111 resultados para FIXED-PARTIAL DENTURES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research evaluated the effects of Branemark protocol on electromyography of the masseter and temporal muscles. The patients were divided into two groups: Group 1: patients who wore an implant-supported prosthesis in the mandibular arch following Branemark protocol, and maxillary removable complete dentures; Group II: dentate individuals (control). Electromyography was carried out at rest, right (RL) and left (LL) laterality, protrusion and maximum voluntary contraction (MVC). Data were compared by t-test. At rest, a higher electromyographic (EMG) activity was observed in Group I, and the values were significant in the right masseter and left temporal muscles. In RL, there were statistically significant differences for right masseter (P < 0.01), left masseter and temporal muscles and for the left temporal muscle in LL (P < 0.05). In protrusion, Group I presented a higher EMG activity, and there was a statistically significant difference for the right masseter muscle (RM) (P < 0.05). In MVC, the EMG values were higher in Group II (control), but significant just for the right temporal muscle (P < 0.05). In conclusion, individuals with mandibular fixed dentures supported according to the Branemark protocol and maxillary removable complete dentures showed a higher activity of masticatory muscles during the mandibular postural clinical conditions examined; however, in the MVC, Group I presented lower values when compared to dentate group. Despite presenting different EMG values in all of the clinical conditions, both groups showed similar EMG patterns of muscle activation which demonstrates that the proposed treatment can be considered as a good option for oral rehabilitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Swallowed prostheses have been described in the literature, and in some cases, the diagnosis can be challenging, especially if the partial or complete denture is metal-free. This article presents a case of a swallowed partial denture and points to the importance of early diagnosis. A man was admitted to the emergency room complaining of progressive breathing difficulty while presenting with an extra volume in his neck. After inconclusive image examinations, endoscopy under sedation was used to identify and retrieve the foreign object, which was a metal-free acrylic partial denture. Early diagnosis and the correct treatment can avoid serious sequelae, such as edematous reactions, mucosal infection, and necrosis. Patients should be scheduled for regular recall visits for evaluation of prosthesis fit and retention, condition of the abutments, and nocturnal wear. Int J Prosthodont 2010;23:339-341.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: In this retrospective study, we compared the cephalometric effects, the dental-arch changes, and the efficiency of Class II treatment with the pendulum appliance, cervical headgear, or extraction of 2 maxillary premolars, all associated with fixed appliance therapy. Methods: The sample of 82 patients with Class II malocclusion was divided into 3 groups: group 1 patients (n = 22; treatment time, 3.8 years) were treated with the pendulum appliance and fixed orthodontic appliances. Group 2 patients (n = 30; treatment time, 3.2 years) were treated with cervical headgear followed by fixed appliances; group 3 patients (n = 30; treatment time, 2.1 years) were treated with 2 maxillary premolar extractions and fixed appliances. The average starting ages of the groups ranged from 13.2 to 13.8 years. Data were obtained from serial cephalometric measurements and dental casts. The dental casts were analyzed with the treatment priority index. The treatment efficiency index was also used. Results: The 3 treatment protocols produced similar cephalometric effects, especially skeletally. Comparisons among the 2 distalizing appliances (pendulum and cervical headgear) and extraction of 2 maxillary premolars for Class II treatment showed changes primarily in the maxillary dentoalveolar component and dental relationships. The facial profile was similar after treatment, except for slightly more retrusion of the upper lip in the extraction patients. The treatment priority index demonstrated that occlusal outcomes also were similar among the groups. The treatment efficiency index had higher values for the extraction group. Conclusions: The effects of treatment with the pendulum appliance or cervical headgear and extraction of 2 maxillary premolars associated with fixed appliances were similar from both occlusal and cephalometric standpoints. Class II treatment with extraction of maxillary teeth was more efficient because of the shorter treatment time. Differences in maxillary incisor retraction should be noted, but these differences might have been due to greater maxillary dentoalveolar protrusion in the extraction group before treatment. (Am J Orthod Dentofacial Orthop 2009;136:833-42)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the effects produced by two different molar distalizers, namely cervical headgear (CHG) and the intraoral pendulum appliance, associated with fixed orthodontic