76 resultados para retinal contour


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conclusion: The cochlear implant was beneficial as an attempt to restore hearing and improve communication abilities in this patient with profound sensorineural hearing loss secondary to Susac syndrome. Objective: To report the audiological outcomes of cochlear implantation (CI) in a young woman with Susac syndrome after a 6-month follow-up period. Susac syndrome is a rare disorder. It is clinically characterized by a typical triad of sensorineural deafness, encephalopathy, and visual defect, due to microangiopathy involving the brain, inner ear, and retina. Methods: This was a retrospective review of a case at a tertiary referral center. After diagnosis, the patient was evaluated by a multidisciplinary team and received a cochlear implant in her right ear. Results: The patient achieved 100% open-set sentence recognition in noise conditions and 92% monosyllable and 68% medial consonant recognition in quiet conditions after 6 months of implant use. She reported the use of the telephone 3 months after activation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the impact of atypical retardation patterns (ARP) on detection of progressive retinal nerve fiber layer (RNFL) loss using scanning laser polarimetry with variable corneal compensation (VCC). DESIGN: Observational cohort study. METHODS: The study included 377 eyes of 221 patients with a median follow-up of 4.0 years. Images were obtained annually with the GDx VCC (Carl Zeiss Med, itec Inc, Dublin, California, USA), along with optic disc stereophotographs and standard automated perimetry (SAP) visual fields. Progression was determined by the Guided Progression Analysis software for SAP and by masked assessment of stereophotographs by expert graders. The typical scan score (TSS) was used to quantify the presence of ARPs on GDx VCC images. Random coefficients models were used to evaluate the relationship between ARP and RNFL thickness measurements over time. RESULTS: Thirty-eight eyes (10%) showed progression over time on visual fields, stereophotographs, or both. Changes in TSS scores from baseline were significantly associated with changes in RNFL thickness measurements in both progressing and nonprogressing eyes. Each I unit increase in TSS score was associated with a 0.19-mu m decrease in RNFL thickness measurement (P < .001) over time. CONCLUSIONS: ARPs had a significant effect on detection of progressive RNFL loss with the GDx VCC. Eyes with large amounts of atypical patterns, great fluctuations on these patterns over time, or both may show changes in measurements that can appear falsely as glaucomatous progression or can mask true changes in the RNFL. (Am J Ophthalmol 2009;148:155-163. (C) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the correlation between intraocular pressure (IOP) rise, ocular pulse amplitude (OPA), and choroidal thickness (ChT) during the water drinking test (WDT). Primary open-angle glaucoma (POAG) patients were submitted to the WDT followed by serial IOP measurements using dynamic contour tonometry (DCT), Goldman tonometry (GAT), and ChT measurements using ultrasonographic A and B-scan (USG). A control group not submitted to the test was also evaluated using DCT, GAT, and USG. Intraclass correlation coefficient (ICC) was calculated in the control group in order to assess the reproducibility of measurements. Spearman`s coefficient (rho) was used to assess the correlation between the variables. Thirty eyes were included in the study. There was a significant IOP rise during the WDT using both GAT and DCT (p < 0.001). The OPA and ChT measurements also increased significantly (p < 0.001). Spearman`s correlation between the OPA values and ChT measurements was significant and moderate (rho = 0.40, p = 0.005). The average increase of OPA and ChT measurements occurred 15 min before the IOP rise. There was a significant increase of OPA and ChT measurements followed by an IOP rise during the WDT. Increased choroidal volume due to hemodynamic forces may be enrolled in the mechanism of IOP elevation during this stress test.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To compare the ability of Subjective assessment of optic nerve head (ONH) and retinal nerve fiber layer (RNFL) by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec Inc), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg. Germany), and scanning laser polarimetry (GDx enhanced corneal compensation; Carl Zeiss Meditec Inc, Dublin, CA) in discriminating glaucomatous and normal eyes. Methods: Sixty-one glaucomatous and 57 normal eyes or 118 subjects Were included in the study. Three independent general ophthalmologists and I glaucoma expert evaluated ONH stereo-photographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons or areas under these curves (aROCs) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Results: Best parameter from each technique showed larger aROC (Stratus OCT RNFL 0.92; Stratus OCT ONH