-frequency oscillations (0.75-2.5 Hz), group SSR had a reduction compared with the other groups, whereas group TSR had the greatest oscillation compared with groups SOR and TOR, with all values expressed in normalized units. Analysis of HRV was performed after pharmacological blockade, and low-frequency oscillations were found to be predominantly sympathetic in sedentary animals, whereas there was no predominance in trained animals. Conclusion: Ovariectomy did not change the tonic autonomic control of the heart and, in addition, reduced the participation of sympathetic component in cardiac modulation. Physical training, on the other hand, increased the participation of parasympathetic modulation on the HRV, including ovariectomized rats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two experiments were conducted to investigate the effects of equine chorionic gonadotropin (eCG) at progestin removal and gonadotropin-releasing hormone (GnRH) at timed artificial insemination (TA!) on ovarian follicular dynamics (Experiment 1) and pregnancy rates (Experiment 2) in suckled Nelore (Bos indicus) cows. Both experiments were 2 x 2 factorials (eCG or No eCG, and GnRH or No GnRH), with identical treatments. In Experiment 1, 50 anestrous cows, 134.5 +/- 2.3 d postpartum, received a 3 mg norgestomet ear implant se, plus 3 mg norgestomet and 5 mg estradiol valerate im on Day 0. The implant was removed on Day 9, with TAI 54 h later. Cows received 400 IU eCG or no further treatment on Day 9 and GnRH (100 mu g gonadorelin) or no further treatment at TAI. Treatment with eCG increased the growth rate of the largest follicle from Days 9 to 11 (means +/- SEM, 1.53 +/- 0.1 vs. 0.48 +/- 0.1 mm/d; P < 0.0001), its diameter on Day 11(11.4 +/- 0.6 vs. 9.3 +/- 0.7 mm; P = 0.03), as well as ovulation rate (80.8% vs. 50.0%, P = 0.02), whereas GnRH improved the synchrony of ovulation (72.0 +/- 1.1 VS. 71.1 +/- 2.0 h). In Experiment 2 (n = 599 cows, 40 to 120 d postpartum), pregnancy rates differed (P = 0.004) among groups (27.6%, 40.1%, 47.7%, and 55.7% for Control. GnRH, eCG, and eCG + GnRH groups). Both eCG and GnRH improved pregnancy rates (51.7% vs. 318%, P = 0.002; and 48.0% vs 37.6%, P = 0.02, respectively), although their effects were not additive (no significant interaction). In conclusion, eCG at norgestomet implant removal increased the growth rate of the largest follicle (LF) from implant removal to TAI, the diameter of the LF at TAI, and rates of ovulation and pregnancy rates. Furthermore, GnRH at TAI improved the synchrony of ovulations and pregnancy rates in postpartum Nelore cows treated with a norgestomet-based TAI protocol. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives were to evaluate the effects of equine chorionic gonadotropin (eCG) supplementation (with or without eCG) and type of ovulatory stimulus (GnRH or ECP) on ovarian follicular dynamics, luteal function, and pregnancies per AI (P/AI) in Holstein cows receiving timed artificial insemination (TAI). On Day 0, 742 cows in a total of 782 breedings, received 2 mg of estradiol benzoate (EB) and one intravaginal progesterone (P4) insert (CIDR). On Day 8, the CIDR was removed, and all cows were given PGF2 alpha and assigned to one of four treatments in a 2 x 2 factorial arrangement: (1) CG: GnRH 48 h later; (2) CE: ECP; (3) EG: eCG + GnRH 48 It later; (4) EE: eCG + ECP. There were significant interactions for eCG x ovulatory stimulus and eCG x BCS. Cows in the CG group were less likely (28.9% vs. 33.8%; P < 0.05) to become pregnant compared with those in the EG group (odds ratio [OR] = 0.28). There were no differences in P/AI between CE and EE cows (30.9% vs. 29.1%; OR = 0.85; P = 0.56), respectively. Thinner cows not receiving eCG had lower P/AI than thinner cows receiving eCG (15.2% vs. 38.0%; OR = 0.20; P < 0.01). Treatment with eCG tended to increase serum progestesterone concentrations during the diestrus following synchronized ovulation (P < 0.10). However, the treatment used to induce ovulation did not affect CL volume or serum progesterone concentrations. In conclusion, both ECP and GnRH yielded comparable P/AI. However, eCG treatment at CIDR removal increased pregnancy rate in cows induced to ovulate with GnRH and in cows with lower BCS. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this research was to assess the dimensional accuracy of orbital prostheses based on reversed images generated by computer-aided design/computer-assisted manufacturing (CAD/CAM) using computed tomography (CT) scans. Materials and Methods: CT scans of the faces of 15 adults, men and women older than 25 years of age not bearing any congenital or acquired craniofacial defects, were processed using CAD software to produce 30 reversed three-dimensional models of the orbital region. These models were then processed using the CAM system by means of selective laser sintering to generate surface prototypes of the volunteers` orbital regions. Two moulage impressions of the faces of each volunteer were taken to manufacture 15 pairs of casts. Orbital defects were created on the right or left side of each cast. The surface prototypes were adapted to the casts and then flasked to fabricate silicone prostheses. The establishment of anthropometric landmarks on the orbital region and facial midline allowed for the data collection of 31 linear measurements, used to assess the dimensional accuracy of the orbital prostheses and their location on the face. Results: The comparative analyses of the linear measurements taken from the orbital prostheses and the opposite sides that originated the surface prototypes demonstrated that the orbital prostheses presented similar vertical, transversal, and oblique dimensions, as well as similar depth. There was no transverse or oblique displacement of the prostheses. Conclusion: From a clinical perspective, the small differences observed after analyzing all 31 linear measurements did not indicate facial asymmetry. The dimensional accuracy of the orbital prostheses suggested that the CAD/CAM system assessed herein may be applicable for clinical purposes. Int J Prosthodont 2010;23:271-276.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Objectives: This study evaluated the hybrid layer (HL) morphology created by three adhesive systems (AS) on dentin surfaces treated with Er:YAG laser using two irradiation parameters. Study Design: Occlusal flat dentin surfaces of 36 human third molars were assigned into nine groups (n = 4) according to the following ASs: one bottle etch&rinse Single Bond Plus (3M ESPE), two-step Clearfil Protect Bond (Kuraray), and all-in-one S3 Bond (Kuraray) self-etching, which were labeled with rhodamine B or fluorescein isothiocyanate dextran and were applied to dentin surfaces that were irradiated with Er:YAG laser at either 120 (38.7 J/cm(2)) or 200 mJ/pulse (64.5 J/cm(2)), or were applied to untreated dentin surfaces (control group). The ASs were light-activated following MI and the bonded surfaces were restored with resin composite Z250 (3M ESPE). After 24 hours of storage in vegetable oil, the restored teeth were vertically, serially sectioned into 1-mm thick slabs, which had the adhesive interfaces analyzed with confocal laser microscope (CLSM-LSM 510 Meta). CLSM images were recorded in the fluorescent mode from three different regions along each bonded interface. Results: Non-uniform HL was created on laser-irradiated dentin surfaces regardless of laser irradiation protocol for all AS, while regular and uniform HL was observed in the control groups. ""Stretch mark""-like red lines were found within the HL as a result of resin infiltration into dentin microfissures, which were predominantly observed in 200 mJ/pulse groups regardless of AS. Poor resin infiltration into peritubular dentin was observed in most regions of adhesive interfaces created by all ASs on laser-irradiated dentin, resulting in thin resin tags with neither funnel-shaped morphology nor lateral resin projections. Conclusion: Laser irradiation of dentin surfaces at 120 or 200 mJ/pulse resulted in morphological changes in HL and resin tags for all ASs evaluated in the study. Lasers Surg. Med. 42:662-670, 2010. (C) 2010 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to assess the influence of adhesive area delimitation on the microshear bond strength of different adhesives to dentin. Materials and Methods: Eighteen bovine incisors were sectioned and the exposed dentin surfaces were prepared with 600-grit SIC paper. These teeth were randomly divided into three groups, according to the adhesive to be applied: two-step etch-and-rinse Adper Single Bond 2 (3M