73 resultados para indirect quantification
Resumo:
Annatto (AN), a natural food colorant rich in carotenoids, has been reported as being an effective antioxidant, but little is known about its potential chemopreventive properties. In this Study, we evaluated the ability of AN to protect human hepatoma cells (HepG2) from micronucleus (MN) induction against three different mutagens: benzo(a)pyrene (B(a)P), doxorubicin (DXR), and methyl methanesulfonate (MMS). In an attempt to clarify the possible mechanism of anti mutagenicity of AN, three protocols of treatment were applied (pretreatment; simultaneous treatment, and post-treatment with AN following treatment with the mutagens). Also, cells exposed only to AN were assayed for cytotoxicity and mutagenicity. A dosage up to 10 mu g/ml of AN was devoid of mutagenic activity. Protective effects were seen on micronuclei induced by B(a)P and DXR using pre and simultaneous treatment, but AN had no significant effect on MN induction by MMS in any of the protocols. Our results also show that exposure of cells to concentrations of AN higher than 10 mu g/ml decreased cell viability. Taken together, our findings indicate that AN presents antimutagenic activity in vitro, but its protective effect is dependent on the mutagen and on type of treatment suggesting its potential use as a chemopreventive agent. Environ. Mol. Mutagen. 50:808-814, 2009. (C) 2009 Wiley-Liss, Inc.
Resumo:
A global biofuels program will lead to intense pressures on land supply and can increase greenhouse gas emissions from land-use changes. Using linked economic and terrestrial biogeochemistry models, we examined direct and indirect effects of possible land-use changes from an expanded global cellulosic bioenergy program on greenhouse gas emissions over the 21st century. Our model predicts that indirect land use will be responsible for substantially more carbon loss ( up to twice as much) than direct land use; however, because of predicted increases in fertilizer use, nitrous oxide emissions will be more important than carbon losses themselves in terms of warming potential. A global greenhouse gas emissions policy that protects forests and encourages best practices for nitrogen fertilizer use can dramatically reduce emissions associated with biofuels production.
Resumo:
A sensitive and reproducible stir bar-sorptive extraction and high-performance liquid chromatography-UV detection (SBSE/HPLC-UV) method for therapeutic drug monitoring of carbamazepine, carbamazepine-10,11-epoxide, phenytoin and phenobarbital in plasma samples is described and compared with a liquid:liquid extraction (LLE/HPLC-UV) method. Important factors in the optimization of SBSE efficiency such as pH, extraction time and desorption conditions (solvents, mode magnetic stir, mode ultrasonic stir, time and number of steps) assured recoveries ranging from 72 to 86%, except for phenytoin (62%). Separation was obtained using a reverse phase C-18 column with UV detection (210 nm). The mobile phase consisted of water: acetonitrile (78:22, v/v). The SBSE/HPLC-UV method was linear over a working range of 0.08-40.0 mu g mL(-1) for carbamazepine, carbamazepine-10,11-epoxide and phenobarbital and 0.125-40.0 mu g mL(-1) for phenytoin, The intra-assay and inter-assay precision and accuracy were studied at three concentrations (1.0, 4.0 and 20.0 mu g mL(-1)). The intra-assay coefficients of variation (CVs) for all compounds were less than 8.8% and all inter-CVs were less than 10%. Limits of quantification were 0.08 mu g mL(-1) for carbamazepine, carbamazepine-10,11-epoxide and phenobarbital and 0.125 mu g mL(-1) for phenytoin. No interference of the drugs normally associated with antiepileptic drugs was observed. Based on figures of merit results, the SBSE/HPLC-UV proved adequate for antiepileptic drugs analyses from therapeutic levels. This method was successfully applied to the analysis of real samples and was as effective as the LLE/HPLC-UV method. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
Techniques applying digital images increasingly have been used in biology, medicine, physics, and other research areas. The image coordinates can represent light intensities values to be detected by a CCD. Based on this concept, a photometric system composed of a LED source and a digital camera as a detector was used for optical density measurements. Standards for permanganate, glucose, and protein solutions were detemined by colorimetric methods using our device. Samples of protein of Pasteurella mutocida bacteria membrane and, also, fractions of rabbit kidney membrane, rich in Na, K-ATPase, with unknown concentrations were dosed through the Hartree method using our photometric system.
Resumo:
This paper examines the syntax of indirect objects (IO) in Brazilian Portuguese (BP). Adopting a comparative perspective we propose that BP differs from European Portuguese (EP) in the grammatical encoding of IO. In EP ditransitive contexts, IO is found in two configurations - one projected by a (low) applicative head and another one involving a lexical/true preposition. We propose that the former property is contingent upon the presence of dative Case marking: namely, the morpheme `a` that introduces IO (a-DP), whose corresponding clitic pronoun is `lhe/lhes`. In contrast, important changes in the pronominal system, coupled with the increase in the use of the preposition `para` are taken as evidence for the loss of the low applicative construction in BP. Thus only the configuration with the lexical/true preposition is found in (Standard) BP. We argue that the innovative properties of IO in BP are due to the loss of the (3rd person) dative clitic and the preposition `a` as dative Case markers. Under this view, we further account for the realization of IO as a DP/weak pronoun, found in dialects of the central region of Brazil, which points to a similarity with the English Double Object Construction. Finally we show that the connection between the morphological expression of the dative Case and the expression of parameters supports a view of syntactic change according to which parametric variation is determined in the lexicon, in terms of the formal features of functional heads.
