128 resultados para LIGHT COHERENCE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the effects of Low-intensity Laser Therapy (LILT) and Light Emitting Diode Therapy (LEDT) of low intensity on the treatment of lesioned Achilles tendon of rats. The experimental model consisted of a partial mechanical lesion on the right Achilles tendon deep portion of 90 rats. One hour after the lesion, the injured animals received applications of laser/LED (685, 830/630, 880 nm), and the same procedure was repeated at 24-h intervals, for 10 days. The healing process and deposition of collagen were evaluated based on a polarization microscopy analysis of the alignment and organization of collagen bundles, through the birefringence (optical retardation-OR). The results showed a real efficiency of treatments based on LEDT and confirmed that LILT seems to be effective on healing process. Although absence of coherence of LED light, tendon healing treatment with this feature was satisfactory and can certainly replace treatments based on laser light applications. Applications of infrared laser at 830 nm and LED 880 nm were more efficient when the aim is a good organization, aggregation, and alignment of the collagen bundles on tendon healing. However, more research is needed for a safety and more efficient determination of a protocol with LED.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Light conditions during mycelial growth are known to influence fungi in many ways. The effect of visible-light exposure during mycelial growth was investigated on conidial tolerance to UVB irradiation and wet heat of Metarhizium robertsii, an insect-pathogenic fungus. Two nutrient media and two light regimens were compared. Conidia were produced on (A) potato dextrose agar plus yeast extract medium (PDAY) (A1) under dark conditions or (A2) under continuous visible light (provided by two fluorescent lamps with intensity 5.4 W m-2). For comparison, the fungus was also produced on (B) minimal medium (MM) under continuous-dark incubation, which is known to produce conidia with increased tolerance to heat and UVB radiation. The UVB tolerances of conidia produced on PDAY under continuous visible light were twofold higher than conidia produced on PDAY medium under dark conditions, and this elevated UVB tolerance was similar to that of conidia produced on MM in the dark. The heat tolerance of conidia produced under continuous light was, however, similar to that of conidia produced on MM or PDAY in the dark. Conidial yield on PDAY medium was equivalent when the fungus was grown either under continuous-dark or under continuous-light conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This naphthalene diimide derivative, DC18, forms highly conjugated semiconducting stacked assemblies over electrodes after electrochemical conditioning. These molecular materials are very efficient towards electrochemical photoreduction of oxygen under visible light.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to elucidate electrophysiological and cortical mechanisms involved in anticipatory actions when 23 healthy right-handed subjects had to catch a free falling object by qEEG gamma-band (30-100 Hz). It is involved in cognitive processes, memory, spatial/temporal and proprioceptive factors. Our hypothesis is that an increase in gamma coherence in frontal areas will be observed during moment preceding ball drop, due to their involvement in attention, planning, selection of movements, preparation and voluntary control of action and in central areas during moment after ball drop, due to their involvement in motor preparation, perception and execution of movement. However, through a paired t-test, we found an increase in gamma coherence for F3-F4 electrode pair during moment preceding ball drop and confirmed our hypothesis for C3-C4 electrode pair. We conclude that gamma plays an important role in reflecting binding of several brain areas in a complex motor task as observed in our results. Moreover, for selection of movements, preparation and voluntary control of action, motor preparation, perception and execution of movement, the integration of somatosensory and visual information is mandatory. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Even though porphyria cutanea tarda is the most frequent type of porphyria, there are few studies about its cutaneous physiopathology. OBJECTIVE: To evaluate skin changes in porphyria cutanea tarda using light microscopy and direct immunofluorescence before and after treatment with chloroquine. To perform antigen immunomapping of bullae to study their level of cleavage. METHODS: Light microscopy and direct immunofluorescence of 28 patients are reported in three different phases: 23 patients with active porphyria before treatment (Phase A), 7 patients with clinical remission during treatment (Phase B), and 8 patients with biochemical remission (Phase C). Immunomapping was performed on 7 patients. RESULTS: In active porphyria, direct immunofluorescence showed homogenous and intense fluorescence on the inside and on the walls of blood vessels as well as in the dermal-epidermal junction. In clinical remission (Phase B) and biochemical remission (Phase C), the deposit of immunoglobulins was maintained, but the deposit of complement was reduced in most cases. Immunomapping revealed no standard cleavage plane. CONCLUSION: No correlation was observed between clinical response and immunoglobulin deposits. The reduction of complement favors the hypothesis that activation of the complement cascade represents an additional pathway that leads to endothelial damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three patients with progressive visual loss, chronic alcoholism and tabagism were submitted to a complete neuro-ophthalmic examination and to retinal nerve fiber layer (RNFL) measurements using optical coherence tomography (OCT) scanning. Two patients showed marked RNFL loss in