76 resultados para fluid retention
Resumo:
Histopathological alterations in human aneurysms and dissections of the thoracic ascending aorta include areas of mucoid degeneration within the medial layer, colocalized with areas of cell disappearance and disruption of extracellular matrix elastic and collagen fibers. We studied the presence of matrix metalloproteinases in relation to their capacity to diffuse through the tissue or to be retained in areas of mucoid degeneration in aneurysms and dissections of the ascending aorta. Ascending aortas from 9 controls, 33 patients with aneurysms, and 14 with acute dissections, all collected at surgery, were analyzed. The morphological aspect was similar whatever the etiology or phenotypic expression of the pathological aortas, involving areas of extracellular matrix breakdown and cell rarefaction associated with mucoid degeneration. Release of proMMP-2, constitutively expressed by smooth muscle cells, was not different between controls and aneurysmal aortas, whereas the aneurysmal aortas released more of the active form. Release of pro and active MMP-9 was also similar between controls and aneurysmal aortas. Immunohistochemical staining of MMP-2 and MMP-9 was weak in both control and pathological aortas. In contrast, released MMP-7 (matrilysin) and MMP-3 (stromelysin-1) could not be detected in conditioned media but were present in tissue extracts with no detectable quantitative difference between controls and pathological aortas. Immunohistochemical staining of MMP-7 and MMP-3 revealed their retention in areas of mucoid degeneration, and semiquantitative evaluation of immunostaining showed more MMP-7 in pathological aortas than in controls. In conclusion, areas of mucoid degeneration, the hallmark of aneurysms, and dissections of thoracic ascending aortas, whatever their etiology, are not inert and can retain specific proteases. (c) 2009 Elsevier Inc. All rights reserved.
Resumo:
This study investigated the effect of porcine follicular fluid (PFF) and dibutyryl cyclic adenosine monophosphate (dbcAMP) during in vitro maturation (IVM) of porcine oocytes on meiotic maturation, fertilization and embryo development, and compared the effect of supplementing the embryo culture media with PFF or foetal bovine serum (FBS) on embryo development. Oocytes from pre-pubertal gilts were IVM for 44 h, and parthenogenetically activated or in vitro-fertilized. Embryos were cultured in porcine zygote medium (PZM3) for 7 days. Cleavage and blastocyst rates were evaluated at 48 h and 7 days of culture. The supplementation of the IVM medium with 25% PFF and 1 mm dbcAMP for the first 22 h resulted in more (p < 0.05) embryos developing to the blastocyst stage as compared with the inclusion of dbcAMP alone. The dbcAMP + PFF combination increased (p < 0.05) the average number of nuclei per blastocyst as compared with either of these components alone or in its absence. A synergistic effect of dbcAMP + PFF during IVM was also reflected in the capacity of oocytes to regulate sperm penetration and prevent polyspermy, as twice as many oocytes from the control group were penetrated by more than one sperm as compared with those matured in the presence of both dbcAMP and PFF. The supplementation of PZM3 with 10% FBS from days 5 to 7 of culture significantly improved the total cell quantity in embryos derived either from control or dbcAMP + PFF matured oocytes. There was no effect on the total cell quantity when FBS was replaced by the same concentration of PFF. These studies showed that dbcAMP, PFF and FBS can improve both the quantity (57.3% vs 41.5%) and quality (74.8 vs 33.3 nuclei) of porcine blastocysts derived from oocytes recovered of pre-pubertal gilts.
