119 resultados para Percutaneous coronary intervention


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objectives Low bone mineral density and coronary artery calcification (CAC) are highly prevalent among chronic kidney disease (CKD) patients, and both conditions are strongly associated with higher mortality. The study presented here aimed to investigate whether reduced vertebral bone density (VBD) was associated with the presence of CAC in the earlier stages of CKD. Design, setting, participants, & measurements Seventy-two nondialyzed CKD patients (age 52 +/- 11.7 years, 70% male, 42% diabetics, creatinine clearance 40.4 +/- 18.2 ml/min per 1.73 m(2)) were studied. VBD and CAC were quantified by computed tomography. Results CAC > 10 Agatston units (AU) was observed in 50% of the patients (median 120 AU [interquartile range 32 to 584 AU]), and a calcification score >= 400 AU was found in 19% (736 [527 to 1012] AU). VBD (190 +/- 52 Hounsfield units) correlated inversely with age (r = -0.41, P < 0.001) and calcium score (r = -0.31, P = 0.01), and no correlation was found with gender, creatinine clearance, proteinuria, lipid profile, mineral parameters, body mass index, and diabetes. Patients in the lowest tertile of VBD had expressively increased calcium score in comparison to the middle and highest tertile groups. In the multiple logistic regression analysis adjusting for confounding variables, low VBD was independently associated with the presence of CAC. Conclusions Low VBD was associated with CAC in nondialyzed CKD patients. The authors suggest that low VBD might constitute another nontraditional risk factor for cardiovascular disease in CKD. Clin J Am Soc Nephrol 6: 1456-1462, 2011. doi: 10.2215/CJN.10061110

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective ""CORE-64"" trial (""Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors""). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Vascular calcification is common and constitutes a prognostic marker of mortality in the hemodialysis population. Derangements of mineral metabolism may influence its development. The aim of this study is to prospectively evaluate the association between bone remodeling disorders and progression of coronary artery calcification (CAC) in hemodialysis patients. Study Design: Cohort study nested within a randomized controlled trial. Setting & Participants: 64 stable hemodialysis patients. Predictor: Bone-related laboratory parameters and bone histomorphometric characteristics at baseline and after 1 year of follow-up. Outcomes: Progression of CAC assessed by means of coronary multislice tomography at baseline and after 1 year of follow-up. Baseline calcification score of 30 Agatston units or greater was defined as calcification. Change in calcification score of 15% or greater was defined as progression. Results: Of 64 patients, 26 (40%) had CAC at baseline and 38 (60%) did not. Participants without CAC at baseline were younger (P < 0.001), mainly men (P = 0.03) and nonwhite (P = 0.003), and had lower serum osteoprotegerin levels (P = 0.003) and higher trabecular bone volume (P = 0.001). Age (P 0.003; beta coefficient = 1.107; 95% confidence interval [Cl], 1.036 to 1.183) and trabecular bone volume (P = 0.006; beta coefficient = 0.828; 95% Cl, 0.723 to 0.948) were predictors for CAC development. Of 38 participants who had calcification at baseline, 26 (68%) had CAC progression in 1 year. Progressors had lower bone-specific alkaline phosphatase (P = 0.03) and deoxypyridinoline levels (P = 0.02) on follow-up, and low turnover was mainly diagnosed at the 12-month bone biopsy (P = 0.04). Low-turnover bone status at the 12-month bone biopsy was the only independent predictor for CAC progression (P = 0.04; beta coefficient = 4.5; 95% Cl, 1.04 to 19.39). According to bone histological examination, nonprogressors with initially high turnover (n = 5) subsequently had decreased bone formation rate (P = 0.03), and those initially with low turnover (n = 7) subsequently had increased bone formation rate (P = 0.003) and osteoid volume (P = 0.001). Limitations: Relatively small population, absence of patients with severe hyperparathyroidism, short observational period. Conclusions: Lower trabecular bone volume was associated with CAC development, whereas