106 resultados para Lumbar stabilization
Resumo:
Goal: To describe clinical and laboratory features of human immunodeficiency infection (HIV)-infected patients with neurosyphilis. Study Design: Retrospective study of 27 consecutive cases of HIV-infected patients with a positive Venereal Disease Research Laboratory (VDRL) in cerebrospinal fluid (CSF). Results: Median of age was 36 years and 89% were men. Ten (37%) patients had previous nonneurologic syphilis treatment. At the time of neurosyphilis diagnosis, 10 (37%) patients had early syphilis, and 6 of them were neurologically asymptomatic. Nine (33%) patients had symptomatic neurosyphilis. Twenty-six (96%) patients were classified with early neurosyphilis. The medians of serum VDRL and CD4(+) T cell counts were 1:128 and 182 cell/mu L, respectively. Twenty five (93%) patients presented serum VDRL titers >= 1:16. Five of 6 patients with early syphilis and asymptomatic neurosyphilis, presented serum VDRL >= 1:16. Symptomatic patients showed lower CD4(+) T cell counts (59 cell/mu L vs. 208 cell/mu L, P = 0.03) and higher protein concentration on CSF (118 mg/dL vs. 39 mg/dL, P <0.001) than asymptomatic patients. Conclusions: Most patients had early and asymptomatic neurosyphilis, and more than one third had early syphilis. Patients with symptomatic neurosyphilis showed lower CD4(+) T cell counts and higher protein concentration on CSF than those asymptomatic. Most patients had serum VDRL titers >= 1:16, regardless of syphilis stage.
Resumo:
Objective: To assess the ability of a three-layer graft in the closuse of large fetal skin defects. Methods: Ovine fetuses underwent a large (4 x 3 cm) full-thickness skin defect over the lumbar region at 105 days` gestation (term = 140 days). A bilaminar artificial skin was placed over a cellulose interface to cover the defect (3-layer graft). The skin was partially reapproximated with a continuous nylon suture. Pregnancy was allowed to continue and the surgical site was submitted to histopathological analysis at different post-operative intervals. Results: Seven fetuses underwent surgery. One maternal/fetal death occurred, and the remaining 6 fetuses were analyzed. Artificial skin adherence to the wound edges was observed in cases that remained in utero for at least 15 days. Neoskin was present beneath the silicone layer of the bilaminar artificial skin. Conclusions: Our study shows that neoskin can develop in the fetus using a 3-layer graft, including epidermal growth beneath the silicone layer of the bilaminar skin graft. These findings suggest that the fetus is able to reepithelialise even large skin defects. Further experience is necessary to assess the quality of this repair.
Resumo:
Introduction: The vertebrae fixation system using pedicular screws is one of the most efficient methods to treat vertebral spine pathologies. When the screw is submitted to pullout strength, it causes internal tension near the medullar canal and this situation can be analyzed by using the photoelasticity technique. Objective: Were analyzed those internal tensions near the medullar canal of photoelastic vertebra models using different sizes of screws of the vertebral fixation system submitted to pullout strength. Methods: A lumbar vertebral model made of photoelastic material with three different USS1-type pedicular screw sizes (5, 6, and 7 mm) was used. The internal tensions around the screw were tested in 12 predetermined points by a plain transmission polaroscope. Results: The areas of greater tension concentration were between the medullar canal and the curves of the transverse process. Comparing the maximum average pulling tension, statistical differences were observed between screws 5 and 7, and 6 and 7. On the other hand, for screws 5 and 6, there were no significant differences. Conclusion: The study evidenced that the internal tensions are greater in irregular areas, next to the medullar canal, showing that this is a critical region.
