72 resultados para Ultrasonography
Resumo:
Purpose The purpose of the study was to examine the most adequate cut-off point for median nerve cross-sectional area and additional ultrasound features supporting the diagnosis of carpal tunnel syndrome (CTS). Material and methods Forty wrists from 31 CTS patients and 63 wrists from 37 asymptomatic volunteers were evaluated by ultrasound. All patients were women. The mean age was 49.1 years (range: 29-78) in the symptomatic and 45.1 years (range 24-82) in the asymptomatic group. Median nerve cross-sectional area was obtained using direct (DT) and indirect (IT) techniques. Median nerve echogenicity, mobility, flexor retinaculum measurement and the anteroposterior (AP) carpal tunnel distance were assessed. This study was IRB-approved and all patients gave informed consent prior to examination. Results In CTS the median nerve cross-sectional area was increased compared with the control group. Median nerve cross-sectional area of 10 mm(2) (DT) and 9 mm(2) (IT) had high sensitivity (85% and 88.5%, respectively), specificity (92.1% and 82.5%) and accuracy (89.3% and 82.5%) in the diagnosis of CTS. CTS patients had an increased carpal tunnel AP diameter, flexor retinaculum thickening, reduced median nerve mobility and decreased median nerve echogenicity. Conclusion Ultrasound assists in the diagnosis of CTS using the median nerve diameter cut-off point of 10 mm(2) (DT) and 9 mm(2) (IT) and several additional findings.
Resumo:
Objective To describe the natural history of fetuses presenting with pleural effusion. Methods Between January 2005 and December 2009 all fetuses diagnosed with pleural effusion were followed up. Fetuses were divided into three groups: I, isolated pleural effusion; II, associated structural anomalies but normal karyotype; and III, chromosomal anomalies. Univariate and multivariate analyses were performed to determine the association between prenatal ultrasound findings and perinatal death. Results Fifty-six fetuses were included in the study. Associated structural or chromosomal anomalies occurred in 75.0% (42/56) of cases. Bilateral pleural effusion and fetal hydrops were associated with each other (p < 0.01) and with perinatal death (p < 0.05). Multivariate analysis indicated that only the presence of associated abnormalities was a statistical determinant of perinatal death (OR, 3.56; 95% CI, 1.48-5.64; p < 0.01). Conclusion Fetal pleural effusion is often associated with other abnormalities, and this association has poor perinatal outcome. Copyright (C) 2011 John Wiley & Sons, Ltd.
Resumo:
Objective: To assess the ability of a three-layer graft in the closuse of large fetal skin defects. Methods: Ovine fetuses underwent a large (4 x 3 cm) full-thickness skin defect over the lumbar region at 105 days` gestation (term = 140 days). A bilaminar artificial skin was placed over a cellulose interface to cover the defect (3-layer graft). The skin was partially reapproximated with a continuous nylon suture. Pregnancy was allowed to continue and the surgical site was submitted to histopathological analysis at different post-operative intervals. Results: Seven fetuses underwent surgery. One maternal/fetal death occurred, and the remaining 6 fetuses were analyzed. Artificial skin adherence to the wound edges was observed in cases that remained in utero for at least 15 days. Neoskin was present beneath the silicone layer of the bilaminar artificial skin. Conclusions: Our study shows that neoskin can develop in the fetus using a 3-layer graft, including epidermal growth beneath the silicone layer of the bilaminar skin graft. These findings suggest that the fetus is able to reepithelialise even large skin defects. Further experience is necessary to assess the quality of this repair.
