76 resultados para weighing design
Resumo:
Background The protease-activated receptor 1 (PAR-1), the main platelet receptor for thrombin, represents a novel target for treatment of arterial thrombosis, and SCH 530348 is an orally active, selective, competitive PAR-1 antagonist. We designed TRA.CER to evaluate the efficacy and safety of SCH 530348 compared with placebo in addition to standard of care in patients with non-ST-segment elevation (NSTE) acute coronary syndromes (ACS) and high-risk features. Trial design TRA.CER is a prospective, randomized, double-blind, multicenter, phase III trial with an original estimated sample size of 10,000 subjects. Our primary objective is to demonstrate that SCH 530348 in addition to standard of care will reduce the incidence of the composite of cardiovascular death, myocardial infarction (MI), stroke, recurrent ischemia with rehospitalization, and urgent coronary revascularization compared with standard of care alone. Our key secondary objective is to determine whether SCH 530348 will reduce the composite of cardiovascular death, MI, or stroke compared with standard of care alone. Secondary objectives related to safety are the composite of moderate and severe GUSTO bleeding and clinically significant TIMI bleeding. The trial will continue until a predetermined minimum number of centrally adjudicated primary and key secondary end point events have occurred and all subjects have participated in the study for at least I year. The TRA.CER trial is part of the large phase III SCH 530348 development program that includes a concomitant evaluation in secondary prevention. Conclusion TRA.CER will define efficacy and safety of the novel platelet PAR-1 inhibitor SCH 530348 in the treatment of high-risk patients with NSTE ACS in the setting of current treatment strategies. (Am Heart J 2009; 158:327-34.)
Resumo:
We have designed, built, and tested an early prototype of a novel subxiphoid access system intended to facilitate epicardial electrophysiology, but with possible applications elsewhere in the body. The present version of the system consists of a commercially available insertion needle, a miniature pressure sensor and interconnect tubing, read-out electronics to monitor the pressures measured during the access procedure, and a host computer with user-interface software. The nominal resolution of the system is <0.1 mmHg, and it has deviations from linearity of <1%. During a pilot series of human clinical studies with this system, as well as in an auxiliary study done with an independent method, we observed that the pericardial space contained pressure-frequency components related to both the heart rate and respiratory rate, while the thorax contained components related only to the respiratory rate, a previously unobserved finding that could facilitate access to the pericardial space. We present and discuss the design principles, details of construction, and performance characteristics of this system.
Resumo:
Background: A 150 cm(3) pear-shaped gastric balloon with a 30 cm-long duodenal stem and a 7 g metallic weight at its distal end was designed and developed to facilitate weight loss by (a) delaying gastric emptying thus enhancing interprandial satiety, and (b) stimulating antral and duodenal receptors of satiation. Methods: Twenty-six patients (body mass index of 29 to 40 kg/m(2)) who failed to lose weight despite dietary intervention underwent endoscopic implantation of the balloon device. Patients were monitored for tolerance to the balloon, complications, weight loss, and compliance with a restricted caloric intake. Results: Six men and 20 women with a median body weight of 93.0kg (range, 73.5 to 119.9), median body mass index 34.3 kg/m(2) (range, 28.8 to 39.5) underwent balloon implantation for a median period of 4.0 months (range, 0.75 to 6.0). Twenty-two patients successfully complied with a 1250 to 1500 kcal daily diet restriction during the study period. Median weight reduction was 6.5 kg (range, 3.7 to 19.9). Patients with initial body weight of > 90 kg tended to loose more weight (8.1 kg) than patients weighing < 90 kg (4.5 kg) (P = 0.14). Nine patients with dwell times of 6 months lost 11.5 +/- 4.6 kg. The balloon malfunctioned in 4 patients (in I patient, the balloon leaked spontaneously but remained in the stomach and in 3 patients, the balloon migrated distally). Conclusions: Our novel balloon device may be effective in inducing weight loss by promoting compliance with a restricted caloric intake and is well tolerated due to its small size. Complications resulted from balloon rupture, which can be easily prevented by enhancements in design and use of alternative materials.