appliances. The headgear group comprised 30 patients (19 females, 11 males), with an initial age of 13.07 years [standard deviation (SD) = 1.3], treated with CHG and fixed orthodontic appliances for a mean period of 3.28 years, and the pendulum group 22 patients (15 females, 7 males), with initial age of 13.75 years (SD = 1.86), treated with the pendulum appliance followed by fixed orthodontic appliances for a mean period of 4.12 years. Lateral cephalograms were taken at the start (T1) and on completion (T2) of orthodontic treatment. The pendulum and CHG groups were similar as to initial age, severity of the Class II malocclusion, gender distribution, initial cephalometric characteristics, and initial and final treatment priority index (TPI). Only treatment time was not similar between the groups, with a need for annualization for data for the pendulum group. The data were compared with independent t-tests. There was significantly greater restriction of maxillary forward growth and improvement of the skeletal maxillomandibular relationship in the CHG group (P < 0.05). The maxillary molars were more mesially tipped and extruded and the mandibular molars more uprighted in the CHG group compared with the pendulum group (P < 0.05). There was more labial tipping of the mandibular incisors and greater overbite reduction in the pendulum group. The pendulum appliance produced only dentoalveolar effects, different from the CHG appliance, which restricted maxillary forward displacement, thus improving the skeletal maxillomandibular relationship.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The extraction of teeth involves the elimination of extremely sensitive periodontal mechanoreceptors, which play an important role in oral sensory perception. Objectives: The aim of this study was to evaluate the recovery of interocclusal sensory perception for micro-thickness in individuals with different types of implant-supported prostheses. Materials and Methods: Wearers of complete dentures (CDs) comprised the negative control group (group A, n=17). The experimental group consisted of wearers of prostheses supported by osseointegrated implants (Group B, n=29), which was subsequently divided into 4 subgroups: B(1) (n=5) - implant supported overdentures (ISO) occluding with CD; B(2) (n=6) - implant-supported fixed prostheses (ISFP) occluding with CD; B3 (n=8) - wearers of maxillary and mandibular ISFP, and B(4) (n=10) - ISFP occluding with natural dentition (ND). Individuals with ND represented the positive control group (Group C, n=24). Aluminum foils measuring 10 mu m, 24 mu m, 30 mu m, 50 mu m, 80 mu m, and 104 mu m thickness were placed within the premolar area, adding up to 120 tests for each individual. Results: The mean tactile thresholds of groups A, B(1), B(2), B(3), B(4), and C were 92 mu m, 27 mu m, 27 mu m, 14 mu m, 10 mu m, and 10 mu m, respectively. [Correction added after publication online 18 April 2008: in the preceding sentence 92 mu m, 27 mu m, 14 mu m, 10 mu m and 10 mu m, was corrected to 92 mu m, 27 mu m, 27 mu m, 14 mu m, 10 mu m and 10 mu m.] The Kruskal-Wallis test revealed significant difference among groups (P < 0.05). The Dunn test revealed that group A was statistically different from groups C, B(3), and B(4), and that B(1) and B(2) were statistically different from group C. Conclusion: Progressive recovery of osseoperception as a function of the combination of implant-supported prostheses could be observed. Moreover, ISO and/or ISFP combinations may similarly maximize the recovery of osseoperception.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The objective of this study was to evaluate the stress on the cortical bone around single body dental implants supporting mandibular complete fixed denture with rigid (Neopronto System-Neodent) or semirigid splinting system (Barra Distal System-Neodent). Methods and Materials: Stress levels on several system components were analyzed through finite element analysis. Focusing on stress concentration at cortical bone around single body dental implants supporting mandibular complete fixed dentures with rigid ( Neopronto System-Neodent) or semirigid splinting system ( Barra Distal System-Neodent), after axial and oblique occlusal loading simulation, applied in the last cantilever element. Results: The results showed that semirigid implant splinting generated lower von Mises stress in the cortical bone under axial loading. Rigid implant splinting generated higher von Mises stress in the cortical bone under oblique loading. Conclusion: It was concluded that the use of a semirigid system for rehabilitation of edentulous mandibles by means of immediate implant-supported fixed complete denture is recommended, because it reduces stress concentration in the cortical bone. As a consequence, bone level is better preserved, and implant survival is improved. Nevertheless, for both situations the cortical bone integrity was protected, because the maximum stress level findings were lower than those pointed in the literature as being harmful. The maximum stress limit for cortical bone (167 MPa) represents the threshold between plastic and elastic state for a given material. Because