234 resultados para theoretic limit
Resumo:
Este artigo evidencia análises contidas na dissertação cujo objetivo foi analisar os discursos dos operadores jurídico-sociais em processos judiciais de Varas da Infância e Juventude de duas cidades brasileiras. Os direitos das crianças e adolescentes, a questão social e a análise do discurso configuraram-se como referenciais teóricos e de análise. Resultados evidenciaram discursos de proteção e revelaram também a intenção de punição. A questão social foi ignorada pelos operadores a despeito dos contextos em que ocorreram as infrações.
Resumo:
The possibility of using a graphite silicone-rubber composite electrode (GSR) in a differential pulse voltammetric(DPV) procedure for rutin (vitamin P) determination is described. Cyclic voltammograms of rutin presented a reversible pair of oxidation/reduction peaks respectively at 0.411 and 0.390 V (vs. SCE) at the GSR surface in Britton-Robinson(B-R) buffer solution pH 4.0. In DPV after optimization of conditions, an oxidation peak at 0.370 V (vs. SCE) was used to quantitative determination of rutin in B-R buffer solution pH 4.0. In this case a linear dynamic range of 5.0×10-8 to 50.0×10-8 mol L-1 was observed with a detection limit of 1.8×10-8 mol L-1 for the analyte. Recoveries from 94 to 113% were observed. The electrode surface was renewed by polishing after each determination, with a repeatability of 1.09 ± 0.06 µA (n = 10) peak current. Rutin was determined in a pharmaceutical formulation using the proposed electrode and the results agreed with those from an official method within 95% confidence level.
Resumo:
This work describes the construction and testing of a simple pressurized solvent extraction (PSE) system. A mixture of acetone:water (80:20), 80 ºC and 103.5 bar, was used to extract two herbicides (Diuron and Bromacil) from a sample of polluted soil, followed by identification and quantification by high-performance liquid chromatography coupled with diode array detector (HPLC-DAD). The system was also used to extract soybean oil (70 ºC and 69 bar) using pentane. The extracted oil was weighed and characterized through the fatty acid methyl ester analysis (myristic (< 0.3%), palmitic (16.3%), stearic (2.8%), oleic (24.5%), linoleic (46.3%), linolenic (9.6%), araquidic (0.3%), gadoleic (< 0.3%), and behenic (0.3%) acids) using high-resolution gas chromatography with flame ionization detection (HRGC-FID). PSE results were compared with those obtained using classical procedures: Soxhlet extraction for the soybean oil and solid-liquid extraction followed by solid-phase extraction (SLE-SPE) for the herbicides. The results showed: 21.25 ± 0.36% (m/m) of oil in the soybeans using the PSE system and 21.55 ± 0.65% (m/m) using the soxhlet extraction system; extraction efficiency (recovery) of herbicides Diuron and Bromacil of 88.7 ± 4.5% and 106.6 ± 8.1%, respectively, using the PSE system, and 96.8 ± 1.0% and 94.2 ± 3.9%, respectively, with the SLP-SPE system; limit of detection (LOD) and limit of quantification (LOQ) for Diuron of 0.012 mg kg-1 and 0.040 mg kg-1, respectively; LOD and LOQ for Bromacil of 0.025 mg kg-1 and 0.083 mg kg-1, respectively. The linearity used ranged from 0.04 to 1.50 mg L-1 for Diuron and from 0.08 to 1.50 mg L-1 for Bromacil. In conclusion, using the PSE system, due to high pressure and temperature, it is possible to make efficient, fast extractions with reduced solvent consumption in an inert atmosphere, which prevents sample and analyte decomposition.
