66 resultados para Wu jing


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present the first measurements of the rho(770)(0),K(*)(892),Delta(1232)(++),Sigma(1385), and Lambda(1520) resonances in d+Au collisions at s(NN)=200 GeV, reconstructed via their hadronic decay channels using the STAR detector (the solenoidal tracker at the BNL Relativistic Heavy Ion Collider). The masses and widths of these resonances are studied as a function of transverse momentum p(T). We observe that the resonance spectra follow a generalized scaling law with the transverse mass m(T). The < p(T)> of resonances in minimum bias collisions are compared with the < p(T)> of pi,K, and p. The rho(0)/pi(-),K(*)/K(-),Delta(++)/p,Sigma(1385)/Lambda, and Lambda(1520)/Lambda ratios in d+Au collisions are compared with the measurements in minimum bias p+p interactions, where we observe that both measurements are comparable. The nuclear modification factors (R(dAu)) of the rho(0),K(*), and Sigma(*) scale with the number of binary collisions (N(bin)) for p(T)> 1.2 GeV/c.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The STAR Collaboration at the BNL Relativistic Heavy Ion Collider has measured two-pion correlation functions from p + p collisions at root s = 200 GeV. Spatial scales are extracted via a femtoscopic analysis of the correlations, though this analysis is complicated by the presence of strong nonfemtoscopic effects. Our results are put into the context of the world data set of femtoscopy in hadron-hadron collisions. We present the first direct comparison of femtoscopy in p + p and heavy ion collisions, under identical analysis and detector conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Data collected at the Pierre Auger Observatory are used to establish an upper limit on the diffuse flux of tau neutrinos in the cosmic radiation. Earth-skimming nu(tau) may interact in the Earth's crust and produce a tau lepton by means of charged-current interactions. The tau lepton may emerge from the Earth and decay in the atmosphere to produce a nearly horizontal shower with a typical signature, a persistent electromagnetic component even at very large atmospheric depths. The search procedure to select events induced by tau decays against the background of normal showers induced by cosmic rays is described. The method used to compute the exposure for a detector continuously growing with time is detailed. Systematic uncertainties in the exposure from the detector, the analysis, and the involved physics are discussed. No tau neutrino candidates have been found. For neutrinos in the energy range 2x10(17) eV < E(nu)< 2x10(19) eV, assuming a diffuse spectrum of the form E(nu)(-2), data collected between 1 January 2004 and 30 April 2008 yield a 90% confidence-level upper limit of E(nu)(2)dN(nu tau)/dE(nu)< 9x10(-8) GeV cm(-2) s(-1) sr(-1).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A series of organochalcogenanes was synthesized and evaluated as protein tyrosine phosphatases (PTPs) inhibitors. The results indicate that organochalcogenanes inactivate the PTPs in a time- and concentration-dependent fashion, most likely through covalent modification of the active site sulfur-moiety by the chalcogen atom. Consequently, organochalcogenanes represent a new class of mechanism-based probes to modulate the PTP-mediated cellular processes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to estimate the first-order intrinsic kinetic constant (k(1)) and the liquid-phase mass transfer coefficient (k(c)) in a bench-scale anaerobic sequencing batch biofilm reactor (ASBBR) fed with glucose. A dynamic heterogeneous mathematical model, considering two phases (liquid and solid), was developed through mass balances in the liquid and solid phases. The model was adjusted to experimental data obtained from the ASBBR applied for the treatment of glucose-based synthetic wastewater with approximately 500 mg L-1 of glucose, operating in 8 h batch cycles, at 30 degrees C and 300 rpm. The values of the parameters obtained were 0.8911 min(-1) for k(1) and 0.7644 cm min(-1) for kc. The model was validated utilizing the estimated parameters with data obtained from the ASBBR operating in 3 h batch cycles, with a good representation of the experimental behavior. The solid-phase mass transfer flux was found to be the limiting step of the overall glucose conversion rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A modeling study was completed to develop a methodology that combines the sequencing and finite difference methods for the simulation of a heterogeneous model of a tubular reactor applied in the treatment of wastewater. The system included a liquid phase (convection diffusion transport) and a solid phase (diffusion reaction) that was obtained by completing a mass balance in the reactor and in the particle, respectively. The model was solved using a pilot-scale horizontal-flow anaerobic immobilized biomass (HAIB) reactor to treat domestic sewage, with the concentration results compared with the experimental data. A comparison of the behavior of the liquid phase concentration profile and the experimental results indicated that both the numerical methods offer a good description of the behavior of the concentration along the reactor. The advantage of the sequencing method over the finite difference method is that it is easier to apply and requires less computational time to model the dynamic simulation of outlet response of HAIB.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The thermoelastic properties of ferropericlase Mg(1-x)Fe(x)O (x = 0.1875) throughout the iron high-to-low spin cross-over have been investigated by first principles at Earth`s lower mantle conditions. This cross-over has important consequences for elasticity such as an anomalous bulk modulus (K(S)) reduction. At room temperature the anomaly is somewhat sharp in pressure but broadens with increasing temperature. Along a typical geotherm it occurs across most of the lower mantle with a more significant K(S) reduction at approximate to 1,400-1,600 km depth. This anomaly might also cause a reduction in the effective activation energy for diffusion creep and lead to a viscosity minimum in the mid-lower mantle, in apparent agreement with results from inversion of data related with mantle convection and postglacial rebound.