72 resultados para Base Bending Sign Posts.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acidosis is a common and deleterious aspect of maintenance dialysis. Traditionally, it is considered to be an elevated anion gap acidosis caused by the inability to excrete nonvolatile anions. Stewart`s approach made it possible to identify real determinants of the acid-base status and allowed quantification of the components of these disturbances, especially the unmeasured anions. We performed a cross-sectional study to identify and quantify each component of acidosis in hemodialysis maintenance patients. Sixty-four maintenance hemodialysis patients and 14 controls were enrolled in this study. Gasometrical and biochemical analysis were performed before the midweek dialysis session. Quantitative physicochemical analysis was carried out using the Stewart methodology. Hemodialysis patients were found to have mild acidemia (mean pH: 7.33 +/- 0.06 versus 7.41 +/- 0.05) secondary to metabolic acidosis (serum bicarbonate: 18.8 +/- 0.26 versus 25.2 +/- 0.48 mEq/l). The metabolic acidosis was due to retention of unmeasured anions (6.5 +/- 0.29 versus 3.1 +/- 0.62 mEq/l), hyperchloremia (105.1 +/- 0.5 versus 101.8 +/- 0.7 mEq/l), and hyperphosphatemia (5.90 +/- 0.19 versus 3.66 +/- 0.14 mg/dl). Compared with control values, the unmeasured anions and hyperchloremia had a similar acidifying effect (3.4 and 3.3 mEq/l), corresponding to almost 90% of the metabolic acidosis. Unmeasured anions and hyperchloremia are important components of acidosis in maintenance hemodialysis, in addition to phosphorus. Future studies to determine the etiology and consequences of hyperchloremic acidosis are warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare SEMG activities during axial load exercises on a stable base of support and on a medicine ball (relatively unstable). Twelve healthy male volunteers were tested (x = 23 +/- 7y). Surface EMG was recorded from the biceps brachii, anterior deltoid, clavicular portion of pectoralis major, upper trapezius and serratus anterior using surface differential electrodes. All SEMG data are reported as percentage of RMS mean values obtained in maximal voluntary contractions for each muscle studied. A 3-way within factor repeated measures analysis of variance was performed to compare RMS normalized values. The RMS normalized values of the deltoid were always greater during the exercises performed on a medicine ball in relation to those performed on a stable base of support. The trapezius showed greater mean electric activation amplitude values on the wall-press exercise on a medicine ball, and the pectoralis major on the push-up. The serratus and biceps did not show significant differences of electric activation amplitude in relation to both tested bases of support. Independent of the base of support, none of the studied muscles showed significant differences of electric activation amplitude during the bench-press exercise. The results contribute to the identification of the levels of muscular activation amplitude during exercises that are common in clinical practice of rehabilitation of the shoulder and the differences in terms of type of base of support used. (C) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Premature closure of the proximal femoral growth plate results in coxa brevis, which usually is associated with insufficiency of the hip abductors. Distal and lateral transfer of the greater trochanter sometimes is recommended to correct this problem. Most of what is known arises from studies of children and adolescents. We asked whether this procedure in adults with coxa brevis would eliminate hip abductor insufficiency and would improve their hip function based on the Harris hip score (HHS). We prospectively followed 11 patients, aged 19 to 55 years (mean, 40 years) who had distal and lateral trochanteric transfer. All patients had pain and a positive Trendelenburg test before surgery. This test was performed at the latest followup by three observers and the interobserver reliability was determined by the kappa coefficient. The HHS was obtained before surgery and at the latest followup. The minimum followup was 25 months (mean, 52 months; range, 25-77 months). Insufficiency of the hip abductors was eliminated in seven (according to two observers) and eight (according to one observer) of the 11 patients after surgery; the kappa coefficient ranged from 0.79 to 1.0. The mean HHS improved from 64 points preoperatively to 76 points at the final followup. The two patients with preexisting severe osteoarthritis of the hip had the worst final scores and persisted with a positive Trendelenburg test at the final followup. Distal and lateral transfer of the greater trochanter can eliminate insufficiency of the hip abductors and improve joint function in adult patients with coxa brevis and we believe should be considered for patients without severe osteoarthritis of the hip. Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated four polymorphisms located in the DC-SIGN (CD209) gene promoter region (positions -336, -332 -201 and -139) in DNA samples from four Brazilian ethnic groups (Caucasians, Afro-Brazilian, Asians and Amerindians) to establish the population distribution of these single-nucleotide polymorphisms (SNPs) and correlated DC-SIGN polymorphisms and infection in samples from human T-cell lymphotropic virus type 1 (HTLV-1)-infected individuals. To identify CD209 SNPs, 452 bp of the CD209 promoter region were sequenced and the genotype and allelic frequencies were evaluated. This is the first study to show genetic polymorphism in the CD209 gene in distinct Brazilian ethnic groups with the distribution of allelic and genotypic frequency. The results showed that -336A and -139A SNPs were quite common in Asians and that the -201T allele was not observed in Caucasians, Asians or Amerindians. No significant differences were observed between individuals with HTLV-1 disease and asymptomatic patients. However, the -336A variant was more frequent in HTLV-1 -infected patients [HTLV-1-associated myelopathy/tropical spastic paraparesis (HAM/TSP), 80%; healthy asymptomatic HTLV-1 carriers, 90 %] than in the control group (70 %) [P=0.0197, odds ratio (OR)=2.511, 95 % confidence interval (CI)=1.218-5.179). In addition, the -139A allele was found to be associated with protection against HTLV-1 infection (P=0.0037, OR=0.3758, 95% CI=0.1954-0.7229) when the HTLV-1 -infected patients as a whole were compared with the healthy-control group. These observations suggest that the -139A allele may be associated with HTLV-1 infection, although no significant association was observed among asymptomatic and HAM/TSP patients. In conclusion, the variation observed in SNPs -336 and -139 indicates that this lectin may be of crucial importance in the susceptibility/transmission of HTLV-1 infections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adjustments during postural control have been recognized in the process of the integration of movement and cognition. The objective of the present work was to describe postural changes and to verify if there is a correlation between postural adjustment and attention span in 7-month-old infants during 1 min of viewing an animated puppet. Method: Twenty-nine healthy infants (14 males) born from 31 to 39 weeks (median 36) were placed in a prone position and filmed watching a puppet during I min. The analysis of the images allowed us to catalogue the changes in position, the frequency of these changes, and the attention span. The following items were quantified: total number of infant positions, positions with weight transfer, changes in support, axis, decubitus, trunk and cervical movements, timing and pauses in visual attention. Results: Twenty-one infants stayed in the prone position during most of the recording, and eight chose sitting position before starting the session. Two groups were studied according to the main position throughout the filming, one in prone and the other in sitting positions, although they could rolling or crawling. For prone group the attention span was positively correlated with the number of positions with weight transfer (r = 0.53, p = 0.04), negatively correlated with trunk movements (r = -0.63, p = 0.01), and not correlated with birth or current weight. This work suggests that changes in the trunk movements and weight transfer are different traits related to the attention in 7-month-old infants. (C) 2008 Elsevier B.V.. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives Posterior urethral valves (PUV) are the most common cause of renal impairment in boys during early childhood. Although antenatal suspicion of this pathology has become quite common in recent years, prenatal diagnosis remains challenging. The aim of this study was to evaluate the predictive value of different ultrasound criteria currently used to diagnose PUV. Methods We reviewed the antenatal and postnatal files of 54 male patients referred to our center from 2000 to 2006 after detection of fetal bilateral hydronephrosis. The following ultrasound criteria were evaluated in relation to the postnatal diagnosis of P U V: amniotic fluid volume, bladder wall thickness, bladder dilatation and the presence of the `keyhole sign`. Results Forty-two fetuses (77.8%) were suspected to have PUV on prenatal examination. Out of these, 29 (69.0%) had PUV confirmed postnatally. The sensitivity and specificity of the antenatal diagnosis of PUV were 94% and 43%, respectively. Increased bladder wall thickness and bladder dilatation were highly associated with the diagnosis of PUV (P < 0.001). However, a thick-walled bladder was observed in 39.1% and a dilated bladder in 47.8% of the infants with a postnatal diagnosis other than PUV. The presence of the keyhole sign was not found to predict a diagnosis of PUV (P = 0.27). Conclusion In this series the use of classical prenatal ultrasound signs to diagnose PUV showed high sensitivity but low specificity. The best diagnostic indicators were increased bladder wall thickness and dilatation of the bladder. The keyhole sign was not found to be a reliable predictor of PUV. Copyright (C) 2009 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are limited data concerning blood gas parameters in neonatal dogs. Knowledge of the normal physiology may facilitate effective therapeutic intervention and potentially reduce neonatal mortality. This study examined acid-base parameters in pups born at normal parturition (n = 27) compared with those born after obstetrical assistance or caesarean operation (n = 13) and those born following oxytocin (OXY) administration for treatment of uterine inertia (n = 11). Pups were subjected to an objective scoring method of neonatal health adapted from use in humans (the Apgar score) at birth and again at 5 and 60 min after birth. Venous blood samples were collected at 5 and 60 min after birth for evaluation of blood gas parameters. At birth, all pups had low Apgar scores and a mixed acidosis. The base excess was lowest for pups delivered after OXY administration. The Apgar score improved for all pups after 5 min of birth and there was an improvement in