92 resultados para SIMPLE-METAL NANOWIRES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method was optimized and validated for determination of ractopamine hydrochloride (RAC) in raw material and feed additives by HPLC for use in quality control in veterinary industries. The best-optimized conditions were a C8 column (250 x 4.6 mm id, 5.0 mu m particle size) at room temperature with acetonitrile-100 mM sodium acetate buffer (pH 5.0; 75 + 25, v/v) mobile phase at a flow rate of 1.0 mL/min and UV detection at 275 nm. With these conditions, the retention time of RAC was around 5.2 min, and standard curves were linear in the concentration range of 160-240 mu g/mL (correlation coefficient >= 0.999). Validation parameters, such as selectivity, linearity, limit of detection (ranged from 1.60 to 2.05 mu g/mL), limit of quantification (ranged from 4.26 to 6.84 mu g/mL), precision (relative standard deviation <= 1.87%), accuracy (ranged from 96.97 to 100.54%), and robustness, gave results within acceptable ranges. Therefore, the developed method can be successfully applied for the routine quality control analysis of raw material and feed additives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical microscopy and centrifugation were used to observe the Structural changes during evaporation of a commercial skin lotion of unknown composition. The degree of evaporation was determined from the changed weight of a microscope slide with the emulsion on a defined area and thickness, the evaporation loss versus time being measured by a balance under an infrared lamp. The results revealed not only which parts of the emulsion were most prone to evaporation without chemical analysis, but also gave surprising information as to which kind of structures would appear after extensive evaporation. The importance of these changes for the action of a skin lotion is briefly discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chicken eggs were inoculated with suspensions of ambient air particles (<= 10 mu m, PM(10)) from Sao Paulo city in 3, 0.3 or 0.03 mu g doses on one of the four early days of embryo development. On the eleventh day of development alterations were observed on embryos inoculated with PM(10) 3 mu g on the third day. Particles analysis showed high content of metals. Hence, embryos were also inoculated with PM(10) (3 mu g) combined with metal chelating EDTA. PM(10) (3 mu g) embryos presented underdevelopment (stage 29.44 +/- 11.4) compared to vehicle and positive controls (stage 36.44 +/- 0.51 Saline and stage 31.20 +/- 9.7 Cyclophosphamide, p <= 0.05); higher (47%) mortality rate (23% Saline and 42% Cyclophosphamide) and low (68%) viability (100% Saline and 70% Cyclophosphamide, p = 0.04). Effects were attenuated when embryos received PM(10) + EDTA (stage 33.63 +/- 0.94, 18.9% mortality rate and 82% viability). PM(10) from Sao Paulo city is embryotoxic and metal may be implicated in the toxic mechanism. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss the expectation propagation (EP) algorithm for approximate Bayesian inference using a factorizing posterior approximation. For neural network models, we use a central limit theorem argument to make EP tractable when the number of parameters is large. For two types of models, we show that EP can achieve optimal generalization performance when data are drawn from a simple distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Studies have shown that human immunodeficiency virus (HIV) residual risk is higher in Brazilian than in US and European blood donors, probably due to failure to defer at-risk individuals in Brazil. This study assessed the impact of an educational brochure in enhancing blood donors` knowledge about screening test window phase and reducing at-risk individuals from donating. STUDY DESIGN AND METHODS: This trial compared an educational intervention with a blood center`s usual practice. The brochure was distributed in alternating months to all donors. After donating, sampled participants completed two questions about their HIV window period knowledge. The impact on HIV risk deferral, leaving without donation, confidential unit exclusion (CUE) use, and test positivity was also analyzed. RESULTS: From August to November 2007 we evaluated 33,940 donations in the main collection center of Fundacao Pro-Sangue/Hemocentro de Sao Paulo in Sao Paulo, Brazil. A significant (p < 0.001) pamphlet effect was found on correct responses to both questions assessing HIV window phase knowledge (68.1% vs. 52.9%) and transfusion risk (91.1% vs. 87.2%). After adjusting for sex and age, the pamphlet effect was strongest for people with more than 8 years of education. There was no significant pamphlet effect on HIV risk deferral rate, leaving without donation, use of CUE, or infectious disease rates. CONCLUSION: While the educational pamphlet increased window period knowledge, contrary to expectations this information alone was not enough to make donors self-defer or acknowledge their behavioral risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: There remains significant concern about the long-term safety of