832 resultados para Producao agricola
Resumo:
Craniosynostosis syndromes are characterized by premature closure of one or more cranial sutures, associated with other malformations, the most frequent of which are the Crouzon and Apert syndromes. Few studies in the literature have addressed the oral health of these individuals. The purpose of this study was to compare the periodontal status of individuals with Apert, Crouzon, Pfeiffer and Saethre-Chotzen syndromes before toothbrushing and compare the efficiency of plaque removal before and after mechanical toothbrushing. The probing depth, plaque index (according to Löe and O'Leary), clinical attachment level, gingival index (according to Silness and Löe) and amount of keratinized mucosa were evaluated before toothbrushing, and the O'Leary plaque index was assessed before and immediately after toothbrushing, on the same day, in 27 individuals aged 11 to 36 years. There was statistically significant difference in the mean probing depth and clinical attachment level among regions (p=0.00; p=0.01, respectively). The gingival index did not reveal statistically significant differences. With regard to the plaque index, the left region exhibited higher plaque index values than the right and anterior regions. No significant results were found in the analysis of keratinized mucosa. Comparison of the O'Leary plaque index before and after toothbrushing revealed statistically significant difference for all syndromes except for the Pfeiffer syndrome (p<0.05). In conclusion, there was no difference in the periodontal status among individuals with syndromic craniosynostosis. The posterior region was more affected than the anterior region as to the presence of plaque, loss of insertion and probing depth. Individuals with Pfeiffer syndrome exhibited greater toothbrushing efficiency than individuals with the other craniosynostosis syndromes.
Resumo:
The wear resistance of denture teeth is important to the longevity of removable prostheses of edentulous patients. The ability of denture teeth to maintain a stable occlusal relationship over time may be influenced by this property. The purpose of this in vitro study was to evaluate the wear resistance of polymethyl methacrylate (PMMA) denture teeth based on their chemical composition when opposed by a ceramic antagonist. The maxillary canines (n=10) of 3 PMMA denture teeth (Trubyte Biotone, cross-linked PMMA; Trilux, highly cross-linked IPN (interpenetrating polymer network)-PMMA; and Vivodent, highly cross-linked PMMA) were secured in an in vitro 2-body wear-testing apparatus that produced sliding contact of the specimens (4.5 cycles/s, sliding distance of 20 mm, under 37°C running water) against glazed or airborne particle abraded ceramic. Wear resistance was measured as height loss (mm) under 300 g (sliding force) after 100,000 cycles, using a digital measuring microscope. Mean values were analyzed by 2-way ANOVA and Tukey's test (a=0.05). The wear of Trubyte Biotone (0.93 ± 0.14 mm) was significantly higher than that of both other types of teeth tested against abraded ceramic (p<0.05). The Vivodent tooth (0.64 ± 0.17 mm) exhibited the best wear resistance among the denture teeth tested against airborne particle abraded ceramic. There were no statistically significant differences (p>0.05) in wear among the 3 denture teeth evaluated against glazed ceramic. Trilux and Vivodent teeth tested against either glazed or airborne particle abraded ceramic did not differ significantly from each other (p<0.05). All teeth showed significantly more wear against airborne particle abraded ceramic than against glazed ceramic (p<0.05). In conclusion, the three types of PMMA denture teeth presented significantly different wear resistance against the abraded ceramic. The high-strength PMMA denture teeth were more wear-resistant than the conventional PMMA denture tooth.
Resumo:
In long-term oral rehabilitation treatments, resistance of provisional crowns is a very important factor, especially in cases of an extensive edentulous distal space. The aim of this laboratorial study was to evaluate an acrylic resin cantilever-type prosthesis regarding the flexural strength of its in-balance portion as a function of its extension variation and reinforcement by two types of fibers (glass and polyaramid), considering that literature is not conclusive on this subject. Each specimen was composed by 3 total crowns at its mesial portion, each one attached to an implant component (abutment), while the distal portion (cantilever) had two crowns. Each specimen was constructed by injecting acrylic resin into a two-part silicone matrix placed on a metallic base. In each specimen, the crowns were fabricated with either acrylic resin (control group) or acrylic resin reinforced by glass (Fibrante, Angelus) or polyaramide (Kevlar 49, Du Pont) fibers. Compression load was applied on the cantilever, in a point located 7, 14 or 21 mm from the distal surface of the nearest crown with abutment, to simulate different extensions. The specimen was fixed on the metallic base and the force was applied until fracture in a universal test machine. Each one of the 9 sub-groups was composed by 10 specimens. Flexural strength means (in kgf) for the distances of 7, 14 and 21 mm were, respectively, 28.07, 8.27 and 6.39 for control group, 31.89, 9.18 and 5.16 for Kevlar 49 and 30.90, 9.31 and 6.86 for Fibrante. Data analysis ANOVA showed statistically significant difference (p<0.05) only regarding cantilever extension. Tukey's test detected significantly higher flexural strength for the 7 mm-distance, followed by 14 and 21 mm. Fracture was complete only on specimens of non-reinforced groups.
