56 resultados para metallic truck-tier


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cellulose acetate polymeric membranes had been prepared by a procedure of two steps, combining the method of phase inversion and the technique of hydrolysis-deposition. The first step was the preparation of the membrane, and together was organomodified with tetraethylortosilicate and 3-aminopropyltrietoxysilane. Parameters that exert influence in the complexation of the metallic ion, as pH, time of complexation, metal concentration, had been studied in laboratory using tests of metal removal. The membranes had presented resistance mechanics and reactivity to cations, being able to be an alternative for the removal, daily pay-concentration or in the study of the lability of metals complexed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this communication we describe the application of a conductive polymer gas sensor as an air pressure sensor. The device consists of a thin doped poly(4'-hexyloxy-2,5-biphenylene ethylene) (PHBPE) film deposited on an interdigitated metallic electrode. The sensor is cheap, easy to fabricate, lasts for several months, and is suitable for measuring air pressures in the range between 100 and 700 mmHg.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new tetraruthenated copper(II)-tetra(3,4-pyridyl)porphyrazine species, [CuTRPyPz]4+, has been synthesized and fully characterized by means of analytical, spectroscopic and electrochemical techniques. This À-conjugated system contrasts with the related meso-tetrapyridylporphyrins by exhibiting strong electronic interaction between the coordinated peripheral complexes and the central ring. Based on favorable À-stacking and electrostatic interactions, layer-by-layer assembled films were successfully generated from the appropriate combination of [CuTRPyPz]4+ with copper(II)-tetrasulfonated phtalocyanine, [CuTSPc]4-. Their conducting and electrocatalytic properties were investigated by means of impedance spectroscopy and rotating disc voltammetry, exhibiting metallic behavior near the Ru(III/II) redox potential, as well as enhanced catalytic activity for the oxidation of nitrite and sulphite ions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the infrared spectroscopy characterization and the charge compensation dynamics in supramolecular film FeTPPZFeCN derived from tetra-2-pyridyl-1,4-pyrazine (TPPZ) with hexacyanoferrate, as well as the hybrid film formed by FeTPPZFeCN and polypyrrole (PPy). For supramolecular film, it was found that anion flux is greater in a K+ containing solution than in Li+ solution, which seems to be due to the larger crystalline ionic radius of K+. The electroneutralization process is discussed in terms of electrostatic interactions between cations and metallic centers in the hosting matrix. The nature of the charge compensation process differs from others modified electrodes based on Prussian blue films, where only cations such as K+ participate in the electroneutralization process. In the case of FeTPPZFeCN/PPy hybrid film, the magnitude of the anions’s flux is also dependent on the identity of the anion of the supporting electrolyte.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Three approaches were applied to evaluate metal contamination in 41 sediment samples from the Santos - São Vicente Estuarine System: normalization to Al, statistical analysis and sediment quality guidelines (SQGs). The results showed increases in the concentrations of Zn, Ni, Pb, Cd, Cr and Hg, which seemed to be associated with human activities. The levels of Al, Fe and Co probably were associated with crustal material or natural weathering processes. About 45% of the samples presented concentrations exceeding TEL-ERL, levels occasionally associated with adverse biological effects. Four of these samples presented concentrations above PEL-ERM, levels frequently associated with adverse biological effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Estimar o número de trabalhadores brasileiros expostos à sílica no ano de 2001. MÉTODO: Informações sobre ocupações e setores econômicos foram reunidas em uma matriz de exposição ocupacional (MEO) com 347 categorias ocupacionais por 25 subsetores econômicos. Informações sobre o número de trabalhadores por ocupação foram extraídas da base de dados Relatório Anual de Informações Sociais (RAIS) do Ministério do Trabalho e Emprego. A exposição à sílica foi avaliada e classificada por dois peritos em quatro categorias, de acordo com a freqüência semanal de exposição no ambiente de trabalho. RESULTADOS: Foram considerados não expostos 31.451.594 trabalhadores (85,7%), possivelmente expostos 976.939 (2,65%), provavelmente expostos 2.404.955 (6,52%) e definitivamente expostos à sílica 2.065.929 (5,6%). Os setores com a maior prevalência de exposição foram: construção civil 65%, extração de pedras 59%, indústria de mineral não metálico 55% e indústria metalúrgica 24%. No setor de serviços de terceiros, a prevalência foi de 2%. CONCLUSÃO: A prevalência de trabalhadores brasileiros definitivamente expostos à sílica é mais alta do que aquela observada em países europeus, onde estudos semelhantes foram conduzidos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A demanda da sociedade moderna intensificou o trabalho ininterrupto em diversas profissões. Além disso, o modo de organização da sociedade, com atividades predominantemente mecanizadas, tem contribuído para a prevalência de hábitos de vida não saudáveis, como a inatividade