89 resultados para ultrassonografia ocular


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To determine whether implantation of an aspherical intraocular lens (IOL) results in reduced ocular aberrations and improved contrast sensitivity after cataract surgery without critical reduction of depth of focus. DESIGN: Double-blinded, randomized, prospective study. METHODS: In an intraindividual study of 25 patients with bilateral cataract, an aspherical IOL (Akreos Advanced Optic [AO]; Bausch & Lomb, Inc., Rochester, New York, USA) was implanted in one eye and a spherical IOL (Akreos Fit; Bausch & Lomb, Inc) in the fellow eye. Higher-order aberrations with a 5- and 6-mm pupil were measured with a dynamic retinoscopy aberrometer at 1 and 3 months after surgery. Uncorrected and best-corrected visual acuity and contrast sensitivity under mesopic and photopic conditions also were measured. Distance-corrected near and intermediate visual acuity were studied as a measurement of depth of focus. RESULTS: There was no statistically significant difference between eyes in uncorrected and best-corrected visual acuity at I and 3 months after surgery. There was a statistically significant between-group difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. The Akreos AO group obtained statistically significant lower values of higher-order aberrations and spherical aberration with 5- and 6-mm pupils compared with the Akreos Fit group (P < .05). There was no significant difference in distance-corrected near and intermediate visual acuity between both groups. CONCLUSIONS: Aspherical aberration-free Akreos AO IOL induced significantly less higher-order aberrations and spherical aberration than the Akreos Fit. Contrast sensitivity was better under mesopic conditions with the Akreos AO with similar results of depth of focus. (Am J Ophthalmol 2010;149:383-389. (C) 2010 by Elsevier Inc. All rights reserved.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To study the oculometric parameters of hyperopia in children with esotropic amblyopia, comparing amblyopic eyes with fellow eyes. Methods: Thirty-seven patients (5-8 years old) with bilateral hyperopia and esotropic amblyopia underwent a comprehensive ophthalmic examination, including cycloplegic refraction, keratometry and A-scan ultrasonography. Anterior chamber depth, lens thickness, vitreous chamber depth and total axial length were recorded. The refractive power of the crystalline lens was calculated using Bennett`s equations. Paired Student`s t-tests were used to compare ocular biometric measurements between amblyopic eyes and their fellow eyes. The associations of biometric parameters with refractive errors were assessed using Pearson correlation coefficients and linear regression. Multivariable models including axial length, corneal power and lens power were also constructed. Results: Amblyopic eyes were found to have significantly more hyperopic refraction, less corneal power, greater lens power, shorter vitreous chamber depth and shorter axial length, despite similar anterior chamber depth and lens thickness. The strongest correlation with refractive error was observed for the axial length/corneal radius ratio (r(36) = -0.92, p < 0.001 for amblyopic and r(36) = 0.87, p < 0.001 for fellow eyes). Axial length accounted for 39.2% (R(2)) of the refractive error variance in amblyopic eyes and 35.5% in fellow eyes. Adding corneal power to the model increased R(2) to 85.7% and 79.6%, respectively. A statistically significant correlation was found between axial length and corneal power, indicating decreasing corneal power with increasing axial length, and they were similar for amblyopic eyes (r(36) = 0.53,p < 0.001) and fellow eyes (r(36) = -0.57, p < 0.001). A statistically significant correlation was also found between axial length and lens power, indicating decreasing lens power with increasing axial length (r(36) = -0.72, p < 0.001 for amblyopic eyes and r(36) = -0.69, p < 0.001 for fellow eyes). Conclusions: We observed that the correlation among the major oculometric parameters and their individual contribution to hyperopia in esotropic children were similar in amblyopic and non-amblyopic eyes. This finding suggests that the counterbalancing effect of greater corneal and lens power associated with