ESPE), two-step self-etching Clearfil SE Bond (Kuraray), and one-step Clearfil S(3) Bond (Kuraray). On each dentin surface, 4 samples were built up with the composite resin Z100 (3M ESPE); on 2 of these, a suggested area delimitation technique was employed. After 24 h of storage in water at 37 degrees C, samples were subjected to the microshear bond strength test, and the failure modes were evaluated under optical and scanning electron microscopes. The obtained results were statistical analyzed using two-way ANOVA and Tukey`s test. Results: Groups without area delimitation presented significantly higher bond strength results (p < 0.05) and a higher incidence of cohesive failures. In these groups, fractures tended to occur beyond the limits of the actual adhesive area, while the area restriction technique succeeded in avoiding this phenomenon. The three adhesives performed similarly when area delimitation was employed (p > 0.05), but Clearfil S(3) Bond showed significantly higher bond strength results when no area delimitation was taken into account (p < 0.05). Conclusion: The extension of the adhesive area beyond the limits of the composite cylinder may play an important role in the results of microshear bond strength tests, while the suggested area delimitation technique may lead to less questionable outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research evaluated the effects of Branemark protocol on electromyography of the masseter and temporal muscles. The patients were divided into two groups: Group 1: patients who wore an implant-supported prosthesis in the mandibular arch following Branemark protocol, and maxillary removable complete dentures; Group II: dentate individuals (control). Electromyography was carried out at rest, right (RL) and left (LL) laterality, protrusion and maximum voluntary contraction (MVC). Data were compared by t-test. At rest, a higher electromyographic (EMG) activity was observed in Group I, and the values were significant in the right masseter and left temporal muscles. In RL, there were statistically significant differences for right masseter (P < 0.01), left masseter and temporal muscles and for the left temporal muscle in LL (P < 0.05). In protrusion, Group I presented a higher EMG activity, and there was a statistically significant difference for the right masseter muscle (RM) (P < 0.05). In MVC, the EMG values were higher in Group II (control), but significant just for the right temporal muscle (P < 0.05). In conclusion, individuals with mandibular fixed dentures supported according to the Branemark protocol and maxillary removable complete dentures showed a higher activity of masticatory muscles during the mandibular postural clinical conditions examined; however, in the MVC, Group I presented lower values when compared to dentate group. Despite presenting different EMG values in all of the clinical conditions, both groups showed similar EMG patterns of muscle activation which demonstrates that the proposed treatment can be considered as a good option for oral rehabilitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of light guide distance and the different photoactivation methods on the degree of conversion (DC) and microleakage of a composite. Methods and Materials: Three photoactivation protocols (600mW/cm(2) x 40 seconds; 400 mW/cm(2) x 60 seconds or 200 mW/cm(2) x 20 seconds, followed by 500 mW/cm(2) X 40 seconds) and three distances from the light source (0, 3 or 7 mm) were tested. Cylindrical specimens (5 nun diameter; 2 mm tall; n=3) were prepared for the DC test (FT-Raman). Class V cavities were made in 90 bovine incisors to conduct the microleakage test. The specimens were conditioned for 15 seconds with phosphoric acid (37%), followed by application of the adhesive system Prime & Bond NT (Dentsply/Caulk). The preparations were restored in bulk. The specimens were stored for 24 hours in distilled water (37 degrees C) before being submitted to the silvernitrate microleakage protocol. The restorations were sectioned and analyzed under 25x magnification. Results: Statistical analyses (two-way ANOVAs and Tukey test, alpha=0.05) found significance only for the factor distance (p=0.015) at the top of the composite for the DC test. Conversion was statistically lower for the 7 mm groups compared to the 0 and 3 