física. Este estudo objetiva verificar se fatores ocupacionais, sociodemográficos, antropométricos e alimentares estão associados à prática de atividade física insuficiente e se há diferenças nessa associação entre motoristas de caminhão que trabalham de dia ou à noite. Participaram da pesquisa 470 motoristas de caminhão, que responderam a questionários de dados sociodemográficos, atividade física e frequência alimentar. Foi realizada uma regressão logística univariada para verificar a associação entre atividade física insuficiente e as demais variáveis. Além disso, a regressão logística múltipla foi testada para obter modelos que mostrem a associação de conjuntos de variáveis relacionados à atividade física insuficiente. Os resultados indicaram que a prática de atividade física está associada ao maior nível de escolaridade (OR = 1,84; IC = 1,22-2,76) e menor consumo de bebidas alcoólicas (OR = 1,59; IC = 1,04-2,45). Maior ingestão de cereais integrais (OR = 1,63; IC = 1,08-2,46) foi associada à prática regular de atividade física. Entre os trabalhadores noturnos, foi encontrada associação entre a prática regular de atividade física, maior consumo de cereais integrais (OR = 2,02; IC =1,13-3,60) e menor consumo de carboidratos simples (OR = 1,91; IC = 1,08-3,37).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Estimar a prevalência de distúrbios psíquicos menores e identificar estressores associados entre motoristas de caminhão. MÉTODOS: Estudo transversal conduzido com 460 motoristas de caminhão de uma transportadora de cargas das regiões Sul e Sudeste do Brasil, em 2007. Os trabalhadores preencheram questionário com dados sociodemográficos, estilos de vida e condições de trabalho. As variáveis independentes foram condições de trabalho, incluindo estressores ocupacionais, satisfação e demanda-controle no trabalho. O desfecho avaliado foi a ocorrência de distúrbios psíquicos menores. Foram realizadas análises de regressão logística univariada e múltipla. RESULTADOS: A prevalência de distúrbios psíquicos menores foi de 6,1 por cento. Os estressores mais citados foram congestionamentos, controle de rastreamento e jornada extensa de trabalho. A alta demanda no trabalho, o baixo apoio social e a jornada extensa diária referidos pelos motoristas estiveram associados aos distúrbios psíquicos menores. CONCLUSÕES: O trabalho em jornadas extensas foi associado à ocorrência de distúrbios psíquicos menores, tanto na análise das condições gerais de trabalho quanto como fator referido como estressor pelos motoristas. A regulamentação da jornada de trabalho com limitação de horas de trabalho diário é, portanto, uma medida necessária para a redução da chance de desenvolvimento de distúrbios psíquicos menores em motoristas

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new criterion has been recently proposed combining the topological instability (lambda criterion) and the average electronegativity difference (Delta e) among the elements of an alloy to predict and select new glass-forming compositions. In the present work, this criterion (lambda.Delta e) is applied to the Al-Ni-La and Al-Ni-Gd ternary systems and its predictability is validated using literature data for both systems and additionally, using own experimental data for the Al-La-Ni system. The compositions with a high lambda.Delta e value found in each ternary system exhibit a very good correlation with the glass-forming ability of different alloys as indicated by their supercooled liquid regions (Delta T(x)) and their critical casting thicknesses. In the case of the Al-La-Ni system, the alloy with the largest lambda.Delta e value, La(56)Al(26.5)Ni(17.5), exhibits the highest glass-forming ability verified for this system. Therefore, the combined lambda.Delta e criterion is a simple and efficient tool to select new glass-forming compositions in Al-Ni-RE systems. (C) 2011 American Institute of Physics. [doi: 10.1063/1.3563099]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Currently, the acoustic and nanoindentation techniques are two of the most used techniques for material elastic modulus measurement. In this article fundamental principles and limitations of both techniques are shown and discussed. Last advances in nanoindentation technique are also reviewed. An experimental study in ceramic, metallic, composite and single crystals was also done. Results shown that ultrasonic technique is capable to provide results in agreement with those reported in literature. However, ultrasonic technique does not allow measuring the elastic modulus of some small samples and single crystals. On the other hand, the nanoindentation technique estimates the elastic modulus values in reasonable agreement with those measured by acoustic methods, particularly in amorphous materials, while in some policristaline materials some deviation from expected values was obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Infrared-to-visible and infrared-to-infrared frequency upconversion processes in Yb(3+)-Tm(3+) doped PbO-GeO(2) glasses containing silver nanoparticles (NPs) were investigated. The experiments were performed by exciting the samples with a diode laser operating at 980 nm (in resonance with the Yb(3+) transition (2)F(7/2)->(2)F(5/2)) and observing the photoluminescence (PL) in the visible and infrared regions due to energy transfer from Yb(3+) to Tm(3+) ions followed by excited state absorption in the Tm3+ ions. The intensified local field in the vicinity of the metallic NPs contributes for enhancement