57 resultados para Post and core technique


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Anterior ethmoidal artery (AEA) ligation may be necessary in cases of severe epistaxis not controllable with traditional therapy. Endoscopic endonasal ligation of the AEA is not used frequently; there are few studies in the literature for standardization of the endoscopic technique for this vessel. Aim: To demonstrate the feasibility of periorbital AEA ligation in a transethmoidal endoscopic approach. Methods: A prospective study where 50 nasal cavities were dissected. After anterior ethmoidectomy and partial removal of lamina papyracea, the periorbital area was carefully dissected along a subperiosteal plane to identify the AEA. The vessel was exposed within the orbit and dissected. Results: Data on technical difficulties, complications, the learning curve and anatomical variations were gathered. Conclusion: An endonasal endoscopic approach to the AEA within the orbit was shown to be feasible. Identifying the artery is not difficult, and this technique avoids external incisions. This approach appears to be an excellent alternative for approaching the AEA. Further clinical studies are needed to demonstarte the benefits of this technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives/Hypothesis: Blood supply to the Hadad-Bassagasteguy pedicled nasoseptal flap may be interrupted by surgery of the pterygopalatine fossa, posterior septectomy, or large sphenoidotomies. This would preclude its use for reconstruction of skull base defects after expanded endonasal approaches (EEA). We present a novel method to ascertain the patency of the nasoseptal artery after prior surgery, and consequently the availability of the nasoseptal flap, using acoustic Doppler sonography. Study Design: Retrospective clinical review. Methods: Four patients who underwent EEAs were evaluated intraoperatively with acoustic Doppler sonography. The mucosa that covers the inferior aspect of the rostrum of the sphenoid sinus was scanned with the tip of the probe. Reflection of sound waves representing intravascular blood flow was assessed. Results: In three patients, the artery was identified in at least one side. One remaining patient showed no acoustic signal suggesting loss of the nasoseptal artery bilaterally, therefore necessitating the use of a fat graft for the reconstruction. Conclusions: Acoustic Doppler sonography seems to be a feasible and effective way to ascertain the availability of the nasoseptal artery. It is a relatively inexpensive and simple technique that can be performed by any endoscopic surgeon.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To describe the use of self-expandable metallic stents to manage malignant colorectal obstructions and to compare the radiation dose between fluoroscopic guidance of stent placement and combined endoscopic and fluoroscopic guidance. Materials and Methods: From January 1998 to December 2007, 467 oncology patients undergoing colorectal stent placement in a single center were included in the study. Informed consent was obtained in all cases. All procedures were performed with fluoroscopic or combined fluoroscopic and endoscopic guidance. Inclusion criteria were total or partial colorectal obstruction of neoplastic origin. Exclusion criteria were life expectancy shorter than I month, suspicion of perforation, and/or severe colonic neoplastic bleeding. Procedure time and radiation dose were recorded, and technical and clinical success were evaluated. Follow-up was performed by clinical examination and simple abdominal radiographs at 1 day and at I, 3, 6, and 12 months. Results: Of 467 procedures, technical success was achieved in 432 (92.5%). Thirty-five treatments (7.5%) were technical failures, and the patients were advised to undergo surgery. Significant differences in radiation dose and clinical success were found between the fluoroscopy and combined-technique groups (P < .001). Total decompression was achieved in 372 cases, 29 patients showed remarkable improvement, 11 showed slight improvement, and 20 showed clinical failure. Complications were recorded in 89 patients (19%), the most significant were perforation (2.3%) and stent migration (6.9%). Mean interventional time and radiation dose were 67 minutes and 3,378 dGy.cm(2), respectively. Conclusions: Treatment of colonic obstruction with stents requires a long time in the interventional room and considerable radiation dose. Nevertheless, the clinical benefits and improvement in quality of life justify the radiation risk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are many techniques for the treatment of hip dysplasia, and novel research is currently being undertaken in the hope of obtaining more efficient and less traumatic techniques. The denervation of the hip joint capsule is a simple and effective technique that allows recovery of the functional activity of the affected limbs in significantly less time than other techniques. This surgical procedure consists of removing the acetabular periosteum, thus eliminating the nerve fibres with consequent analgesia. The aim of this investigation was to quantify the number of nerve fibres present in different regions of the acetabular periosteum. The knowledge of regional differences is potentially valuable for the refining of the denervation technique of the hip joint capsule. Thirty canine acetabular fragments were used to compare the nerve fibre density of the periosteum. The results showed a significant difference between the mean density of nerve fibres at the cranial and dorsal-lateral portion (approximately 75 fibres/mm(2)) and caudal lateral portion (approximately 60 fibres/mm(2)) of the acetabulum. Those fibres at the pedosteum are almost positioned in a sagittal plane, pointing towards the joint capsule, suggesting the some density in the latter region. These results indicate a new approach to the articular denervation technique, thus obtanining even better results for the treatment of hip dysplasia in dogs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bilateral cysts in the frontal and caudal maxillary sinuses in a filly created by endoscopic Sinus surgery, (sinoscopy) and triangulation technique are described. Sinoscopy has the advantage of being a minimally invasive technique and permits a complete inspection of the frontal and maxillary sinuses, which is not possible through flap sinusotomy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To test the strength to failure and fracture mode of three indirect composite materials directly applied onto Ti-6Al-4V implant abutments vs cemented standard porcelain-fused-to-metal (PFM) crowns. Materials and Methods: Sixty-four locking taper abutments were randomly allocated to four groups and were cleaned in ethanol in an ultrasonic bath for 5 min. After drying under ambient conditions, the abutments were grit blasted and a custom 4-cusp molar crown mold was utilized to produce identical crowns (n = 16 per group) of Tescera (Bisco), Ceramage (Shofu), and Diamond Crown (DRM) according to the manufacturer`s instructions. The porcelain-fused-to-metal crowns were fabricated by conventional means involving the construction and a wax pattern and casting of a metallic coping followed by sintering of increasing layers of porcelain. All crowns were loaded to failure by an indenter placed at one of the cusp tips at a 1 mm/min rate. Subsequently, fracture analysis was performed by means of stereomicroscopy and scanning electron microscopy. One-way ANOVA at 95% level of significance was utilized for statistical analysis. Results: The single load to failure (+/- SD) results were: Tescera (1130 +/- 239 N), Ceramage (1099 +/- 257 N), Diamond Crown (1155 +/- 284 N), and PFM (1081 +/- 243 N). Stereomicroscopy analysis showed two distinct failure modes, where the loaded cusp failed either with or without abutment/metallic coping exposure. SEM analysis of the fractures showed multiple crack propagation towards the cervical region of the crown below a region of plastic deformation at the indenter contact region. Conclusion: The three indirect composites and PFM systems fractured at loads higher than those typically associated with normal occlusal function. Although each material had a different composition and handling technique, no significant differences were found concerning their single load to fracture resistance among composite systems and PFM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: This study evaluated the bond strength of translucent fiber posts to experimentally weakened radicular dentin restored with composite resin and polymerized with different light-exposure time. Methods: Roots of 60 maxillary incisors were used. Twenty-four hours after obturation, the filling materials of root canals were removed to a depth of 12 mm, and 4 groups were randomly formed. In 3 groups, root dentin was flared to produce a space between fiber post and canal walls. In the control group, the roots were not experimentally weakened. The flared roots were bulk restored with composite resin, which was light-activated through the translucent post for 40, 80, or 120 seconds. Posts were cemented, and after 24 hours, all roots were sectioned transversely in the coronal, middle, and apical regions, producing 1-mm-thick slices. Push-out test was performed, and failure modes were observed. Results The quantitative analysis showed significant statistical difference only among groups (P <.001). Comparing the weakened/restored groups, composite light-exposure time did not influence the results. Overall, adhesive failures occurred more frequently than other types of failures. Cohesive failures occurred only in the weakened/restored roots. Conclusions Intracanal root restoration with composite resin and translucent fiber posts provided similar or higher bond strength to dentin than the control group, regardless of the light-exposure time used for polymerization. (J Endod 2009;35:1034-1039)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The aim of this study was to verify the influence of endodontic sealers on the bond strength of an adhesive system and a resin cement used for carbon posts cementation. Methods: Thirty extracted human premolars were instrumented and randomly divided into three groups according to the tested sealer: EndoFill, Sealapex, or EndoREZ. Specimens were stored at 37 degrees C. After 48 h, half of specimens were prepared to receive the post and the others after 7 days. The posts were cemented with Adper Single Bond/Rely X ARC and stored in distilled water at 37 degrees C for 7 days. After this period, the specimens were sectioned in three slices (coronal, middle, and apical). The push-out test was performed in a universal machine and the debonded area was examined in a stereomicroscope. Results: Data were submitted ANOVA and Tukey test (alpha = 0.05). The EndoFill showed lower bond strength than other sealers (p < 0.01). The EndoREZ sealer was statistically greater than other groups for coronal and middle portions and similar for apical portion (P > 0.05). Coronal and middle portions showed the best results for all groups, mainly when the canal preparation was performed