shorter axial length is similar in both eyes of patients with esotropic amblyopia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To determine whether implantation of an intraocular lens (IOL) with an aspheric surface (Akreos AO, Bausch & Lomb Inc) results in reduced ocular aberrations (spherical aberration) and improved Strehl ratio and modulation transfer function (MTF) after cataract surgery. METHODS: In an intraindividual, randomized, double-masked, prospective study of 50 eyes (25 patients) with bilateral cataract, an IOL with modified anterior and posterior surfaces (Akreos AO) was implanted in one eye and a biconvex IOL with spherical surfaces (Akreos Fit, Bausch & Lomb Inc) implanted in the fellow eye. Ocular aberrations, Strehl ratio, and MTF curve with 4.5-, 5.0-, and 6.0-mm pupils were measured with a NIDEK OPD-Scan dynamic retinoscopy aberrometer 3 months after surgery. Uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively) were also measured. RESULTS: No statistically significant difference was noted between eyes in postoperative UDVA and CDVA at 1 month. At 3 months, the Akreos AO IOL group obtained statistically significant lower values of higher order and spherical aberrations with 4.5-, 5.0-, and 6.0-mm pupil diameters than the Akreos Fit IOL group (P<.05). The value of Strehl ratio was statistically significantly higher in eyes with the Akreos AO IOL for 4.5- and 6.0-mm pupils (P<.05). The MTF curve was better in the Akreos AO IOL group in 4.5-, 5.0-, and 6.0-mm pupils (P<.05). CONCLUSIONS: The aspheric Akreos AO IOL induced significantly less spherical aberration than the Akreos Fit IOL for 4.5-, 5.0-, and 6.0-mm pupils. Modulation transfer function and Strehl ratio were also better in eyes implanted with the Akreos AO IOL than the Akreos Fit. [J Refract Surg. 2011;27(4):287-292.] doi:10.3928/1081597X-20100714-01

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Most epidemiological studies with Wegener`s granulomatosis (WG) patients are based on populations from the Northern hemisphere, whereas very few studies have been conducted in Southern hemisphere populations, particularly from South America. The authors performed a large retrospective, demographic study including clinical and laboratory profiles of 134 consecutive WG patients seen at one Brazilian center from 1999 to 2009. Mean age at initial WG diagnosis was 43.4 +/- 15.5 years, and mean disease duration was 8.6 +/- 6.6 years. Sixty-four (47.8%) patients were male and a total of 113 (84.3%) subjects were white. Ear/nose/throat involvement occurred in 85.8%. The classic lung and renal involvement were observed in 77.6% and 75.4%, respectively, followed by ocular (35.8%), musculoskeletal (33.4%), cutaneous (29.1%), neurological (20.1%), cardiac (11.2%), and genitourinary involvement in 2.2% of cases. Cytoplasmic pattern-antineutrophil cytoplasmic antibody was detected in 83 (61.9%) cases. Ten (7.5%) individuals presented limited forms of WG. Classic therapy with corticosteroids and cyclophosphamide was used in 97 cases (72.4%). There were no cases of tuberculosis or Pneumocystis jiroveci pneumonia, but cutaneous herpes zoster occurred in eight (6.0%) individuals. There were 29 deaths (21.6%). Eighteen patients died of septic shock (mainly bacterial pneumonia), whereas four died of alveolar hemorrhage, four of myocardial infarction, and three of other causes. In summary, our data from a very large retrospective and descriptive study mirrored the main clinical features of WG described in other countries, demonstrating that they may serve as a reference for South American populations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Tessier no. 5 facial cleft is an extremely rare congenital malformation. Only 26 cases have been described In the English-language literature. The cleft begins In the upper lip just medial to the oral commissure, extending across the cheek as a groove ending at the junction of the middle and lateral thirds of the lower eyelid. The bone Involvement usually Includes an alveolar cleft in the premolar region, extends across the maxilla lateral to the Infraorbital nerve, up to the infraorbital rim and orbital floor. The goals of the surgical procedure Include reconstructing the lower eyelid, repositioning the lateral canthus, closure