Resumo:
The aim of this study was to evaluate the arterial and venous blood flow in women who underwent upper limb axillary dissection surgery for the treatment of breast cancer. Sixty women were divided into two groups: group 1 (G1)-30 women who underwent breast surgery with axillary dissection level II or III (55.6 +/- A 8.6 years); group 2 (G2)-control, 30 women with no breast cancer (57.4 +/- A 7.0 years). Blood flow profile was evaluated by a continuous wave ultrasound Doppler device (Nicolet Vascular Versalab SE(A (R))) with an 8 MHz probe. Axillary, brachial arteries and veins, arm circumference, volumes, and the ankle-brachial index (ABI) were examined. Wilcoxon test and Mann-Whitney tests were applied to analyze blood flow velocity intra-group and between G1 and G2, respectively. The G1 results showed no lymphedema and no peripheral arterial disease (ABI > 0.9). Moreover, the mean blood flow velocity of the vessels ipsilateral to the surgery was significantly higher than the contralateral ones for all vessels examined (P < 0.05). The mean velocity of blood flow of the vessels contralateral to surgery was significantly higher than the axillary artery in G2 (P < 0.05). It can be concluded that women who underwent axillary dissection due to breast cancer showed probable stenosis in the arterial and venous axillary and brachial vessels of the upper limb ipsilateral to the surgery, confirmed by the increase of blood flow velocity, and such obstruction might affect the limb contralateral to the operation site.
Resumo:
Background and Aims: Endoscopic ultrasound (EUS) is useful for the treatment of sterile pancreatic fluid collections (PFC), either by means of transmural drainage or by complete aspiration. The aim of this study was to evaluate the efficacy and safety of single-step EUS-guided endoscopic approaches for treatment of sterile PFC. Patients and Methods: During a 3-year period, 77 consecutive patients with symptomatic, persistent sterile PFC were evaluated and treated with the linear EUS. We excluded patients with grossly purulent collections, chronic pseudocyst and those whose cytology diagnostic was neoplastic cyst of pancreas. 44 patients received a single 10-Fr plastic straight stent under EUS or fluoroscopic control (group I) and 33 of these underwent a single-step complete aspiration with a 19-gauge needle (group II). Results: The mean size of the sterile PFC was 48 mm in group I and 28 mm in group II (p < 0.001). Overall, endoscopic treatment was successful in 70 (90.9%) patients. The mean volume aspirated was 25 (18-65) ml. The total number of procedures was 50 in group I and 41 punctures in group II. After a mean follow-up of 64 +/- 15.6 weeks there were 6 complications 13.6%): 2 recurrences (referred to surgery), 2 developing abscesses (submitted a new EUS-guided endoscopic drainage with success), 1 perforation that died (2.2%), and 1 case of bleeding (sent to surgery) in group I. In group II there were only 6 (18.1%) recurrences (submitted a new EUS-guided aspiration). None of the patients undergoing single-step aspiration developed infections, perforation or hemorrhage. Conclusion: The recurrence of pancreatic pseudocysts after endoscopic treatment was similar, either by means of plastic stents or by complete single-step aspiration. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
Background: Most cases of congenital clubfoot treated with the Ponseti technique require percutaneous Achilles tenotomy to correct the residual equinus. Clinical evidence suggests that complete healing occurs between the cut tendon stumps, but there have not yet been any detailed studies investigating this reparative process. This study was performed to assess Achilles tendon repair after percutaneous section to correct the residual equinus of clubfoot treated with the Ponseti method. Method: A prospective study analyzed 37 tenotomies in 26 patients with congenital clubfoot treated with the Ponseti technique, with a minimum follow-up of 1 year after the section. The tenotomy was performed percutaneously with a large-bore needle bevel with patient sedation and local anesthesia. Ultrasonographic scanning was performed after section to ascertain that the tenotomy had been completed and to measure the stump separation. In the follow-up period, the reparative process was followed ultrasonographically and assessed at 3 weeks, 6 months, and 1 year posttenotomy. Results: The ultrasonography performed immediately after the procedure showed that in some cases, residual strands between the tendon ends persisted, and these were completely sectioned under ultrasound control. A mean retraction of 5.65 mm +/- 2.26 mm (range, 2.3 to 11.0 mm) between tendon stumps after section was observed. Unusual bleeding occurred in one case and was controlled by digital pressure, with no interference with the final treatment. After 3 weeks, ultrasonography showed tendon repair with the tendon gap filled with irregular hypoechoic tissue, and also with transmission of muscle motion to the heel. Six months after tenotomy, there was structural filling with a fibrillar aspect, mild or moderate hypoechogenicity, and tendon scar thickening when compared with a normal tendon. One year after tenotomy, ultrasound showed a fibrillar structure and echogenicity at the repair site that was similar to a normal tendon, but with persistent tendon scarring thickness. Conclusions: There is a fast reparative process after Achilles tendon percutaneous section that reestablishes continuity between stumps. The reparative tissue evolved to tendon tissue with a normal ultrasonographic appearance except for mild thickening, suggesting a predominantly intrinsic repair mechanism.
Resumo:
Objective: To analyse the effect of integrated orthodontic treatment, orthognathic surgery and orofacial myofunctional therapy on masseter muscle thickness in patients with class III dentofacial deformity three years after orthognathic surgery. Design: A longitudinal study was conducted on 13 patients with class III dentofacial deformities, denoted here as group P1 (before surgery) and group P3 (same patients 3 years to 3 years and 8 months after surgery). Fifteen individuals with no changes in facial morphology or dental occlusion were assigned to the control group (CG). Masseter muscle ultrasonography was performed in the resting and biting situations in the three groups. Data were analysed statistically by a mixed-effects linear model considering a level of significance of P < 0.05. Results: Significantly higher values (P < 0.01) of masseter muscle thickness (cm) were detected in group P3 (right rest: 0.82 +/- 0.16, left rest: 0.87 +/- 0.21, right bite: 1 +/- 0.22, left bite: 1.04 +/- 0.28) compared to group P1 (right rest: 0.63 +/- 0.19, left rest: 0.64 +/- 0.15, right bite: 0.87 +/- 0.16, left bite: 0.88 +/- 0.14). Between P3 and CG (right rest: 1.02 +/- 0.19, left rest: 1 +/- 0.19, right bite: 1.18 +/- 0.22, left bite: 1.16 +/- 0.22) there was a significant difference on the right side of the muscle (P < 0.05) in both situations and on the left side at rest. Conclusion: The proposed treatment resulted in improved masseter muscle thickness in patients with class III dentofacial deformity. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
We evaluated 16 pregnant women with gestational age between 20 and 32 weeks in acute severe hypertension which were randomly allocated to receive either hydralazine or labetalol. Blood pressure and Doppler ultrasound parameters from maternal uterine and fetal middle cerebral and umbilical arteries were assessed during acute severe hypertension and after treatment. A significant reduction in systolic and diastolic blood pressure was observed in both groups. A significant change in Doppler parameters was observed only in pregnant women who received hydralazine: an increase in uterine arteries resistance index. We concluded that both drugs were highly effective in reducing blood pressure in these women. Despite the observed increase in resistance index of uterine arteries associated with hydralazine, the use of hydralazine and labetalol were not related to any significant changes in fetal Doppler, which is reassuring about the safety of these drugs when treating acute severe hypertension in pregnancy. (E-mail: wpmartins@gmail.com) (C) 2011 World Federation for Ultrasound in Medicine & Biology.
Resumo:
We aim to evaluate intra- and interobserver reproducibility of brachial artery flow-mediated dilation (FMD) and of pulsatility index change (PI-C) 1 min after a 5-min forearm compression in pregnant women. Flow-mediated dilation and PI-C were assessed in 31 healthy pregnant women in 3 consecutive days, by two observers. A broader range of response to the stimulus was observed for PI-C (-58.99%-86.71%) than FMD (2.38%-27.01%). The intraclass correlation coefficients were higher for PI-C than for FMD (intra = 0.90 vs. 0.69, p = 0.047; inter = 0.94 vs. 0.61, p = 0.007). Therefore, PI-C measurements were more reliable than FMD. However, studies comprising of subjects with cardiovascular risk factors relating FMD and PI-C become necessary to validate this method for the study of endothelial dysfunction. (E-mail: wpmartins@gmail.com) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
Resumo:
Objectives To evaluate the presence of false flow three-dimensional (3D) power Doppler signals in `flow-free` models. Methods 3D power Doppler datasets were acquired from three different flow-free phantoms (muscle, air and water) with two different transducers and Virtual Organ Computer-aided AnaLysis was used to generate a sphere that was serially applied through the 3D dataset. The vascularization flow index was used to compare artifactual signals at different depths (from 0 to 6 cm) within the different phantoms and at different gain and pulse repetition frequency (PR F) settings. Results Artifactual Doppler signals were seen in all phantoms despite these being flow-free. The pattern was very similar and the degree of artifact appeared to be dependent on the gain and distance from the transducer. False signals were more evident in the far field and increased as the gain was increased, with false signals first appearing with a gain of 1 dB in the air and muscle phantoms. False signals were seen at a lower gain with the water phantom (-15 dB) and these were associated with vertical lines of Doppler artifact that were related to PRF, and disappeared when reflections were attenuated. Conclusions Artifactual Doppler signals are seen in flow-free phantoms and are related to the gain settings and the distance from the transducer. In the in-vivo situation, the lowest gain settings that allow the detection of blood flow and adequate definition of vessel architecture should be used, which invariably means using a setting near or below the middle of the range available. Additionally, observers should be aware of vertical lines when evaluating cystic or liquid-containing structures. Copyright (C) 2010 ISUOC. Published by John Wiley & Sons, Ltd.