Correlation between margin fit and microleakage in complete crowns cemented with three luting agents
Resumo:
Microleakage can be related to margin misfit. Also, traditional microleakage techniques are time-consuming. This study evaluated the existence of correlation between in vitro margin fit and a new microleakage technique for complete crowns cemented with 3 different luting agents. Thirty human premolars were prepared for full-coverage crowns with a convergence angle of 6 degrees, chamfer margin of 1.2 mm circumferentially, and occlusal reduction of 1.5 mm. Ni-Cr cast crowns were cemented with either zinc phosphate (ZP) (S.S. White), resin-modified glass-ionomer (RMGI) (Rely X Luting Cement) or a resin-based luting agent (RC) (Enforce). Margin fit (seating discrepancy and margin gap) was evaluated according to criteria in the literature under microscope with 0.001 mm accuracy. After thermal cycling, crowns were longitudinally sectioned and microleakage scores at tooth-cement interface were obtained and recorded at ×100 magnification. Margin fit parameters were compared with the one-way ANOVA test and microleakage scores with Kruskal-Wallis and Dunn's tests (alpha=0.05). Correlation between margin fit and microleakage was analyzed with the Spearman's test (alpha=0.05). Seating discrepancy and marginal gap values ranged from 81.82 µm to 137.22 µm (p=0.117), and from 75.42 µm to 78.49 µm (p=0.940), respectively. Marginal microleakage scores were ZP=3.02, RMGI=0.35 and RC=0.12 (p<0.001), with no differences between RMGI and RC scores. The correlation coefficient values ranged from -0.27 to 0.30 (p>0.05). Conclusion: Margin fit parameters and microleakage showed no strong correlations; cast crowns cemented with RMGI and RC had lower microleakage scores than ZP cement.
Resumo:
O Termo do 1º Consenso em Disfunção Temporomandibular e Dor Orofacial* foi criado com o propósito de substituir divergências por evidência científica dentro dessa especialidade da Odontologia. O documento oferece informações claras e fundamentadas para orientar o cirurgião-dentista e demais profissionais de saúde sobre os cuidados demandados pelo paciente, tanto no processo de diagnóstico diferencial quanto na fase de aplicação das terapias de controle da dor e disfunção. O Termo foi aprovado no mês de janeiro de 2010 em reunião realizada durante o Congresso Internacional de Odontologia do Estado de São Paulo e converge o pensamento dos profissionais mais conceituados do Brasil na especialidade Disfunção Temporomandibular e Dor Orofacial.
Resumo:
Dental impression is an important step in the preparation of prostheses since it provides the reproduction of anatomic and surface details of teeth and adjacent structures. The objective of this study was to evaluate the linear dimensional alterations in gypsum dies obtained with different elastomeric materials, using a resin coping impression technique with individual shells. A master cast made of stainless steel with fixed prosthesis characteristics with two prepared abutment teeth was used to obtain the impressions. References points (A, B, C, D, E and F) were recorded on the occlusal and buccal surfaces of abutments to register the distances. The impressions were obtained using the following materials: polyether, mercaptan-polysulfide, addition silicone, and condensation silicone. The transfer impressions were made with custom trays and an irreversible hydrocolloid material and were poured with type IV gypsum. The distances between identified points in gypsum dies were measured using an optical microscope and the results were statistically analyzed by ANOVA (p < 0.05) and Tukey's test. The mean of the distances were registered as follows: addition silicone (AB = 13.6 µm, CD=15.0 µm, EF = 14.6 µm, GH=15.2 µm), mercaptan-polysulfide (AB = 36.0 µm, CD = 36.0 µm, EF = 39.6 µm, GH = 40.6 µm), polyether (AB = 35.2 µm, CD = 35.6 µm, EF = 39.4 µm, GH = 41.4 µm) and condensation silicone (AB = 69.2 µm, CD = 71.0 µm, EF = 80.6 µm, GH = 81.2 µm). All of the measurements found in gypsum dies were compared to those of a master cast. The results demonstrated that the addition silicone provides the best stability of the compounds tested, followed by polyether, polysulfide and condensation silicone. No statistical differences were obtained between polyether and mercaptan-polysulfide materials.