Resumo:
Background. A variety of techniques can be used to achieve stabilization of femoral valgus osteotomies in children, but what is lacking is a versatile fixation system that associates stability and versatility at different ages and for different degrees of deformity. Methods. Mechanical tests of three configurations used to fix femoral valgus osteotomies, based oil the tension band wire principle, were carried out. A 30 degrees wedge valgus osteotomy was performed at the subtrochanteric level in 60 swine femurs and fixed with three different systems. In Group 1, two Kirschner wires (K wire) were introduced from the tip of the greater trochanter to the medial cortex, crossing the osteotomy. A flexible steel wire was anchored to the K wires into holes in the lateral cortex and tightened to form a tension band. The same setup was used in Group 2, but two additional smooth K wires were inserted into the lateral surface of the greater trochanter and driven to the femoral head with the distal extremities bent and tied around tile bone shaft. In Group 3, the fixation was similar to that in Group 2, but tile ascending K wires were introduced below the osteotomy level, crossing the osteotonly. Mechanical tests in bending-compression and torsion were used to access the stability. Findings. The torsional relative stiffness was 116% greater for Group 3 (0.27 N m/degree) and no significant difference was found between Group 1 (0.10 N m/degree) and Group 2 (0.12 N m/degree). The average torque was 103% higher for Group 3 (1.86 N m). Stiffness in bending-compression was significantly higher in Group 3 (508 x 10(3) N/m) than in Group 1 (211 x 10(3) N/m) and Group 2 (219 x 10(3) N/m). Interpretation. Fixation as used in Group 3 was significantly more stable, both in torsion and bending-compression tests, than tile other two techniques. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
In adolescent idiopathic scoliosis (AIS) there has been a shift towards increasing the number of implants and pedicle screws, which has not been proven to improve cosmetic correction. To evaluate if increasing cost of instrumentation correlates with cosmetic correction using clinical photographs. 58 Lenke 1A and B cases from a multicenter AIS database with at least 3 months follow-up of clinical photographs were used for analysis. Cosmetic parameters on PA and forward bending photographs included angular measurements of trunk shift, shoulder balance, rib hump, and ratio measurements of waist line asymmetry. Pre-op and follow-up X-rays were measured for coronal and sagittal deformity parameters. Cost density was calculated by dividing the total cost of instrumentation by the number of vertebrae being fused. Linear regression and spearman`s correlation were used to correlate cost density to X-ray and photo outcomes. Three independent observers verified radiographic and cosmetic parameters for inter/interobserver variability analysis. Average pre-op Cobb angle and instrumented correction were 54A degrees (SD 12.5) and 59% (SD 25) respectively. The average number of vertebrae fused was 10 (SD 1.9). The total cost of spinal instrumentation ranged from $6,769 to $21,274 (Mean $12,662, SD $3,858). There was a weak positive and statistically significant correlation between Cobb angle correction and cost density (r = 0.33, p = 0.01), and no correlation between Cobb angle correction of the uninstrumented lumbar spine and cost density (r = 0.15, p = 0.26). There was no significant correlation between all sagittal X-ray measurements or any of the photo parameters and cost density. There was good to excellent inter/intraobserver variability of all photographic parameters based on the intraclass correlation coefficient (ICC 0.74-0.98). Our method used to measure cosmesis had good to excellent inter/intraobserver variability, and may be an effective tool to objectively assess cosmesis from photographs. Since increasing cost density only improves mildly the Cobb angle correction of the main thoracic curve and not the correction of the uninstrumented spine or any of the cosmetic parameters, one should consider the cost of increasing implant density in Lenke 1A and B curves. In the area of rationalization of health care expenses, this study demonstrates that increasing the number of implants does not improve any relevant cosmetic or radiographic outcomes.
Resumo:
Study Design. Prospective clinical electromyographic study in adolescents with idiopathic scoliosis and control group. Objective. To evaluate electromyographic amplitude from erector spinae muscles of patients with idiopathic scoliosis in comparison with control volunteers without spinal deformities. Summary of Background Data. Previous studies have indicated an increased electromyographic activity in paravertebral muscles in the convex side of the scoliotic curvature. However, in previous studies there is the absence or poor description of methods used, and some studies were conducted before the recording and processing recommendations for surface electromyographic signals had been described. Methods. Thirty individuals, matched by sex, age, and body mass index, were divided into two groups: scoliosis and control. The electric activity of the erector spinae muscles was determined by surface electromyography on both sides of the three levels of spine: T8, L2, and L5. Results. Normalized electromyographic amplitudes of erector spinae muscles, in the convex and concave sides of the apex region of the scoliotic curve in the thoracic and lumbar regions, were not significantly different. Also, there was no significant difference between the muscles of these regions when the scoliosis group was compared with the control group. The erector spinae muscle at the L5 level, representing the lower vertebral limit of the lumbar scoliotic curve, had significantly higher electromyographic activity on the convex side. However, the same alteration was shown in the control group homologous muscle (on the left side). Conclusion. Erector spinae muscles on the convex and concave sides at the curvature apex in patients with idiopathic scoliosis and small magnitude of curves did not show significant differences in electromyographic amplitude. Future studies should evaluate whether intragroup activation differences, at the L5 level in 80% of the maximum voluntary isometric contractions with predominance of the left side of the vertebral column, have any relation to the condition.