Resumo:
This study was conducted to determine the effect of pre-exposure of oocytes to Ricinus communis (RCA-1) lectin and osteopontin (OPN) in uterine tube fluid (UTF) on in vitro sperm-egg binding and fertilization. In vitro-matured bovine oocytes were incubated (39 degrees C, 5% CO(2) in air) for 2 h in the following treatments: (i) 500 mu l of fertilization medium (FM); (ii) 250 mu l of FM with 0.25 ml of non-luteal ampullary uterine tube fluid (NLAUTF); (iii) 250 mu l of FM with 250 mu l of NLAUTF and 4 mu l of RCA-1 lectin; (iv) 250 mu l of FM with 250 mu l of NLAUTF, a rabbit polyclonal antibody (1:200) against purified bovine milk OPN, and RCA-1 lectin; (v) 500 mu l of FM and RCA-1 lectin. Following incubation, oocytes were washed, placed in FM with 2 mu g heparin, and incubated with 1 x 10(5) frozen-thawed spermatozoa per 10 oocytes. Oocytes used to assess sperm binding were stained with Hoescht 33342, and the number of sperm bound per zona pellucida counted. The remaining oocytes were fixed in acid alcohol, stained with 1% acetate-orcein and observed to determine the presence of pronuclei. More sperm bound to the zona pellucida (mean +/- SEM) when oocytes were incubated in treatment 3 (59.0 +/- 5.5) than in treatments 2 (46.4 +/- 5.6), 4 (18.1 +/- 5.4), 5 (33.4 +/- 5.6) or 1 (32.5 +/- 5.6). More oocytes were fertilized when incubated in treatment 3 (91% +/- 3.0) than in 2 (84% +/- 3.0), 4 (40% +/- 3.0), 5 (77% +/- 3.0) or 1 (76% +/- 3.0). As in previous studies, this study suggests that RCA-1 lectin enhances binding of UTF-derived OPN to bovine oocytes, resulting in increased sperm-egg binding and fertilization in vitro and a possible role in fertilization.
Resumo:
Studies have demonstrated that oviductal fluid (ODF) proteins associate with eggs of numerous species including the bovine. In this study, the association of three ODF proteins, the bovine oestrus-associated protein, osteopontin (OPN), lipocalin-type prostaglandin D synthase (L-PGDS), with the bovine zona pellucida (ZP) was demonstrated by immunohistochemistry and western blot. The biological function of ODF derived egg-associated OPN and L-PGDS in sperm binding, fertilization and embryonic development was also explored. In vitro matured bovine oocytes were pre-incubated with ODF collected by cannula from cows in oestrus, or ODF with antibodies to OPN, L-PGDS and bovine serum albumin (BSA). Following incubation, oocytes were inseminated with 1 x 10(5) frozen-thawed spermatozoa, and they were evaluated for sperm binding, fertilization and embryonic development in vitro. Pre-treatment of ODF with antibodies to all of proteins reduced sperm binding to the ZP and fertilization in vitro. Cleavage rates were not significantly different among incubations, but rates of embryo development were significantly decreased. We conclude that antibodies to OPN, L-PGDS and BSA react with oocytes incubated with ODF and inhibit sperm binding, fertilization and embryonic development in vitro, suggesting a potential role of these proteins in these events.
Resumo:
Objectives: The aim of this study was to determine the precision of the measurements of 2 craniometric anatomic points-glabella and anterior nasal spine-in order to verify their possibility as potential locations for placing implants aimed at nasal prostheses retention. Methods: Twenty-six dry human skulls were scanned in a high-resolution spiral tomography with 1-mm axial slice thickness and 1-mm interval reconstruction using a bone tissue filter. Images obtained were stored and transferred to an independent workstation containing e-film imaging software. The measurements (in the glabella and anterior nasal fossa) were made independently by 2 observers twice for each measurement. Data were submitted to statistical analysis (parametric t test). Results: The results demonstrated no statistically significant difference between interobserver and intraobserver measurements (P > .05). The standard error was found to be between 0.49 mm and 0.84 mrn for measurements in bone protocol, indicating a high /eve/ of precision. Conclusions: The measurements obtained in anterior nasal spine and glabella were considered precise and reproducible. Mean values of such measurements pointed to the possibility of implant placement in these regions, particularly in the anterior nasal spine.
