67 resultados para External electronic poling
Resumo:
Objective. The aim of this study was to evaluate the precision of working length determination of 3 electronic apex locators (EALs): Root ZX, RomiApex D-30, and Ipex at 0.0 mm, at the apical foramen (AF), and at 1.0 mm short of the AF. Methodology. Thirty-eight mandibular premolars had their real lengths previously determined. Electronic measurements were determined at 1.0 mm, followed by measurements at 0.0 mm, performed in triplicate. Results. Precision of devices at 1.0 mm and 0.0 mm were: 94.7% and 97.4%, respectively (Root ZX); 78.9% and 97.4% (RomiApex D-30); and 76.3% and 97.4% (Ipex). Although no statistical differences were observed between the EALs at 0.0, at 1.0 mm Root ZX performed significantly better than the others. Conclusion. The EALs had acceptable precision when measuring the working length at the AF. However, when used at levels short of the AF, only Root ZX did not suffer a significant negative effect on precision. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e57-e61)
Resumo:
Introduction: The aim of this study was to compare the influence of preflaring on the accuracy of 4 electronic apex locators (EALs): Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex Locator, and Apex DSP. Methods: Forty extracted teeth were preflared by using S1 and SX ProTaper instruments. The working length was established by reducing 1 mm from the total length (TL). The ability of the EALs to detect precise (-1 mm from TL) and acceptable (-1+/-0.5 mm from TL) measurements in unflared and preflared canals was determined. Results: The precise and acceptable (P/A) readings in unflared canals for Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex and Apex DSP were 50%/97.5%, 47.5%/95%, 50%/97.5%, and 45%/67.5%, respectively. For preflared canals, the readings were 75%/97.5%, 55%/95%, 75%/97.5%, and 60%/87.5%, respectively. For precise criteria, the preflared procedure increased the percentage of accurate electronic readings for the Root ZX and the Mini Apex Locator (P < .05). For acceptable criteria, no differences were found among Root ZX, Elements Diagnostic Unit and Apex Locator, and Mini Apex Locator (P > .05). Fisher test indicated the lower accuracy for Apex DSP (P < .05). Conclusions: The Root ZX and the Mini Apex Locator devices increased significantly the precision to determine the real working length after the preflaring procedure. All the EALs showed an acceptable determination of the working length between the ranges of+/-0.5mm except for the Apex DSP device, which had the lowest accuracy. (J Endod 2009;35:1300-1302)
Resumo:
Objective: To describe the clinical, speech, hearing, and imaging findings in three members of a Brazilian family with Saethre-Chotzen syndrome (SCS) who presented some unusual characteristics within the spectrum of the syndrome. Design: Clinical evaluation was performed by a multidisciplinary team. Direct sequencing of the polymerase chain reaction amplified coding region of the TWIST1 gene, routine and electrophysiological hearing evaluation, speech evaluation, and imaging studies through computed tomography (CT) scan and magnetic resonance imaging (MRI) were performed. Results: TWIST1 gene analysis revealed a Pro136His mutation in all patients. Hearing evaluation showed peripherial and mixed hearing loss in two of the patients, one of them with severe unilateral microtia. Computed tomography scan showed structural middle ear anomalies, and MRI showed distortion of the skull contour as well as some of the brain structures. Conclusions: We report a previously undescribed TWIST1 gene mutation in patients with SCS. There is evidence that indicates hearing loss (conductive and mixed) can be related both with middle ear (microtia, high jugular bulb, and enlarged vestibules) as well as with brain stem anomalies. Here we discuss the relationship between the gene mutation and the clinical, imaging, speech, and hearing findings.
