84 resultados para Mini-horse
Characterization of Equine Adipose Tissue-Derived Progenitor Cells Before and After Cryopreservation
Resumo:
In horses, stem cell therapies are a promising tool to the treatment of many injuries, which are common consequences of athletic endeavor, resulting in high morbidity and often compromising the performance. In spite of many advantages, the isolation of stem cells similar to human, from equine adipose tissue, occurred only recently. The aim of this study was to isolate equine adipose tissue-derived progenitor cells (eAT-PC), to characterize their proliferative potential, and to study their differentiation capacity before and after cryopreservation. The cells, isolated from horse adipose tissue, presented similar fibroblast-like cell morphology in vitro. Their proliferation rate was evaluated during 63 days (23 passages) before and after cryopreservation. After the induction of osteogenic differentiation, von Kossa staining and positive immunostaining studies revealed the formation of calcified extracellular matrix confirming the osteogenic potential of these cells. Adipogenic differentiation was induced using two protocols: routine and other one developed by us, while our protocol requires a shorter time (Oil Red O staining revealed significant accumulation of lipid droplets after 7 days). Chondrogenic differentiation was observed after 21 days of induced pellet culture, as evidenced by histological (toluidine blue) and immunohistochemistry studies. Our data demonstrate that eAT-PC can be easily isolated and successfully expanded in vitro while presenting significant proliferating rate. These cells can be maintained undifferentiated in vitro and can efficiently undergo differentiation at least into mesodermal derivates. These eAT-PC properties were preserved even after cryopreservation. Our findings classify eAT-PC as a promising type of progenitor cells that can be applied in different cell therapies in equines.
Resumo:
Serum samples were collected from 582 horses from 40 stud farms in the State of Sao Paulo and tick (Acari: Ixodidae) infestations were evaluated on them. Serum samples were subjected to the complement fixation test (CFT) and a competitive inhibition ELISA (cELISA) for Babesia caballi and Theileria equi. Logistic regression analyses were performed to construct multivariate models that could explain the dependent variable (horses positive for B. caballi or T equi) as a function of the independent variables (presence or abundance of each one of the rick species found on the farms). A higher overall prevalence of B. caballi (54.1%) than of T equi (21.6%) was found by the two tests. The ticks Dermacentor nitens Neumann, 1897, Amblyomma cajennense (Fabricius, 1787) and Rbipicephalus (Boopbilus) microplus (Canestrini, 1887) were present on horses on 38 (95%), 20 (50%), and 4 (10%) farms, respectively. Infestations by D. nitens were statistically associated with B. caballi-positive horses on the farms by either the CFT or cELISA. Infestations by A. cajennense were statistically associated with T equi-positive horses on the farms by either CFT or cELISA.
Resumo:
Amblyomma incisum Neumann is a major tick species in the Atlantic Forest of Brazil. Tapir is the main host for adult ticks and a high aggressiveness of nymphs to humans has been reported. In this work data on the biology and life cycle of this tick species is presented for the first time. It was shown that horse is a suitable host for A. incisum adults and rabbit for larvae and nymphs. It was also shown that A. incisum is a big tick species (mean engorged female weight of 1.96 g) with a long life cycle which lasts 262.3 days when maintained at 27A degrees C and 85% RH. These laboratory conditions were, however, inappropriate and egg hatching rate (1.2%) was very low. Nevertheless egg hatching of ticks in a forest patch increased considerably (72.2%) indicating that this A. incisum population is highly dependent on a forest-like environment.
Resumo:
The purpose of this in vitro study was to compare the bond strength between fiber post and laser-treated root canals. Forty single-rooted bovine teeth were endodontically treated and randomly divided into four groups of equal size according to the root canal treatment: group 1 conventional treatment (without laser irradiation); group 2 Nd:YAG laser (1.5 W, 10 Hz, 100 mJ); group 3 Er,Cr:YSGG laser (0.75 W, 20 Hz); and group 4 Nd:YAG + Er,Cr:YSGG lasers. The fiber posts were cemented with an adhesive system + resin cement, in accordance with the manufacturer`s instructions. A mini acrylic pipe was fixed on the coronal section of the post using a light-polymerized resin. Specimens were mounted on an acrylic pipe with a self-polymerized resin. Retention forces were determined using a universal testing machine (0.5 mm/min). Data were analyzed using one-way ANOVA and Tukey tests (p < 0.05). The post retention force in group 2 was found to be lower than that in the other experimental groups. Fractures were observed at the interface between the dentin and the resin in all groups. High-intensity lasers can be used in conventional endodontic treatment; however, root canal surface irradiation using the Nd:YAG laser was shown to negatively affect the post retention force.