Resumo:
Background: A DNA vaccine (pVAXhsp65) containing the gene of a heat-shock protein (hsp65) from Mycobacterium leprae showed high immunogenicity and protective efficacy against tuberculosis in BALB/c mice. A possible deleterious effect related to autoimmunity needed to be tested because hsp65 is highly homologous to the correspondent mammalian protein. In this investigation we tested the effect of a previous immunization with DNAhsp65 in the development of experimental autoimmune encephalomyelitis (EAE), a rat model of multiple sclerosis. Methods: Female Lewis rats were immunized with 3 pVAXhsp65 doses by intramuscular route. Fifteen days after the last DNA dose the animals were evaluated for specific immunity or submitted to induction of EAE. Animals were evaluated daily for weight loss and clinical score, and euthanized during the recovery phase to assess the immune response and inflammatory infiltration at the central nervous system. Results: Immunization with pVAXhsp65 induced a specific immune response characterized by production of IgG(2b) anti-hsp65 antibodies and IFN-gamma secretion. Previous immunization with pVAXhsp65 did not change EAE clinical manifestations (weight and clinical score). However, the vaccine clearly decreased brain and lumbar spinal cord inflammation. In addition, it downmodulated IFN-gamma and IL-10 production by peripheral lymphoid organs. Conclusion: Our data demonstrated that this vaccine does not trigger a deleterious effect on EAE development and also points to a potential protective effect. Copyright (C) 2010 S. Karger AG, Basel
Resumo:
Study Design. In vitro biomechanical investigation of the screw-holding capacity. Objective. To evaluate the effect of repetitive screw-hole use on the insertional torque and retentive strength of vertebral system screws. Summary and Background Data. Placement and removal of vertebral system screws is sometimes necessary during the surgical procedures in order to assess the walls of the pilot hole. This procedure may compromise the holding capacity of the implant. Methods. Screws with outer diameter measuring 5, 6, and 7 mm were inserted into wood, polyurethane, polyethylene, and cancellous bone cylindrical blocks. The pilot holes were made with drills of a smaller, equal, or wider diameter than the inner screw diameter. Three experimental groups were established based on the number of insertions and reinsertions of the screws and subgroups were created according to the outer diameter of the screw and the diameter of the pilot hole used. Results. A reduction of screw-holding capacity was observed between the first and the following insertions regardless the anchorage material. The pattern of reduction of retentive strength was not similar to the pattern of torque reduction. The pullout strength was more pronounced between the first and the last insertions, while the torque decreased more proportionally from the first to the last insertions. Conclusion. Insertion and reinsertion of the screws of the vertebral fixation system used in the present study reduced the insertion torque and screw purchase.