of the labiomaxillary cleft, and restoration of the skeletal continuity (including the orbital floor defect) with bone grafts. We present six patients with the Tessier no. 5 facial cleft who have been treated in our combined centers and discuss the surgical options and difficulties faced in the reconstruction of this rare and challenging craniofacial malformation. To date, we have treated six patients (two with bilateral and four with unilateral clefts). Three of the patients with unilateral clefting had an associated no. 4 cleft and one patient with a bilateral cleft had an associated no. 3 cleft. This paper represents the largest series to date documenting surgery for patients with the Tessier no. 5 facial cleft.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Animal models of diseases are extremely important in the study of the physiopathogenesis of human diseases and for testing novel therapeutic interventions. The present study aimed to develop an animal model that simulates human allergic conjunctivitis and to study how allergic response may be influenced by the allergen dose used for immunization and by genetic factors. Methods: Sixty C57Bl/6 mice and 60 BALB/c mice were immunized with placebo, or 5 mu g or 500 mu g of allergen derived from Dermatophagoides pteronyssinus. After ocular challenge, the mice were examined in order to clinically verify the occurrence or not of conjunctivitis. Material obtained from animals was used for total and specific IgE and IgG1 dosage, for assays of Der p-specific lymphocyte proliferation and supernatant cytokine dosage, and for histopathological evaluation of conjunctiva. Results: We developed a murine model of allergic conjunctivitis induced by D. pteronyssinus. The model is similar to human disease both clinically and according to laboratory findings. In mouse, conjunctivitis was associated with a Th2 cytokine profile. However, IL-10 appeared to be involved with disease blockade. Mice of different strains have distinct immune responses, depending on the sensitization dose. Conclusions: The murine model developed is suitable for the study of immunopathogenesis and as a template for future therapies. Using BALB/c and C57BL/6 mice, we demonstrated that genetic factors play a role in determining susceptibility and resistance, as well as in establishing the allergen concentration needed to induce or to block disease development.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Beh double dagger et`s disease (BD) is a multisystem chronic inflammatory disorder characterized by oral and genital ulceration and ocular involvement. Recurrent oral and genital ulcers are the most common symptoms of BD and occur in more than 80% of patients. The treatments of these disease manifestations include colchicine, corticosteroids and immunosuppressive drugs in severe cases. Anti-TNF-alpha therapy may be useful in refractory severe BD, particularly for ocular, central nervous system, gastrointestinal and refractory mucocutaneous lesions. During a 2-year period, 280 patients suffering from rheumatic diseases received anti-TNF-alpha agents at the infusion center of our University Hospital. Two patients (0.7%) presented BD; one of them had celiac disease as well, with recalcitrant mucocutaneous lesions that were not responsive to immunosuppressive drugs. We reported those patients who were successfully treated with infliximab and adalimumab, despite their late response.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the effects of oral azithromycin in patients with posterior blepharitis. Methods: Twenty-six eyes of 13 patients with posterior blepharitis diagnosed by a qualified ophthalmologist were enrolled in this study. Patients were instructed to use oral azithromycin 500 mg per day for 3 days in 3 cycles with 7-day intervals. Subjective clinical outcomes were graded and scored 1 day before and 30 days after the end of the treatment (53 days after initiating the treatment) based on severity scores of: (1) eyelid debris; (2) eyelid telangiectasia; (3) swelling of the eyelid margin; (4) redness of the eyelid margin; and (5) ocular mucus secretion. For the assessment of global efficacy, patients were asked by the investigator to rate the subjective symptoms (eyelid itching, ocular itching, eyelid hyperemia, ocular