Resumo:
Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
Background Polycystic ovary syndrome (PCOS) is associated with adverse metabolic effects. Some cardiovascular disease (CVD) risk markers are increased in women with PCOS. However, early markers of atherosclerosis are also associated with obesity and insulin resistance, which are related to PCOS. These markers may result either directly from PCOS or indirectly as a consequence of the comorbidities associated with the syndrome. Context To assess the presence of early CVD markers in young, nonobese women with PCOS. Patients Forty women with PCOS and 50 healthy women with regular menstrual cycles, matched for age and body mass index (BMI). Measurements The following CVD markers were assessed by ultrasonography: common carotid artery (CCA) stiffness index (beta), distensibility and intima-media thickness (IMT), and brachial artery flow-mediated dilatation (FMD). Inflammatory markers, including interleukin (IL)-6, tumour necrosis factor (TNF)-alpha, homocysteine, C-reactive protein (CRP), glycaemia, lipid profile and insulin, were also assessed. Results CCA beta was higher in PCOS than in control women (3 center dot 72 +/- 0 center dot 96 vs. 3 center dot 36 +/- 0 center dot 96, P = 0 center dot 04) and CCA distensibility was lower (0 center dot 31 +/- 0 center dot 08 vs. 0 center dot 35 +/- 0 center dot 09 mmHg(-1), P = 0 center dot 02). Waist circumference, total testosterone and the Free Androgen Index (FAI) were higher in PCOS patients than in controls (78 center dot 2 +/- 10 center dot 0 vs. 71 center dot 5 +/- 7 center dot 2 cm, P = 0 center dot 001; 88 center dot 1 +/- 32 center dot 4 vs. 57 center dot 1 +/- 21 center dot 2 ng/dl, P < 0 center dot 01; 12 center dot 7 +/- 15 center dot 7%vs. 4 center dot 7 +/- 2 center dot 3%, P < 0 center dot 01, respectively), while SHBG was reduced (37 center dot 9 +/- 19 center dot 1 vs. 47 center dot 8 +/- 18 center dot 3 nmol/l, P = 0 center dot 01). The remaining variables did not differ between the groups. Conclusions Young women with PCOS exhibit changes in vascular elasticity even in the absence of classical risk factors for CVD, such as hypertension and obesity.