drug-eluting stents (DES). However, bare metal stents (BMS) have been used safely for over two decades. There is therefore a pressing need to explore alternative strategies for reducing restenosis with BMS. This study was designed to examine whether IVUS-guided cutting balloon angioplasty (CBA) with BMS could convey similar restenosis rates to DES. Methods and results: In the randomised REstenosis reDUction by Cutting balloon angioplasty Evaluation (REDUCE III) study, 521 patients were divided into four groups based on device and IVUS use before BMS (IVUS-CBA-BMS: 137 patients; Angio-CBA-BMS: 123; IVUS-BA-BMS: 142; and Angio-BA-BMS: 119). At follow-up, the IVUS-CBA-BMS group had a significantly lower restenosis rate (6.6%) than the other groups (p=0.016). We performed a quantitative coronary angiography (QCA) based matched comparison between an IVUS-guided CBA-BMS strategy (REDUCE III) and a DES strategy (Rapamycin-Eluting-Stent Evaluation At Rotterdam Cardiology. Hospital, the RESEARCH study). We matched the presence of diabetes, vessel size, and lesion severity by QCA. Restenosis (>50% diameter stenosis at follow-up) and target vessel revascularisation (TVR) were examined. QCA-matched comparison resulted in 120-paired lesions. While acute gain was significantly greater in IVUS-CBA-BMS than DES (1.65 +/- 0.41 mm vs. 1.28 +/- 0.57 mm, p=0.001), late loss was significantly less with DES than with IVUS-CBA-BMS (0.03 +/- 0.42 mm vs. 0.80 +/- 0.47 mm, p=0.001). However, no difference was found in restenosis rates (IVUS-CBA-BMS: 6.6% vs. DES: 5.0%, p=0.582) and TVR (6.6% and 6.6%, respectively). Conclusions: An IVUS-guided CBA-BMS strategy yielded restenosis rates similar to those achieved by DES and provided an effective alternative to the use of DES.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A risk score model was developed based in a population of 1,224 individuals from the general population without known diabetes aging 35 years or more from an urban Brazilian population sample in order to select individuals who should be screened in subsequent testing and improve the efficacy of public health assurance. External validation was performed in a second, independent, population from a different city ascertained through a similar epidemiological protocol. The risk score was developed by multiple logistic regression and model performance and cutoff values were derived from a receiver operating characteristic curve. Model`s capacity of predicting fasting blood glucose levels was tested analyzing data from a 5-year follow-up protocol conducted in the general population. Items independently and significantly associated with diabetes were age, BMI and known hypertension. Sensitivity, specificity and proportion of further testing necessary for the best cutoff value were 75.9, 66.9 and 37.2%, respectively. External validation confirmed the model`s adequacy (AUC equal to 0.72). Finally, model score was also capable of predicting fasting blood glucose progression in non-diabetic individuals in a 5-year follow-up period. In conclusion, this simple diabetes risk score was able to identify individuals with an increased likelihood of having diabetes and it can be used to stratify subpopulations in which performing of subsequent tests is necessary and probably cost-effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Cannabis is the most used illicit drug in the world, and its use has been associated with prefrontal cortex (PFC) dysfunction, including deficits in executive functions (EF). Considering that EF may influence treatment outcome, it would be interesting to have a brief neuropsychological battery to assess EF in chronic cannabis users (CCU). In the present study, the Frontal Assessment Battery (FAB), a brief, easy to use neuropsychological instrument aimed to evaluate EF, was used to evaluate cognitive functioning of CCU. Methods: We evaluated 107 abstinent CCU with the FAB and compared with 44 controls matched for age, estimated IQ, and years of education. Results: CCU performed poorly as compared to controls (FAB total score = 16.53 vs. 17.09, p .05). CCU had also a poor performance in the Motor Programming subtest (2.47 vs. 2.73, p .05). Conclusion: This study examined effects of cannabis in executive functioning and showed evidence that the FAB is sensitive to detect EF deficits in early abstinent chronic cannabis users. Clinical significance of these findings remains to be investigated in further longitudinal studies. FAB may be useful as a screening instrument to evaluate the necessity for a complete neuropsychological assessment in this population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To describe the use of self-expandable metallic stents to manage malignant colorectal obstructions and to compare the radiation dose between fluoroscopic guidance of stent placement and combined endoscopic and fluoroscopic guidance. Materials and Methods: From January 1998 to December 2007, 467 oncology patients undergoing colorectal stent placement in a single center were included in the study. Informed consent was obtained in all cases. All procedures were performed with