48 resultados para PORTABLE MONITORING
Resumo:
Objective To assess the effect of halothane (H), isoflurane (I) or sevoflurane (S) on the bispectral index (BIS), and the effect of the addition of meperidine in dogs subjected to ovariohysterectomy. Study design Prospective, randomized, blinded, clinical trial. Animals Forty-eight female mixed-breed dogs, with weights varying from 10 to 25 kg. Methods All dogs were premedicated with acepromazine (A) (0.1 mg kg(-1) IM) or A and meperidine (M) (3 mg kg(-1) IM) and they were divided into six groups of eight animals (AH, AMH, AI, AMI, AS, and AMS). Fifteen minutes after premedication they were anesthetized with propofol (5 mg kg(-1) IV) and then orotracheally intubated. Anesthesia was maintained with halothane, isoflurane or sevoflurane, respectively. The BIS, E`(anest) variables were recorded at 15 minutes after administering pre-anesthetic medication (T0); 10 minutes of anesthesia maintenance (T1); right ovarian pedicle ligation (T2); muscle suturing (T3); skin suture (T4) and 10 minutes after terminating the inhalant anesthetic (T5), respectively. Results BIS values were decreased at all times when compared to the baseline values in all groups (p < 0.05). In the comparative assessment between groups, the values obtained at T0 and T1 were similar for all groups. At T2, the values in AMH were lower than those obtained in AI, AMI and AS (p < 0.05). At the same time significantly higher values were found for AI when compared to AMS (p < 0.01). There was a correlation between the bispectral index and the expired anesthetic fraction in all groups. Conclusions and clinical relevance Within groups given the same inhalant anesthetic the bispectral index was a good indicator for the degree of hypnosis in dogs, indicating a good correlation with the amount of anesthetic and the nociceptive stimulation. BIS was a less reliable indicator of relative anesthetic depth when comparing equipotent end-tidal concentrations between the three inhalants.
Resumo:
Our purpose was to evaluate the osteoconduction potential of mixed bovine bone (MBB) xenografts as an alternative for bone grafting of critical-size defects in the calvaria of rats. After surgery, in the time intervals of 1, 3, 6, and 9 months, rats were killed and their skulls collected, radiographed and histologically prepared for analysis. The data obtained from histological analysis reported that the particles of MBB did not promote an intense immunological response, evidencing its biocompatibility in rats. Our results clearly showed the interesting evidence that MBB was not completely reabsorbed at 9 months while a small amount of newly formed bone was deposited by osteoprogenitor cells bordering the defect. However, this discrete bone-forming stimulation was unable to regenerate the bone defect. Overall, our results suggest that the properties of MBB are not suitable for stimulating intense bone regeneration in critical bone defects in rats.
Resumo:
Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.