any force is applied to an object, and there is no deformation, we can conclude that the elastic threshold was not surpassed, keeping its structural integrity. If the force is higher than the plastic threshold, the object will suffer permanent deformation. In cortical bone, this represents the beginning of bone resorption and/or remodeling processes, which, according to our simulated loading, would not occur. ( Implant Dent 2010; 19:39-49)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aimed to evaluate the cephalometric changes in Class II patients treated exclusively with cervical headgear (CHG) in the maxillary arch and fixed appliances in the mandibular arch as compared with a control group. The sample comprised 82 lateral cephalograms obtained pre- (T1) and post- (T2) treatment/observation of 41 subjects, divided into two groups: group 1-25 Class II division 1 patients (20 females and five males), with a mean pre-treatment age of 10.4 years, treated for a mean period of 2.5 years and group 2-16 Class II untreated subjects (12 females and four males), with a mean initial age of 9.9 years, followed for a mean period of 2.2 years. Treatment changes between the groups were compared by means of t-tests. The results showed restriction of maxillary forward displacement and also a restriction in maxillary length growth, improvement in the maxillomandibular relationship, restriction of mandibular incisor vertical development, reduction in overjet and overbite, and improvement in molar relationship. It was concluded that this treatment protocol corrected the Class II malocclusion characteristics primarily through maxillary forward growth restriction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study analyzed the surface roughness and weight loss in Plex Glass specimens caused by dentifrices, one conventional (Sorriso) and three specific for dentures. Materials and Methods: Specimens (n = 6) of Plex Glass were divided into 5 groups including: negative control (water); positive control 1 (Sorriso) and 2 (Corega Brite); Experimental 1 (containing Chloramine T, antimicrobial agent); and Experimental 2 (containing Zonyl, detergent). Brushing was performed in a toothbrushing machine (Pepsodent) with a soft brush and a suspension of toothpaste and distilled water for 300 minutes, representing 6 years of brushing. Weight was measured initially and after the trial period; roughness was measured after the trial period only. The results of roughness and weight loss were analyzed using ANOVA and Tukey tests at 5%. Results: The negative control (2.82 +/- 4.41 mg) showed the lowest weight loss. Experimental 1 (13.62 +/- 4.29 mg) and Experimental 2 (15.4 +/- 5.80 mg) were equal statistically, and Sorriso (23.22 +/- 7.23 mg) and Corega (28.83 +/- 6.34 mg) produced the greatest weight loss. Concerning roughness, the negative control group (0.03 +/- 0.01 mu m) showed the lowest value. No significant differences were found between Corega (13.43 +/- 1.65 mu m), Experimental 1 (12.28 +/- 0.85 mu m), and Experimental 2 (10.68 +/- 2.56 mu m). The Sorriso toothpaste produced the greatest amount of surface roughness (19.15 +/- 2.36 mu m). Conclusion: Of the tested dentifrices, the experimental preparations proved to be the least abrasive and resulted in the lowest weight loss after brushing of the acrylic. Based on these findings, the use of these experimental dentifrices is advocated. Further evaluation based on the ability of these preparations to remove biofilms is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An inappropriate prosthetic fit could cause stress over the interface implant/bone. The objective of this study was to compare stresses transmitted to implants from frameworks cast using different materials and to investigate a possible correlation between vertical misfits and these stresses. Fifteen one-piece cast frameworks simulating bars for fixed prosthesis in a model with five implants were fabricated and arranged into three different groups according to the material used for casting: CP Ti (commercially pure titanium), Co-Cr (cobalt-chromium) or Ni-Cr-Ti (nickel-chromium-titanium) alloys. Each framework was installed over the metal model with all screws tightened to a 10 N cm torque and then, vertical misfits were measured using an optical microscope. The stresses transmitted to implants were measured using quantitative photoelastic analysis in values of maximum shear stress (T), when each framework was tightened to the photoelastic model to a 10 N cm standardized torque. Stress data were statistically analyzed using one-way ANOVA and Tukey`s test and correlation tests were performed using Pearson`s rank correlation (alpha = 0.05). Mean and standard deviation values of vertical misfit are presented for CP Ti (22.40 +/- 9.05 mu m), Co-Cr (66.41 +/- 35.47 mu m) and Ni-Cr-Ti (32.20 +/- 24.47 mu m). Stresses generated by Co-Cr alloy (tau = 7.70 +/- 2.16 kPa) were significantly higher than those generated by CP Ti (tau = 5.86 +/- 1.55 kPa, p = 0.018) and Ni-Cr-Ti alloy (tau =5.74 +/- 3.05 kPa, p = 0.011), which were similar (p = 0.982). Correlations between vertical misfits and stresses around the implants were not significant as for any evaluated materials. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Orthodontic tooth movement uses mechanical forces that result in inflammation in the first days. Myeloperoxidase (MPO) is an enzyme found in polymorphonuclear neutrophil (PMN) granules, and it is used to estimate the number of PMN granules in tissues. So far, MPO has not been used to study the inflammatory alterations after the application of orthodontic tooth movement forces. The aim of this study was to determine MPO activity in the gingival crevicular fluid (GCF) and saliva (whole stimulated saliva) of orthodontic patients at different time points after fixed appliance activation. Methods: MPO was determined in the GCF and collected by means of periopaper from the saliva of 14 patients with orthodontic fixed appliances. GCF and saliva samples were collected at baseline, 2 hours, and 7 and 14 days after application of the orthodontic force. Results: Mean MPO activity was increased in both the GCF and saliva of orthodontic patients at 2 hours after appliance activation (P<0.02 for all comparisons). At 2 hours, PMN infiltration into the periodontal ligament from the orthodontic force probably results in the increased MPO level observed at this time point. Conclusions: MPO might be a good marker to assess inflammation in orthodontic movement; it deserves further studies in orthodontic therapy. (Am J Orthod Dentofacial Orthop 2010;138:613-6)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The objective of this study was to evaluate the accuracy and reproducibility of three complete denture biofilm indices (Prosthesis Hygiene Index; Jeganathan et al. Index; Budtz-J circle divide rgensen Index) by means of a computerised comparison method. Background: Clinical studies into denture hygiene have employed a large number of biofilm indices among their outcome variables. However, the knowledge about the validity of these indices is still scarce. Materials and methods: Sixty-two complete denture wearers were selected. The internal surfaces of the upper complete dentures were stained (5% erythrosine) and photographed. The slides were projected on paper, and the biofilm indices were applied over the photos by means of a scoring method. For the computerised method, the areas (total and biofilm-covered) were measured by dedicated software (Image Tool). In addition, to compare the results of the computerised method and Prosthetic Hygiene Index, a new scoring scale (including four and five graded) was introduced. For the Jeganathan et al. and Budtz-J circle divide rgensen indices, the original scales were used. Values for each index were compared with the computerised method by the Friedman test. Their reproducibility was measured by means of weighed kappa. Significance for both tests was set at 0.05. Results: The indices tested provided similar mean measures but they tended to overestimate biofilm coverage when compared with the computerised method (p < 0.001). Agreement between the Prosthesis Hygiene Index and the computerised method was not significant, regardless of the scale used. Jeghanathan et al. Index showed weak agreement, and consistent results were found for Budtz-Jorgensen Index (kappa = 0.19 and 0.39 respectively). Conclusion: Assessment of accuracy for the biofilm indices showed instrument bias that was similar among the tested methods. Weak inter-instrument reproducibility was found for the indices, except for the Budtz-J circle divide rgensen Index. This should be the method of choice for clinical studies when more sophisticated approaches are not possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the effect of three denture hygiene methods against different microbial biofilms formed on acrylic resin specimens. Materials and methods: The set (sterile stainless steel basket and specimens) was contaminated (37 degrees C for 48 hours) by a microbial inoculum with 106 colony-forming units (CFU)/ml (standard strains: Staphylococcus aureus, Streptococcus mutans, Escherichia coli, Candida albicans, Pseudomonas aeruginosa, and Enterococcus faecalis; field strains: S. mutans, C. albicans, C. glabrata, and C. tropicalis). After inoculation, specimens were cleansed by the following methods: (1) chemical: immersion in an alkaline peroxide solution (Bonyplus tablets) for 5 minutes; (2) mechanical: brushing with a dentifrice for removable prostheses (Dentu Creme) for 20 seconds; and (3) a combination of chemical and mechanical methods. Specimens were applied onto a Petri plate with appropriate culture medium for 10 minutes. Afterward, the specimens were removed and the plates incubated at 37 degrees C for 48 hours. Results: Chemical, mechanical, and combination methods showed no significant difference in the reduction of CFU for S. aureus, S. mutans (ATCC and field strain), and P. aeruginosa. Mechanical and combination methods were similar and more effective than the chemical method for E. faecalis, C. albicans (ATCC and field strain), and C. glabrata. The combination method was better than the chemical method for E. coli and C. tropicalis, and the mechanical method showed intermediate results. Conclusion: The three denture hygiene methods