Resumo:
The aim of this study was to establish normal ranges of blood flow velocities and indices in the fetal ductus venosus (DV) during the second half of normal pregnancy. A Doppler study of 60 healthy pregnant women without fetal pathologies was performed during the second half of pregnancy. The peak systolic velocity (PSV), peak diastolic velocity (PDV), maximum velocity during atrial contraction (VAC), peak systolic velocity/maximum velocity during atrial contraction (S/A ratio), pulsatility index for the vein (PIV), preload index (PLI) and velocity index for the vein (VIV) were calculated from the DV at 4-week intervals. A significant increase in PSV, PDV and VAC was observed from the 20-23(6/7) to the 28-31(6/7) weeks, with stabilization of values until the end of the pregnancy. On the other hand, the study showed a significant decrease for the S/A ratio, PIV, PLI and VIV from the 20-23(6/7) to the 28-31(6/7) weeks and remaining stable from then until term. (E-mail:dralemar@uol.com.br) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
Resumo:
Aim: To trace a reference curve for motor development from birth up to 12 months of corrected chronological age in infants born preterm and low birth weight. Methods: This is a cross-sectional study with a sample of 308 preterm infants (53% boys) weighing < 2500 g at birth. The Alberta Infant Motor Scale (AIMS) was used for motor development assessment. Results: Comparing the motor performance of preterm infants with infants from a standardized sample on the AIMS, it was found that, except for the age group of the newborn, preterm infants showed lower motor development scores in comparison with the AIMS normative sample in all age groups between 1 and 12 months. The curve of motor development showed a continuous increase in the number of motor skills of preterm infants during their first 12 months of age. However, the average of motor acquisitions of preterm infants showed a nonlinear pattern with a standard indicator of stabilization between 8 and 10 months of age. Conclusion: Preterm infants, 1-12 months of age, showed motor development AIMS scores lower than the standards established in the normative sample. The findings may contribute as norm-reference for assessing the motor development of preterm infants in follow-up programmes in developing countries.
Resumo:
Leather industries which promote hide stabilization by the conventional chrome-tanning process are a major source of pollution because of the resultant chromium-rich wastes. In this work, an extensive characterization of such a chromium-rich waste sludge is presented, regarding its chemical composition (XRF), crystalline phase contents (XRD), organic carbon content (TOC), thermal behavior by thermogravimetry (TG) and differential scanning calorimetry (DSC), as well as its stability under chemical attack (the concentration of important ions in the leachates being determined by capillary electrophoresis) and when submitted to temperatures as high as 1100 degrees C, in air. The material showed the tendency to produce some undesirable, and previously non-detected hexavalent chromium when exposed to high temperatures, but after washing off the soluble salts and the elimination of the organic matter by firing, the resultant material was succesfully tested as a ceramic pigment in a conventional glaze composition usually employed in the ceramic the industry. (C) 2009 Elsevier Ltd and Techna Group S.r.l. All rights reserved.
Resumo:
Background: Birth weight is positively associated with adult bone mass. However, it is not clear if its effect is already evident in early adulthood. Objective: To investigate the association between birth weight, adult body size, the interaction between them and bone mass in young adults. Methods: Bone densitometry by DXA was performed on 496 individuals (240 men) aged 23-24 years from the 1978/79 Ribeirao Preto (southern Brazil) birth cohort, who were born and still residing in the city in 2002. Birth weight and length as well as adult weight and height were directly measured and converted to z-scores. The influence of birth weight and length, and adult weight and height on bone area (BA), bone mineral content (BMC) and bone mineral density (BMD) at the lumbar spine, proximal femur and femoral neck were investigated through simple and multiple linear regression models. Adjustments were made for sex, skin color, gestational age, physical activity level, smoking status and dietary consumption of protein, calcium and alcohol. Interaction terms between birth weight and adult weight, and birth length and adult height were tested. Results: Men in the highest fertile of birth weight distribution had greater BA and BMC at all three bone sites when compared with their counterparts in the lowest tertiles (p<0.008). For BMD, this trend was observed only in the lumbar spine. Adult weight and height were positively associated with BA and BMC at all three bone sites (p<0.05). For BMD, these associations were seen for adult weight, but for adult height an association was observed only in the lumbar spine. Birth weight retained positive associations with proximal femur BA and BMC after adjustments for current weight and height. No interaction was observed between variables measuring prenatal growth and adult body size. Conclusion: Birth weight and postnatal growth are independent determinants of adult bone mass in a sample of Brazilian adults. This effect is already evident in early adulthood. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
The superior cervical ganglion (SCG) in mammals varies in structure according to developmental age, body size, gender, lateral asymmetry, the size and nuclear content of neurons and the complexity and synaptic coverage of their dendritic trees. In small and medium-sized mammals, neuron number and size increase from birth to adulthood and, in phylogenetic studies, vary with body size. However, recent studies on larger animals suggest that body weight does not, in general, accurately predict neuron number. We have applied design-based stereological tools at the light-microscopic level to assess the volumetric composition of ganglia and to estimate the numbers and sizes of neurons in SCGs from rats, capybaras and horses. Using transmission electron microscopy, we have obtained design-based estimates of the surface coverage of dendrites by postsynaptic apposition zones and model-based estimates of the numbers and sizes of synaptophysin-labelled axo-dendritic synaptic disks. Linear regression analysis of log-transformed data has been undertaken in order to establish the nature of the relationships between numbers and SCG volume (V(scg)). For SCGs (five per species), the allometric relationship for neuron number (N) is N=35,067xV (scg) (0.781) and that for synapses is N=20,095,000xV (scg) (1.328) , the former being a good predictor and the latter a poor predictor of synapse number. Our findings thus reveal the nature of SCG growth in terms of its main ingredients (neurons, neuropil, blood vessels) and show that larger mammals have SCG neurons exhibiting more complex arborizations and greater numbers of axo-dendritic synapses.