hyperemia, ocular mucus secretion, photophobia, foreign body sensation, and dry eye sensation) on a scale of 0 (no symptoms) to 5 (severe symptoms). Break-up time, Schirmer I test, corneal fluorescein staining score, and rose bengal staining score were also performed in all patients. Results: All clinical outcomes scoring showed statistically significant improvement after oral azithromycin, except for eyelid swelling. Average subjective symptom grading improved statistically after treatment with oral azithromycin, except for eyelid hyperemia, photophobia, and foreign body sensation. Average tear film break-up time values showed statistically significant improvement after the treatment with oral azithromycin. No statistically significant improvement was observed on average values of Schirmer I test, corneal fluorescein staining score, and rose bengal staining score. Conclusions: The combination of multiple clinical parameters shown in this study supports the clinical efficacy of pulsed oral azithromycin therapy for the management of posterior blepharitis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the additive effect of dorzolamide/timolol fixed combination in patients under monotherapy with latanoprost. Patients and Methods: In this prospective, 4-week, randomized, open-label controlled clinical trial, patients with open-angle glaucoma or ocular hypertension, which presented at least 15% intraocular pressure (IOP) reduction after a minimum period of 15 days of monotherapy with latanoprost and whose IOP level was considered above the established target-IOP level were randomized to receive fixed combination of timolol/dorzolamide twice daily in one of eyes. The fellow eye was kept under monotherapy and was included in the control group. A modified diurnal tension curve (mDTC) followed by the water drinking test were performed in the baseline and week 4 visits to evaluate IOP profile between groups. Results: Forty-nine per-protocol patients were analyzed. After latanoprost monotherapy run-in period, IOP levels were significantly reduced (P<0.001) in both control and study groups to 15.34 +/- 2.96 mm Hg and 15.24 +/- 2.84 mm Hg (30.8% and 32.2% IOP reduction, respectively; P=0.552). At week 4, mean baseline diurnal IOP levels were 15.60 +/- 3.09 and 14.44 +/- 3.03 (7.4% difference; P=0.01). Mean baseline IOP modified diurnal tension curve peak after latanoprost run-in period were 17.47 +/- 3.68 mm Hg and 17.02 +/- 3.35 mm Hg (control and study eyes, respectively; P=0.530). At week 4 visit, mean water-drinking test peaks were significantly reduced in the study eye group in comparison with the control group: 19.02 +/- 3.81 mm Hg and 20.39 +/- 4.19 mm Hg, respectively (6.7% reduction; P=0.039). Conclusions: In our sample, dorzolamide 2%/timolol 0.5% fixed combination as add-on therapy in patients with open-angle glaucoma or ocular hypertension under monotherapy with latanoprost with IOP already in mid-teens levels may further enhance pressure reduction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the correlation between intraocular pressure (IOP) rise, ocular pulse amplitude (OPA), and choroidal thickness (ChT) during the water drinking test (WDT). Primary open-angle glaucoma (POAG) patients were submitted to the WDT followed by serial IOP measurements using dynamic contour tonometry (DCT), Goldman tonometry (GAT), and ChT measurements using ultrasonographic A and B-scan (USG). A control group not submitted to the test was also evaluated using DCT, GAT, and USG. Intraclass correlation coefficient (ICC) was calculated in the control group in order to assess the reproducibility of measurements. Spearman`s coefficient (rho) was used to assess the correlation between the variables. Thirty eyes were included in the study. There was a significant IOP rise during the WDT using both GAT and DCT (p < 0.001). The OPA and ChT measurements also increased significantly (p < 0.001). Spearman`s correlation between the OPA values and ChT measurements was significant and moderate (rho = 0.40, p = 0.005). The average increase of OPA and ChT measurements occurred 15 min before the IOP rise. There was a significant increase of OPA and ChT measurements followed by an IOP rise during the WDT. Increased choroidal volume due to hemodynamic forces may be enrolled in the mechanism of IOP elevation during this stress test.