Resumo:
The purpose of this study was to evaluate the influence of stress and anxiety on the pressure pain threshold (PPT) of masticatory muscles and on the subjective pain report. Forty-five women, students, with mean age of 19.75 years, were divided into two groups: group 1:29 presenting with masticatory myofascial pain (MFP), according to the Research Diagnostic Criteria for Temporomandibular Disorders and group 2: 16 asymptomatic controls. An electronic algometer registered the pain thresholds on four different occasions throughout the academic year. To measure levels of stress, anxiety and pain, the Beck Anxiety Inventory, Lipp Stress Symptoms Inventory and Visual Analog Scale (VAS) were used. Three-way anova and Tukey`s tests were used to verify differences in PPT between groups, times and sites. Levels of anxiety and VAS were compared using Mann-Whitney test, while Friedman`s test was used for the within-groups comparison at different times (T1 to T4). The chi-squared and Cochran tests were performed to compare groups for the proportion of subjects with stress (alpha = 0.05). Differences in PPT recordings between time (P = 0.001) and sites (P < 0.001) were detected. Higher levels of anxiety and lower PPT figures were detected at T2 (academic examination) (P = 0.001). There was no difference between groups for anxiety and stress at any time (P > 0.05). The MFP group also has shown significant increase of VAS at the time of academic examination (P < 0.001). External stressors such as academic examinations have a potential impact on masticatory muscle tenderness, regardless of the presence of a previous condition such as masticatory myofascial pain.
Resumo:
Audiometry is the main way with which hearing is evaluated, because it is a universal and standardized test. Speech tests are difficult to standardize due to the variables involved, their performance in the presence of competitive noise is of great importance. Aim: To characterize speech intelligibility in silence and in competitive noise from individuals exposed to electronically amplified music. Material and Method: It was performed with 20 university students who presented normal hearing thresholds. The speech recognition rate (SRR) was performed after fourteen hours of sound rest after the exposure to electronically amplified music and once again after sound rest, being studied in three stages: without competitive noise, in the presence of Babble-type competitive noise, in monotic listening, in signal/ noise ratio of + 5 dB and with the signal/ noise ratio of 5 dB. Results: There was greater damage in the SRR after exposure to the music and with competitive noise, and as the signal/ noise ratio decreases, the performance of individuals in the test also decreased. Conclusion: The inclusion of competitive noise in the speech tests in the audiological routine is important, because it represents the real disadvantage experienced by individuals in daily listening.
Resumo:
Objective: To assess the temperature variation in the cervical, middle and apical thirds of root external wall, caused by 980-nm diode laser irradiation with different parameters. Methods: The roots of 90 canines, had their canals instrumented and were randomly distributed into 3 groups (n = 30) according to the laser potency (1.5 W, 3.0 W and 5.0 W). Each group was subdivided into 3 (n = 10) according to the frequency (CM, 100 Hz and 1000 Hz), and each subgroup divided into 2 (n = S): dried canal or filled with distilled water. The maximum temperature values were collected by 3 thermocouples located at each third of the root external wall and recorded by digital thermometers. Results: The groups irradiated in the continuous mode (CM) presented the highest values (11.82 +/- 5.78), regardless of the canals were dry or not, which were statistically different (p < 0.01) from those obtained with 100 Hz (6.22 +/- 3.64) and 1000 Hz (6.00 +/- 3.36), which presented no statistical difference between them (p > 0.01). The groups irradiated with 5.0 W presented the greatest temperature variation (12.15 +/- 5.14), followed by 3.0 W (7.88 +/- 3.92) and 1.5 W (4.02 +/- 2.16), differing between them (p < 0.01). The cervical third of the root presented the highest temperature rises (9.68 +/- 5.80), followed by the middle (7.66 +/- 4.87) and apical (6.70 +/- 4.23), with statistical difference among them (p < 0.01). After 30 s from the end of irradiation, all the specimens presented temperature variation lower than 10 degrees C. Conclusions: Application of 980-nm diode laser in the root, at 1.5 W in all operating modes, and 3.0 W, in the pulsed mode, for 20 s, can safely be used in endodontic treatment, irrespective of the presence of humidity. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
The aim of this in vitro study was to evaluate bacterial leakage along the implant-abutment interface under unloaded conditions. Twelve premachined abutments with plastic sleeves and 12 dental implants were used in this study. Prior to tests of bacterial leakage, samples from the inner parts of the implants were collected with sterile microbrushes to serve as negative controls for contamination. After casting, the abutments were tightened to 32 Ncm on the implants. The assemblies were immersed in 2.0 mL of human saliva and incubated for 7 days. After this period, possible contamination of the internal parts of the implants was evaluated using the DNA Checkerboard method. Microorganisms were found in the internal surfaces of all the implants evaluated. Aggregatibacter actinomycetemcomitans and Capnocytophaga gingivalis were the most incident species. No microorganisms were found in the samples recovered from the implants before contamination testing (negative control). Bacterial species from human saliva may penetrate the implant-abutment interface under unloaded conditions. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:782-787