Resumo:
Background Benznidazole is effective for treating acute and chronic (recently acquired) Tryponosoma cruzi infection (Chagas` disease). Recent data indicate that parasite persistence plays a pivotal role in the pathogenesis of chronic Chagas` cardiomyopathy. However, the efficacy of trypanocidal therapy in preventing clinical complications in patients with preexisting cardiac disease is unknown. Study Design BENEFIT is a multicenter, randomized, double-blind, placebo-controlled clinical trial of 3,000 patients with Chagas` cardiomyopathy in Latin America. Patients are randomized to receive benznidazole (5 mg/kg per day) or matched placebo, for 60 days. The primary outcome is the composite of death; resuscitated cardiac arrest; sustained ventricular tachycardia; insertion of pacemaker or cardiac defibrillator; cardiac transplantation; and development of new heart failure, stroke, or systemic or pulmonary thromboembolic events. The average follow-up time will be 5 years, and the trial has a 90% power to detect a 25% relative risk reduction. The BENEFIT program also comprises a substudy evaluating the effects of benznidazole on parasite clearance and an echo substudy exploring the impact of etiologic treatment on left ventricular function. Recruitment started in November 2004, and >1,000 patients have been enrolled in 35 centers from Argentina, Brazil, and Colombia to date. Conclusion This is the largest trial yet conducted in Chagas` disease. BENEFIT will clarify the role of trypanocidal therapy in preventing cardiac disease progression and death.
Resumo:
Objective: To test the viability of a tracheal autotransplant, with an original technique using a prefabricated flap from a complete tracheal neovascularized segment (CTNVS) of the sternohyoid muscle anastomosed by a microsurgical technique. Study Design: An experimental study using dogs as an animal model. Methods: Ten mongrel dogs weighing 23 to 40 kg were divided into two groups: group I (control), five animals submitted to autotransplant of the CTNVS without a microsurgical vascular anastomosis; and group II, five dogs submitted to autotransplant of the CTNVS with a microsurgical vascular anastomosis. Results: All group I dogs developed respiratory insufficiency and died because of necrosis and stenosis of the autotransplanted CTNVS, whereas all group II dogs completed a minimum period of 90 days of observation without any clinical changes. Macro- and microscopic analysis revealed intact tracheal structures. Conclusions: The present clinical and morphological findings demonstrate that the CTNVS autotransplant is viable, when a microsurgical vascular anastomosis is used.
Resumo:
Objective To evaluate the extent sensory and motor blocks produced by the epidural injection of different volumes of 0.25% bupivacaine (Bu) with methylene blue (MB), in dogs. Study design Prospective experimental trial. Animals Twenty healthy adult mongrel dogs, weighing 9.9 +/- 1.9 kg. Methods Dogs were randomly allocated into one of four groups that received 0.2, 0.4, 0.6 or 0.8 mL kg-1 of an epidural solution containing 0.25% Bu and MB. Sensory block was evaluated against time by pinching the tail, hind limb interdigital web, toenail bases and the skin over the vertebral dermatomes. Motor block was assessed by ataxia, hind limb weight-bearing ability and by loss of muscle tone of the tail and pelvic limbs. Data were collected at 2, 5, 10, 15 and 30 minutes after the end of epidural injection. After the final time point, dogs were euthanatized and laminectomies were conducted to expose the extent of the dural dye staining. Results The volumes 0.2, 0.4, 0.6 and 0.8 mL kg-1 of 0.25% Bu and MB blocked a mean of 5, 14.2, 20.2 and 21 dermatomes, respectively. The extent of the senory block increased up to a volume of 0.6 mL kg-1. Motor block was longer-lasting and more intense than sensory block. Complete dyeing of the spinal cord with MB was achieved in some dogs at 0.4 mL kg-1 and all dogs at 0.6 mL kg-1. Conclusions The volume of anesthetic injected into the epidural space plays an important role in the quality of the epidural anesthesia. At 0.25%, bupivacaine provided an efficient sensory block at 0.6 mL kg-1. Clinical relevance Relatively high volumes (0.6 mL kg-1) of 0.25%, BU and MB were needed to produce an effective sensory and motor block caudal to the umbilicus, but all spinal cord segments were reached by MB at this dose.
Resumo:
Objective To evaluate the post-operative analgesic effect of metamizol (dipyrone) administered intravenously at three different doses (15 mg kg(-1), 25 mg kg(-1) and 35 mg kg(-1)) compared to placebo in dogs undergoing ovariohysterectomy. Study design Prospective, comparative, randomized. blinded trial. Animals Forty healthy bitches, aged 1-6 years, weighing 10-35 kg Methods The animals were randomly divided into four groups and received their respective treatments immediately after surgery: placebo group (0.9% saline solution), D15 group (metamizol 15 mg kg(-1) IV), D25 group (metamizol 25 mg kg(-1) IV), D35 group (metamizol 35 mg kg(-1) IV). The following variables were measured: sedation, pulse rate (PR). respiratory rate (f(R)). arterial blood pressure (ABP), plasma catecholamines. serum cortisol, blood urea nitrogen (BUN) and creatinine metabolites. albumin, alanine aminotransferase (ALT), alkaline phosphatase (ALP). hemogram. platelet counts and level of analgesia which was assessed by visual analog (VAS). descriptive and behavioral scales. Patients were monitored for 48 hours after the administration of the analgesic agent. Rescue analgesia (tramadol, 2 mg kg(-1), intramuscularly) was provided for animals with pain scores >= 4, as determined by the VAS or descriptive scale. Results The D25 and D35 groups showed equivalent post-operative analgesia, as shown by decreased pain scores, according to the three different pain scales, and fewer animals that required rescue analgesia. Significantly lower serum cortisol concentrations were observed in the D25 and D35 groups when compared to the placebo and D15 groups. No hematologic, renal, hepatic or clinical adverse effects were observed during the treatment. Conclusions and clinical relevance Metamizol administered intravenously at 25 or 35 mg kg(-1) can provide adequate post-operative analgesia in bitches undergoing ovariohysterectomy.
Resumo:
Objective To establish the correlation between the bispectral index (BIS) and different rates of infusion of propofol in dogs. Study design Prospective experimental trial. Animals Eight adult dogs weighing 6-20 kg. Methods Eight animals underwent three treatments at intervals of 20 days. Propofol was used for induction of anesthesia (10 mg kg(-1) IV), followed by a continuous rate infusion (CRI) at 0.2 mg kg(-1) minute(-1) (P2), 0.4 mg kg(-1) minute(-1) (P4) or 0.8 mg kg(-1) minute(-1) (P8) for 55 minutes. The BIS values were measured at 10, 20, 30, 40, and 50 minutes (T10, T20, T30, T40, and T50, respectively) after the CRI of propofol was started. Numeric data were submitted to analysis of variance followed by Tukey test (p < 0.05). Results The BIS differed significantly among groups at T40, when P8 was lower than P2 and P4. At T50, P8 was lower than P2. The electromyographic activity (EMG) in P2 and P4 was higher than P8 at T40 and T50. Conclusion An increase in propofol infusion rates decreases the BIS values and EMG.
Resumo:
Purpose: The aim of this research was to assess the dimensional accuracy of orbital prostheses based on reversed images generated by computer-aided design/computer-assisted manufacturing (CAD/CAM) using computed tomography (CT) scans. Materials and Methods: CT scans of the faces of 15 adults, men and women older than 25 years of age not bearing any congenital or acquired craniofacial defects, were processed using CAD software to produce 30 reversed three-dimensional models of the orbital region. These models were then processed using the CAM system by means of selective laser sintering to generate surface prototypes of the volunteers` orbital regions. Two moulage impressions of the faces of each volunteer were taken to manufacture 15 pairs of casts. Orbital defects were created on the right or left side of each cast. The surface prototypes were adapted to the casts and then flasked to fabricate silicone prostheses. The establishment of anthropometric landmarks on the orbital region and facial midline allowed for the data collection of 31 linear measurements, used to assess the dimensional accuracy of the orbital prostheses and their location on the face. Results: The comparative analyses of the linear measurements taken from the orbital prostheses and the opposite sides that originated the surface prototypes demonstrated that the orbital prostheses presented similar vertical, transversal, and oblique dimensions, as well as similar depth. There was no transverse or oblique displacement of the prostheses. Conclusion: From a clinical perspective, the small differences observed after analyzing all 31 linear measurements did not indicate facial asymmetry. The dimensional accuracy of the orbital prostheses suggested that the CAD/CAM system assessed herein may be applicable for clinical purposes. Int J Prosthodont 2010;23:271-276.
Resumo:
Purpose: The purpose of this study was to assess the influence of adhesive area delimitation on the microshear bond strength of different adhesives to dentin. Materials and Methods: Eighteen bovine incisors were sectioned and the exposed dentin surfaces were prepared with 600-grit SIC paper. These teeth were randomly divided into three groups, according to the adhesive to be applied: two-step etch-and-rinse Adper Single Bond 2 (3M ESPE), two-step self-etching Clearfil SE Bond (Kuraray), and one-step Clearfil S(3) Bond (Kuraray). On each dentin surface, 4 samples were built up with the composite resin Z100 (3M ESPE); on 2 of these, a suggested area delimitation technique was employed. After 24 h of storage in water at 37 degrees C, samples were subjected to the microshear bond strength test, and the failure modes were evaluated under optical and scanning electron microscopes. The obtained results were statistical analyzed using two-way ANOVA and Tukey`s test. Results: Groups without area delimitation presented significantly higher bond strength results (p < 0.05) and a higher incidence of cohesive failures. In these groups, fractures tended to occur beyond the limits of the actual adhesive area, while the area restriction technique succeeded in avoiding this phenomenon. The three adhesives performed similarly when area delimitation was employed (p > 0.05), but Clearfil S(3) Bond showed significantly higher bond strength results when no area delimitation was taken into account (p < 0.05). Conclusion: The extension of the adhesive area beyond the limits of the composite cylinder may play an important role in the results of microshear bond strength tests, while the suggested area delimitation technique may lead to less questionable outcomes.
Resumo:
Objective. The aim of this study was to evaluate the pH, calcium release, setting time, and solubility of two commercially available mineral trioxide aggregate (MTA) cements (white MTA Angelus and MTA Bio), and of three experimental cements (light-cured MTA, Portland cement with 20% bismuth oxide and 5% calcium sulfate, and an epoxy resin-based cement). Study design. For evaluation of pH and calcium ion release, polyethylene tubes with 1.0 mm internal diameter and 10.0 mm length were filled with the cements and immediately immersed in flasks containing 10 mL deionized water. After 3, 24, 72, and 168 hours, the tubes were removed and the water from the previous container was measured for its pH and calcium content with a pH meter and an atomic absorption spectrophotometer. For analysis of the setting time, Gilmore needles weighing 100 g and 456.5 g were used, in accordance with the American Society for Testing and Materials specification no. C266-03. Solubility of each cement was also tested. Results. All the cements were alkaline and released calcium ions, with a declining trend over time. After 3 hours, Portland cement + bismuth oxide and MTA Bio had the highest pH and light-cured MTA the lowest. After 1 week, MTA Bio had the highest pH and light-cured MTA and epoxy resin-based cement the lowest. Regarding calcium ion release, after 3 hours, Portland cement + bismuth oxide showed the highest release. After 1 week, MTA Bio had the highest. Epoxy resin-based cement and light-cured MTA had the lowest calcium release in all evaluation periods. Regarding setting times, white MTA Angelus and MTA Bio had the shortest, Portland cement + bismuth oxide had an intermediate setting time, and the epoxy resin-based cement had the longest. The materials that showed the lowest solubility values were the epoxy resin-based cement, Portland cement + bismuth oxide, and light-cured MTA. The highest solubility values were presented in white MTA Angelus and MTA Bio. Conclusions. The white MTA Angelus and MTA Bio had the shortest setting times, higher pH and calcium ion release, and the highest solubility. In contrast, the epoxy resin-based cement and light-cured MTA showed lower values of solubility, pH, and calcium ion release. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 250-256)
Resumo:
This study evaluated the effect of framework design on the fracture resistance of metal-ceramic implant-supported crowns. Screw-retained molar crowns with a screw access hole composed of metal or porcelain were compared to a cement-retained crown (control). For each group (n = 10), five crowns were subjected to dynamic loading (1,200,000 x 100 N x 2 Hz at 37 degrees C). Afterward, all specimens were loaded to failure using a universal testing machine. Significant differences could be established between the cement-and screw-retained groups (P <= .05), but no difference was found between the screw-retained groups and the specimens subjected to dynamic loading. Occlusal discontinuity of screw-retained crowns affects their resistance, and the metallic support on the screw access hole did not reinforce the crowns. Int J Prosthodont 2010;23:350-352.