Resumo:
The potentiality of the use of ultrasound radiation in association with a boron-doped diamond electrode was evaluated on the voltammetric determination of the pesticide carbaryl. Improvements in the sensitivity, limit of detection and reproducibility of the measurements were observed due to both, the enhancement of mass transport and the cleaning of the electrode surface provided by ultrasound. Satisfactory recovery levels for carbaryl in pure water (96-98%) and pineapple juice (89-92%) for quiescent and sonovoltammetric methodologies were obtained. These methodologies can be alternative tools for the analyses of pesticides in fruit samples, mainly the insonated condition that improve the analytical performance and dispense intermediary cleanings of the electrode surface.
Resumo:
In Brazil, Hypnea musciformis is the main raw material for carrageenan production and the knowledge of nitrogen and phosphorus metabolism in algae is critical for the success of cultivation because these elements can limit seaweed productivity. Thus, the objective of this study was to evaluate the effects of nitrate (zero to 100 μM) and nitrate plus phosphate (zero to 25 μM) availabilities on the growth, the contents of photosynthetic pigments (phycobiliproteins and chlorophyll a) and proteins, and the photosynthesis and respiration of the brown (BR) and light green (LG) strains of H. musciformis. The results revealed metabolic differences between the colour strains of H. musciformis for nitrogen metabolism: upon nitrate addition, the LG strain stored nitrogen mainly as proteins, while the BR strain stored it as proteins and pigments. Moreover, the respiration of the LG strain and the photosynthesis of the BR strain increased with nitrate concentrations, indicating that the BR strain fixed more photosynthetic carbon than the LG strain.
Resumo:
Secondary alcohol concentrations in sugar cane spirits from different origins were determined by gas chromatography. A great variation in the concentration of the secondary alcohols was found in these spirits. Of the 33 brands analyzed, 8 of them were found to be out of conformity with the legislation. Sec butanol, for which the maximum allowed concentration level is 100 mg.L-1 in absolute ethanol, was found within a concentration range between 5 mg.L-1, the limit of quantitation (LQ) and 408 mg.L-1 in absolute ethanol. Sugar cane samples from Salinas, MG, were the only ones that exhibited self similarity because of the low concentrations of n-butanol and n-amylic alcohol (< limit of detection LD).
Resumo:
The electrochemical behavior of fluconazole showed an irreversible oxidation process, with the electrochemical - chemical mechanism being highly dependent on the electrode material. Adsorption of reagent at positive applied potential was observed at Pt electrode while preferential adsorption of the oxidation products was observed at Glassy Carbon surfaces. In pH below 7.0, the anodic current process was intensively decreased. At carbon paste electrode, the fluconazole oxidation current, recorded in phosphate buffer solution (pH 8.0), changed linearly with the fluconazole concentration, Ipa = 5.7×10-5 (mA) × 0.052 [Fluconazol] (μg mL-1), in the range of 48.0 to 250.0 μg mL-1. The detection limit obtained was 6.3 μg mL-1.
Resumo:
An amperometric lactate biosensor with lactate oxidase immobilized into a Prussian Blue (PB) modified electrode was fabricated. The advantage of using cetyltrimethylammonium bromide (CTAB) in the electrodeposition step of PB films onto glassy carbon surfaces was confirmed taking into account both the stability and sensitivity of the measurements. The biosensor was used in the development of a FIA amperometric method for the determination of lactate. Under optimal operating conditions (pH = 6.9, E = -0.1 V), the linear response of the method was extended up to 0.28 µmol L-1 lactate with a limit of detection of 0.84 mmol L-1. The repeatability of the method for injections of a 0.28 mmol L-1 lactate solution was 2.2 % (n = 18). The usefulness of the method was demonstrated by determining lactate in beer samples and the results were in good agreement with those obtained by using a reference spectrophotometric enzyme method.
