82 resultados para In situ study
Resumo:
High doses of diazepam reduce the inflammatory paw edema in rats. This effect was attributed to an action of diazepam on the Translocator Protein (TSPO). We evaluated the effects of diazepam (10 mg/kg, intraperitoneally) on leukocyte rolling and migration. In carrageenan-induced acute inflammation, diazepam decreased the interaction of leukocytes with endothelial cells (rolling) and the number of leukocytes in the mesentery (migration). RU486 (antagonist of glucocorticoid receptors) reduced the effects of diazepam on leukocyte rolling and migration, suggesting a participation of endogenous corticosteroids. We also showed that the effects of diazepam on leukocyte-endothelium interactions are mediated by nitric oxide (NO), since prior treatment with l-arginine (precursor of NO) partially precludes the inhibitory effects of diazepam; conversely, pretreatment with L-NAME (false substrate of the NO synthase) somewhat potentiates the effects of diazepam. The pathways that underlie the effects of diazepam remain to be further elucidated, but we believe that both local and systemic mechanisms may overlap to explain the influence of diazepam on leukocyte-endothelium interactions.
Resumo:
Alternative treatment for recurrent labial infection by herpes simplex virus (HSV) have been considered. The aim of this study was to evaluate the effectiveness of laser phototherapy in prevention and reduction of severity of labial manifestations of herpes labialis virus. Seventy-one patients, divided into experimental (n = 41) and control (n = 30) groups were followed up for 16 months. Patients in the control group were treated topically with aciclovir and patients in the experimental group were subjected to laser phototherapy (one session per week, 10 weeks): 780 nm, 60 mW, 3.0 J/cm(2) or 4.5 J/cm(2) on healthy (no HSV-1 infection) and affected (with HSV-1 infection) tissues. Patients in the experimental group presented a significant decrease in dimension of herpes labialis lesions (P = 0.013) and inflammatory edema (P = 0.031). The reduction in pain level (P = 0.051) and monthly recurrences (P = 0.076) did not reach statistical significance. This study represents an in vivo indication that this treatment should be further considered as an effective alternative to therapeutic regimens for herpes labialis lesions.
Resumo:
The comparison of chamomile and corticosteroids for treating ulcers was done in vitro and in vivo. The experimental groups were: control; chamomile recutita; triamcinolone acetonide and clobetasol propionate. For the in vitro study the cell viability of fibroblasts cultured for 24 h in media conditioned by the substances was obtained by the MITT reduction analysis. For the in vivo study, 125 male rats were submitted to experimental ulcers treated or not (control) by the substances tested. At 1, 3, 5, 7 and 14 days later 5 animals of each group were sacrificed. The lesions were analyzed by means of clinical observation and histological wound-healing grading. Data were compared by ANOVA (p <= 0.05). All experimental groups presented positive cell viability in 24 h. The cultures treated with chamomile presented the smallest cell viability. All animals of the chamomile group exhibited complete wound healing 9 days before the other groups. Complete repaired lesions were observed after 5 days of treatment only in the chamomile group. Animals treated with chamomile presented significantly faster wound healing in comparison to those treated with corticosteroids. Based on the conditions of this study, we concluded that chamomile in comparison to corticosteroids promotes faster wound healing process. Copyright (C) 2008 John Wiley & Sons, Ltd.