Resumo:
Objective(s): We intend to verify if fetal volume and crown-rump length were different between singletons and twins in pregnancies aged from 7 to 10 weeks and to evaluate if fetal volume is more accurate to determine the gestational age than crown-rump length at this gestational age. Study design: From 52 days (7 weeks and 3 days) to 73 days (10 weeks and 3 days) weekly three-dimensional Ultrasonography was per-formed in 20 twin fetuses and 20 singletons. Crown-rump length and fetal volume using VOCAL were assessed in all examinations. The `true` gestational age was based on oocyte retrieval. Results: At the age of 52 days, the crown-rump length was 11.74 +/- 0.27 mm (mean +/- S.D.) and 11.48 +/- 0.22 mm (singletons and twins, respectively), while the fetal volume was 0.354 +/- 0.015 cm(3) and 0.324 +/- 0.012 cm(3). At the gestational age of 73 days, the crown-rump length was 36.19 +/- 0.90 mm and 35.87 +/- 0.54 mm and the fetal volume was 6.204 +/- 0.090 cm(3) and 6.083 +/- 0.081 cm(3). The total relative increase observed was much higher for fetal volume than for CRL: 1705 +/- 301% vs. 210 +/- 33% in singletons and 1827 +/- 305% vs. 214 +/- 25% in twins. The 95% limits of agreement (+/- 2.3 days vs. +/- 3.2 days, fetal volume vs. crown-rump length) and the intraclass correlation coefficients (0.989 vs. 0.978) between the ""true"" gestational age and that predicted by fetal volume were better than those predicted by crown-rump length. No significant difference was identified between singletons and twins for both fetal volume and crown-rump length. Conclusion(s): Twins and singletons had similar fetal volume and crown-rump length between the 7th and 10th week of gestational age. Additionally, fetal volume assessed by VOCAL was better than crown-rump length to estimate the gestational age at the evaluated period. However, the improvement was small and probably without clinical significance. Condensation: Fetal volume and crown-rump length were similar between singletons and twins. Fetal volume relative increase was higher and the predicted gestational age was better. (c) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
We compared the effects of levonorgestrel-releasing intrauterine devices (LNG-IUD) and a gonadotropin-releasing hormone agonist (GnRHa) on uterine volume, uterine arteries pulsatility index (PI) and endometrial thickness before and after six months of endometriosis treatment. Sixty women aged 18-40 y were allocated randomly to one of two groups: LNG-IUDs were inserted in 30 women, and GnRHa monthly injections were performed on the other 30. All 60 women were submitted to transvaginal 2-D ultrasound scans on the day that the treatment started and then six months later. Measurements of uterine arteries PI, uterine volume and endometrial thickness were performed at both evaluations. The use of LNG-IUDs significantly decreased endometrial thickness (pre = 6.08 +/- 3.00 mm, post = 2.7 +/- 0.98 mm; mean +/- SD), as did the use of GnRHa (pre = 6.96 +/- 3.82 mm, post = 3.23 +/- 2.32 mm). The uterine volume decreased in the GnRHa group (pre = 86.67 +/- 28.38 cm(3), Post = 55.27 +/- 25.52 cm(3)), but not in the LNG-IUD group (pre = 75.77 +/- 20.88 cm(3), post = 75.97 +/- 26.62 cm(3)). Uterine arteries PI increased for both groups; however, the increase was higher in the GnRHa group (0.99 +/- 0.84 vs. 0.38 +/- 0.84, p = 0.007; PI increase in GnRHa and in LNG-IUD groups, respectively). In conclusion, levonorgestrel released directly onto the endometrium by the LNG-IUD induced smaller uterine changes than did the hypoestrogenism induced by GnRHa. Nevertheless, both promoted similar effects on endometrial thickness. (E-mail: wpmartins@gmail.com) (C) 2008 World Federation for Ultrasound in Medicine & Biology.
Resumo:
The aim of this study was to compare the crown-rump length (CRL) and the fetal head and trunk (HT) volume between singletons and twins conceived after in vitro fertilization. Thirty pregnant patients submitted to embryo transfer were enrolled in this research. Ten conceived twins (20 dichorionic fetuses) while other 20 conceived singletons. The gestational age was calculated by adding 14 d to the number of days between the oocyte retrieval and the scheduled ultrasound. Three-dimensional ultrasound scans were performed weekly from 73 d (10 wk and 3 d) to 101 d (14 wk and 3 d) of gestational age. HT volume was assessed by VOCAL using 15 degrees step rotation on the manual mode. The measurement of CRL was performed by using the longitudinal plane of the fetus in the multiplanar view. The CRL and HT volume weekly relative increase were evaluated to compare the growth between singletons and twins. No significant difference was identified, in any analyzed week, when comparing the mean of CRL and HT volume between singletons and twins. Additionally, no significant difference between singletons and twins was noticed when comparing the weekly relative increase, both for CRL and HT volume. However, the weekly relative increase was significantly higher for HT volume than for CRL in every week studied for both singletons and twins. The total relative increase observed between 73 and 101 d was much higher for HT volume than for CRL: 679 +/- 39% versus 138 +/- 18% in singletons and 689 +/- 58% versus 139 +/- 21% in twins (HT volume and CRL, respectively), suggesting that HT volume could more accurately determine the gestational age.