Resumo:
Solid-phase microextraction, using on-line bis(trimethylsilyl)trifluoroacetamide derivatisation, gas chromatography, and mass spectrometry, was evaluated in the quantification of 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX) in water samples. Fibres encompassing a wide range of polarities were used with headspace and direct immersion sampling. For the immersion procedure, various parameters affecting MX extraction, including pH, salinity, temperature, and extraction time were evaluated. The optimised method (polyacrylate fibre; 20% Na2SO4; pH 2.0; 60 min; 20 °C) was applied for reservoir chlorinated water samples-either natural or spiked with MX (50 ng L-1 and 100 ng L-1). The recovery of MX ranged from 44 to 72%. Quantification of MX in water samples was done using external standard and the selected ion monitoring mode. Correlation coefficient (0.98%), relative standard deviation (5%), limit of detection (30 ng L-1) and limit of quantification (50 ng L-1) were obtained from calibration curve.
Resumo:
Atherinella blackburni is a silverside species whose occurrence on the Brazilian coast was not properly registered until recently. So far, records of its distribution along the Brazilian shore were limited to Itaparica Island, Bahia State, and Porto Inhaúma, Rio de Janeiro State. In a recent survey of the ichthyofauna of Itamambuca Beach, Ubatuba, São Paulo State, 100 specimens of this species were collected, yielding a considerable source of information regarding its ecology and a new southern limit of its distribution. A detailed survey of an ichthyological collection revealed lots of this species from regions of the Brazilian Northeast, resulting in a northward expansion of the occurrence of A. blackburni in Brazilian waters. Besides the populations found on the Brazilian coast, the species also occurs discontinuously in the Atlantic coasts of Costa Rica, Panama and Venezuela. Meristic and morphometric analysis showed overlapped values between Brazilian populations and the ones closer to the Caribbean. An ecological study of A. blackburni at Itamambuca Beach revealed that it is a predominantly diurnal species with preference for warm and salty waters, often occurring in sandy-bottom environments. It was more abundant in Summer and Winter, when individuals with smaller values of length and weight also occurred.
Resumo:
This systematic review addressed cohort studies on obesity in childhood and adolescence and adult mortality, published from January 1990 to March 2007. We searched the PubMed database with the following uniterms: obesity, mortality, child, adolescent; obesity and mortality; overweight and mortality. References were also analyzed. The age limit was 2 to 18 years. Quality of the articles was assessed, and eight were identified and reviewed. All used weight and stature for determination of obesity, and seven used body mass index (BMI). The quality score varied from 9 to 17. Evidence of association between obesity in childhood and adolescence and adult mortality should be viewed with caution. Use of BMI and potential confounders were discussed. Further research is needed to analyze the relationship between childhood and adolescent obesity and adult mortality.
Resumo:
A distrofia muscular de Duchenne (DMD) é uma alteração neuromuscular caracterizada por contínua necrose muscular e degeneração, com eventual fibrose e infiltração por tecido adiposo. O aumento progressivo da fibrose intersticial no músculo impede a migração das células miogênicas, necessárias para a formação muscular. O modelo canino constitui-se nas melhores fenocópias da doença em humanos, quando comparados com outros modelos animais com distrofia. O tratamento antifibrose de pacientes DMD, tendo como alvo os mediadores da citocina, TGF-beta, e o tratamento com antiinflamatórios, podem limitar a degeneração muscular e contribuir para a melhora do curso da doença. O presente estudo teve como objetivo observar os possíveis efeitos adversos na fisiologia renal, por meio de avaliação bioquímica sanguínea e da pressão arterial, verificando a viabilidade do uso do Losartan (um inibidor de TGF-beta) nos cães afetados pela distrofia muscular. Foram utilizados quatro cães adultos, sendo dois machos e duas fêmeas. Utilizou-se a dose de 50mg de Losartan, administrada via oral, uma vez ao dia. Os exames clínicos, bem como alterações na função renal, o nível do potássio sérico e a pressão arterial não evidenciaram reação adversa durante todo o período do experimento. O uso de Losartan, por um período de 9 semanas, mostrou-se como uma terapia segura para o tratamento antifibrótico em cães adultos, não afetando a função renal ou pressão arterial dos animais.