vertical integrated area = 0.86; Stratus OCT macular thickness = 0.82; GDx enhanced corneal compensation = 0.91, HRT3 global cup-to-disc ratio = 0.83; HRT3 glaucoma probability score numeric area score 0.83) compared with stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared with stereophoto grading by general ophthalmologists, The combination Of Subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with Subjective assessment of the optic disc by a glaucoma expert (29.5% vs. 19.7%, respectively). Conclusions: Diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by It glaucoma expert, Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare the ability of Fourier-domain (FD) optical coherence tomography (3D OCT-1000; Top, con, Tokyo, Japan) and time domain (TD) OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA) to detect axonal loss in eyes with band atrophy (BA) of the optic nerve. DESIGN: Cross-sectional study. METHODS: Thirty-six eyes from 36 patients with BA and temporal visual field (VF) defect from chiasmal compression and 36 normal eyes were studied. Subjects were submitted to standard automated perimetry and macular and retinal nerve fiber layer (RNFL) measurements were taken using 3D OCT-1000 and Stratus OCT. Receiver operating characteristic (ROC) curves were calculated for each parameter. Spearman correlation coefficients were obtained to evaluate the relationship between RNFL and macular thickness parameters and severity of VF loss. Measurements from the two devices were compared. RESULTS: Regardless of OCT device, all RNFL and macular thickness parameters were significantly lower in eyes with BA compared with normal eyes, but no statistically significant difference was found with regard to the area under the ROC curve. Structure-function relationships were also similar for the two devices. In both groups, RNFL and macular thickness measurements were generally and in some cases significantly smaller with 3D OCT-1000 than with Stratus OCT. CONCLUSIONS: The introduction of FD technology did not lead to better discrimination ability for detecting BA of the optic nerve compared with TD technology when using the software currently provided by the manufacturer. 3D OCT-1000 FD OCT RNFL and macular measurements were generally smaller than TD Stratus OCT measurements. Investigators should be aware of this fact when comparing measurements obtained with these two devices. (Am J Oplathalmol 2009;147: 56-63. (c) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson`s correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The aim of this article is to propose an integrated framework for extracting and describing patterns of disorders from medical images using a combination of linear discriminant analysis and active contour models. Methods: A multivariate statistical methodology was first used to identify the most discriminating hyperplane separating two groups of images (from healthy controls and patients with schizophrenia) contained in the input data. After this, the present work makes explicit the differences found by the multivariate statistical method by subtracting the discriminant models of controls and patients, weighted by the pooled variance between the two groups. A variational level-set technique was used to segment clusters of these differences. We obtain a label of each anatomical change using the Talairach atlas. Results: In this work all the data was analysed simultaneously rather than assuming a priori regions of interest. As a consequence of this, by using active contour models, we were able to obtain regions of interest that were emergent from the data. The results were evaluated using, as gold standard, well-known facts about the neuroanatomical changes related to schizophrenia. Most of the items in the gold standard was covered in our result set. Conclusions: We argue that such investigation provides a suitable framework for characterising the high complexity of magnetic resonance images in schizophrenia as the results obtained indicate a high sensitivity rate with respect to the gold standard. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To evaluate the effect of disease severity and optic disc size on the diagnostic accuracies of optic nerve head (ONH), retinal nerve fiber layer (RNFL), and macular parameters with RTVue (Optovue, Fremont, CA) spectral domain optical coherence tomography (SDOCT) in glaucoma. METHODS. 