Resumo:
Fibrous dysplasia is a benign fibro-osseous disease that affects one or more bones. Although its etiology has been defined, the mechanism of spontaneous resolution is still unclear. There is strong evidence indicating the occurrence of stabilization when bone maturation is completed. Deformities that lead to esthetic and functional disorders are observed in almost all cases. Plastic surgery is often recommended when the maxilla and mandible are involved. In the case of mild deformities, careful follow-up during skeletal growth is recommended. We describe here the 23-year follow-up of a patient with monostotic fibrous dysplasia whose disease had stabilized by 13 years of follow-up. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107: 229-234)
Resumo:
The objective of the present study was to assess the influence of decortication of the posterior elements of the vertebra (recipient bed) and the nature of the bone graft (cortical or cancellous bone) on graft integration and bone, cartilage and fiber neoformation in the interface between the vertebral recipient bed and the bone graft. Seventy-two male Wistar rats were divided into four experimental groups according to the presence or absence of decortication of the posterior vertebral elements and the use of a cortical or cancellous bone graft. Group I-the posterior elements were decorticated and cancellous bone used. Group II-the posterior elements were decorticated and cortical graft was used. Group III-the posterior elements were not decorticated and cancellous graft was used. Group IV-the posterior elements were not decorticated and cortical graft was used. The animals were killed 3, 6 and 9 weeks after surgery and the interface between the posterior elements and the bone graft was subjected to histomorphometric evaluation. Mean percent neoformed bone was 40.8% in group I (decortication and cancellous graft), 39.13% in group II (decortication and cortical graft), 6.13% in group III (non-decorticated and cancellous graft), and 9.27% in group IV (non-decorticated and cortical graft) for animals killed at 3 weeks (P = 0.0005). For animals killed at 6 weeks, the mean percent was 38.53% for group I, 40.40% for group II, 10.27% for group III, and 7.6% for group IV (P = 0.0005), and for animals killed at 9 weeks, the mean was 25.93% for group I, 30.6% for group II, 16.4% for group III, and 18.73% for group IV (P = 0.0026). The mean percent neoformed cartilage tissue was 8.36% for group I, 7.46% for group II, 11.1% for group III, and 9.13% for group IV for the animals killed at 3 weeks (P = 0.6544); 6.6% for group I, 8.07% for group, 7.47% for group III and 6.13% for group IV (P = 0.4889) for animals killed at 6 weeks, and 3.13% for group I, 4.06% for group II, 10.53% for group III and 12.07% for group IV (P = 0.0006) for animals killed at 9 weeks. Mean percent neoformed fibrous tissue was 11% for group I, 6.13% for group II, 26.27% for group III and 21.87% for group IV for animals killed at 3 weeks (P = 0.0008); 7.67% for group I, 7.1% for group II, 9.8% for group III and 10.4% for group IV (P = 0.7880) for animals killed at 6 weeks, and 3.73% for group I, 4.4% for group II, 6.67% for group III and 6.8% for group IV (P = 0.0214) for animals killed at 9 weeks. The statistically significant differences in percent tissue formation were related to decortication of the posterior elements. The use of a cortical or cancellous graft did not influence tissue neoformation. Ossification in the interface of the recipient graft bed was of the intramembranous type in the decorticated animals and endochondral type in the non-decorticated animals.