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We demonstrate anisotropic etching of single-layer graphene by thermally activated nickel nanoparticles. Using this technique, we obtain sub-10-nm nanoribbons and other graphene nanostructures with edges aligned along a single crystallographic direction. We observe a new catalytic channeling behavior, whereby etched cuts do not intersect, resulting in continuously connected geometries. Raman spectroscopy and electronic measurements show that the quality of the graphene is resilient under the etching conditions, indicating that this method may serve as a powerful technique to produce graphene nanocircuits with well-defined crystallographic edges.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The recognition of temporally stable locations with respect to soil water content is of importance for soil water management decisions, especially in sloping land of watersheds. Neutron probe soil water content (0 to 0.8 m), evaluated at 20 dates during a year in the Loess Plateau of China, in a 20 ha watershed dominated by Ust-Sandiic Entisols and Aeolian sandy soils, were used to define their temporal stability through two indices: the standard deviation of relative difference (SDRD) and the mean absolute bias error (MABE). Specific concerns were (a) the relationship of temporal stability with soil depth, (b) the effects of soil texture and land use on temporal stability, and (c) the spatial pattern of the temporal stability. Results showed that temporal stability of soil water content at 0.2 m was significantly weaker than those at the soil depths of 0.6 and 0.8 m. Soil texture can significantly (P<0.05) affect the stability of soil water content except for the existence of an insignificant difference between sandy loam and silt loam textures, while temporal stability of areas covered by bunge needlegrass land was not significantly different from those covered by korshinsk peashrub. Geostatistical analysis showed that the temporal stability was spatially variable in an organized way as inferred by the degree of spatial dependence index. With increasing soil depth, the range of both temporal stability indices showed an increasing trend, being 65.8-120.5 m for SDRD and 148.8-214.1 m for MABE, respectively. This study provides a valuable support for soil water content measurements for soil water management and hydrological applications on sloping land areas. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The skin is a large and accessible area of the body, offering the possibility to be used as an alternative route for drug delivery. In the last few years strong progress has been made on the developing of nanoparticulate systems for specific applications. The interaction of such small particles with human skin and their possible penetration attracted some interest from toxicological as well as from drug delivery perspectives. As size is assumed to play a key role, the aim of the present work was to investigate the penetration profile of very small model particles (similar to 4 nm) into excised human skin under conditions chosen to mimic the in vivo situation. Possible application procedures such as massaging the formulation (5 to 10 minutes) were analyzed by non-invasive multiphoton- and confocal laser scanning microscopy (MPM, CLSM). Furthermore, the application on damaged skin was taken into account by deliberately removing parts of the stratum corneum. Although it was clearly observed that the mechanical actions affected the distribution pattern of the QDs on the skin surface, there was no evidence of penetration into the skin in all cases tested. QDs could be found in deeper layers only after massaging of damaged skin for 10 min. Taking these data into account, obtained on the gold standard human skin, the potential applications of nanoparticulate systems to act as carrier delivering drugs into intact skin might be limited and are only of interest for partly damaged skin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Studies have shown that human immunodeficiency virus (HIV) residual risk is higher in Brazilian than in US and European blood donors, probably due to failure to defer at-risk individuals in Brazil. This study assessed the impact of an educational brochure in enhancing blood donors` knowledge about screening test window phase and reducing at-risk individuals from donating. STUDY DESIGN AND METHODS: This trial compared an educational intervention with a blood center`s usual practice. The brochure was distributed in alternating months to all donors. After donating, sampled participants completed two questions about their HIV window period knowledge. The impact on HIV risk deferral, leaving without donation, confidential unit exclusion (CUE) use, and test positivity was also analyzed. RESULTS: From August to November 2007 we evaluated 33,940 donations in the main collection center of Fundacao Pro-Sangue/Hemocentro de Sao Paulo in Sao Paulo, Brazil. A significant (p < 0.001) pamphlet effect was found on correct responses to both questions assessing HIV window phase knowledge (68.1% vs. 52.9%) and transfusion risk (91.1% vs. 87.2%). After adjusting for sex and age, the pamphlet effect was strongest for people with more than 8 years of education. There was no significant pamphlet effect on HIV risk deferral rate, leaving without donation, use of CUE, or infectious disease rates. CONCLUSION: While the educational pamphlet increased window period knowledge, contrary to expectations this information alone was not enough to make donors self-defer or acknowledge their behavioral risk.