110 eyes of 62 normal subjects and 193 eyes of 136 glaucoma patients from the Diagnostic Innovations in Glaucoma Study underwent ONH, RNFL, and macular imaging with RTVue. Severity of glaucoma was based on visual field index (VFI) values from standard automated perimetry. Optic disc size was based on disc area measurement using the Heidelberg Retina Tomograph II (Heidelberg Engineering, Dossenheim, Germany). Influence of disease severity and disc size on the diagnostic accuracy of RTVue was evaluated by receiver operating characteristic (ROC) and logistic regression models. RESULTS. Areas under ROC curve (AUC) of all scanning areas increased (P < 0.05) as disease severity increased. For a VFI value of 99%, indicating early damage, AUCs for rim area, average RNLI thickness, and ganglion cell complex-root mean square were 0.693, 0.799, and 0.779, respectively. For a VFI of 70%, indicating severe damage, corresponding AUCs were 0.828, 0.985, and 0.992, respectively. Optic disc size did not influence the AUCs of any of the SDOCT scanning protocols of RTVue (P > 0.05). Sensitivity of the rim area increased and specificity decreased in large optic discs. CONCLUSIONS. Diagnostic accuracies of RTVue scanning protocols for glaucoma were significantly influenced by disease severity. Sensitivity of the rim area increased in large optic discs at the expense of specificity. (Invest Ophthalmol Vis Sci. 2011;92:1290-1296) DOI:10.1167/iovs.10-5516

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Blindness caused by severe vasculitis or uveitis is rare in juvenile systemic lupus erythematosus (JSLE) patients. In a 27-year period, 5367 patients were followed at our Paediatric Rheumatology Division and 263 (4.9%) patients had JSLE (American College of Rheumatology criteria). Of note, two (0.8%) of them had irreversible blindness. One of them presented with cutaneous vasculitis and malar rash, associated with pain and redness in both eyes, impairment of visual acuity due to iridocyclitis and severe retinal vasculitis with haemorrhage. Another patient had peripheral polyneuropathy of the four limbs and received immunosuppressive drugs. Three weeks later, she developed diffuse herpes zoster associated with acute blindness due to bilateral retinal necrotizing vasculitis compatible with varicella zoster virus ocular infection. Despite prompt treatment, both patients suffered rapid irreversible blindness. In conclusion, irreversible blindness due to retinal vasculitis and/or uveitis is a rare and severe lupus manifestation, particularly associated with disease activity and viral infection. Lupus (2011) 20, 95-97.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a 20-year follow-up on a patient with a ring chromosome 14. The ring chromosome was studied by fluorescence in-situ hybridization (FISH), multiplex-ligation probe amplification (MLPA), and genome wide SNP array, and no deletions of chromosome 14 were detected, although the telomeric repeat sequence was absent from the ring chromosome. The patient had skeletal abnormalities, and susceptibility to infections, as well as seizures and retinal pigmentation, which are commonly found in individuals with a ring 14. Our patient corroborates the idea that even when no genes are lost during ring formation, a complete ring chromosome can produce phenotypic alterations, which presumably result from ring instability or gene silencing due to the new chromosomal architecture. (C) 2010 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate retinal nerve fiber layer (RNFL), optic nerve head (ONH), and macular thickness measurements for glaucoma detection using the RTVue spectral domain optical coherence tomograph. Design: Diagnostic, case-control study. Participants: One hundred forty eyes of 106 glaucoma patients and 74 eyes of 40 healthy subjects from the Diagnostic Innovations in Glaucoma Study (DIGS). Methods: All patients underwent ocular imaging with the commercially available RTVue. Optic nerve head, RNFL thickness, and macular thickness scans were obtained during the same visit. Receiver operating characteristic (ROC) curves and sensitivities at fixed specificities (80% and 95%) were calculated for each parameter. Main Outcome Measures: Areas under the ROC curves (AUC) and sensitivities at fixed specificities of 80% and 95%. Results: The AUC for the RNFL parameter with best performance, inferior quadrant thickness, was significantly higher than that of the best-performing ONH parameter, inferior rim area (0.884 vs 0.812, respectively; P = 0.04). There was no difference between ROC curve areas of the best RNFL thickness parameters and the best inner macular thickness measurement, ganglion cell complex root mean square (ROC curve area = 0.870). Conclusions: The RTVue RNFL and inner retinal macular thickness measurements had good ability to detect eyes with glaucomatous visual field loss and performed significantly better than ONH parameters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To evaluate the effect of disease severity on the diagnostic accuracy of the Cirrus Optical Coherence Tomograph (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, CA) for glaucoma detection. METHODS. One hundred thirty-five glaucomatous eyes of 99 patients and 79 normal eyes of 47 control subjects were recruited from the longitudinal Diagnostic Innovations in Glaucoma Study (DIGS). The severity of the disease was graded based on the visual field index (VFI) from standard automated perimetry. Imaging of the retinal nerve fiber layer (RNFL) was obtained using the optic disc cube protocol available on the Cirrus HD-OCT. Pooled