Resumo:
This study investigated the effects of the cement type and the water storage time on the push-out bond strength of a glass fiber post. Glass fiber posts (Fibrekor, Jeneric Pentron) were luted to post spaces using a self-cured resin cement (C&B Cement [CB]), a glass ionomer cement (Ketac Cem [KC]) or a resin-modified glass ionomer cement (GC FujiCEM [FC]) according to the manufacturers’ instructions. For each luting agent, the specimens were exposed to one of the following water storage times (n=5): 1 day (T1), 7 days (T7), 90 days (T90) and 180 days (T180). Push-out tests were performed after the storage times. Control specimens were not exposed to water storage, but subjected to the push-out test 10 min after post cementation. Data (in MPa) were analyzed by Kruskal-Wallis and Dunn`s test (α=0.05). Cement type and water storage time had a significant effect (p<0.05) on the push-out bond strength. CB showed significantly higher values of retention (p<0.05) than KC and FC, irrespective of the water storage time. Water storage increased significantly the push-out bond strength in T7 and T90, regardless of the cement type (p<0.05). The results showed that fiber posts luted to post spaces with the self-cured resin cement exhibited the best bonding performance throughout the 180-day water storage period. All cements exhibited a tendency to increase the bond strength after 7 and 90 days of water storage, decreasing thereafter.
Resumo:
The aim of this study was to investigate the fracture strength of endodontically treated teeth restored with different posts and variable ferrule heights. Sixty freshly extracted human canines were treated endodontically and randomly assigned to 6 groups (n=10), being restored with custom-made cast post-and-core (CP0 and CP3 groups), prefabricated post and composite resin core (PF0 and PF3 groups), and composite resin (CR0 and CR3 groups). The CP0, PF0 and CR0 groups presented no ferrule and the CP3, PF3 and CR3 presented 3 mm of coronal structure. All teeth were restored with full metal crowns. The fracture strength was measured in a universal testing machine at 45o to the long axis of the tooth until failure. Data were analyzed statistically by 2-way ANOVA and Tukey's test (?=0.05). When the mean fracture strength values were compared (CP0 group - 820.20 N, CP3 group - 1179.12 N; PF0 group - 561.05 N; PF3 group - 906.79 N; CR0 group - 297.84 N; and CR3 group - 1135.15 N) there was statistically significant among the groups (p<0.05), except for the three groups with 3 mm of coronal remaining, which were similar to each other. The results of this study showed that the ferrule in crowns promoted significantly higher fracture strength in the endodontically treated teeth.
Resumo:
OBJETIVO: esta revisão de literatura visa avaliar, através de literatura específica, a sensibilidade e especificidade do exame de ressonância magnética (RM) para o diagnóstico dos desarranjos internos da articulação temporomandibular (ATM). METODOLOGIA: tanto artigos que utilizaram ATM de cadáveres para comparar achados anatômicos aos achados de ressonância magnética (RM), como artigos que compararam achados clínicos com achados de RM foram utilizados. Através dos achados desses artigos, as propriedades de sensibilidade e especificidade da RM para o diagnóstico de desarranjos internos da ATM foram calculadas. Com isso, a confiabilidade e a aplicabilidade do exame de RM no diagnóstico dos desarranjos internos da ATM foram discutidas. RESULTADOS: encontrou-se sensibilidade de 90% e especificidade de 88% da RM para desarranjos internos da ATM. CONCLUSÃO: o exame de RM de ATM possui ótima sensibilidade e especificidade para o diagnóstico dos desarranjos internos da ATM. Porém, tal exame deve ser solicitado com cautela, apenas nos casos onde a imagem seja indispensável para o plano de tratamento.