fluoroscopic or combined fluoroscopic and endoscopic guidance. Inclusion criteria were total or partial colorectal obstruction of neoplastic origin. Exclusion criteria were life expectancy shorter than I month, suspicion of perforation, and/or severe colonic neoplastic bleeding. Procedure time and radiation dose were recorded, and technical and clinical success were evaluated. Follow-up was performed by clinical examination and simple abdominal radiographs at 1 day and at I, 3, 6, and 12 months. Results: Of 467 procedures, technical success was achieved in 432 (92.5%). Thirty-five treatments (7.5%) were technical failures, and the patients were advised to undergo surgery. Significant differences in radiation dose and clinical success were found between the fluoroscopy and combined-technique groups (P < .001). Total decompression was achieved in 372 cases, 29 patients showed remarkable improvement, 11 showed slight improvement, and 20 showed clinical failure. Complications were recorded in 89 patients (19%), the most significant were perforation (2.3%) and stent migration (6.9%). Mean interventional time and radiation dose were 67 minutes and 3,378 dGy.cm(2), respectively. Conclusions: Treatment of colonic obstruction with stents requires a long time in the interventional room and considerable radiation dose. Nevertheless, the clinical benefits and improvement in quality of life justify the radiation risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experience with laparoscopic liver resections has increased in recent years, and so have the number of patients operated on by minimally invasive techniques. Specimen extraction is an important step of laparoscopic liver resection. The size of the specimen, is Usually a limitation for the use Of laparoscopy. The aim of this paper is to describe a new technique combining Pfannenstiel suprapubic incision and obstetric forceps to remove a large specimen from laparoscopic liver resections. The present technique allows an expeditious extraction of intact specimens, even huge ones, through a standard suprapubic Pfannenstiel incision. This technique has additional functional and cosmetic advantages over other techniques of specimen retrieval. We believe that the described technique is feasible, can be easily and rapidly performed, and facilitates laparoscopic liver resection by reducing the technical difficulties for specimen removal and may also be used in other abdominal laparoscopic interventions that deal with large surgical specimens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To demonstrate that the evaluation of erythrocyte dysmorphism by light microscopy with lowering of the condenser lens (LMLC) is useful to identify patients with a haematuria of glomerular or non-glomerular origin. Methods: A comparative double-blind study between phase contrast microscopy (PCM) and LMLC is reported to evaluate the efficacy of these techniques. Urine samples of 39 patients followed up for 9 months were analyzed, and classified as glomerular and non-glomerular haematuria. The different microscopic techniques were compared using receiver-operator curve (ROC) analysis and area under curve (AUC). Reproducibility was assessed by coefficient of variation (CV). Results: Specific cut-offs were set for each method according to their best rate of specificity and sensitivity as follows: 30% for phase contrast microscopy and 40% for standard LMLC, reaching in the first method the rate of 95% and 100% of sensitivity and specificity, respectively, and in the second method the rate of 90% and 100% of sensitivity and specificity, respectively. In ROC analysis, AUC for PCM was 0.99 and AUC for LMLC was 0.96. The CV was very similar in glomerular haematuria group for PCM (35%) and LMLC (35.3%). Conclusion: LMLC proved to be effective in contributing to the direction of investigation of haematuria, toward the nephrological or urological side. This method can substitute PCM when this equipment is not available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Described in this article is a novel device that facilitates study of the cross-sectional anatomy of the human head. In designing our device, we aimed to protect sections of the head from the destructive action of handling during anatomy laboratory while also ensuring excellent visualization of the anatomic structures. We used an electric saw to create 15-mm sections of three cadaver heads in the three traditional anatomic planes and inserted each section into a thin, perforated display box made of transparent acrylic material. The thin display boxes with head sections are kept in anatomical order in a larger transparent acrylic storage box containing formaldehyde solution, which preserves the specimens but also permits direct observation of the structures and their anatomic relationships to each other. This box-within-box design allows students to easily view sections of a head in its anatomical position as well as to examine internal structures by manipulating individual display boxes without altering the integrity of the preparations. This methodology for demonstrating cross-section