Resumo:
Objectives: The diagnosis of caries lesions is still a matter of concern in dentistry. The diagnosis of dental caries by digital radiography has a number of advantages over conventional radiography; however, this method has not been explored fully in the field of paediatric dentistry. This in vitro research evaluated the accuracy of direct digital radiography compared with visual inspection and conventional radiography in the diagnosis of occlusal caries lesions in primary molars. Methods: 50 molars were selected and evaluated under standardized conditions by 2 previously calibrated examiners according to 3 diagnostic methods (visual inspection, conventional radiography and direct digital radiography). Direct digital radiographs were obtained with the Dixi3 system (Planmeca, Helsinki, Finland) and the conventional radiographs with InSight film (Kodak Eastman Co., Rochester, NY). The images were scored and a reference standard was obtained histologically. The interexaminer reliability was calculated using Cohen`s kappa test and the specificity, sensitivity and accuracy of the methods were calculated. Results: Examiner reliability was good. For lesions limited to the enamel, visual inspection showed significantly higher sensitivity and accuracy than both radiographic methods, but no significant difference was found in specificity. For teeth with dentinal caries, no significant differences were found for any parameter when comparing visual and radiographic evaluation. Conclusions: Although less accurate than the visual method for detecting caries lesions confined to the enamel, the direct digital radiographic method is as effective as conventional radiographic examination and visual inspection of primary teeth with occlusal caries when the dentine is involved. Dentomaxillofacial Radiology (2010) 39, 362-367. doi: 10.1259/dmfr/22865872
Resumo:
The purpose of this study was to evaluate the characteristics of diseased root surfaces treated by the association of scaling and the application of Carisolv. Twenty-four uniradicular periodontally involved teeth were used in this study The teeth were divided randomly into three groups: eight teeth were scaled and root planed until there was a complete visible removal of calculus (group 1), Carisolv was applied on the root surfaces of eight teeth twice for 30 seconds before scaling with a sharp curette (group 2), and eight teeth received the same treatment as in group 2 but with a blunt curette (group 3). Specimens were examined using scanning electron microscopy The superficial aspect of the roots from group 1 presented scratches that mirrored the curette cutting edge, and the smear layer completely covered the surface. Root surfaces from groups 2 and 3 also presented a smear layer that covered the surface completely but it was somewhat smoother than group 1. The use of Carisolv as an adjunct to scaling and root planing presented no advantage for smear layer removal over scaling alone, suggesting that no benefit is obtained by the use of Carisolv during periodontal mechanical treatment. (Int J Periodontics Restorative Dent 2011;31:91-95.)
Resumo:
Objective. The aim of this study was to compare Profile .04 taper series 29 instruments and hand files for gutta-percha removal. Study design. Twenty maxillary central incisors with a single straight canal were instrumented and filled. The teeth were divided into 2 groups of 10 specimens each, according to gutta-percha removal techniques: Group 1- Profile series 29 and Group 2- hand files and solvent. The amount of time for gutta-percha removal and the number of fractured instruments were evaluated. Radiographs were taken and the teeth were grooved longitudinally and split. The area of residual debris was measured using computer software. Results. The time for filling material removal was significantly shorter when Profile series 29 was used (P = .00). Regarding cleanliness, there were no statistical differences in the teeth halves evaluations (P = .05). Hand instruments cleaned the canals significantly better than Profiles, in the radiographic analysis considering the whole canal. Overall, the radiographic analysis showed a smaller percentage of residual debris than the teeth halves analysis. Conclusion. The Profile series 29 instruments proved to be faster than hand instruments in removing root filling materials; however, hand instruments yielded better root canal cleanliness. Some residual debris was not visualized by radiographs. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: e46-e50)
Resumo:
Objective: To evaluate whether the type of cola drink (regular or diet) could influence the wear of enamel subjected to erosion followed by brushing abrasion, Method and !Materials: Ten volunteers wore intraoral devices that each had eight bovine enamel blocks divided into four groups; ER, erosion with regular cola; EAR, erosion with regular cola plus abrasion; EL, erosion with light cola; and EAL, erosion with light cola plus abrasion, Each day for 1 week, half of each device was immersed in regular cola for 5 minutes, Then, two blocks were brushed using a fluoridated toothpaste and electric toothbrush for 30 seconds four times daily, Immediately after, the other half of the device was subjected to the same procedure using a light cola, The pH, calcium, phosphorus, and fluoride concentrations of the colas were analyzed using standard procedures, Enamel alterations were measured by profilometry. Data were tested using two-way ANOVA and Bonferroni test (P < .05), Results: Regarding chemical characteristics, light cola presented pH 3.0, 13.7 mg Ca/L, 15.5 mg P/L, and 0.31 mg F/L, while regular cola had pH 2.6, 32.1 mg Ca/L, 1:8.1 mg P/L, and 0.26 mg F/L, The light cola promoted less enamel loss (EL, 0.36 pm; EAL, 0.39 pm) than its regular counterpart (ER, 0.72 pm; EAR, 0.95 pm) for both conditions, There was not a significant difference (P > .05) between erosion and erosion plus abrasion for light cola, However, for regular cola, erosion plus abrasion resulted in higher enamel loss than erosion alone,.nclusion: The data suggest that light cola promoted less enamel wear even when erosion was followed by brushing abrasion, (Quintessence Int 2011;42:xxx-xx)()
Resumo:
Purpose: Nonpassive fit frameworks are believed to lead to implant overload and consequently loss of osseointegration. This is one of the most commonly reported failures of implant prostheses. In an ideal situation of passive fit, when torque is applied to bring the abutment-cylinder interface together some amount of deformation can be expected, and it should be homogeneous along the periphery of the abutment. The aim of this study was to verify the amount of abutment deformation that can be expected when a free-standing cylinder is screwed into place. This could give insight into what should be accepted as passive fit. Materials and Methods: Strain gauges were bonded to the sides of five standard abutments that had machined palladium-silver cylinders or cobalt-chromium cast cylinders screwed into place. Measurements were taken to verify the deformation at each site. Results: Values of abutment deformation after abutment screw tightening ranged from -127.70 to -590.27 mu epsilon. The deformation recorded for palladium-silver prosthetic cylinder tightening ranged from 56.905 to -381.50 mu epsilon (mean: 173.298 mu epsilon) and from -5.62638 to -383.86 mu epsilon ( mean: 200.474 mu epsilon) for cobalt-chromium cylinders. There was no statistically significant difference among the two groups. Conclusion: Both abutment screw tightening and prosthetic cylinder screw tightening result in abutment deformation, which is compressive most of the time. Int J Prosthodont 2009; 22: 391-395.
Resumo:
Objective The purpose of this study was to evaluate the retention force of an O-ring attachment system in different inclinations to the ideal path of insertion, using devices to compensate angulations. Material and methods Two implants were inserted into an aluminum base, and ball attachments were screwed to implants. Cylinders with O-rings were placed on ball attachments and connected to the test device using positioners to compensate implant angulations (0 degrees, 7 degrees, and 14 degrees). Plexiglass bases were used to simulate implant angulations. The base and the test device were positioned in a testing apparatus, which simulated insertion/removal of an overdenture. A total of 2900 cycles, simulating 2 years of overdenture use, were performed and 36 O-rings were tested. The force required for each cycle was recorded with computer software. Longitudinal sections of ball attachment-positioner-cylinder with O-rings of each angulation were obtained to analyze the relationship among them, and O-ring sections tested in each angulation were compared with an unused counterpart. A mixed linear model was used to analyze the data, and the comparison was performed by orthogonal contrasts (alpha=0.05). Results At 0 degrees, the retention force decreased significantly over time, and the retention force was significantly different in all comparisons, except from 12 to 18 months. When the implants were positioned at 7 degrees, the retention force was statistically different at 0 and 24 months. At 14 degrees, significant differences were found from 6 and 12 to 24 months. Conclusions Within the limitations of this study, it was concluded that O-rings for implant/attachments perpendicular to the occlusal plane were adequately retentive over the first year and that the retentive capacity of O-ring was affected by implant inclinations despite the proposed positioners. To cite this article:Rodrigues RCS, Faria ACL, Macedo AP, Sartori IAM, de Mattos MGC, Ribeiro RF. An in vitro study of non-axial forces upon the retention of an O-ring attachment.Clin. Oral Impl. Res. 20, 2009; 1314-1319.doi: 10.1111/j.1600-0501.2009.01742.x.