improvement in bone turnover was associated with lower CAC progression in patients with high- and low-turnover bone disorders. Because CAC is implicated in cardiovascular mortality, bone derangements may constitute a modifiable mortality risk factor in hemodialysis patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The accuracy of multidetector computed tomographic (CT) angiography involving 64 detectors has not been well established. Methods: We conducted a multicenter study to examine the accuracy of 64-row, 0.5-mm multidetector CT angiography as compared with conventional coronary angiography in patients with suspected coronary artery disease. Nine centers enrolled patients who underwent calcium scoring and multidetector CT angiography before conventional coronary angiography. In 291 patients with calcium scores of 600 or less, segments 1.5 mm or more in diameter were analyzed by means of CT and conventional angiography at independent core laboratories. Stenoses of 50% or more were considered obstructive. The area under the receiver-operating-characteristic curve (AUC) was used to evaluate diagnostic accuracy relative to that of conventional angiography and subsequent revascularization status, whereas disease severity was assessed with the use of the modified Duke Coronary Artery Disease Index. Results: A total of 56% of patients had obstructive coronary artery disease. The patient-based diagnostic accuracy of quantitative CT angiography for detecting or ruling out stenoses of 50% or more according to conventional angiography revealed an AUC of 0.93 (95% confidence interval [CI], 0.90 to 0.96), with a sensitivity of 85% (95% CI, 79 to 90), a specificity of 90% (95% CI, 83 to 94), a positive predictive value of 91% (95% CI, 86 to 95), and a negative predictive value of 83% (95% CI, 75 to 89). CT angiography was similar to conventional angiography in its ability to identify patients who subsequently underwent revascularization: the AUC was 0.84 (95% CI, 0.79 to 0.88) for multidetector CT angiography and 0.82 (95% CI, 0.77 to 0.86) for conventional angiography. A per-vessel analysis of 866 vessels yielded an AUC of 0.91 (95% CI, 0.88 to 0.93). Disease severity ascertained by CT and conventional angiography was well correlated (r=0.81; 95% CI, 0.76 to 0.84). Two patients had important reactions to contrast medium after CT angiography. Conclusions: Multidetector CT angiography accurately identifies the presence and severity of obstructive coronary artery disease and subsequent revascularization in symptomatic patients. The negative and positive predictive values indicate that multidetector CT angiography cannot replace conventional coronary angiography at present. (ClinicalTrials.gov number, NCT00738218.).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although a new protocol of dobutamine stress echocardiography with the early injection of atropine (EA-DSE) has been demonstrated to be useful in reducing adverse effects and increasing the number of effective tests and to have similar accuracy for detecting coronary artery disease (CAD) compared with conventional protocols, no data exist regarding its ability to predict long-term events. The aim of this study was to determine the prognostic value of EA-DSE and the effects of the long-term use of beta blockers on it. A retrospective evaluation of 844 patients who underwent EA-DSE for known or suspected CAD was performed; 309 (37%) were receiving beta blockers. During a median follow-up period of 24 months, 102 events (12%) occurred. On univariate analysis, predictors of events were the ejection fraction (p <0.001), male gender (p <0.001), previous myocardial infarction (p <0.001), angiotensin-converting enzyme inhibitor therapy (p = 0.021), calcium channel blocker therapy (p = 0.034), and abnormal results on EA-DSE (p <0.001). On multivariate analysis, the independent predictors of events were male gender (relative risk [RR] 1.78, 95% confidence interval [CI] 1.13 to 2.81, p = 0.013) and abnormal results on EA-DSE (RR 4.45, 95% CI 2.84 to 7.01, p <0.0001). Normal results on EA-DSE with P blockers were associated with a nonsignificant higher incidence of events than normal results on EA-DSE without beta blockers (RR 1.29, 95% CI 0.58 to 2.87, p = 0.54). Abnormal results on EA-DSE with beta blockers