Resumo:
Retention systems for implant-retained auricular prostheses using either bar-clip attachments with 2 or 3 clips or retention with 2 or 3 magnets were wear tested (insertion and removal cycles) to simulate clinical periods of use. Measurements were taken at intervals of 540 cycles, which represents a period of use of approximately 6 months, for up to 3,240 cycles. Assessments of retentive force were carried out before, during, and after the wear test. Statistical analysis indicated that the bar-clip systems provided higher retention than the magnetic systems. The bar-clip attachment with 2 clips showed a significant loss of retentive force after wear testing (P < .05), suggesting lower durability and shorter clinical life. The retention provided by the bar-clip attachment with 3 clips remained stronger than that provided by all other systems tested. At the end of the wear test, the magnetic systems showed very little loss of retention but were still less retentive than the bar-clip systems, suggesting higher durability under clinical simulation despite the lower retention initially provided.
Resumo:
The purpose of this in vitro study was to compare the bond strength between fiber post and laser-treated root canals. Forty single-rooted bovine teeth were endodontically treated and randomly divided into four groups of equal size according to the root canal treatment: group 1 conventional treatment (without laser irradiation); group 2 Nd:YAG laser (1.5 W, 10 Hz, 100 mJ); group 3 Er,Cr:YSGG laser (0.75 W, 20 Hz); and group 4 Nd:YAG + Er,Cr:YSGG lasers. The fiber posts were cemented with an adhesive system + resin cement, in accordance with the manufacturer`s instructions. A mini acrylic pipe was fixed on the coronal section of the post using a light-polymerized resin. Specimens were mounted on an acrylic pipe with a self-polymerized resin. Retention forces were determined using a universal testing machine (0.5 mm/min). Data were analyzed using one-way ANOVA and Tukey tests (p < 0.05). The post retention force in group 2 was found to be lower than that in the other experimental groups. Fractures were observed at the interface between the dentin and the resin in all groups. High-intensity lasers can be used in conventional endodontic treatment; however, root canal surface irradiation using the Nd:YAG laser was shown to negatively affect the post retention force.
Resumo:
Purpose This 24-month randomized paired tooth clinical study evaluated the performance of All Bond 3 used in the simplified (2-step) and full (3-step) versions Methods 33 patients, with at least two similar sized non-carious cervical lesions participated in this study A total of 66 restorations were placed, half using the 2-step All Bond 3 (AB3-2) and the other half using 3-step All Bond 3 (AB3-3) The restorations were placed incrementally using the composite resin Aelite The restorations were evaluated at baseline and after 6, 12 and 24 months following the modified USPHS criteria Statistical differences between the adhesive were tested using with McNemar`s test and clinical performance over time for each material with the Fisher`s exact test (alpha= 0 05) Results After 24 months, six AB3-2 and four AB3-3 were rated as bravo for marginal discoloration but did not differ from each other significantly (P> 0 05) The retention rates at 24 months of AB3-2 and AB3-3 were 90 9% and 97 0%, respectively (P> 0 05) (Am J Dent 2010,23 231-236)
Resumo:
Purpose: This prospective clinical trial compared the retention rate and caries-preventive efficacy of two types of sealant modalities over a 3-year period. Materials and Methods: Using a split-mouth randomised design, 1280 sealants were randomly applied on sound permanent second molars of 320 young patients aged between 12 and 16 years. Half of the teeth (n = 640) were sealed with a resin-modified glass ionomer cement (RMGIC) (Vitremer (TM), 3M ESPE) and the other half (n = 640) with a conventional light-cure, resin-based fissure sealant (LCRB) (Fluoroshield (R), Dentsply Caulk). Teeth were evaluated at baseline, 6-, 12-, 18-, 24-, 30- and 36-month intervals with regard to retention and new caries development. Results: On the sealed occlusal surfaces after 3 years, 5.10% of RMGIC and 91.08% of LCRB sealants were totally intact and 6.37% of RMGIC and 7.65% of LCRB sealants were partially intact. New caries lesions were found in 20.06% of RMGIC sealed occlusal surfaces, compared to 8.91% for LCRB sealants. Conclusions: The findings of the present clinical study suggest that RMGIC should be used only as a transitional sealant that can be applied to newly erupting teeth throughout the eruptive process, whereas LCRB sealants are used to successfully prevent occlusal caries lesions once an effective rubber dam can be achieved. It can be concluded that there are differences between the RMGIC and LCRB sealants over a 3-year period in terms of the retention rate and caries-preventive efficacy. RMGIC can serve as a simple and economic sealing solution, however provisional. Due to its poor retention rate, periodic recalls are necessary, even after 6 months, to eventually replace the lost sealant.