anatomy allows efficient use of cadaveric material and technician time while also giving learners the best possible handling and visualization of complex anatomic structures. Our approach to teaching cross-sectional anatomy of the head can be applied to any part of human body, and the value of our device design will only increase as more complicated understandings of cross-sectional anatomy are required by advances and proliferation of imaging technology. Anat Sci Educ 3: 141-143, 2010. (C) 2010 American Association of Anatomists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. There are no established clinical procedures for bonding zirconia to tooth structure using resin cements. Purpose. The purpose of this study was to evaluate the influence of metal primers, resin cements, and aging on bonding to zirconia. Material and methods. Zirconia was treated with commercial primers developed for bonding to metal alloys (Metaltite, Metal Primer II, Alloy Primer or Totalbond). Non-primed specimens were considered as controls. One-hundred disk-shaped specimens (19 x 4 mm) were cemented to composite resin substrates using Panavia or RelyX Unicem (n=5). Microtensile bond strength specimens were tested after 48 hours and 5 months (150 days), and failure modes were classified as type 1 (between ceramic/cement), 2 (between composite resin/cement) or 3 (mixed). Data were analyzed by 3-way ANOVA and Multiple Comparison Tukey test (alpha=.05). Results. The interactions primer/luting system (P=.016) and luting system/storage time (P=.004) were statistically significant. The use of Alloy Primer significantly improved the bond strength of RelyX Unicem (P<.001), while for Panavia, none of the primers increased the bond strength compared to the control group. At 48 hours, Panavia had statistically higher bond strength (P=.004) than Unicem (13.9 +/- 4.4MPa and 10.2 +/- 6.6MPa, respectively). However, both luting systems presented decreasing, statistically similar; values after aging (Panavia: 3.6 +/- 2.2MPa; Unicem: 6.1 +/- 5.3MPa). At 48 hours, Alloy Primer/Unicem had the lowest incidence of type 1 failure (8%). After aging, all the groups showed a predominance of type 1 failures. Conclusions. The use of Alloy Primer improved bond strength between RelyX Unicem and zirconia. Though the initial values obtained with Panavia were significantly higher than RelyX Unicem, after aging, both luting agents presented statistically similar performances. (J Prosthet Dent 2011;105:296-303)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of framework design on the fracture resistance of metal-ceramic implant-supported crowns. Screw-retained molar crowns with a screw access hole composed of metal or porcelain were compared to a cement-retained crown (control). For each group (n = 10), five crowns were subjected to dynamic loading (1,200,000 x 100 N x 2 Hz at 37 degrees C). Afterward, all specimens were loaded to failure using a universal testing machine. Significant differences could be established between the cement-and screw-retained groups (P <= .05), but no difference was found between the screw-retained groups and the specimens subjected to dynamic loading. Occlusal discontinuity of screw-retained crowns affects their resistance, and the metallic support on the screw access hole did not reinforce the crowns. Int J Prosthodont 2010;23:350-352.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spinal cord injury (SCI) causes motor and sensory deficits that impair functional performance, and significantly impacts life expectancy and quality. Animal models provide a good opportunity to test therapeutic strategies in vivo. C57BL/6 mice were subjected to laminectomy at T9 and compression with a vascular clip (30 g force, 1 min). Two groups were analyzed: injured group (SCI, n = 33) and laminectomy only (Sham, n = 15). Locomotor behavior (Basso mouse scale-BMS and global mobility) was assessed weekly. Morphological analyses were performed by LM and EM. The Sham group did not show any morphofunctional alteration. All SCI animals showed flaccid paralysis 24 h after injury. with subsequent improvement. The BMS score of the SCI group improved until the intermediate phase (2.037 +/- 1.198): the Sham animals maintained the highest BMS score (8.981 +/- 0.056). p < 0.001 during the entire time. The locomotor speed was slower in the SCI animals (5.581 +/- 0.871) than in the Sham animals (15.80 +/- 1.166), p < 0.001. Morphological analysis of the SCI group showed, in the acute phase, edema, hemorrhage, multiple cavities, fiber degeneration, cell death and demyelination. In the chronic phase we observed glial scarring, neuron death, and remyelination of spared axons by oligodendrocytes and Schwann cells. In conclusion, we established a simple, reliable, and inexpensive clip compression model in mice, with functional and morphological reproducibility and good validity. The availability of producing reliable injuries with appropriate outcome measures represents great potential for studies involving cellular mechanisms of primary injury and repair after traumatic SCI. (C) 2008 Elsevier B.V. All rights reserved.