Resumo:
Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in other implant connection systems. The purpose of this study was to evaluate the effects of mechanical loading and repeated insertion/removal cycles on the torque loss of abutments with internal tapered connections. Sixty-eight conical implants and 68 abutments of two types were used. They were divided into four groups: groups 1 and 3 received solid abutments, and groups 2 and 4 received two-piece abutments. In groups 1 and 2, abutments were simply installed and uninstalled; torque-in and torque-out values were measured. In groups 3 and 4, abutments were installed, mechanically loaded and uninstalled; torque-in and torque-out values were measured. Under mechanical loading, two-piece abutments were frictionally locked into the implant; thus, data of group 4 were catalogued under two subgroups (4a: torque-out value necessary to loosen the fixation screw; 4b: torque-out value necessary to remove the abutment from the implant). Ten insertion/removal cycles were performed for every implant/abutment assembly. Data were analyzed with a mixed linear model (P <= 0.05). Torque loss was higher in groups 4a and 2 (over 30% loss), followed by group 1 (10.5% loss), group 3 (5.4% loss) and group 4b (39% torque gain). All the results were significantly different. As the number of insertion/removal cycles increased, removal torques tended to be lower. It was concluded that mechanical loading increased removal torque of loaded abutments in comparison with unloaded abutments, and removal torque values tended to decrease as the number of insertion/removal cycles increased. To cite this article:Ricciardi Coppede A, de Mattos MdaGC, Rodrigues RCS, Ribeiro RF. Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study.Clin. Oral Impl. Res. 20, 2009; 624-632.doi: 10.1111/j.1600-0501.2008.01690.x.
Resumo:
The objective of this study was to verify if differences in the design of internal hex (IH) and internal conical (IC) connection implant systems influence fracture resistance under oblique compressive forces. Twenty implant-abutment assemblies were utilized: 10 with IH connections and 10 with IC connections. Maximum deformation force for IC implants (90.58 +/- 6.72 kgf) was statistically higher than that for IH implants (83.73 +/- 4.94 kgf) (P = .0182). Fracture force for the IH implants was 79.86 +/- 4.77 kgf. None of the IC implants fractured. The friction-locking mechanics and the solid design of the IC abutments provided greater resistance to deformation and fracture under oblique compressive loading when compared to the IH abutments. Int J Prosthodont 2009;22:283-286.
Resumo:
Background Several studies have reported certain bone morphogenic proteins (BMPs) to have positive effects on bone generation Although some investigators have studied the effects of human recombinant BMP (rhBMP-2) in sinus augmentation in sheep, none of these studies looked at the placement of implants at the time of sinus augmentation Furthermore, no literature could be found to report on the impact that different implant systems, as well as the positioning of the implants had on bone formation if rhBMP-2 was utilized in sinus-lift procedures Purpose The aim of this study was to compare sinus augmentation with rhBMP-2 on a poly-D, L-lactic-co-glycolic acid gelatine (PLPG) sponge with sinus augmentation with autologous pelvic cancellous bone in the maxillary sinus during the placement of different dental Implants Materials and methods Nine adult female sheep were submitted to bilateral sinus-floor elevation In one side (test group) the sinus lift was performed with rhBMP-2 on a PLPG-sponge, while the contralateral side served as the control by using cancellous bone from the iliac crest Three different implants (Branemark (R), 31 (R) and Straumann (R)) were inserted either simultaneously with the sinus augmentation or as a two staged procedure 6 weeks later The animals were sacrificed at 6 and 12 weeks for histological and histomorphometrical evaluations during which bone-to-implant contact (BIC) and bone density (BD) were evaluated Results BD and BIC were significantly higher at 12 weeks in the test group if the Implants were placed at the time of the sinus lift (p < 0 05) No difference was observed between the different implant systems or positions Conclusions The use of rhBMP-2 with PLPG-sponge increased BIC as well as BD in the augmented sinuses if compared to autologous bone Different implant systems and positions of the implants had no effect on BIC or BD (C) 2010 European Association for Cranio-Maxillo-Facial Surgery