Resumo:
Objectives: This study examined the retention of solvents within experimental HEMA/solvent primers after two conditions for solvent evaporation: from a free surface or from dentine surface. Methods: Experimental primers were prepared by mixing 35% HEMA with 65% water, methanol, ethanol or acetone (v/v). Aliquots of each primer (50 mu l) were placed on glass wells or they were applied to the surface of acid-etched dentine cubes (2 mm x 2 mm x 2 mm) (n = 5). For both conditions (i.e. from free surface or dentine cubes), change in primers mass due to solvent evaporation was gravimetrically measured for 10 min at 51% RH and 21 degrees C. The rate of solvent evaporation was calculated as a function of loss of primers mass (%) over time. Data were analysed by two-way ANOVA and Student-Newman-Keuls (p < 0.05). Results: There were significant differences between solvent retention(%) and evaporation rate (%/min) depending on the solvent present in the primer and the condition for evaporation (from free surface or dentine cubes) (p < 0.05). For both conditions, the greatest amount of retained solvent was observed for HEMA/water primer. The rate of solvent evaporation for HEMA/acetone primer was almost 2- to 10-times higher than for HEMA/water primer depending whether evaporation occurred, respectively, from a free surface or dentine cubes. The rate of solvent evaporation varied with time, being in general highest at the earliest periods. Conclusions: The rate of solvent evaporation and its retention into HEMA/solvent primers was influenced by the type of the solvent and condition allowed for their evaporation. (C) 2009 Elsevier Ltd. All rights reserved.
Gingival crevicular fluid levels of MMP-8, MMP-9, TIMP-2, and MPO decrease after periodontal therapy
Resumo:
P>Background This study aimed at comparing the levels of matrix metalloproteinase (MMP)-8, tissue Inhibitor of MMPs (TIMP)-1 and TIMP-2, Myeloperoxidase (MPO), and MMP-9 in the gingival crevicular fluid (GCF) of chronic periodontitis (CP) patients and controls at baseline and 3 months after non-surgical therapy. Materials and Methods GCF was collected from one site of 15 control subjects and 27 CP patients. MMP-8, MMP-9, TIMP-1, and TIMP-2 were determined by Enzyme-linked immunoabsorbent assay; different forms of MMP-9, by gelatin zymography; and MPO, colorimetrically. Results At baseline, higher levels of MMP-8, TIMP-2, MPO, and the 87 kDa-MMP-9 were found in patients compared with controls (p < 0.001), and these molecules decreased after therapy (p < 0.03). There were no differences between the groups with respect to the higher molecular forms of MMP-9 (180, 130, 92 kDa) or total MMP-9 at baseline. No differences were observed in TIMP-1 levels. In controls, decreased levels of TIMP-2 and the higher molecular forms of MMP-9 (180, 130, 92 kDa) were found 3 months after therapy compared with baseline (p < 0.01). Conclusions Higher levels of MMP-8, TIMP-2, MPO, and 87 kDa MMP-9 were found in the GCF of patients compared with controls, and these markers decreased 3 months after periodontal therapy.