Resumo:
Objectives We sought to determine whether the quantitative assessment of myocardial fibrosis (MF), either by histopathology or by contrast-enhanced magnetic resonance imaging (ce-MRI), could help predict long-term survival after aortic valve replacement. Background Severe aortic valve disease is characterized by progressive accumulation of interstitial MF. Methods Fifty-four patients scheduled to undergo aortic valve replacement were examined by ce-MRI. Delayed-enhanced images were used for the quantitative assessment of MF. In addition, interstitial MF was quantified by histological analysis of myocardial samples obtained during open-heart surgery and stained with picrosirius red. The ce-MRI study was repeated 27 +/- 22 months after surgery to assess left ventricular functional improvement, and all patients were followed for 52 +/- 17 months to evaluate long-term survival. Results There was a good correlation between the amount of MF measured by histopathology and by ce-MRI (r = 0.69, p < 0.001). In addition, the amount of MF demonstrated a significant inverse correlation with the degree of left ventricular functional improvement after surgery (r = -0.42, p = 0.04 for histopathology; r = -0.47, p = 0.02 for ce-MRI). Kaplan-Meier analyses revealed that higher degrees of MF accumulation were associated with worse long-term survival (chi-square = 6.32, p = 0.01 for histopathology; chi-square = 5.85, p = 0.02 for ce-MRI). On multivariate Cox regression analyses, patient age and the amount of MF were found to be independent predictors of all-cause mortality. Conclusions The amount of MF, either by histopathology or by ce-MRI, is associated with the degree of left ventricular functional improvement and all-cause mortality late after aortic valve replacement in patients with severe aortic valve disease. (J Am Coll Cardiol 2010; 56: 278-87) (c) 2010 by the American College of Cardiology Foundation
Resumo:
Introduction: Prune belly syndrome (PBS) presents with large-capacity bladders, high compliance and post-void residual volumes. Operative and conservative treatments are controversial. When histologically compared to normal bladder, bladder outlet obstruction results in an up- or down-regulation of adrenoceptors. Our goal was to study the immunoexpression of adrenoceptors in detrusor from patients with PBS. Materials and methods: Bladder domes from PBS patients (n = 14) were studied (PBG). For normal controls, bladder specimens were obtained at adult surgery (n = 13) (CG1) and at child autopsy (n = 5) (CG2). Staining was performed using antibodies to alpha 1a, alpha 1b, alpha 1d and beta 3 adrenoceptors. Five to 10 images were captured on an optic microscope with a digital camera and analysed with Photoshop(R). The immunocyhistochemical index with arbitrary units was calculated and compared. Results: Mean age was 1.28, 64 and 1.41 years for PBG, CG1 and CG2, respectively. The immunohistochemical index with arbitrary units of alpha 1a receptors was 0.06 in PBG, 0.16 in CG1 and 0.14 in CG2 (p = 0.008); of alpha 1b 0.06, 0.06 and 0.07 (p = 0.781); and of alpha 1d 0.04, 0.04 and 0.05 (p = 0.618). Regarding beta 3 the respective values were 0.07, 0.14 and 0.10 (p = 0.378). Conclusion: Our results show a decrease in ala-adrenoceptor immunostaining intensity in detrusor from children with PBS. Further in vitro studies are needed to determine whether these observations are physiologically significant. (C) 2009 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Resumo:
Clinical applications of quantitative computed tomography (qCT) in patients with pulmonary opacifications are hindered by the radiation exposure and by the arduous manual image processing. We hypothesized that extrapolation from only ten thoracic CT sections will provide reliable information on the aeration of the entire lung. CTs of 72 patients with normal and 85 patients with opacified lungs were studied retrospectively. Volumes and masses of the lung and its differently aerated compartments were obtained from all CT sections. Then only the most cranial and caudal sections and a further eight evenly spaced sections between them were selected. The results from these ten sections were extrapolated to the entire lung. The agreement between both methods was assessed with Bland-Altman plots. Median (range) total lung volume and mass were 3,738 (1,311-6,768) ml and 957 (545-3,019) g, the corresponding bias (limits of agreement) were 26 (-42 to 95) ml and 8 (-21 to 38) g, respectively. The median volumes (range) of differently aerated compartments (percentage of total lung volume) were 1 (0-54)% for the nonaerated, 5 (1-44)% for the poorly aerated, 85 (28-98)% for the normally aerated, and 4 (0-48)% for the hyperaerated subvolume. The agreement between the extrapolated results and those from all CT sections was excellent. All bias values were below 1% of the total lung volume or mass, the limits of agreement never exceeded +/- 2%. The extrapolation method can reduce radiation exposure and shorten the time required for qCT analysis of lung aeration.
Resumo:
Background: Color Doppler myocardial imaging (CDMI) allows the calculation of local longitudinal or radial strain rate (SR) and strain (epsilon). The aims of this study were to determine the feasibility and reproducibility of longitudinal and radial SR and epsilon in neonates during the first hours of life and to establish reference values. Methods: Data were obtained from 55 healthy neonates (29 male; mean age, 20 +/- 14 hours; mean birth weight, 3,174 +/- 374 g). Apical and parasternal views quantified regional longitudinal and radial SR and epsilon in differing ventricular wall segments. Values at peak systole, early diastole, and late diastole were calculated from the extracted curves. CDMI data acquired at 300 +/- 50 frames/s were analyzed offline. Three consecutive cardiac cycles were measured during normal respiration. The timing of specific systolic or diastolic regional events was determined. Multiple comparisons between walls and segments were made. Results: Left ventricular (LV) longitudinal deformation showed basal differences compared with apical segments within one specific wall. Right ventricular (RV) longitudinal deformation was not homogeneous, with significant differences between basal and apical segments. