75 resultados para mottled teeth
Resumo:
Aim It is well reported in the scientific literature that there is a high level of periodontal disease and lower caries prevalence in Down Syndrome (DS) individuals, when compared with age-matched non DS individuals. This study was conducted to investigate the process of dental caries in DS children. Materials and methods In this study the following parameters were considered: oral hygiene habits, levels of Streptococcus mutans (SM) and Lactobacillus spp. (LB), Modified Gingival Index (MGI), and Simplified Oral Hygiene Index (OHI-S). A case group with DS children (n=69) and a control group of non DS children (n=69) were formed to perform this study Dental caries severity was determined using the DMFT index. Samples of non-stimulated saliva were collected to determine the Lactobacillus spp levels. For SM levels, MSB agar plates were used. Results The findings revealed that the case group attended, dental check-ups more frequently brushed their teeth more times per day, flossed less, and also more frequently had SM levels classified as ""high count"". The MGI was higher and the OHI-S was lower than the control group (p<0.001). Conclusion No significant differences were found between the DMFT indexes of children from the two groups (p=0.345). The logistic regression analysis showed that in the case group, age, MGI, and SM count were positively related to dental caries (p<0.05).
Resumo:
Introduction: The aim of the present study was to determine the disinfection of preparations carried out by using the Protaper or MTwo system in canals infected with Enterococcus faecalis. Methods: Twenty-eight distobuccal canals of upper molars were used, in which the canals were sterilized after being enlarged to #20 file and then contaminated with an inoculation of a culture of E. faecalis. After the incubation period, bacterial samples were collected and were seeded on plates for analysis of colony-forming units (CFU)/mL. The teeth were divided into 2 groups according to the rotary system used for instrumentation; 2 noninstrumented teeth served as the control group. Then bacterial samples were collected and were seeded on plates for analysis of CFU/mL again. The data obtained were evaluated by the Wilcoxon and Mann-Whitney U tests. Results: Bacterial reduction was 81.94% and 84.29%, respectively, in Pro Taper and Mtwo systems, and there was no statistically significant difference (P > .05). Conclusions: Both systems, Pro Taper and Mtwo, reduced the amount of bacteria in the mechanical disinfection of the root canal system, demonstrating that they are suitable for this purpose. (J Endod 2010;36:1238-1240)
Resumo:
We report the use of optical coherence tomography (OCT) to detect and quantify demineralization process induced by S. mutans biofilm in third molars human teeth. Artificial lesions were induced by a S. mutans microbiological culture and the samples (N = 50) were divided into groups according to the demineralization time: 3, 5, 7, 9, and 11days. The OCT system was implemented using a light source delivering an average power of 96 mu W in the sample arm, and spectral characteristics allowing 23 mu m of axial resolution. The images were produced with lateral scans step of 10 pan and analyzed individually. As a result of the evaluation of theses images, lesion depth was calculated as function of demineralization time. The depth of the lesion in the root dentine increased from 70 pm to 230,urn (corrected by the enamel refraction index, 1.62 @ 856 nm), depending of exposure time. The lesion depth in root dentine was correlated to demineralization time, showing that it follows a geometrical progression like a bacteria growth law. [GRAPHICS] Progression of lesion depth in root dentine as function of exposure time, showing that it follows a geometrical progression like a bacteria growth law(C) 2009 by Astro Ltd. Published exclusively by WILEY-VCH Verlag GmbH & Co. KGaA
Resumo:
Rationale: Previous studies have used myeloperoxidase (MPO) as an inflammatory marker to estimate the accumulation of neutrophils in inflamed regions. Objective: The aim of this experimental study was to quantify the levels of MPO related to experimental periodontal disease in rats. Methods: Periodontal disease was induced in a group of rats using placement of a ligature around molar teeth. A group of rats without ligature placement served as a control. Measurements were made on the 3rd, 7th, 15th and 30th day from baseline. Gingival tissues were taken for quantification of MPO levels by ELISA. Results: The rats with induced periodontal disease showed statistically higher MPO levels (p 0.05) when compared to control rats. A significant increase in the levels of MPO released on days 7 and 30 was observed, with higher levels in the group with induced periodontitis. Conclusion: The levels of MPO were found to be higher in rats with induced periodontal disease, confirming the hypothesis that MPO may serve as an inflammatory marker for periodontitis.
Resumo:
Purpose: The aim of the present paper was to determine the effect of different types of ionizing radiation on the bond strength of three different dentin adhesive systems. Materials and Methods: One hundred twenty specimens of 60 human teeth (protocol number: 032/2007) sectioned mesiodistally were divided into 3 groups according to the adhesives systems used: SB (Adper Single Bond Plus), CB (Clearfil SE Bond) and AP (Adper Prompt Self-Etch). The adhesives were applied on dentin and photo-activated using LED (Lec 1000, MMoptics, 1000 mW/cm(2)). Customized elastomer molds (0.5 mm thickness) with three orifices of 1.2 mm diameter were placed onto the bonding areas and filled with composite resin (Filtek Z-250), which was photo-activated for 20 s. Each group was subdivided into 4 Subgroups for application of the different types of ionizing radiation: ultraviolet radiation (UV), diagnostic x-ray radiation (DX), therapeutic x-ray radiation (TX) and without irradiation (control group, CG). Microshear tests were carried out (Instron, model 4411), and afterwards the modes of failure were evaluated by optical and scanning electron microscope and classified using 5 scores: adhesive failure, mixed failures with 3 significance levels, and cohesive failure. The results of the shear bond strength test were submitted to ANOVA with Tukey`s test and Dunnett`s test, and the data from the failure pattern evaluation were analyzed with the Mann Whitney test (p = 0.05). Results: No change in bond strength of CB and AP was observed after application of the different radiation types, only SB showed increase in bond strength after UV (p = 0.0267) irradiation. The UV also changed the failure patterns of SB (p = 0.0001). Conclusion: The radio-induced changes did not cause degradation of the restorations, which means that they can be exposed to these types of ionizing radiation without weakening the bond strength.
Resumo:
The purpose of this study was to comparatively evaluate the response of human pulps after cavity preparation with different devices. Deep class I cavities were prepared in sound mandibular premolars using either a high-speed air-turbine handpiece (Group 1) or an Er: YAG laser (Group 2). Following total acid etching and the application of an adhesive system, all cavities were restored with composite resin. Fifteen days after the clinical procedure, the teeth were extracted and processed for analysis under optical microscopy. In Group 1 in which the average for the remaining dentin thickness (RDT) between the cavity floor and the coronal pulp was 909.5 mu m, a discrete inflammatory response occurred in only one specimen with an RDT of 214 mu m. However, tissue disorganization occurred in most specimens. In Group 2 (average RDT = 935.2 mu m), the discrete inflammatory pulp response was observed in only one specimen (average RDT = 413 mu m). It may be concluded that the high-speed air-turbine handpiece caused greater structural alterations in the pulp, although without inducing inflammatory processes.
Resumo:
We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 +/- 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.
Resumo:
Dentin hypersensitivity is a common condition associated with high dental pain. A new LED-based (light emitting diode) light source has been used as an experimental tool in some studies. Purpose: The main objective was to compare these two light sources emitting in the same spectral band (red from 625 to 660 nm) to promote pain relief. Material and methods: A total of 6 sessions were accomplished, being three irradiation sessions and three follow-up sessions. This single-blind study compared a control group (Placebo) and two other groups with different equipments: low laser intensity treatment (LILT) and a light emitting diode system treatment (LEDT). Results: The results showed that there is no statistical difference between LILT and LEDT groups, however, both were better than control group (p=0.01) in terms of treatment efficiency; there is no difference between the second and the third sessions for both treatment, it means that the third session was not necessary; finally, the improvement at the end of the entire research (follow up care of 30 days) was very expressive in comparison to pre-treatment situation for all teeth (p=0.01). Conclusion: LILT and LEDT were equally effective to treat dentine hypersensitivity, a 3rd treatment session was not necessary/two sessions are enough.
Resumo:
The purpose of this study was to evaluate the effectiveness of different light-curing units on the bond strength (push-out) of glass fiber posts in the different thirds of the root (cervical, middle and apical) with different adhesive luting resin systems (dual-cure total-etch; dual-cured and self-etch bonding system; and dual-cure self-adhesive cements), Disks of the samples (n = 144) were used, with approximately 1 mm of thickness of 48 bovine roots restored with glass fiber posts, that were luted with resin cements photo-activated by halogen LCU (QTH, Optilux 501) and blue LED (Ultraled), with power densities of 600 and 550 mW/cm(2), respectively. A universal testing machine (MTS 810 Material Test System) was used with a 1 mm diameter steel rod at cross-head speed of 0.5 mm/min until post extrusion, with load cell of 50 kg, for evaluation of the push-out strength in the different thirds of each sample. The push-out strength values in kgf were converted to MPa and analyzed through Analysis of Variance and Tukey`s test, at significance level of 5%. The results showed that there were no statistical differences between the QTH and LED LCUs. The self-adhesive resin cement had lower values of retention. The total-etch and self-adhesive system resin cements seem to be a possible alternative for glass fiber posts cementation into the radicular canal and the LED LCU can be applied as an alternative to halogen light on photo-activation of dual-cured resin cements.