receiver operating characteristic (ROC) curves were initially obtained for each parameter of the Cirrus HD-OCT. The effect of disease severity on diagnostic performance was evaluated by fitting an ROC regression model, with VFI used as a covariate, and calculating the area under the ROC curve (AUCs) for different levels of disease severity. RESULTS. The largest pooled AUCs were for average thickness (0.892), inferior quadrant thickness (0.881), and superior quadrant thickness (0.874). Disease severity had a significant influence on the detection of glaucoma. For the average RNFL thickness parameter, AUCs were 0.962, 0.932, 0.886, and 0.822 for VFIs of 70%, 80%, 90%, and 100%, respectively. CONCLUSIONS. Disease severity had a significant effect on the diagnostic performance of the Cirrus HD-OCT and thus should be considered when interpreting results from this device and when considering the potential applications of this instrument for diagnosing glaucoma in the various clinical settings. (Invest Ophthalmol Vis Sci. 2010;51:4104-4109) DOI:10.1167/iovs.094716

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To propose an analytic framework for ocular fundus alterations in late-stage Vogt,Koyanagi-Harada (VKH) disease, to describe the characteristics of overall retinal function as measured with full field electroretinography (ERG), and to correlate the intensity of the fundus changes with full-field ERG alterations and to stratify patients accordingly. DESIGN: Cross-sectional case series. METHODS: Forty-seven eyes of 26 patients with late, stage VKH disease (> 6 months past disease onset) followed-up at the University of Sao Paulo School of Medicine underwent fundus photography within 2 months of a full,field ERG examination, both according to pre-defined protocols. Fundus pictures were evaluated by two observers regarding diffuse fundus depigmentation, nummular lesions, pigment clumps, and subretinal fibrosis, and an overall analysis classified the fundus changes as mild, moderate, or severe. Full field ERG results were analyzed according to fundus-based stratification and also were stratified into 3 groups solely on the basis of decreasing amplitudes (ERG based or cluster stratification). The concordance between fundus-based and full-field ERG-based stratification strategies was estimated. RESULTS: Overall fundus grading showed substantial interobserver concordance (kappa = 0.78). Comparison of full field ERG parameters of the three fundus based stratified groups showed diffusely diminished amplitudes with preservation of implicit times (P < .05). Fundus-based and full-field ERG-based stratification strategies also showed substantial concordance (kappa = 0.68). CONCLUSIONS: The analytic framework for fundus findings proposed in this study seems reproducible and useful, because the severity categories do correlate with retinal function as measured by full-field ERG. This system may allow more precise exchange of information between practitioners as well as researchers with regard to identifying patients with greater retinal compromise rapidly as well as in comparison of outcomes of different treatment regimens. (Am J Ophthalmol 2009;148: 939-945. (C) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To evaluate the relationship between pattern electroretinogram (PERG) amplitude, macular and retinal nerve fiber layer (RNFL) thickness by optical coherence tomography (OCT), and visual field (VF) loss on standard automated perimetry (SAP) in eyes with temporal hemianopia from chiasmal compression. METHODS. Forty-one eyes from 41 patients with permanent temporal VF defects from chiasmal compression and 41 healthy subjects underwent transient full-field and hemifield (temporal or nasal) stimulation PERG, SAP and time domain-OCT macular and RNFL thickness measurements. Comparisons were made using Student`s t-test. Deviation from normal VF sensitivity for the central 18 of VF was expressed in 1/Lambert units. Correlations between measurements were verified by linear regression analysis. RESULTS. PERG and OCT measurements were significantly lower in eyes with temporal hemianopia than in normal eyes. A significant correlation was found between VF sensitivity loss and fullfield or nasal, but not temporal, hemifield PERG amplitude. Likewise a significant correlation was found between VF sensitivity loss and most OCT parameters. No significant correlation was observed between OCT and PERG parameters, except for nasal hemifield amplitude. A significant correlation was observed between several macular and RNFL thickness parameters. CONCLUSIONS. In patients with chiasmal compression, PERG amplitude and OCT thickness measurements were significant related to VF loss, but not to each other. OCT and PERG quantify neuronal loss differently, but both technologies are useful in understanding structure-function relationship in patients with chiasmal compression. (ClinicalTrials.gov number, NCT00553761.) (Invest Ophthalmol Vis Sci. 2009; 50: 3535-3541) DOI:10.1167/iovs.08-3093