mm groups, which were equivalent to each other. At the bottom of the specimens, none of the factors or interactions was significant (p<0.05). The Kruskal-Wallis test showed that, in general, the soft-start method led to lower microleakage scores when compared to the continuous modes, mainly when associated with a distancing of 7 mm (p<0.01). With the exception of specimens irradiated with 400mW/cm(2) that did not demonstrate variations on scores for the distances tested, higher microleakage was observed for shorter distances from the light source. Conclusions: Soft-start methods may reduce microleakage when the light guide distancing provides a low level of irradiance, which also causes a discrete reduction in the DC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Detection and quantification of human papillomavirus (HPV) may help in predicting the evolution of HPV infection and progression of associated lesions. Objectives: We propose a novel protocol using consensus primers GP5+/6+ in a SYBR Green quantitative real-time (Q-RT) polymerase chain reaction (PCR). The strategy permits screening for HPV infection and viral load quantification simultaneously. Study design: DNA from 153 archived cervical samples, previously tested for HPV detection by GP5+/6+ PCR and typed by EIA-RLB (enzyme immunoassay-reverse line blot) or sequence analysis, was analysed using SYBR Green Q-RT PCR. Melting temperature assay (T(m)) and cycle threshold (C(t)) were used to evaluate HPV positivity and viral load. The T(m) in the range of 77-82 degrees C was considered to be positive for HPV-DNA. HPV results generated through GP5+/6+ conventional PCR were considered the gold standard against which sensitivity and specificity of our assay were measured. Results: Out of 104 HPV positive samples, 100 (96.2%) were also determined as positive by SYBR Green Q-RT PCR; of the 49 HPV-negative samples, all were determined as negative. There was an excellent positivity agreement (K = 0.94) between the SYBR Green Q-RT and the previous methods employed. The specificity and sensitivity were 100% and 96.2%, respectively. Comparison of SYBR Green Q-RT and TaqMan oligo-probe technologies gave an excellent concordance (pc = 0.95) which validated the proposed strategy. Conclusions: We propose a sensitive and easy-to-perform technique for HPV screening and viral load quantification simultaneously. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. The purpose of this study was to evaluate how curing protocol affects the extent of polymerization of dual-cured resin cements. Methods. Four commercial resin cements were used (DuoLink, Panavia F 2.0, Variolink II and Enforce). The extent of polymerization of the resin cements cured under different conditions was measured using a (1)H Stray-Field MRI method, which also enabled to probe molecular mobility in the kHz frequency range. Results. Resin cements show well distinct behaviours concerning chemical cure. Immediate photo-activation appears to be the best choice for higher filler loaded resin cements (Panavia F 2.0 and Variolink). A photo-activation delay (5 min) did not induce any significant difference in the extent of polymerization of all cements. Significance. The extent of polymerization of dual-cured resin cements considerably changed among products under various curing protocols. Clinicians should optimize the materials choice taking into account the curing characteristics of the cements. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of framework design on the fracture resistance of metal-ceramic implant-supported crowns. Screw-retained molar crowns with a screw access hole composed of metal or porcelain were compared to a cement-retained crown (control). For each group (n = 10), five crowns were subjected to dynamic loading (1,200,000 x 100 N x 2 Hz at 37 degrees C). Afterward, all specimens were loaded to failure using a universal testing machine. Significant differences could be established between the cement-and screw-retained groups (P <= .05), but no difference was found between the screw-retained groups and the specimens subjected to dynamic loading. Occlusal discontinuity of screw-retained crowns affects their resistance, and the metallic support on the screw access hole did not reinforce the crowns. Int J Prosthodont 2010;23:350-352.