had an RR of 4.97 (95% CI 2.79 to 8.87, p <0.001) compared with normal results, while abnormal results on EA-DSE without beta blockers had an RR of 5.96 (95% CI 3.41 to 10.44, p <0.001) for events, with no difference between groups (p = 0.36). In conclusion, the detection of fixed or inducible wall motion abnormalities during EA-DSE was an independent predictor of long-term events in patients with known or suspected CAD. The prognostic value of EA-DSE was not affected by the long-term use of beta blockers. (C) 2008 Elsevier Inc. All rights reserved. (Am J Cardiol 2008;102:1291-1295)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We sought to evaluate this ""response-to-injury"" hypothesis of atherosclerosis by studying the interaction between systolic blood pressure (SBP) and LDL-cholesterol (LDL-C) in predicting the presence of coronary artery calcification (CAC) in asymptomatic men. We Studied 526 men (46 +/- 7 years of age) referred for electron-beam tomography (EBT) exam. The prevalence of CAC was determined across LDL-C tertiles (low: <115 mg/dl; middle: 115-139 mg/dl high: >= 140 mg/dl) within tertiles of SBP (low: <121 mmHg; middle: 121-130 mmHg; high: >= 131 mmHg). CAC was found in 220 (42%) men. There was no linear trend in the presence of CAC across LDL-C tertiles in the low (p = 0.6 for trend) and middle (p = 0.3 for trend) SBP tertile groups, respectively. In contrast, there was a significant trend for increasing CAC with increasing LDL-C (1st: 44%; 2nd: 49%; 3rd: 83%; p < 0.0001 for trend) in the high SBP tertile group. In multivariate logistic analyses (adjusting for age, smoking, triglyceride levels, HDL-cholesterol levels, body mass index, and fasting glucose levels), the odds ratio for any CAC associated with increasing LDL-C was significantly higher in those with highest SBP levels, whereas no such relationship was observed among men with SBP in the lower two tertiles. An interaction term (LDL-C x SBP) incorporated in the multivariate analyses was statistically significant (p = 0.038). The finding of an interaction between SBP and LDL-C relation to CAC in asymptomatic men support the response-to-injury model of atherogenesis. (C) 2007 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE. Coronary MDCT angiography has been shown to be an accurate noninvasive tool for the diagnosis of obstructive coronary artery disease (CAD). Its sensitivity and negative predictive value for diagnosing percentage of stenosis are unsurpassed compared with those of other noninvasive testing methods. However, in its current form, it provides no information regarding the physiologic impact of CAD and is a poor predictor of myocardial ischemia. CORE320 is a multicenter multinational diagnostic study with the primary objective to evaluate the diagnostic accuracy of 320-MDCT for detecting coronary artery luminal stenosis and corresponding myocardial perfusion deficits in patients with suspected CAD compared with the reference standard of conventional coronary angiography and SPECT myocardial perfusion imaging. CONCLUSION. We aim to describe the CT acquisition, reconstruction, and analysis methods of the CORE320 study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Aims: Calcium-containing phosphate binders have been shown to increase the progression of vascular calcification in hemodialysis patients. This is a prospective study that compares the effects of calcium acetate and sevelamer on coronary calcification (CAC) and bone histology. Methods: 101 hemodialysis patients were randomized for each phosphate binder and submitted to multislice coronary tomographies and bone biopsies at entry and 12 months. Results: The 71 patients who concluded the study had similar baseline characteristics. On follow-up, the sevelamer group had higher levels of intact parathyroid hormone (498 +/- 352 vs. 326 +/- 236 pg/ml, p = 0.017), bone alkaline phosphatase (38 +/- 24 vs. 28 +/- 15 U/l, p = 0.03) and deoxypyridinoline (135 +/- 107 vs. 89 +/- 71 nmol/l, p = 0.03) and lower LDL cholesterol (74 +/- 21 vs. 91 +/- 28 mg/dl, p = 0.015). Phosphorus (5.8 +/- 1.0 vs. 6 +/- 1.0 mg/dl, p = 0.47) and calcium (1.27 +/- 0.07 vs. 1.23 +/- 0.08 mmol/l, p = 0.68) levels did not differ between groups. CAC progression (35 vs. 24%, p = 0.94) and bone histological diagnosis at