Resumo:
Purpose: Orthodontic miniscrews are commonly used to achieve absolute anchorage during tooth movement. One of the most frequent complications is screw loss as a result of root contact. Increased precision during the process of miniscrew insertion would help prevent screw loss and potential root damage, improving treatment outcomes. Stereo lithographic surgical guides have been commonly used for prosthetic implants to increase the precision of insertion. The objective of this paper was to describe the use of a stereolithographic surgical guide suitable for one-component orthodontic miniscrews based on cone beam computed tomography (CBCT) data and to evaluate implant placement accuracy. Materials and Methods: Acrylic splints were adapted to the dental arches of four patients, and six radiopaque reference points were filled with gutta-percha. The patients were submitted to CBCT while they wore the occlusal splint. Another series of images was captured with the splint alone. After superimposition and segmentation, miniscrew insertion was simulated using planning software that allowed the user to check the implant position in all planes and in three dimensions. In a rapid-prototyping machine, a stereolithographic guide was fabricated with metallic sleeves located at the insertion points to allow for three-dimensional control of the pilot bur. The surgical guide was worn during surgery. After implant insertion, each patient was submitted to CBCT a second time to verify the implant position and the accuracy of the placement of the miniscrews. Results: The average differences between the planned and inserted positions for the ten miniscrews were 0.86 mm at the coronal end, 0.71 mm at the center, and 0.87 mm at the apical tip. The average angular discrepancy was 1.76 degrees. Conclusions: The use of stereolithographic surgical guides based on CBCT data allows for accurate orthodontic mini screw insertion without damaging neighboring anatomic structures. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:860-865
Resumo:
Introduction: The aim of this study was to compare the influence of preflaring on the accuracy of 4 electronic apex locators (EALs): Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex Locator, and Apex DSP. Methods: Forty extracted teeth were preflared by using S1 and SX ProTaper instruments. The working length was established by reducing 1 mm from the total length (TL). The ability of the EALs to detect precise (-1 mm from TL) and acceptable (-1+/-0.5 mm from TL) measurements in unflared and preflared canals was determined. Results: The precise and acceptable (P/A) readings in unflared canals for Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex and Apex DSP were 50%/97.5%, 47.5%/95%, 50%/97.5%, and 45%/67.5%, respectively. For preflared canals, the readings were 75%/97.5%, 55%/95%, 75%/97.5%, and 60%/87.5%, respectively. For precise criteria, the preflared procedure increased the percentage of accurate electronic readings for the Root ZX and the Mini Apex Locator (P < .05). For acceptable criteria, no differences were found among Root ZX, Elements Diagnostic Unit and Apex Locator, and Mini Apex Locator (P > .05). Fisher test indicated the lower accuracy for Apex DSP (P < .05). Conclusions: The Root ZX and the Mini Apex Locator devices increased significantly the precision to determine the real working length after the preflaring procedure. All the EALs showed an acceptable determination of the working length between the ranges of+/-0.5mm except for the Apex DSP device, which had the lowest accuracy. (J Endod 2009;35:1300-1302)
Resumo:
Introduction: Mini-implants are placed in restricted sites, requiring an accurate surgical technique. However, no systematic study has quantified technique accuracy to reliably predict the surgical risks. Therefore, a graduated 3-dimensional radiographic-surgical guide (G-RSG) was proposed, and its inaccuracy and risk index (RI) were estimated. Methods: The sample consisted of 6 subjects (4 male, 2 female), who used mini-implant anchorage. Ten drill-free screws (DFS) were placed by using the G-RSG. The central point of the mesiodistal septum width (SW) was the selected implant site on the presurgical radiograph. The distances between DFS and the adjacent teeth (5-DFS and 6-DFS) were measured to evaluate screw centralization and inaccuracy degree (ID). These distances were statistically compared by independent t tests, and inaccuracy was determined by the expression ID = (5-DFS-6-DFS)/2, which represents deviation of the mini-implant`s final position regarding the central point initially selected. Then SW, ID, and screw diameter (SO) were combined to estimate the surgical risk with RI expressed by RI = SO/SW-ID. Results: The 5-DFS and 6-DFS distances were not significantly different. The ID of the G-RSG was 0.17 mm. The low ID ensured a safe RI (<1) in spite of the restricted SW. Conclusions: The G-RSG accuracy allowed fine prediction of the final DFS position in the inter-radicular septum, with a low RI, which is a helpful tool to estimate surgical risks. (Am J Orthod Dentofacial Orthop 2009; 136: 722-35)
Resumo:
Background: The diagnosis of acute pulmonary thromboembolism (APT) and its severity is challenging. No previous study has examined whether there is a linear relation between plasma DNA concentrations and the severity of APT. We examined this hypothesis in anesthetized dogs. We also examined the changes in plasma DNA concentrations in microspheres lung embolization and whether the therapy of APT with nitrite could modify APT-induced changes in plasma DNA concentrations. In vitro DNA release from blood clots was also studied. Methods: APT was induced with autologous blood clots (saline, 1, 3, or 5 ml/kg) injected into the right atrium. A group of dogs received 300 pm microspheres into the inferior vena cava to produce similar pulmonary hypertension. Another group of dogs received 6.75 mu mol/kg nitrite after APT with blood clots of 5 ml/kg. Hemodynamic evaluations were carried out for 120 min. DNA was extracted from plasma samples using QIAamp DNA Blood Mini Kit and quantified using Quant-iT (TM) PicoGreen (R) dsDNA detection kit at baseline and 120 min after APT. Results: APT produced dose-dependent increases in plasma DNA concentrations. which correlated positively with pulmonary vascular resistance (P=0.002, r=0.897) and with mean pulmonary arterial pressure (P=0.006, r=0.856). Conversely, lung embolization with microspheres produced no significant changes in plasma DNA concentrations. While nitrite attenuated APT-induced pulmonary hypertension, it produced no changes in plasma DNA concentrations. Blood clots released dose-dependent amounts of DNA in vitro. Conclusions: Cell-free DNA concentrations increase in proportion to the severity of APT, probably as a result of increasing amounts of thrombi obstructing the pulmonary vessels. (C) 2009 Elsevier B.V. All rights reserved.