Resumo:
It was evaluated the effects of levels of digestible lysine and chelate zinc combined in the diet for laying on the egg quality. It was used 720 birds, from 48 to 60 weeks of age, distributed in a completely randomized design in a 3 × 5 factorial scheme with three levels of zinc and five levels of lysine, applied into six replicates in the experimental units of eight birds per plot. The levels were: 137, 309 and 655 ppm zinc and 0.482, 0.527, 0.582, 0.644 and 0.732% digestible lysine. It was not observed any interaction among digestible lysine and zinc for the primary variables of fractions and egg composition. Levels of zinc reduced egg weight, suggesting the lowest efficiency in nutrient intake. At the highest dietary concentration of zinc, the addition of digestible lysine coincided with a linear increase in shell weight. However, zinc addition, regardless of lysine level in the diet, resulted in the reduction of egg weight and of the percentage of mineral matter in the yolk, limiting the efficiency of mineral deposition in this fraction of the egg. Concentration of zinc that produced the best results was 137 ppm inasmuch as higher quantities limit the use of digestible lysine, with effects harming composition and egg quality. The study indicates the following requirement for digestible lysine: 0.639% from the 48th to the 52nd week, 0.679% from the 52nd to 56th week, and 0.635% from the 56th to the 60th week. Considering the total period from 48th to the 60th week, the level 0.638% of lysine or the daily intake of 707 mg of the amino acid met the requirement for egg quality of semi-heavy layers used in this study.
Resumo:
OBJETIVO: Estimar o efeito da taxa de cobertura de linhas telefônicas residenciais em potenciais vícios de informação em inquéritos epidemiológicos. MÉTODOS: Foram utilizadas as bases de dados da Pesquisa Nacional por Amostra de Domicílios no período de 1998 a 2003 para a estimativa das taxas de cobertura de linhas telefônicas residenciais nas cinco regiões geográficas brasileiras. Utilizou-se a regressão logística múltipla para identificar os fatores associados à posse de linha telefônica fixa. O impacto do vício nos intervalos com 95% de confiança foi avaliado em função da precisão alcançada em cada situação. RESULTADOS: Nas regiões metropolitanas Sudeste, Sul e Centro-Oeste com 70% e mais de cobertura, os vícios associados foram considerados desprezíveis. Nas demais regiões, os vícios relativos estavam acima do limite aceitável (0,4), indicando possíveis erros nas inferências construídas sob intervalo com 95% de confiança. A chance de acesso à linha telefônica residencial foi maior para população com cor da pele branca e maior escolaridade. CONCLUSÕES: Os achados mostram que o uso de cadastro de linhas telefônicas residenciais é indicado para a realização de inquéritos epidemiológicos apenas para estados com cobertura acima de 70%. Metodologias específicas para o tratamento de estimativas obtidas em localidades com taxas inferiores, precisam ser estudadas e divulgadas
Resumo:
A photometric procedure for the determination of ClO(-) in tap water employing a miniaturized multicommuted flow analysis setup and an LED-based photometer is described. The analytical procedure was implemented using leucocrystal violet (LCV; 4,4', 4 ''-methylidynetris (N, N-dimethylaniline), C(25)H(31)N(3)) as a chromogenic reagent. Solenoid micropumps employed for solutions propelling were assembled together with the photometer in order to compose a compact unit of small dimensions. After control variables optimization, the system was applied for the determination of ClO(-) in samples of tap water, and aiming accuracy assessment samples were also analyzed using an independent method. Applying the paired t-test between results obtained using both methods, no significant difference at the 95% confidence level was observed. Other useful features include low reagent consumption, 2.4 mu g of LCV per determination, a linear response ranging from 0.02 up to 2.0 mg L(-1) ClO(-), a relative standard deviation of 1.0% (n = 11) for samples containing 0.2 mg L(-1) ClO(-), a detection limit of 6.0 mu g L(-1) ClO(-), a sampling throughput of 84 determinations per hour, and a waste generation of 432 mu L per determination.