Resumo:
Purpose: The purpose of this study was to evaluate, in vitro, the contamination of toothbrushes and pacifiers by Streptococcus mutans, and the efficacy of microwave and chlorhexidine for their disinfection. Methods: Sixty pacifiers and 60 toothbrushes were contaminated with S mutans and then divided into groups according to the disinfection protocol: Group 1-chlorhexidine solution; Group 2-microwave sterilization; and Group 3-sterile tap water. The devices were evaluated microbiologically as to the formation of S mutans colonies/biofilms and were examined by scanning electron microscopy. The results were submitted for statistical analysis by Friedman`s test at a 5% significance level. Results: The results of both types of evaluation showed a large number of S mutans colonies/biofilms after spraying with sterile tap water, and chlorhexidine spraying and microwaving were effective in eliminate colonies/biofilms. Groups 1 and 2 were statistically similar to each other (P>.05) and differed significantly from Group 3 (P<.05). Conclusions: The 0.12% chlorhexidine solution spray and 7 minutes of microwave irradiation were effective for disinfection of pacifiers and toothbrushes. (Pediatr Dent 2011;33:10-3) Received July 29, 2009 I Last Revision January 26, 2010 I Accepted March 10, 2010
Resumo:
In this work, the diurnal evolution of the radiation balance components over the tropical Atlantic Ocean is described and analysed. The analysis is based on measurements carried Out on board a Brazilian Navy ship during the observational campaign of the FluTuA Project (`Fluxos Turbulentos sobre o Atlantico`), from 15 to 23 May 2002. The observations indicated that the albedo responds its expected to atmospheric attenuation effects with a diurnal evolution similar to the Fresnel albedo. In general, the observed longwave radiation values agreed better with the estimated values obtained without longwave reflection. In agreement with the literature, the average surface emissivity was around 0.97. The net radiation, estimated from published equations for albedo, atmospheric transmissivity and surface emissivity, agreed with the observations, indicating that these parameters are representative of the radiometric properties of the air-sea interface in the region between Natal (6 degrees S, 35.2 degrees W) and the Sao Pedro and Sao Paulo Archipelago (1 degrees N, 29.3 degrees W). Copyright (C) 2008 Royal Meteorological Society
Resumo:
This study focuses on morphological and molecular data analyses, misidentifications, and phylogenetic inconsistencies regarding Bradypus variegatus (the brown-throated sloth) and B. tridactylus (the pale-throated sloth). Misidentifications were recorded on 75 of 313 museum specimens of Bradypus. Almost 90% of the misidentified specimens were B. variegatus from north-central Brazil, erroneously attributed to B. tridactylus. These misidentified specimens are reported in taxonomic reviews as the southernmost records of B. tridactylus. A history of confusing nomenclature regarding sloth species exists, and these particular misidentifications could be attributable to the similarity in face and throat color between B. variegatus from north-central Brazil and B. tridactylus. The molecular phylogeny of morphologically confirmed sloth specimens exhibits 2 monophyletic lineages representing B. variegatus and B. tridactylus. The split time between these 2 lineages was estimated at 6 million years ago (mya), contradicting previous studies that estimated this divergence to be 0.4 mya. Taxonomic inconsistencies were detected when comparing the molecular phylogeny to previously published DNA sequences ascribed to B. tridactylus. Misidentification or introgression could underlie such phylogenetic incongruities. Regardless of their causes, these discrepancies lead to misstatements regarding geographic distribution, phylogeny, and taxonomy of B. variegatus and B. tridactylus.