in the PL intensity at 480 nm (Tm(3+) :(1)G(4)->(3)H(6)) and at 800 nm (Tm(3+) : (3)H(4) -> (3)H(6)). (C) 2009 American Institute of Physics. [doi:10.1063/1.3211300]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A frequency upconversion process in Pr(3+) doped TeO(2)-ZnO glasses containing silver nanoparticles is studied under excitation with a nanosecond laser operating at 590 nm, in resonance with the (3)H(4)-->(1)D(2) transition. The excited Pr(3+) ions exchange energy in the presence of the nanoparticles, originating efficient conversion from orange to blue. The enhancement in the intensity of the luminescence at similar to 482 nm, corresponding to the (3)P(0)-->(3)H(4) transition, is due to the influence of the large local field on the Pr(3+) ions, which are located near the metallic nanoparticles. (C) 2008 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and Purpose: The right kidney has been less frequently used in live donor nephrectomy, because of the shorter length of the right renal vein (RRV) that is associated with technical difficulties and higher rates of venous thrombosis. In live open donor or deceased donor transplant nephrectomy, an additional cuff of the inferior vena cava is usually removed, but this is a more difficult and risky maneuver in laparoscopic nephrectomy. For this reason, laparoscopic right nephrectomy (LRN) for renal transplantation (RT) is not frequently performed in most medical institutions. We evaluate the difference between RRV and left renal vein (LRV) lengths in cadavers, as harvested for RT by three clamping methods. Our objective was to obtain information that could clarify when LRN for RT should be encouraged or avoided with regard to conventional surgery. Materials and Methods: Ninety adult fresh unfrozen cadavers were randomly divided into three groups of 30, according to the clamping device used: Satinsky, stapler, and Hem-o-lok clip. The abdominal viscera were removed through a median xyphopubic incision, and the veins were measured on the bench. Two lateral limits were used: The renal hilum and the tangential line of the renal poles. As for medial limits, the inferior vena cava or the laparoscopic clipping device on the RRV were used on the right side, while on the LRV, the medial border of the emergence of the adrenal vein was considered. After section of the renal vein, a slight traction of the extremity was applied for the measurement. All measurements were obtained three times using a metallic millimetric ruler, and the arithmetic mean was considered. The chi-square, one-way analysis of variance, and paired t tests were used for statistical analysis. Statistical significance was accepted at P <= 0.05. Results: The groups of cadavers were homogeneous in demographic characteristics. Regardless of the clamping method and considering the useful length of the LRV, the RRV was statistically smaller. The evaluation of the vein length did not depend on the lateral limit considered. Independent of the clamping method, on both sides, the lengths after the vein section were larger than before the section, a fact attributed to traction. Use of a stapler and a single Hem-o-lok presented the same waste of vein length on the right side. On average, the RRV was 13.7% shorter than the LRV. Conclusions: With the wide acceptance of laparoscopic live donor nephrectomy, the length difference between the veins of both kidneys is an important issue, and the right kidney is therefore used less than the left, compared with conventional surgery. This article represents the first step to quantify the anatomic length of renal veins in different situations. Certainly, more imagenologic or surgical studies should be carried out before decisions can be made for better selection of patients for LRN.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We show, using ab initio density functional theory calculations, that Mn dimers adsorbed on graphene nanoribbons (Mn(2)/GNRs) present a magnetic bistability, as does the isolated Mn dimer. Our total energy results indicate that Mn dimers lying along the edge sites of zigzag GNRs represent the most likely configuration. We find that similar to the isolated Mn(2) molecule, the antiferromagnetic coupling represents the ground state for Mn(2)/GNR, and the spin density configuration of the GNR does not play an important role on the net magnetic moment of Mn(2), which makes GNRs an ideal substrate for adsorption of these molecules. The ground state and the excited state configuration of the Mn dimer, viz., low-spin (LS) and high-spin (HS), are maintained in the face of changes in the spin density configuration of the substrate. Here we find that the Mn(2)/GNR systems exhibit a LS <-> HS binary behavior, which can be considered as a useful property in the development of nanomemories based upon metallic clusters. (C) 2011 American Institute of Physics. [doi:10.1063/1.3553849]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We study the transport properties of ultrathin disordered nanowires in the neighborhood of the superconductor-metal quantum phase transition. To this end we combine numerical calculations with analytical strong-disorder renormalization group results. The quantum critical conductivity at zero temperature diverges logarithmically as a function of frequency. In the metallic phase, it obeys activated scaling associated with an infinite-randomness quantum critical point. We extend the scaling theory to higher dimensions and discuss implications for experiments.