baseline and 12 months were similar in both groups. Patients of the sevelamer group with a high turnover at baseline had an increase in bone resorption (eroded surface, ES/BS = 9.0 +/- 5.9 vs. 13.1 +/- 9.5%, p = 0.05), whereas patients of both groups with low turnover at baseline had an improvement in bone formation rate (BFR/BS = 0.015 +/- 0.016 vs. 0.062 +/- 0.078, p = 0.003 for calcium and 0.017 +/- 0.016 vs. 0.071 +/- 0.084 mu m(3)/mu m(2)/day, p = 0.010 for sevelamer). Conclusions: There was no difference in CAC progression or changes in bone remodeling between the calcium and the sevelamer groups. Copyright (C) 2008 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of cross-sectional arc calcification on the diagnostic accuracy of computed tomography (CT) angiography compared with conventional coronary angiography for the detection of obstructive coronary artery disease (CAD). Materials and Methods: Institutional Review Board approval and written informed consent were obtained from all centers and participants for this HIPAA-compliant study. Overall, 4511 segments from 371 symptomatic patients (279 men, 92 women; median age, 61 years [interquartile range, 53-67 years]) with clinical suspicion of CAD from the CORE-64 multi-center study were included in the analysis. Two independent blinded observers evaluated the percentage of diameter stenosis and the circumferential extent of calcium (arc calcium). The accuracy of quantitative multidetector CT angiography to depict substantial (>50%) stenoses was assessed by using quantitative coronary angiography (QCA). Cross-sectional arc calcium was rated on a segment level as follows: noncalcified or mild (<90 degrees), moderate (90 degrees-180 degrees), or severe (>180 degrees) calcification. Univariable and multivariable logistic regression, receiver operation characteristic curve, and clustering methods were used for statistical analyses. Results: A total of 1099 segments had mild calcification, 503 had moderate calcification, 338 had severe calcification, and 2571 segments were noncalcified. Calcified segments were highly associated (P < .001) with disagreement between CTA and QCA in multivariable analysis after controlling for sex, age, heart rate, and image quality. The prevalence of CAD was 5.4% in noncalcified segments, 15.0% in mildly calcified segments, 27.0% in moderately calcified segments, and 43.0% in severely calcified segments. A significant difference was found in area under the receiver operating characteristic curves (noncalcified: 0.86, mildly calcified: 0.85, moderately calcified: 0.82, severely calcified: 0.81; P < .05). Conclusion: In a symptomatic patient population, segment-based coronary artery calcification significantly decreased agreement between multidetector CT angiography and QCA to detect a coronary stenosis of at least 50%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background-The proximity to vascular structures is a limiting factor during radiofrequency ablation. However, little or no attention has been given to the atrial arterial circulation during the development of atrial fibrillation (AF) catheter ablation techniques. Methods and Results-We examined the atrial arterial circulation in areas involved in AF ablation in 24 heart specimens by colored resin injection and careful dissection. The sinus node artery (SNA) arose from the circumflex artery in 42% of case; proximal to the LA appendage in 29%, crossing the left atrium (LA) anterior wall; and after the LA appendage in the remaining 13%, crossing the mitral isthmus and passing close to the left pulmonary veins (PVs), the LA roof, and the right superior PV. In 58%, the SNA arose from the right coronary artery. Major arteries (>= 1 mm in external diameter) were found in the mitral isthmus in 54%, at the LA roof in 54%, and at the LA anterior wall in 29%. Around the left PV ostia, there were areas with major arteries in up to 37% (at the roof and inferior segments) and around the right PV ostia in up to 29% (at the roof segment). Conclusions-Major atrial coronary arteries, including the SNA, were commonly found in the areas involved in AF ablation and could cause difficulties in obtaining transmural lesions and electric isolation or even lead to ischemic sinus node or atrial dysfunction. (Circ Arrhythm Electrophysiol. 