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To compare the ability of Subjective assessment of optic nerve head (ONH) and retinal nerve fiber layer (RNFL) by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec Inc), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg. Germany), and scanning laser polarimetry (GDx enhanced corneal compensation; Carl Zeiss Meditec Inc, Dublin, CA) in discriminating glaucomatous and normal eyes. Methods: Sixty-one glaucomatous and 57 normal eyes or 118 subjects Were included in the study. Three independent general ophthalmologists and I glaucoma expert evaluated ONH stereo-photographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons or areas under these curves (aROCs) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Results: Best parameter from each technique showed larger aROC (Stratus OCT RNFL 0.92; Stratus OCT ONH vertical integrated area = 0.86; Stratus OCT macular thickness = 0.82; GDx enhanced corneal compensation = 0.91, HRT3 global cup-to-disc ratio = 0.83; HRT3 glaucoma probability score numeric area score 0.83) compared with stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared with stereophoto grading by general ophthalmologists, The combination Of Subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with Subjective assessment of the optic disc by a glaucoma expert (29.5% vs. 19.7%, respectively). Conclusions: Diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by It glaucoma expert, Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To analyze the influence of thermal partial punctal occlusion on the ocular surface of dry eye related to Sjogren syndrome. Material and Methods: Thirty-seven eyes of 19 patients (3 male and 16 female; 49.11 +/- 14.33 years old) with keratoconjunctivitis sicca were enrolled in this study. Superior and inferior partial occlusion were performed in both eyes under topical anesthesia using thermal cautery with a sterile tip to obtain lacrimal punctum smaller than 0.5 mm. Schirmer I, break-up-time, diameter of lacrimal puncta, corneal fluorescein, and rose Bengal staining scores were analyzed before and after 24 weeks and after 24 months of the procedure. All measurements were performed under controlled climate. Results: The average lacrimal punctum diameter before the procedure was 0.65 +/- 0.134 mm. All lacrimal puncta were successfully reduced to less than 0.5 mm after 4 weeks of the procedure. The average Schirmer I test values improved statistically after 24 weeks and maintained stable after 24 months. Average break-up-time, rose Bengal, and fluorescein staining score values improved statistically after 24 weeks and improved even more after 24 months. Average Schirmer I test, break-up-time, rose Bengal, and fluorescein staining scores showed significant improvement (p < 0.0001) after 24 months of partial thermal punctal occlusion. Conclusion: Our study showed that reducing the punctum diameter to 0.5 mm can improve vital staining scores, break-up-time, and Schirmer I test in dry eye related to Sjogren syndrome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To compare the efficacy and tolerability of the fixed combination of timolol maleate 0.5%/brimonidine tartrate 0.2% versus fixed combination of timolol maleate 0.5%/dorzolamide 2% in patients with elevated intraocular pressure (IOP) over 8 weeks. Patients and Methods: This 8-week, multicentric. interventional, randomized, open-label, parallel group study was conducted Lit 4 centers in Brazil and 1 center in Argentina. Patients with open-angle glaucoma or ocular hypertension were randomized to receive bilaterally fixed combination of brimonidine/timolol maleate 0.5% or fixed combination of dorzolamide 2%/timolol 0.5% twice daily at 8:00 AM and 8:00 PM. A modified diurnal tension curve (8:00 AM 10:30 AM, 02:00 PM, and 4:00 PM) followed by the water drinking test (WDT), which estimates IOP peak of diurnal tension curve, were performed in the baseline and week-8 visits. Adverse events data were recorded at each visit. Results: A total of 210 patients were randomized (brimonidine/timolol, n = 111; dorzolamide/timolol, n = 99). Mean baseline IOP was 23.43 +/- 3.22 mm Hg and 23.43 +/- 4.06 mm Hg in the patients treated