after 48 h (p < 0.01). Mixed failure occurs with more frequency (55.6%) followed by failure in adhesive-dentin interface (34.4%) and adhesive-post interface (10.0%). Conclusion: The use of EndoREZ sealer promoted higher bond strength in root coronal and middle portions when carbon post was fixed with a resin cement. (C) 2007 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this research was to evaluate the plasticizing effect of natural surfactants lecithin or yucca extract from Yucca schidigera on gelatin-based films Films containing yucca extract showed higher tensile strength values (similar to 90-40 MPa) and moisture contents (similar to 15%) and less elongation (similar to 5%) and water vapor permeability values (similar to 0 22-009 g mm m(-2) h(-1) kPa(-1)) compared to films containing lecithin Soluble films (similar to 20-50%) were obtained when yucca extract was used while lecithin produced low soluble films (<10%) The opacity of the films (similar to 14 5-16 2%) was similar for both surfactants and the film surface morphologies were continuous and homogeneous X-ray diffraction indicated that the addition of surfactants produced amorphous films compared to gelatin-based films and FT-Infrared spectroscopy showed no evidence of association between the surfactants and the gelatin The plasticizing effect was not obtained after surfactants addition and casting technique (C) 2010 Elsevier Ltd All rights reserved

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bismuth germanate films were prepared by dip coating and spin coating techniques and the dependence of the luminescent properties of the samples on the resin viscosity and deposition technique was investigated. The resin used for the preparation of the films was obtained via Pechini method, employing the precursors Bi(2)O(3) and GeO(2). Citric acid and ethylene glycol were used as chelating and cross-linking agents, respectively. Results from X-ray diffraction and Raman spectroscopy indicated that the films sintered at 700 degrees C for 10 h presented the single crystalline phase Bi(4)Ge(3)O(12). SEM images of the films have shown that homogeneous flat films can be produced by the two techniques investigated. All the samples presented the typical Bi(4)Ge(3)O(12) emission band centred at 505 nm. Films with 3.1 mu m average thickness presented 80% of the luminescence intensity registered for the single crystal at the maximum wavelength. Published by Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microelectrode cyclic voltammetry (MV) has been employed to investigate the micellar properties of solutions of homologous alkyltrimethylammonium bromides, RMe(3)ABr, R = C(10), C(12), and C(14), in water and in the presence of added NaBr. The micellar self-diffusion coefficient was calculated from the limiting current for the reversible electron transfer of micelle-bound ferrocene. From the values of this property, other parameters were calculated, including the micellar hydrodynamic radius, RH, and aggregation number, N(agg); the latter was also theoretically calculated. We determined the values of the diffusion coefficient as a function of various experimental variables and observed the following trends: The diffusion coefficient decreases as a function of increasing surfactant concentration (no additional electrolyte added); it decreases as a function of increasing surfactant concentration at fixed NaBr concentration; and it shows a complex dependence (increase then decrease) on the NaBr concentration at a fixed RMe(3)ABr concentration. The value of the intermicellar interaction parameter decreases and then increases as a function of increasing NaBr concentration. These results are discussed in terms of intermicellar,interactions and the effect of NaBr on the micellar surface charge density and sphere-to-rod geometry change. The NaBr concentration required to induce the latter change increases rapidly as a function of decreasing the length of R: no geometry change was detected for C(10)Me(3)ABr. Values of N(agg) increase as I function of increasing the length of R and are in good agreement with both literature values and values that were calculated theoretically. Thus, MV is a convenient and simple technique for obtaining fundamental properties of surfactant solutions, including additive-induced changes of micellar parameters (N(agg)) and morphology changes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CCSD(T) with a series of correlation consistent basis up to quadruple-zeta is used to investigate the structures, vibrational spectra, relative stability, heats of formation, and barrier to isomerization of S=SBr2 and BrSSBr. It represents the most accurate and detailed characterization of these molecules to date. We show that the frequency mode at 302 cm(-1), detected in various studies and assigned to impurities by some authors, and to the anti-symmetric SBr stretch in BrSSBr by others, thus in fact corresponds to the anti-symmetric SBr stretch in the elusive S=SBr2 species; it thus corroborates and complements an earlier partial IR spectra study attributable to S=SBr2. Including corrections for relativistic and core-valence correlation effects, we also predict 26.33 (12.74) kcal/mol for Delta H-f (298.15 K) of S=SBr2 (BrSSBr). For the S=SBr2 -> BrSSBr reaction, our best estimates for the Gibbs free energy and the enthalpy of the reaction at 298.15 K are -13.71 and -13.44 kcal/mol, respectively. For a value of Delta G(#) equal to 23.52 kcal/mol, we estimate a TST rate constant, at 298.15 K, of 3.57 x 10(-5) s(-1). (c) 2007 Elsevier B.V. All rights reserved.