showed different effects depending on the type of microbial biofilms formed on acrylic base resin specimens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To examine whether denture use and recurrent sores caused by ill-fitting dentures are associated with intra-oral squamous cell carcinoma (IO-SCC) in individuals exposed to tobacco. Methods: We conducted a hospital-based case-control study. The study population comprised 124 patients with IO-SCC and the same number of controls (individually paired according to gender and age) recruited from outpatient units of the same hospital. Conditional logistic regression analysis assessed the effect of denture use and recurrent oral sores by ill-fitting dentures, adjusted by covariates on the lifetime exposure to alcohol and tobacco, socioeconomic standings, and dietary patterns. Results: The use of dentures showed no association with IO-SCC [adjusted odds ratio (OR) 1.40, 95 percent confidence interval 0.51-3.87, P = 0.513] in an assessment controlled by socioeconomic position, lifetime exposure to alcohol and tobacco, and dietary patterns. However, the report of recurrent sores caused by ill-fitting dentures showed significant association with the disease (adjusted OR 4.58, 95 percent confidence interval 1.52-13.76, P = 0.007). Conclusions: The association between recurrent oral sores caused by ill-fitting dentures and squamous cell carcinoma of the mouth in smokers is in agreement with the hypothesis that the chronic physical irritation of oral mucosa contributes to the topical carcinogenic effect of tobacco, which must be taken into careful consideration in the planning of dental services for adults and the elderly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Although the use of local flaps in conservative breast surgery (CBS) reconstruction is a reliable technique, little information has been available regarding outcome following the use of perforator flaps. The purpose of this study is to analyze the feasibility, surgical planning and outcome following CBS reconstruction with intercostal artery perforator (ICAP) flap. Patients/methods: Thirteen patients underwent CBS reconstructions with an ICAP flap. These flaps were raised from adjacent tissue located on the lateral and thoracic region and based on perforators originating from the costal and muscular segment of the intercostal vessels. The technique was indicated in patients with small/moderate volume breasts. Results: Mean time of follow-up was 32 months. Flap complications were evaluated and information on patient satisfaction were collected. 61.5 percent had tumors located in the lower-outer quadrants and 69.2 percent had tumors measuring 2 cm or less (T1). Complications occurred in 3 patients (23%), including wound dehiscence in 2 patients and fat necrosis in one. All cases were treated by conservative approach with a good result. No flap loss or wound infection were reported. 90 percent were either satisfied or very satisfied with their result. Conclusion: The ICAP flap is a reliable technique for immediate CBS reconstruction. The technique is advantageous because it does not require the use of muscle transfer, with minimum donor site morbidity. Success depends on patient selection, coordinated planning with the oncological surgeon and careful intra-operative management. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shiga-like toxin 2 (Stx2)-producing enterohemorrhagic Escherichia coli (referred to as EHEC or STEC) strains are the primary etiologic agents of hemolytic-uremic syndrome (HUS), which leads to renal failure and high mortality rates. Expression of Stx2 is the most relevant virulence-associated factor of EHEC strains, and toxin neutralization by antigen-specific serum antibodies represents the main target for both preventive and therapeutic anti-HUS approaches. In the present report, we describe two Salmonella enterica serovar Typhimurium aroA vaccine strains expressing a nontoxic plasmid-encoded derivative of Stx2 (Stx2 Delta AB) containing the complete nontoxic A2 subunit and the receptor binding B subunit. The two S. Typhimurium strains differ in the expression of flagellin, the structural subunit of the flagellar shaft, which exerts strong adjuvant effects. The vaccine strains expressed Stx2 Delta AB, either cell bound or secreted into the extracellular environment, and showed enhanced mouse gut colonization and high plasmid stability under both in vitro and in vivo conditions. Oral immunization of mice with three doses of the S. Typhimurium vaccine strains elicited serum anti-Stx2B (IgG) antibodies that neutralized the toxic effects of the native toxin under in vitro conditions (Vero cells) and conferred partial protection under in vivo conditions. No significant differences with respect to gut colonization or the induction of antigen-specific antibody responses were detected in mice vaccinated with flagellated versus nonflagellated bacterial strains. The present results indicate that expression of Stx2 Delta AB by attenuated S. Typhimurium strains is an alternative vaccine approach for HUS control, but additional improvements in the immunogenicity of Stx2 toxoids are still required.