Resumo:
P>This study assessed the effect of simulated mastication on the retention of two stud attachment systems for 2-implants overdentures. Sixteen specimens, each simulating an edentulous ridge with implants and an overdenture were divided into two groups, according to the attachment system: Group I (Nobel Biocare ball-socket attachments) and Group II (Locator attachments). Retention forces were measured before and after 400 000 simulated masticatory loads in a customised device. Data were compared by two-way anova followed by Bonferroni test (alpha = 0 center dot 05). Group I presented significantly lower retention forces (Newtons) than Group II at baseline (10 center dot 6 +/- 3 center dot 6 and 66 center dot 4 +/- 16 center dot 0, respectively). However, differences were not significant after 400 000 loads (7 center dot 9 +/- 4 center dot 3 and 21 center dot 6 +/- 17 center dot 0). The number of cycles did not influence the measurements in Group I, whereas a non-linear descending curve was found for Group II. It was concluded that simulated mastication resulted in minor changes for the ball attachment tested. Nevertheless, it reduced the retention of Locator attachments to 40% of the baseline values, what suggests that mastication is a major factor associated with maintenance needs for this system.
Resumo:
P>The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator (R)) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.
Resumo:
Objective The purpose of this study was to evaluate the retention force of an O-ring attachment system in different inclinations to the ideal path of insertion, using devices to compensate angulations. Material and methods Two implants were inserted into an aluminum base, and ball attachments were screwed to implants. Cylinders with O-rings were placed on ball attachments and connected to the test device using positioners to compensate implant angulations (0 degrees, 7 degrees, and 14 degrees). Plexiglass bases were used to simulate implant angulations. The base and the test device were positioned in a testing apparatus, which simulated insertion/removal of an overdenture. A total of 2900 cycles, simulating 2 years of overdenture use, were performed and 36 O-rings were tested. The force required for each cycle was recorded with computer software. Longitudinal sections of ball attachment-positioner-cylinder with O-rings of each angulation were obtained to analyze the relationship among them, and O-ring sections tested in each angulation were compared with an unused counterpart. A mixed linear model was used to analyze the data, and the comparison was performed by orthogonal contrasts (alpha=0.05). Results At 0 degrees, the retention force decreased significantly over time, and the retention force was significantly different in all comparisons, except from 12 to 18 months. When the implants were positioned at 7 degrees, the retention force was statistically different at 0 and 24 months. At 14 degrees, significant differences were found from 6 and 12 to 24 months. Conclusions Within the limitations of this study, it was concluded that O-rings for implant/attachments perpendicular to the occlusal plane were adequately retentive over the first year and that the retentive capacity of O-ring was affected by implant inclinations despite the proposed positioners. To cite this article:Rodrigues RCS, Faria ACL, Macedo AP, Sartori IAM, de Mattos MGC, Ribeiro RF. An in vitro study of non-axial forces upon the retention of an O-ring attachment.Clin. Oral Impl. Res. 20, 2009; 1314-1319.doi: 10.1111/j.1600-0501.2009.01742.x.
Resumo:
Background: Aggressive periodontitis is a specific form of periodontal disease that is characterized by rapid attachment loss and bone destruction. Cytokine profiles are of considerable value when studying disease course during treatment. The aim of this trial was to investigate cytokine levels in the gingival crevicular fluid (GCF) of patients with aggressive periodontitis, after treatment with photodynamic therapy (PDT) or scaling and root planing (SRP), in a split-mouth design on -7, 0, +1, +7, +30, and +90 days. Methods: Ten patients were randomly treated with PDT using a laser source associated with a photosensitizer or SRP with hand instruments. GCF samples were collected, and the concentrations of tumor necrosis factor-alpha (TNF-alpha) and receptor activator of nuclear factor-kappa B ligand (RANKL) were determined by enzyme-linked immunosorbent assays. The data were analyzed using generalized estimating equations to test the associations among treatments, evaluated parameters, and experimental times (alpha = 0.05). Results: Non-surgical periodontal treatment with PDT or SRP led to statistically significant reductions in TNF-alpha level 30 days following treatment. There were similar levels of TNF-alpha and RANKL at the different time points in both groups, with no statistically significant differences. Conclusion: SRP and PDT had similar effects on crevicular TNF-alpha and RANKL levels in patients with aggressive periodontitis. J Periodontol 2009;80:98-105.