2010;3:600-605.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This analysis of the Lipid Treatment Assessment Project 2 population compared lipid goal attainment by diabetes and metabolic syndrome status. Research design and methods: Dyslipidaemic patients aged >= 20 years on stable lipid lowering therapy had their lipid levels determined once during enrolment at investigation sites in nine countries between September 2006 and April 2007. Achievement of low-density lipoprotein (LDL) cholesterol success, triglycerides < 150 mg/dl (1.7 mmol/l), and high-density lipoprotein (HDL) cholesterol success (> 40 mg/dl [1.0 mmol/l] in men or > 50 mg/dl [1.3 mmol/l] in women) was compared using logistic regression. Results: A total of 9955 patients were evaluated. Patients with diabetes, compared with those without diabetes, had lower achievement of LDL cholesterol goals (according to National Cholesterol Education Program Adult Treatment Panel [NCEP ATP] III guidelines; 67% vs. 75%), triglycerides < 150 mg/dl (55% vs. 64%), and HDL cholesterol success (61% vs. 74%; p < 0.0001 for all comparisons). The significantly lower lipid goal attainment in patients with diabetes was consistent across participating world regions. Patients with metabolic syndrome, compared with those without metabolic syndrome, had lower achievement of NCEP ATP III LDL cholesterol goals (69% vs. 76%), triglycerides < 150 mg/dl (36% vs. 83%), and HDL cholesterol success (49% vs. 89%; p < 0.0001 for all comparisons). As the number of metabolic syndrome components increased, lipid success rates progressively decreased (p < 0.0001 for LDL cholesterol success, triglycerides < 150 mg/dl, and HDL cholesterol success). Conclusions: This analysis indicates that despite their increased cardiovascular risk, patients with diabetes or metabolic syndrome remain undertreated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: There remains significant concern about the long-term safety of drug-eluting stents (DES). However, bare metal stents (BMS) have been used safely for over two decades. There is therefore a pressing need to explore alternative strategies for reducing restenosis with BMS. This study was designed to examine whether IVUS-guided cutting balloon angioplasty (CBA) with BMS could convey similar restenosis rates to DES. Methods and results: In the randomised REstenosis reDUction by Cutting balloon angioplasty Evaluation (REDUCE III) study, 521 patients were divided into four groups based on device and IVUS use before BMS (IVUS-CBA-BMS: 137 patients; Angio-CBA-BMS: 123; IVUS-BA-BMS: 142; and Angio-BA-BMS: 119). At follow-up, the IVUS-CBA-BMS group had a significantly lower restenosis rate (6.6%) than the other groups (p=0.016). We performed a quantitative coronary angiography (QCA) based matched comparison between an IVUS-guided CBA-BMS strategy (REDUCE III) and a DES strategy (Rapamycin-Eluting-Stent Evaluation At Rotterdam Cardiology. Hospital, the RESEARCH study). We matched the presence of diabetes, vessel size, and lesion severity by QCA. Restenosis (>50% diameter stenosis at follow-up) and target vessel revascularisation (TVR) were examined. QCA-matched comparison resulted in 120-paired lesions. While acute gain was significantly greater in IVUS-CBA-BMS than DES (1.65 +/- 0.41 mm vs. 1.28 +/- 0.57 mm, p=0.001), late loss was significantly less with DES than with IVUS-CBA-BMS (0.03 +/- 0.42 mm vs. 0.80 +/- 0.47 mm, p=0.001). However, no difference was found in restenosis rates (IVUS-CBA-BMS: 6.6% vs. DES: 5.0%, p=0.582) and TVR (6.6% and 6.6%, respectively). Conclusions: An IVUS-guided CBA-BMS strategy yielded restenosis rates similar to those achieved by DES and provided an effective alternative to the use of DES.