Resumo:
The aim of this study was to evaluate the hypothesis that low-level laser therapy (LLLT) 688 nm and 785 nm accelerate dentin barrier formation and repair process after traumatic pulp exposure. The sample consisted of 45 premolars of capuchin monkeys (Cebus apella) with pulp exposure Class V cavities. All premolars were treated with calcium hydroxide (Ca(OH)(2)), divided in groups of 15 teeth each, and analyzed on 7(th), 25(th), and 60(th) day. Group GI - only Ca(OH)(2), GIF- laser 688 nm, and GIII - laser 785 nm. Laser beam was used in single and punctual dose with the parameters: continuous, 688 nm and 785 nm wavelength, tip`s area of 0.00785 cm(2), power 50 mW, application time 20 s, dose 255 J/cm(2), energy 2 J. Teeth were capped with Ca(OH)(2), Ca(OH)(2) cement and restored with amalgam. All groups presented pulp repair. On 25(th) day the thickness of the formed dentin barrier was different between the groups GI and GII (p < 0.05) and between groups GI and GIII (p < 0.01). On 60(th) day there was difference between GI and GIII (p < 0.01). It may be concluded that, LLLT 688 nm and 785 nm accelerated dentin barrier formation and consequently pulp repair process, with best results using infrared laser 785 nm. (c) 2009 by Astro Ltd. Published exclusively by WLLEY-VCH Verlag GmbH & Co. KGaA
Resumo:
Three species of chondrichthyans are reported from conglomeratic sandstone at the base of the Lower Permian (Artinskian) Irati Formation (Parana Basin) near Rio Claro, Sao Paulo State, Brazil. The fossils include: 1) dispersed teeth of the petalodont ltapyrodus punctatus Silva Santos 1990, first described from the Permian (Artinskian) Pedra do Fogo Formation, Parnaiba Basin, Northeast Brazil; 2) a new species of tooth of the Order Orodontiformes; and 3) a new species of finspine of the Order Ctenacanthiformes. These fossils occur in an allochthonous assemblage of vertebrate remains including other Chondrichthyes, Xenacanthiformes and cladodonts, paleonisciform bony fish, and tetrapods. This discovery is a significant contribution to the sparse record of South American Chondrichthyes from the Early Permian and raises questions regarding the paleoenvironmental adaptations among these fish within Paleozoic basins of Brazil at this time. (C) 2010 International Association for Gondwana Research. Published by Elsevier B.V. All rights reserved.
Resumo:
Statement of the problem: The performance of self-etch systems on enamel is controversial and seems to be dependent on the application technique and the enamel preparation. Purpose of the Study: To examine the effects of conditioning time and enamel surface preparation on bond strength and etching pattern of adhesive systems to enamel. Materials and Methods: Ninety-six teeth were divided into 16 conditions (N = 6) in function of enamel preparation and conditioning time for bond strength test. The adhesive systems OptiBond FL (Kerr, Orange, CA, USA), OptiBond SOLO Plus (Kerr), Clearfil SE Bond (Kuraray, Osaka, Japan), and Adper Prompt L-Pop (3M ESPE, St. Paul, MN, USA) were applied on unground or ground enamel following the manufacturers` directions or doubling the conditioning time. Cylinders of Filtek Flow (0.5-mm height) were applied to each bonded enamel surface using a Tygon tube (0.7 mm in diameter; Saint-Gobain Corp., Aurora, OH, USA). After storage (24 h/37 degrees C), the specimens were subjected to shear force (0.5 mm/min). The data were treated by a three-way analysis of variance and Tukey`s test (alpha = 0.05). The failure modes of the debonded interfaces and the etching pattern of adhesives were observed using scanning electron microscopy. Results: Only the main factor ""adhesive"" was statistically significant (p < 0.001). The lowest bond strength value was observed for OptiBond FL. The most defined etching pattern was observed for 35% phosphoric acid and for Adper Prompt L-Pop. Mixed failures were observed for all adhesives, but OptiBond FL showed cohesive failures in resin predominantly. Conclusions: The increase in the conditioning time as well as the enamel pretreatment did not provide an increase in the resin-enamel bond strength values for the studied adhesives. CLINICAL SIGNIFICANCE The surface enamel preparation and the conditioning time do not affect the performance of self-etch systems to enamel. (J Esthet Restor Dent 20:322-336, 2008)
Resumo:
The objective of the study was to evaluate saliva flow rate, buffer capacity, pH levels, and dental caries experience (DCE) in autistic individuals, comparing the results with a control group (CG). The study was performed on 25 noninstitutionalized autistic boys, divided in two groups. G1 composed of ten children, ages 3-8. G2 composed of 15 adolescents ages 9-13. The CG was composed of 25 healthy boys, randomly selected and also divided in two groups: CG3 composed of 14 children ages 4-8, and CG4 composed of 11 adolescents ages 9-14. Whole saliva was collected under slight suction, and pH and buffer capacity were determined using a digital pHmeter. Buffer capacity was measured by titration using 0.01 N HCl, and the flow rate expressed in ml/min, and the DCE was expressed by decayed, missing, and filled teeth (permanent dentition [DMFT] and primary dentition [dmft]). Data were plotted and submitted to nonparametric (Kruskal-Wallis) and parametric (Student`s t test) statistical tests with a significance level less than 0.05. When comparing G1 and CG3, groups did not differ in flow rate, pH levels, buffer capacity, or DMFT. Groups G2 and CG4 differ significantly in pH (p = 0.007) and pHi = 7.0 (p = 0.001), with lower scores for G2. In autistic individuals aged 3-8 and 9-13, medicated or not, there was no significant statistical difference in flow rate, pH, and buffer capacity. The comparison of DCE among autistic children and CG children with deciduous (dmft) and mixed/permanent decayed, missing, and filled teeth (DMFT) did not show statistical difference (p = 0.743). Data suggest that autistic individuals have neither a higher flow rate nor a better buffer capacity. Similar DCE was observed in both groups studied.
Resumo:
Lead (Pb) poisoning is preventable but continues to be a public health problem in several countries. Measuring Pb in the surface dental enamel (SDE) using microbiopsies is a rapid, safe, and painless procedure. There are different protocols to perform these microbiopsies, but the reliability of dental enamel lead levels (DELL) determination is dependent upon biopsy depth (BD). It is established that DELL decrease from the outermost superficial layer to the inner layer of dental enamel. The aim of this study was to determine DELL obtained by two different microbiopsy techniques on SDE termed protocol I and protocol II. Two consecutive enamel layers were removed from the same subject group (n = 138) for both protocols. Protocol I consisted of a biopsied site with a diameter of 4 mm after the application of 10 l HCl for 35 s. Protocol II involved a biopsied site of 1.6 mm diameter after application of 5 l HCl for 20 s. The results demonstrated that there were no significant differences for BD and DELL between homologous teeth using protocol I. However, there was a significant difference between DELL in the first and second layers using both protocols. Further, the BD in protocol II overestimated DELL values. In conclusion, SDE analyzed by microbiopsy is a reliable biomarker in protocol I, but the chemical method to calculate BD in protocol II appeared to be inadequate for measurement of DELL. Thus, DELL could not be compared among studies that used different methodologies for SDE microbiopsies.
Resumo:
Purpose: The aim of this in situ double-blind randomised crossover study was to investigate the effect of calcium (Ca) pre-rinse on the composition of plaque and on enamel prior to the use of fluoride (F) dentifrice. Materials and Methods: During four phases (14 days each) of this study, 10 volunteers had agreed to wear dental appliances containing two healthy bovine enamel blocks. A fresh solution containing 20% weight/volume (w/v) sucrose was dripped on the enamel blocks ex vivo for 5 min three times a day. Subsequently, the appliances were replaced in the mouth, and the volunteers rinsed their mouth with 10 mL of a Ca (150 mmol/L) or a placebo rinse (1 min). In sequence, a slurry (1:3 w/v) of F (1030 ppm) or placebo dentifrice was dripped onto the blocks ex vivo for 1 min. During this time, the volunteers brushed their teeth with the respective dentifrice. The appliances were replaced in the mouth, and the volunteers rinsed their mouth with water. The plaque formed on the blocks was analysed for F and Ca. The enamel demineralisation as well as the incorporation of F on enamel was evaluated by cross-sectional microhardness and alkali-soluble F analysis, respectively. Data were tested using analysis of variance (P < 0.05). Results: The Ca pre-rinse prior to the use of the F dentifrice led to a three- and sixfold increase in the plaque F and Ca concentrations, respectively. It also did not have any additive effect on the F content on the enamel and the demineralisation of the enamel, in comparison with the use of F dentifrice alone. Conclusions: A Ca lactate rinse used prior to the F dentifrice was able to change the mineral content in the plaque, but it was unable to prevent enamel demineralisation.