51 resultados para Tendinite calcária pré-vertebral
Resumo:
Aims: Histological grade is one of the most important prognostic factors in breast carcinomas, but poorly differentiated neoplasms still have quite heterogeneous biological behaviour, since they can be genetically classified as basal-like, HER2+ or even luminal. The aim was to analyse the frequency of oestrogen receptor (ER), progesterone receptor (PR) and HER2 expression profiles among breast carcinomas with < 10% tubular formation, and their correlation with classic prognostic factors. Methods and results: One hundred and thirty-four samples of paraffin-embedded tumours were studied retrospectively. The tumours were classified in to four groups by their ER/PR/HER2 profile: (i) ER+ and/or PR+ but HER2-; (ii) ER+ and/or PR+ and HER2+; (iii) ER- and/or PR- but HER2+; and (iv) ER-, PR- and HER2- (triple-negative). The histological features of triple-negative and HER2+ carcinomas overlap. The only difference was the expression of basal cytokeratins (basal CK), which was more frequent among triple-negative carcinomas. Basal-CK expression defined a more aggressive group of tumours, according to the pathological features, regardless of the immunohistochemical profile. Conclusions: Group 1 and 2 tumours (ER+ and/or PR+ tumours with or without HER2 expression) were not statistically different, suggesting that poorly differentiated carcinomas with hormone receptors correspond to the luminal B type of tumour. Among poorly differentiated breast carcinomas, the classic profile associated with basal-CK identifies distinct subtypes equivalent to those seen by genetic classification.
Resumo:
Axial vertebral rotation, an important parameter in the assessment of scoliosis may be identified on X-ray images. In line with the advances in the field of digital radiography, hospitals have been increasingly using this technique. The objective of the present study was to evaluate the reliability of computer-processed rotation measurements obtained from digital radiographs. A software program was therefore developed, which is able to digitally reproduce the methods of Perdriolle and Raimondi and to calculate semi-automatically the rotation degree of vertebra on digital radiographs. Three independent observers estimated vertebral rotation employing both the digital and the traditional manual methods. Compared to the traditional method, the digital assessment showed a 43% smaller error and a stronger correlation. In conclusion, the digital method seems to be reliable and enhance the accuracy and precision of vertebral rotation measurements.
Resumo:
Introduction: The photoelasticity is used for assessing the tensions/deformations involved in photoelastic materials when submitted to a given load by the observation of optical effects. The screw performance and mechanical functions are directly associated to the quality of the screws fixation in the vertebrae. Photoelasticity is an important tool to perform comparative studies of this nature. Objective: The aim of this study was to compare, by using photoelasticity, internal stresses produced by the screw with an external diameter of 6 mm, when submitted to two different pullout strengths. Materials and Methods: For this, four photoelastic models were produced. The simulation was conducted by using two pullout strengths: 0.75 and 1.50 kgf. The maximum shear stresses were calculated on 19 points around the screws, using the Tardy compensation method. Results:The values of maximum shear stress were higher with the load of 1.50 kgf. Conclusion: Thus, the screw will be more susceptible to pullout when heavier loads are applied. According to our analysis, we also found that the site with the highest maximum shear stress was found to be at the peak of creast, particularly near the tips of the screws, regardless of the load employed.
Resumo:
Study Design. In vitro biomechanical investigation of the screw-holding capacity. Objective. To evaluate the effect of repetitive screw-hole use on the insertional torque and retentive strength of vertebral system screws. Summary and Background Data. Placement and removal of vertebral system screws is sometimes necessary during the surgical procedures in order to assess the walls of the pilot hole. This procedure may compromise the holding capacity of the implant. Methods. Screws with outer diameter measuring 5, 6, and 7 mm were inserted into wood, polyurethane, polyethylene, and cancellous bone cylindrical blocks. The pilot holes were made with drills of a smaller, equal, or wider diameter than the inner screw diameter. Three experimental groups were established based on the number of insertions and reinsertions of the screws and subgroups were created according to the outer diameter of the screw and the diameter of the pilot hole used. Results. A reduction of screw-holding capacity was observed between the first and the following insertions regardless the anchorage material. The pattern of reduction of retentive strength was not similar to the pattern of torque reduction. The pullout strength was more pronounced between the first and the last insertions, while the torque decreased more proportionally from the first to the last insertions. Conclusion. Insertion and reinsertion of the screws of the vertebral fixation system used in the present study reduced the insertion torque and screw purchase.
Resumo:
Behavioral problems in preschool children are one of the most frequent motives for seeking psychological care by parents and caregivers. Instruments are considered necessary, created from a Social Skills Training theoretical-practical perspective, which may systematically assist the identification of social skills and behavioral deficits. helping professionals in the prevention and/or reduction of behavioral problems. The purpose of this study was to test the psychometric validity and reliability of an instrument for evaluation of Socially Skilled Responses. from a teacher`s perspective (QRSH-PR). For this purpose, 260 preschool children were evaluated. differentiated in subgroups without and without behavioral difficulties, based on the Child Behavior Scale (Escala de Comportamento Infantil/ECI-Professor). Studies were conducted for construct. discrimination. concurrent and predictive validity. The Cronbach Alpha was calculated to evaluate internal consistency. The obtained results pointed to positive indicators in reference to construct, discrimination, and predictive validity, and even for good internal consistency. indicating that the items consistently measure the construct of social skills, and differentiated children with and without behavioral problems. The questionnaire is considered to be gauged for evaluation of socially skilled responses from preschool children. and applicable in educational and clinical environments.
Resumo:
Study Design. Osteoblastic cells derived from vertebral lamina and iliac crest were isolated and cultured under the same conditions (osteogenic medium, pH, temperature, and CO(2) levels). Objective. To compare proliferation and expression of osteoblastic phenotype of cells derived from vertebral lamina and iliac grafting. Summary of Background Data. Many factors play a role in the success of bone graft in spinal fusion including osteoblastic cell population. Two common sources of graft are vertebral lamina and iliac crest, however, differences in proliferation and osteoblastic phenotype expression between cells from these sites have not been investigated. Methods. Cells obtained from cancellous bone of both vertebral lamina and iliac crest were cultured and proliferation was evaluated by direct cell counting and viability detected by Trypan blue. Alkaline phosphatase (ALP) activity was evaluated by thymolphthalein release from thymolphthalein monophosphate and matrix mineralization by staining with alizarin red S. Gene expression of ALP, osteocalcin, runt-related transcription factor 2, Msh homeobox 2, bone morphogenetic protein 7, intercellular adhesion molecule 1 precursor, osteoprotegerin, and receptor activator of NF-kB ligand was analyzed by real-time PCR. All comparisons were donor-matched. Results. Proliferation was greater at days 7 and 10 in cells from vertebral lamina compared with ones from iliac crest without difference in cell viability. ALP activity was higher in cells from vertebral lamina compared with cells from iliac crest at days 7 and 10. At 21 days, mineralized matrix was higher in cells derived from vertebral lamina than from iliac crest. At day 7, gene expression of ALP, osteocalcin, runt-related transcription factor 2, Msh homeobox 2, bone morphogenetic protein 7, intercellular adhesion molecule 1 precursor, receptor activator of NF-kB ligand, and osteoprotegerin was higher in cells derived from vertebral lamina compared with iliac crest. Conclusion. Cell proliferation and osteoblastic phenotype development in cells derived from cancellous bone were more exuberant in cultures of vertebral lamina than of iliac crest.