Resumo:
Objectives: To evaluate the effect of framework design on the fatigue life and failure modes of metal ceramic (MC, Ni-Cr alloy core, VMK 95 porcelain veneer), glass-infiltrated alumina (ICA, In-Ceram Alumina/VM7), and veneered yttria-stabilized tetragonal zirconia polycrystals (Y-TZP, IPSe.max ZirCAD/IPS e.max,) crowns. Methods: Sixty composite resin tooth replicas of a prepared maxillary first molar were produced to receive crowns systems of a standard (MCs, ICAs, and Y-TZPs, n = 10 each) or a modified framework design (MCm, ICAm, and Y-TZPm, n = 10 each). Fatigue loading was delivered with a spherical steel indenter (3.18 mm radius) on the center of the occlusal surface using r-ratio fatigue (30-300 N) until completion of 10(6) cycles or failure. Fatigue was interrupted every 125,000 cycles for damage evaluation. Weibull distribution fits and contour plots were used for examining differences between groups. Failure mode was evaluated by light polarized and SEM microscopy. Results: Weibull analysis showed the highest fatigue life for MC crowns regardless of framework design. No significant difference (confidence bound overlaps) was observed between ICA and Y-TZP with or without framework design modification. Y-TZPm crowns presented fatigue life in the range of MC crowns. No porcelain veneer fracture was observed in the MC groups, whereas ICAs presented bulk fracture and ICAm failed mainly through the veneer. Y-TZP crowns failed through chipping within the veneer, without core fractures. Conclusions: Framework design modification did not improve the fatigue life of the crown systems investigated. Y-TZPm crowns showed comparable fatigue life to MC groups. Failure mode varied according to crown system. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
This study evaluated the stress levels at the core layer and the veneer layer of zirconia crowns (comprising an alternative core design vs. a standard core design) under mechanical/thermal simulation, and subjected simulated models to laboratory mouth-motion fatigue. The dimensions of a mandibular first molar were imported into computer-aided design (CAD) software and a tooth preparation was modeled. A crown was designed using the space between the original tooth and the prepared tooth. The alternative core presented an additional lingual shoulder that lowered the veneer bulk of the cusps. Finite element analyses evaluated the residual maximum principal stresses fields at the core and veneer of both designs under loading and when cooled from 900 degrees C to 25 degrees C. Crowns were fabricated and mouth-motion fatigued, generating master Weibull curves and reliability data. Thermal modeling showed low residual stress fields throughout the bulk of the cusps for both groups. Mechanical simulation depicted a shift in stress levels to the core of the alternative design compared with the standard design. Significantly higher reliability was found for the alternative core. Regardless of the alternative configuration, thermal and mechanical computer simulations showed stress in the alternative core design comparable and higher to that of the standard configuration, respectively. Such a mechanical scenario probably led to the higher reliability of the alternative design under fatigue.
Resumo:
This study evaluated the effect of core-design modification on the characteristic strength and failure modes of glass-infiltrated alumina (In-Ceram) (ICA) compared with porcelain fused to metal (PFM). Premolar crowns of a standard design (PFMs and ICAs) or with a modified framework design (PFMm and ICAm) were fabricated, cemented on dies, and loaded until failure. The crowns were loaded at 0.5 mm min(-1) using a 6.25 mm tungsten-carbide ball at the central fossa. Fracture load values were recorded and fracture analysis of representative samples were evaluated using scanning electron microscopy. Probability Weibull curves with two-sided 90% confidence limits were calculated for each group and a contour plot of the characteristic strength was obtained. Design modification showed an increase in the characteristic strength of the PFMm and ICAm groups, with PFM groups showing higher characteristic strength than ICA groups. The PFMm group showed the highest characteristic strength among all groups. Fracture modes of PFMs and of PFMm frequently reached the core interface at the lingual cusp, whereas ICA exhibited bulk fracture through the alumina core. Core-design modification significantly improved the characteristic strength for PFM and for ICA. The PFM groups demonstrated higher characteristic strength than both ICA groups combined.