carbon dioxide tension, base excess and venous blood pH at 1 h, although in all pups a metabolic acidosis persisted. These data provide an important insight into neonatal physiology and the variability of blood gas parameters in pups born at normal and abnormal parturition and provide the basis for clinical decision making following dystocia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. Stress development at the tooth/restoration interface is one of the most important reasons for failure of adhesive restorations. The aim of this study was to evaluate the influence of BisGMA/TEGDMA (B/T) and UDMA/TEGDMA (U/T) ratios on polymerization stress (PS) and on the variables related to its development: degree of conversion (DC), polymerization maximum rate (Rp(max)), volumetric shrinkage (VS), elastic modulus (E), stress relaxation (SR) and viscosity of experimental composites. Method. Composites were formulated containing B/T or U/T in mol% ratios of 2: 8, 3: 7, 4: 6, 5: 5, 6: 4, 7: 3 and 8: 2, and 15 wt% of fumed silica. PS was determined with a universal testing machine. VS was measured with a linometer. E and SR were obtained in three-point bending. DC and Rp(max) were determined by real time NIR spectroscopy and viscosity was measured in viscometer. Data were submitted to one-way ANOVA, Tukey test (alpha = 0.05%) and regression analyses. Results. PS, VS, E and DC decreased and viscosity and Rp(max) increased with base monomer content in both series. PS showed strong correlation with VS, DC and viscosity. PS, VS and DC were higher and viscosity was lower for UDMA-based materials. Significance. Reduced viscosity, kinetics parameters and molecular characteristics led UDMA-based composites to elevated conversion and relatively lower PS at lower TEGDMA contents, compared to B/T composites. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical success of fiber posts has been attributed to their lower elastic modulus. The tested hypothesis was that fiber posts could lead to lower risk of post debonding and lower risk of root fracture, despite an increase in root stresses. Stress analyses were carried out with a 3D finite element model of a premolar restored with a metallic or a fiber post. Bonded and non-bonded post/cement interface conditions were simulated. We calculated risk-of-fracture indices by determining the highest principal stress values divided by the tensile strength. Shear stresses along the post/cement interface were analyzed for the bonded models. Compared with the premolar restored with a metallic post, the fiber post generated lower stresses along the interface and higher stresses in the root. However, with the fiber post, fracture was less likely to occur in the root, since its core and post fracture indices were higher.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The definition of an optimal elastic modulus for a post is controversial. This work hypothesized that the influence of the posts` elastic modulus on dentin stress concentration is dependent on the load direction. The objective was to evaluate, using finite element analysis, the maximum principal stress (sigma(max)) on the root, using posts with different elastic modulus submitted to different loading directions. Nine 3D models were built, representing the dentin root, gutta-percha, a conical post and the cortical bone. The softwares used were: MSC.PATRAN2005r2 (preprocessing) and MSC.Marc2005r2 (processing). Load of 100 N was applied, varying the directions (0 degrees, 45 degrees and 90 degrees) in relation to the post`s long axis. The magnitude and direction of the sigma(max) were recorded. At the 45 degrees and 90 degrees loading, the highest values of sigma(max) were recorded for the lowest modulus posts, on the cervical region, with a direction that suggests debonding of the post. For the 0 degrees loading, the highest values of sigma(max) were recorded for higher modulus posts, on the apical region, and the circumferential direction suggests vertical root fracture. The hypothesis was accepted: the effect of the elastic modulus on the magnitude and direction of the sigma(max) generated on the root was dependent on the loading direction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Upper premolars restored with endodontic posts present a high incidence of vertical root fracture (VRF). Two hypotheses were tested: (1) the smaller mesiodistal diameter favors stress concentration in the root and (2) the lack of an effective bonding between root and post increases the risk of VRF. Using finite element analysis, maximum principal stress was analyzed in 3-dimensional intact upper second premolar models. From the intact models, new models were built including endodontic posts of different elastic modulus (E = 37 or E = 200 GPa) with circular or oval cross-section, either bonded or nonbonded to circular or oval cross-section root canals. The first hypothesis was partially confirmed because the conditions involving nonbonded, low-modulus posts showed lower tensile stress for oval canals compared to circular canals. Tensile stress peaks for the nonbonded models were approximately three times higher than for the bonded or intact models, therefore confirming the second hypothesis. (J Endod 2009;35:117-120)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To test the null hypothesis that continuity of resin cement/dentin interfaces is not affected by location along the root canal walls or water storage for 3 months when bonding fiber posts into root canals. Methods. Fiber posts were luted to bovine incisors using four resinous luting systems: Multilink, Variolink II, Enforce Dual and Enforce PV. After cementation, roots were longitudinally sectioned and epoxy resin replicas were prepared for SEM analysis (baseline). The original halves were immersed in solvent, replicated and evaluated. After 3 months water storage and a second solvent immersion, a new set of replicas were made and analyzed. The ratio (%) between the length (mm) of available bonding interface and the actual extension of bonded cement/dentin interface was calculated. Results. Significant lower percent values of bond integrity were found for Multilink (8.25%) and Variolink 11 (10.08%) when compared to Enforce Dual (25.11%) and Enforce PV (27.0%) at baseline analysis. The same trend was observed after immersion in solvent, with no significant changes. However, bond integrity was significantly reduced after 3 months water storage and a second solvent immersion to values below 5% (Multilink = 3.31%, Variolink=1.87%, Enforce Dual=1.20%, and Enforce PV=0.75%). The majority of gaps were depicted at the apical and middle thirds at baseline and after immersion in solvent. After 3 months, gaps were also detected at the cervical third. Significance. Bond integrity at the cement/dentin interface was surprisingly low after cementation of fiber posts to root canals with all resin cements. That was not significantly altered after immersion in solvent, but was further compromised after 3 months water storage. Gaps were mainly seen at middle and apical thirds throughout the experiment and extended to the cervical third after water storage for 3 months. Bond integrity of fiber posts luted to root canals was affected both by location and water storage. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effects of storage condition and duration on the resistance to fracture of different fiber post systems (and to morphologically assess the post structure before and after storage. Methods: Three types of fiber posts (DT Light Post, GC Post, FRC Postect Plus) were divided in different groups (n=12) according to the storage condition (dry at 37 degrees C; saline water at 37 degrees C; mineral oil at 37 degrees C and storage inside the roots of extracted human teeth immersed in saline water at 37 degrees C and duration (6, 12 months). A universal testing machine loading at a 90 degrees angle was employed for the three-point bending test. The test was carried out until fracture of the post. A 3-way ANOVA and Tukey`s test (alpha= 0.05) were used to compare the effect of the experimental factors on the fracture strength. Two posts of each group were observed before and after the storage using a scanning electron microscope. Results: Storage condition and post type had a significant effect on post fracture strength (P< 0.05). The interaction between these factors was significant (P< 0.05). Water storage significantly decreased the fracture strength, regardless of the post type and the storage duration. Storage inside roots, in oil, and at dry conditions did not significantly affect post fracture strength. SEM micrographs revealed voids between fibers and resin matrix for posts stored in water. Posts stored under the other conditions showed a compact matrix without porosities. (Am J Dent 2009;22:366-370).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the cement thickness around oval and circular posts luted in oval post spaces prepared with different drills/tips. Methods: Extracted premolars were endodontically treated and obturated, then randomly divided into three groups (n = 5) according to the tips/drills used for post-space preparation and to the type of fiber post luted: medium grit oval tip + oval posts, fine grit oval tip + oval posts, Mtwo Post File drill + circular posts. The specimens were sectioned in horizontal slices; one slice per canal third was chosen for each post-space, resulting in three slices for each specimen. The distances between the canal wall and the post perimeter were measured on SEM images of each slice. Results: The fine grit tip + oval post group obtained statistically significant lower cement thicknesses than the other groups (P < 0.05), in particular in the apical third. The MtwoPF + circular post group showed the highest cement thickness, comparable to that of the medium tip + oval post group. A good post fitting in oval-shaped canals can be obtained using a fine grit oval tip combined with oval posts. (Am J Dent 2009;22:290-294).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The study evaluates the behavior of different adhesive systems and resin cements in fiber post placement, with the intent to clarify the possible role of unfilled resin as a luting material for fiber posts. Materials and Methods: Two luting agents (Dual-Link and Unfilled Resin) for cementing fiber posts into root canals were applied either with All-Bond 2 or One-Step Plus, or without an adhesive system, and challenged with the push-out test. Slices of roots restored with posts were loaded until post segment extrusion in the apical-coronal direction. Failure modes were analyzed under SEM. Results: Push-out strength was significantly influenced by the luting agent (p < 0.05), but not by the bonding strategy (p > 0.05). The best results were obtained in combination with Unfilled Resin with One-Step Plus. Dual-Link groups failed mainly cohesively within the cement, while Unfilled Resin demonstrated more adhesive fracture at the post interface. Conclusion: The results of this study support the hypothesis that adhesive unfilled resin application is essential for achieving high bond strength to radicular dentin.