Resumo:
This study evaluated the fracture resistance of weakened roots restored with glass fiber posts, composite resin cores and complete metal crowns. Thirty maxillary canines were randomly divided into 3 groups of 10 teeth each: teeth without weakened roots (control); teeth with partially weakened roots (PWR) and teeth with and largely weakened roots (LWR). The control group was restored with glass fiber posts and a composite resin core. Teeth in the PWR and LWR groups were flared internally to standardized dimensions in order to simulate root weakness. Thereafter, the roots were partially filled with composite resin and restored in the same way as in the control group. The specimens were exposed to 250,000 cycles in a controlled chewing simulator. All intact specimens were subjected to a static load (N) in a universal testing machine at 45 degrees to the long axis of the tooth until failure. Data were analyzed by one-way ANOVA and Dunnett's test for multiple comparisons (p=0.05). There were statistically significant difference differences (p<0.01) among the groups (control group = 566.73 N; PWR = 409.64 N; and LWR = 410.91 N), with significantly higher fracture strength for the control group. There was no statistically significant difference (p>0.05) between the weakened groups. The results of this study showed that thicker root dentin walls significantly increase the fracture resistance of endodontically treated teeth.
Resumo:
A recomendação da Organização Mundial da Saúde é que todo recém nascido deva ser alimentado exclusivamente no seio materno até o sexto mês e, de forma complementar, até o segundo ano de vida. Assim, algumas técnicas são realizadas para facilitar a alimentação ao seio, dentre elas o uso do copo e, recentemente, a utilização da técnica "sonda-dedo". Tal prática é bastante controversa e há escassez de estudos na literatura sobre a descrição da técnica, sua indicação e uso. O objetivo do presente trabalho é relatar a experiência clínica para indicação e uso da técnica "sonda-dedo". A técnica "sonda-dedo" consiste no oferecimento do leite, de preferência humano, utilizando sonda gástrica conectada a uma seringa com êmbolo e fixada em dedo mínimo enluvado com fita adesiva. A sonda é posicionada na cavidade oral do recém nascido e deve servir como uma técnica de auxílio para adequação do padrão de sucção. Desta forma, sugere-se que sua indicação deve ser apenas nos casos em que seja caracterizada uma disfunção oral, seja em recém nascidos a termo ou pré-termo. Diante da avaliação específica, realizada pelo fonoaudiólogo, indica-se a técnica "sonda-dedo" com objetivo de adequar as alterações obtidas na avaliação da sucção não nutritiva ou em seio materno. Acredita-se que, para que a técnica "sonda-dedo" seja indicada como complemento do aleitamento materno, devam ser realizados novos estudos para esclarecer quais as repercussões da técnica "sonda-dedo" na prevalência do aleitamento materno e no desenvolvimento motor oral de recém nascidos.
Resumo:
TEMA: a produção da fala nas modalidades de reabilitação oral protética. OBJETIVO: verificar se o tipo de reabilitação oral interfere na produção da fala. MÉTODO: 36 idosos (média = 68 anos), divididos em 3 grupos, foram avaliados: 13 com dentes naturais (A), 13 com prótese total mucosossuportada superior e inferior (B) e 10 com prótese total mucosossuportada superior e implantossuportada inferior (C). A estabilidade das próteses foi avaliada por um dentista e amostras de fala foram analisadas por 5 fonoaudiólogos. Para determinar a freqüência de alteração dos sons da fala utilizou-se o cálculo da Porcentagem de Consoantes Corretas (PCC). RESULTADOS: observou-se poucos casos com alteração de fala, com maior freqüência no grupo C (23,08%), sendo a articulação travada presente em todos os grupos, a redução dos movimentos labiais em dois grupos (A e B) e a articulação exagerada e a falta de controle salivar em um dos grupos (C e B). Quanto à PCC, menor valor foi observado para os fones linguodentais nos grupos B e C (maior ocorrência de alteração), seguido dos fones alveolares, predominando casos sem alteração no grupo A, contrariamente aos demais grupos, sendo a projeção lingual e o ceceio as alterações mais encontradas. Não houve diferença entre os grupos e a maioria do grupo B estava com a prótese inferior insatisfatória, não havendo associação entre alteração de fala e prótese insatisfatória. CONCLUSÃO: apesar da amostra pequena, indivíduos reabilitados com prótese total apresentam alteração nos fones linguodentais e alveolares e o tipo de prótese, bem como a estabilidade desta parece não interferir na produção da fala.