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of a clinical classification of pulmonary hypertension (PH) is to group together different manifestations of disease sharing similarities in pathophysiologic mechanisms, clinical presentation, and therapeutic approaches. In 2003, during the 3rd World Symposium on Pulmonary Hypertension, the clinical classification of PH initially adopted in 1998 during the 2nd World Symposium was slightly modified. During the 4th World Symposium held in 2008, it was decided to maintain the general architecture and philosophy of the previous clinical classifications. The modifications adopted during this meeting principally concern Group 1, pulmonary arterial hypertension (PAH). This subgroup includes patients with PAH with a family history or patients with idiopathic PAH with germline mutations (e. g., bone morphogenetic protein receptor-2, activin receptor-like kinase type 1, and endoglin). In the new classification, schistosomiasis and chronic hemolytic anemia appear as separate entities in the subgroup of PAH associated with identified diseases. Finally, it was decided to place pulmonary venoocclusive disease and pulmonary capillary hemangiomatosis in a separate group, distinct from but very close to Group 1 (now called Group 1`). Thus, Group 1 of PAH is now more homogeneous. (J Am Coll Cardiol 2009;54:S43-54) (C) 2009 by the American College of Cardiology Foundation

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Compared with other specialties, the field of physical and rehabilitation medicine has not received the deserved recognition from clinicians and researchers in the scientific community. One of the reasons is the lack of sound evidence to support the traditional physical and rehabilitation medicine treatments. The best way to change this disadvantage is through a well conducted clinical research, such as standard placebo- or sham-controlled randomized clinical trials. Therefore, having placebo groups in clinical trials is essential to improve the level of evidence-based practice in physical and rehabilitation medicine that ultimately translates to better clinical care. To address the challenges for the use of placebo in physical and rehabilitation medicine and randomized clinical trials and to create useful recommendations, we convened a working group during the inaugural International Symposium in Placebo (February 2009, in Sao Paulo, Brazil) in which the following topics were discussed: (1) current status of randomized clinical trials in physical and rehabilitation medicine, (2) challenges for the use of placebo in physical and rehabilitation medicine, (3) bioethics, (4) use of placebo in acupuncture trials and for the treatment of low-back pain, (5) mechanisms of placebo, and (6) insights from other specialties. The current article represents the consensus report from the working group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. Refractory, disabling pain associated with knee osteoarthritis (OA) is usually treated with total knee replacement. However, pain in these patients might be associated with central nervous sensitization rather than peripheral inflammation and injury. We evaluated the presence of hyperalgesia in patients scheduled for a total knee replacement due to knee osteoarthritis with refractory pain, and we assessed the impact of pressure pain threshold measurements (PPT) on pain, disability, and quality of life of these patients. Methods. Sixty-two female patients were compared with 22 age-matched healthy controls without reported pain for the last year. PPT was measured at the lower extremities subcutaneous dermatomes, over the vastus medialis, adductor longus, rectus femoris, vastus lateralis, tibialis anterior, peroneus longus, iliacus, quadratus lumborum and popliteus muscles and at the supraspinous ligaments from L1-L5, over the L5-S1 and S1-S2 sacral areas and at the pes anserinus bursae and patellar tendon. Results. Patients with knee OA had significantly lower PPT over all evaluated structures versus healthy control subjects (P < 0.001). Lower PPT values were correlated with higher pain intensity, higher disability scores, and with poorer quality of life, except for the role-emotional and general health status. Combined PPT values over the patellar tendon, at the S2 subcutaneous dermatome and at the adductor longus muscle were the best predictors for visual analog scale and Western Ontario and McMaster Universities Osteoarthritis Index pain scores. Conclusion. Patients with pain due to osteoarthritis who were scheduled for total knee replacement showed hyperalgesia of nervous system origin that negatively impacted pain, knee functional capacity, and most aspects of quality of life.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The cerebrospinal fluid (CSF) biomarkers amyloid beta (A beta)-42, total-tau (T-tau), and phosphorylated-tau (P-tau) demonstrate good diagnostic accuracy for Alzheimer`s disease (AD). However, there are large variations in biomarker measurements between studies, and between and within laboratories. The Alzheimer`s Association has initiated a global quality control program to estimate and monitor variability of measurements, quantify batch-to-batch assay variations, and identify sources of variability. In this article, we present the results from the first two rounds of the program. Methods: The program is open for laboratories using commercially available kits for A beta, T-tau, or P-tau. CSF samples (aliquots of pooled CSF) are sent for analysis several times a year from the Clinical Neurochemistry Laboratory at the Molndal campus of the University of Gothenburg, Sweden. Each round consists of three quality control samples. Results: Forty laboratories participated. Twenty-six used INNOTEST enzyme-linked immunosorbent assay kits, 14 used Luminex xMAP with the INNO-BIA AlzBio3 kit (both measure A beta-(1-42), P-tau(181P), and T-tau), and 5 used Mesa Scale Discovery with the A beta triplex (A beta N-42, A beta N-40, and A beta N-38) or T-tau kits. The total coefficients of variation between the laboratories were 13% to 36%. Five laboratories analyzed the samples six times on different occasions. Within-laboratory precisions differed considerably between biomarkers within individual laboratories. Conclusions: Measurements of CSF AD biomarkers show large between-laboratory variability, likely caused by factors related to analytical procedures and the analytical kits. Standardization of laboratory procedures and efforts by kit vendors to increase kit performance might lower variability, and will likely increase the usefulness of CSF AD biomarkers. (C) 2011 The Alzheimer`s Association. All rights reserved.