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, stress myocardial computed tomographic perfusion (CTP) was shown to detect myocardial ischemia. Our main objective was to evaluate the feasibility of dipyridamole stress CTP and compare it to single-photon emission computed tomography (SPECT) to detect significant coronary stenosis using invasive conventional coronary angiography (CCA; stenosis >70%) as the reference method. Thirty-six patients (62 +/- 8 years old, 20 men) with previous positive results with SPECT (<2 months) as the primary inclusion criterion and suspected coronary artery disease underwent a customized multidetector-row CT protocol with myocardial perfusion evaluation at rest and during stress and coronary CT angiography (CTA). Multidetector-row computed tomography was performed in a 64-slice scanner with dipyridamole stress perfusion acquisition before a second perfusion/CT angiographic acquisition at rest. Independent blinded observers performed analysis of images from CTP, CTA, and CCA. All 36 patients completed the CT protocol with no adverse events (mean radiation dose 14.7 +/- 3.0 mSv) and with interpretable scans. CTP results were positive in 27 of 36 patients (75%). From the 9 (25%) disagreements, 6 patients had normal coronary arteries and 2 had no significant stenosis (8 false-positive results with SPECT, 22%). The remaining patient had an occluded artery with collateral flow confirmed by conventional coronary angiogram. Good agreement was demonstrated between CTP and SPECT on a per-patient analysis (kappa 0.53). In 26 patients using CCA as reference, sensitivity, specificity, and positive and negative predictive values were 88.0%, 79.3%, 66.7%, and 93.3% for CTP and 68.8, 76.1%, 66.7%, and 77.8%, for SPECT, respectively (p = NS). In conclusion, dipyridamole CT myocardial perfusion at rest and during stress is feasible and results are similar to single-photon emission CT scintigraphy. The anatomical-perfusion information provided by this combined CT protocol may allow identification of false-positive results by SPECT. (C) 2010 Elsevier Inc. All rights reserved. (Am J Cardiol 2010;106:310-315)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/Purpose: Central venous catheterization is among the most common procedures performed by pediatric surgeons. Significant morbidity and even mortality can ensue from the widespread approach to the deep veins of the neck and femoral region. The external jugular vein (EJV) is a low-morbidity alternative for percutaneous catheterization in children, but it has yielded a low success rate in previous reports The authors show an improved success rate with this option. Methods: We performed an analysis of 33 patients` charts in which central venous catheterization using Seldinger technique through the EJV was attempted in 2005. Age, diagnosis, maneuvers used for success, fluoroscopy usefulness, and types of inserted catheters were evaluated. Results: The procedure was successful in 26 (78.8%) patients without complications. Diagnosis was neoplasia in almost half of the patients (42%). In half of the successful cases, body maneuvers were used, namely, twisting the head of the patient to the side of the vein and stretching the ipsilateral arm and shoulder. All but one procedure were completed under fluoroscopic guidance. In 6 (23%) patients, a long-term catheter was inserted. Conclusions: The EJV is an excellent option for central venous catheterization in children. The execution of simple maneuvers along with fluoroscopic assistance might allow for an improved success rate not only for short-term but also for long-term catheter insertion. (C) 2008 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and rapid HPLC assay for determining cefuroxime penetration in the subcutaneous tissue near to surgical incision of patients submitted to coronary artery bypass grafting (CABC) with or without cardiopulmonary bypass (CPB) was performed. Blood and subcutaneous tissue samples were collected from 14 patients. in four periods during surgery. The analytical method presented linearity from 0.5 to 100 mu g/g. LOQ = 0.50 mu g/g, LOD = 0.25 mu g/g. intra- and interday precision (%CV) ranged from 4.9 to 8.9% and 6.4 to 9.9%, respectively, and intra-and interday accuracy expressed as % of the nominal concentration ranged from 87.1 to 104.6% and 94.8 to 103.8%, respectively (mean of three concentrations). Relative recovery was 98.4%. Tissue/plasma ratios obtained for CPB and non-CPB were, respectively: 14.6% vs 19.0% (0.6 h); 15.7% vs 15.7% (2.1 h); 22.5% vs 19.9% (3.6 h); 15.7% vs 18.8% (4.5 h). Data obtained indicate that tissue/plasma ratio remains unchanged in CPB and non-CPB patients during all period of surgery and the CPB does not affect the penetration of cefuroxime in tissues close to the surgical wound. (C) 2009 Elsevier B.V. All rights reserved.