the temporal sector of the optic disc. However, a third patient presented RNFL measurements within or above normal limits, based on the Stratus-OCT normative database. Such findings may be due to possible RNFL edema similar to the one that may occur in the acute phase of toxic optic neuropathies. Stratus-OCT was able to detect RNFL loss in the papillomacular bundle of patients with tobacco-alcohol-induced toxic optic neuropathy. However, interpretation must be careful when OCT does not show abnormality in order to prevent diagnostic confusion, since overestimation of RNFL thickness measurements is possible in such cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the ability of Fourier-domain (FD) optical coherence tomography (3D OCT-1000; Top, con, Tokyo, Japan) and time domain (TD) OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA) to detect axonal loss in eyes with band atrophy (BA) of the optic nerve. DESIGN: Cross-sectional study. METHODS: Thirty-six eyes from 36 patients with BA and temporal visual field (VF) defect from chiasmal compression and 36 normal eyes were studied. Subjects were submitted to standard automated perimetry and macular and retinal nerve fiber layer (RNFL) measurements were taken using 3D OCT-1000 and Stratus OCT. Receiver operating characteristic (ROC) curves were calculated for each parameter. Spearman correlation coefficients were obtained to evaluate the relationship between RNFL and macular thickness parameters and severity of VF loss. Measurements from the two devices were compared. RESULTS: Regardless of OCT device, all RNFL and macular thickness parameters were significantly lower in eyes with BA compared with normal eyes, but no statistically significant difference was found with regard to the area under the ROC curve. Structure-function relationships were also similar for the two devices. In both groups, RNFL and macular thickness measurements were generally and in some cases significantly smaller with 3D OCT-1000 than with Stratus OCT. CONCLUSIONS: The introduction of FD technology did not lead to better discrimination ability for detecting BA of the optic nerve compared with TD technology when using the software currently provided by the manufacturer. 3D OCT-1000 FD OCT RNFL and macular measurements were generally smaller than TD Stratus OCT measurements. Investigators should be aware of this fact when comparing measurements obtained with these two devices. (Am J Oplathalmol 2009;147: 56-63. (c) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson`s correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Associations between systemic lupus erythematosus (SLE) and primary immunodeficiencies (PIDs) were analyzed to gain insight into the physiopathology of SLE. Some PIDs have been consistently associated with SLE or lupus-like manifestations: (a) homozygous deficiencies of the early components of the classical complement pathway in the following decreasing order: in C1q, 93% of affected patients developed SLE; in C4, 75%; in C1r/s, 57%; and in C2, up to 25%; (b) female carriers of X-linked chronic granulomatous disease allele; and (c) IgA deficiency, present in around 5% of juvenile SLE. Discussion In the first two groups, disturbances of cellular waste-disposal have been proposed as the main mechanisms of pathogenesis. On the other hand and very interestingly, there are PIDs systematically associated with several autoimmune manifestations in which SLE has not been described, such as autoimmune polyendocrinopathy candidiasis ectodermal dystrophy (APECED), immunedys-regulation polyendocrinopathy enteropathy X-linked (IPEX), and autoinumme lymphoproliferative syndrome (ALPS), suggesting that mechanisms considered as critical players for induction and maintenance of tolerance to autoantigens, such as (1) AME-mediated thymic negative selection of lymphocytes, (2) Foxp3+ regulatory T cell-mediated peripheral tolerance, and (3) deletion of auto-reactive lymphocytes by Fas-mediated apoptosis, could not be relevant in SLE physiopathology. The non-description of SLE and neither the most characteristic SLE clinical features among patients with agammaglobulinemia are also interesting observations, which reinforce the essential role of B lymphocytes and antibodies for SLE pathogenesis. Conclusion Therefore, monogenic PIDs represent unique and not fully explored human models for unraveling components of the conundrum represented by the physiopathology of SLE, a prototypical polygenic disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To evaluate the effect of disease severity and optic disc size on the diagnostic accuracies of optic nerve head (ONH), retinal nerve fiber layer (RNFL), and macular parameters with RTVue (Optovue, Fremont, CA) spectral domain optical coherence tomography (SDOCT) in glaucoma. METHODS. 110 eyes of 62 normal subjects and 193 eyes of 136 glaucoma patients from the Diagnostic Innovations in Glaucoma Study underwent ONH, RNFL, and macular imaging with RTVue. Severity of glaucoma was based on visual field index (VFI) values from standard automated perimetry. Optic disc size was based on disc area measurement using the Heidelberg Retina Tomograph II (Heidelberg Engineering, Dossenheim, Germany). Influence of disease severity and disc size on the diagnostic accuracy of RTVue was evaluated by receiver operating characteristic (ROC) and logistic regression models. RESULTS. Areas under ROC curve (AUC) of all scanning areas increased (P < 0.05) as disease severity increased. For a VFI value of 99%, indicating early damage, AUCs for rim area, average RNLI thickness, and ganglion cell complex-root mean square were 0.693, 0.799, and 0.779, respectively. For a VFI of 70%, indicating severe damage, corresponding AUCs were 0.828, 0.985, and 0.992, respectively. Optic disc size did not influence the AUCs of any of the SDOCT scanning protocols of RTVue (P > 0.05). Sensitivity of the rim area increased and specificity decreased in large optic discs. CONCLUSIONS. Diagnostic accuracies of RTVue scanning protocols for glaucoma were significantly influenced by disease severity. Sensitivity of the rim area increased in large optic discs at the expense of specificity. (Invest Ophthalmol Vis Sci. 2011;92:1290-1296) DOI:10.1167/iovs.10-5516