Resumo:
Dental roots that have been exposed to the oral cavity and periodontal pocket environment present superficial changes, which can prevent connective tissue reattachment. Demineralizing agents have been used as an adjunct to the periodontal treatment aiming at restoring the biocompatibility of roots. OBJECTIVE: This study compared four commonly used demineralizing agents for their capacity of removing smear layer and opening dentin tubules. METHODS: Fifty fragments of human dental roots previously exposed to periodontal disease were scaled and randomly divided into the following groups of treatment: 1) CA: demineralization with citric acid for 3 min; 2) TC-HCl: demineralization with tetracycline-HCl for 3 min; 3) EDTA: demineralization with EDTA for 3 min; 4) PA: demineralization with 37% phosphoric acid for 3 min; 5) Control: rubbing of saline solution for 3 min. Scanning electron microscopy was used to check for the presence of residual smear layer and for measuring the number and area of exposed dentin tubules. RESULTS: Smear layer was present in 100% of the specimens from the groups PA and control; in 80% from EDTA group; in 33.3% from TC-HCl group and 0% from CA group. The mean numbers of exposed dentin tubules in a standardized area were: TC-HCl=43.8±25.2; CA=39.3±37; PA=12.1±16.3; EDTA=4.4±7.5 and Control=2.3±5.7. The comparison showed significant differences between the following pairs of groups: TC-HCl and Control; TC-HCl and EDTA; CA and Control; and CA and EDTA. The mean percentages of area occupied by exposed dentin tubules were: CA=0.12±0.17%; TC-HCl=0.08±0.06%; PA=0.03±0.05%; EDTA=0.01±0.01% and Control=0±0%. The CA group differed significantly from the others except for the TC-HCl group. CONCLUSION: There was a decreasing ability for smear layer removal and dentin tubule widening as follows: AC>TC-HCl>PA>EDTA. This information can be of value as an extra parameter for choosing one of them for root conditioning.
Resumo:
OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, frequently hinder the development of clinical trials. The purpose of this in vitro study was to determine the modulus of elasticity of a polyurethane isotropic experimental model via tension tests, comparing the results to those reported in the literature for mandibular bone, in order to validate the use of such a model in lieu of mandibular bone in biomechanical studies. MATERIAL AND METHODS: Forty-five polyurethane test specimens were divided into 3 groups of 15 specimens each, according to the ratio (A/B) of polyurethane reagents (PU-1: 1/0.5, PU-2: 1/1, PU-3: 1/1.5). RESULTS: Tension tests were performed in each experimental group and the modulus of elasticity values found were 192.98 MPa (SD=57.20) for PU-1, 347.90 MPa (SD=109.54) for PU-2 and 304.64 MPa (SD=25.48) for PU-3. CONCLUSION: The concentration of choice for building the experimental model was 1/1.
Resumo:
OBJECTIVES: The aim of this study was to evaluate the effects of non-surgical treatment of periodontal disease during the second trimester of gestation on adverse pregnancy outcomes. MATERIAL AND METHODS: Pregnant patients during the 1st and 2nd trimesters at antenatal care in a Public Health Center were divided into 2 groups: NIG - "no intervention" (n=17) or IG- "intervention" (n=16). IG patients were submitted to a non-surgical periodontal treatment performed by a single periodontist consisting of scaling and root planning (SRP), professional prophylaxis (PROPH) and oral hygiene instruction (OHI). NIG received PROPH and OHI during pregnancy and were referred for treatment after delivery. Periodontal evaluation was performed by a single trained examiner, blinded to periodontal treatment, according to probing depth (PD), clinical attachment level (CAL), plaque index (PI) and sulcular bleeding index (SBI) at baseline and 35 gestational weeks-28 days post-partum. Primary adverse pregnancy outcomes were preterm birth (<37 weeks), low birth weight (<2.5 kg), late abortion (14-24 weeks) or abortion (<14 weeks). The results obtained were statistically evaluated according to OR, unpaired t test and paired t test at 5% signifcance level. RESULTS: No signifcant differences were observed between groups at baseline examination. Periodontal treatment resulted in stabilization of CAL and PI (p>0.05) at IG and worsening of all periodontal parameters at NIG (p<0.0001), except for PI. Signifcant differences in periodontal conditions of IG and NIG were observed at 2nd examination (p<0.001). The rate of adverse pregnancy outcomes was 47.05% in NIG and 6.25% in IG. Periodontal treatment during pregnancy was associated to a decreased risk of developing adverse pregnancy outcomes [OR=13.50; CI: 1.47-123.45; p=0.02]. CONCLUSIONS: Periodontal treatment during the second trimester of gestation contributes to decrease adverse pregnancy outcomes.