with brimonidine/timolol and dorzolamide/timolol, respectively (P = 0.993). Mean diurnal IOP reduction after 8 weeks were 7.02 +/- 3.06 mm Hg and 6.91 +/- 3.67 mm Hg. respectively (P = 0.811). The adjusted difference between groups (analysis of covariance) Lit week 8 was not statistically significant (P = 0.847). Mean baseline WDT peak was 27.79 +/- 4.29 mm Hg in the brimonidine/timolol group and 27.68 +/- 5.46 mm Hg in the dorzolamide/timolol group. After 8 weeks of treatment, mean WDT peaks were 20.94 +/- 3.76 mm Hg (P < 0.001) and 20.98 +/- 4.19 (P < 0.001), respectively. The adjusted difference between groups (analysis of covariance) was not statistically significant (P = 0.469). No statistical difference in terms of adverse events was Found between groups. Conclusions: Both fixed combinations were capable of significantly reducing the mean diurnal IOP, mean diurnal peak, and mean WDT peak after 8 weeks of treatment. Also, both fixed combinations are well tolerated with few side effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

to test the ability of frequency-doubling technology (FDT) perimetry to detect dysthyroid optic neuropathy (DON). Fifteen eyes of 15 patients with DON and 15 healthy control eyes were studied. Eligible eyes had a diagnosis of DON based on visual field abnormalities on standard automated perimetry and had visual acuity better than 20/30. FDT testing was performed using both the C-20-5 screening test and the C-20 full-threshold test. Normal and DON eyes were compared with regard to FDT mean sensitivity. Sensitivity ranges were 40.0%-86.7% for the screening test, and 53.3%-100.0% (total deviation) and 20.0-93.3 (pattern deviation) for the C-20 threshold test. The corresponding specificity ranges were 86.7-100.0, 33.3-93.3, and 26.7-100.0, respectively. The best sensitivity/specificity ratios were for one abnormal point depressed < 5% in the screening test (86.7%/86.7%), one point depressed < 1% in the total deviation analysis (80.0%/86.7%), and one point depressed < 2% in the pattern deviation analysis (80.0%/86.7%). DON eyes presented significantly lower than normal average sensitivity in the central, pericentral, and peripheral areas. FDT perimetry is a useful screening tool for DON in eyes with normal or only slightly reduced visual acuity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To determine intraocular pressure (IOP)-dependent and IOP-independent variables associated with visual field (VF) progression in treated glaucoma. Design: Retrospective cohort of the Glaucoma Progression Study. Methods: Consecutive, treated glaucoma patients with repeatable VF loss who had 8 or more VF examinations of either eye, using the Swedish Interactive Threshold Algorithm (24-2 SITA-Standard, Humphrey Field Analyzer II; Carl Zeiss Meditec, Inc, Dublin, California), during the period between January 1999 and September 2009 were included. Visual field progression was evaluated using automated pointwise linear regression. Evaluated data included age, sex, race, central corneal thickness, baseline VF mean deviation, mean follow-up IOP, peak IOP, IOP fluctuation, a detected disc hemorrhage, and presence of beta-zone parapapillary atrophy. Results: We selected 587 eyes of 587 patients (mean [SD] age, 64.9 [13.0] years). The mean (SD) number of VFs was 11.1 (3.0), spanning a mean (SD) of 6.4 (1.7) years. In the univariable model, older age (odds ratio [OR], 1.19 per decade; P = .01), baseline diagnosis of exfoliation syndrome (OR, 1.79; P = .01), decreased central corneal thickness (OR, 1.38 per 40 mu m thinner; P < .01), a detected disc hemorrhage (OR, 2.31; P < .01), presence of beta-zone parapapillary atrophy (OR, 2.17; P < .01), and all IOP parameters (mean follow-up, peak, and fluctuation; P < .01) were associated with increased risk of VF progression. In the multivariable model, peak IOP (OR, 1.13; P < .01), thinner central corneal thickness (OR, 1.45 per 40 mu m thinner; P < .01), a detected disc hemorrhage (OR, 2.59; P < .01), and presence of beta-zone parapapillary atrophy (OR, 2.38; P < .01) were associated with VF progression. Conclusions: IOP-dependent and IOP-independent risk factors affect disease progression in treated glaucoma. Peak IOP is a better predictor of progression than is IOP mean or fluctuation.