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate retinal nerve fiber layer (RNFL), optic nerve head (ONH), and macular thickness measurements for glaucoma detection using the RTVue spectral domain optical coherence tomograph. Design: Diagnostic, case-control study. Participants: One hundred forty eyes of 106 glaucoma patients and 74 eyes of 40 healthy subjects from the Diagnostic Innovations in Glaucoma Study (DIGS). Methods: All patients underwent ocular imaging with the commercially available RTVue. Optic nerve head, RNFL thickness, and macular thickness scans were obtained during the same visit. Receiver operating characteristic (ROC) curves and sensitivities at fixed specificities (80% and 95%) were calculated for each parameter. Main Outcome Measures: Areas under the ROC curves (AUC) and sensitivities at fixed specificities of 80% and 95%. Results: The AUC for the RNFL parameter with best performance, inferior quadrant thickness, was significantly higher than that of the best-performing ONH parameter, inferior rim area (0.884 vs 0.812, respectively; P = 0.04). There was no difference between ROC curve areas of the best RNFL thickness parameters and the best inner macular thickness measurement, ganglion cell complex root mean square (ROC curve area = 0.870). Conclusions: The RTVue RNFL and inner retinal macular thickness measurements had good ability to detect eyes with glaucomatous visual field loss and performed significantly better than ONH parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of the present study was to explore the dynamics of the gamma band using the coherence of the quantitative electroencephalography (qEEG) in a sensorimotor integration task and the influence of the neuromodulator bromazepam on the band behavior. Our hypothesis is that the needs of the typewriting task will demand the coupling of different brain areas, and that the gamma band will promote the binding of information. It is also expected that the neuromodulator will modify this coupling. The sample was composed of 39 healthy subjects. We used a randomized double-blind design and divided subjects into three groups: placebo (n = 13), bromazepam 3 mg (n = 13) and bromazepam 6 mg (n = 13). The two-way ANOVA analysis demonstrated a main effect for the factors condition (i.e., C4-CZ electrode pair) and moment (i.e., C3-CZ, C3-C4 and C4-CZ pairs of electrodes). We propose that the gamma band plays an important role in the binding among several brain areas in complex motor tasks and that each hemisphere is influenced in a different manner by the neuromodulator. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To evaluate the relationship between pattern electroretinogram (PERG) amplitude, macular and retinal nerve fiber layer (RNFL) thickness by optical coherence tomography (OCT), and visual field (VF) loss on standard automated perimetry (SAP) in eyes with temporal hemianopia from chiasmal compression. METHODS. Forty-one eyes from 41 patients with permanent temporal VF defects from chiasmal compression and 41 healthy subjects underwent transient full-field and hemifield (temporal or nasal) stimulation PERG, SAP and time domain-OCT macular and RNFL thickness measurements. Comparisons were made using Student`s t-test. Deviation from normal VF sensitivity for the central 18 of VF was expressed in 1/Lambert units. Correlations between measurements were verified by linear regression analysis. RESULTS. PERG and OCT measurements were significantly lower in eyes with temporal hemianopia than in normal eyes. A significant correlation was found between VF sensitivity loss and fullfield or nasal, but not temporal, hemifield PERG amplitude. Likewise a significant correlation was found between VF sensitivity loss and most OCT parameters. No significant correlation was observed between OCT and PERG parameters, except for nasal hemifield amplitude. A significant correlation was observed between several macular and RNFL thickness parameters. CONCLUSIONS. In patients with chiasmal compression, PERG amplitude and OCT thickness measurements were significant related to VF loss, but not to each other. OCT and PERG quantify neuronal loss differently, but both technologies are useful in understanding structure-function relationship in patients with chiasmal compression. (ClinicalTrials.gov number, NCT00553761.) (Invest Ophthalmol Vis Sci. 2009; 50: 3535-3541) DOI:10.1167/iovs.08-3093

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Models of warped extra dimensions with custodial symmetry usually predict the existence of a light Kaluza-Klein fermion arising as a partner of the right-handed top quark, sometimes called light custodians which we will denote (b) over tilde (R). The production of these particles at the LHC can give rise to multi-W events which could be observed in same-sign dilepton channels, but its mass reconstruction is challenging. In this paper we study the possibility of finding a signal for the pair production of this new particle at the LHC focusing on a rarer, but cleaner decay mode of a light custodian into a Z boson and a b-quark. In this mode it would be possible to reconstruct the light custodian mass. In addition to the dominant standard model QCD production processes, we include the contribution of a Kaluza-Klein gluon first mode. We find that (b) over tilde (R) stands out from the background as a peak in the bZ invariant mass. However, when taking into account only the electronic and muonic decay modes of the Z boson and b-tagging efficiencies, the LHC will have access only to the very light range of masses, m((b) over tilde) = O(500) GeV.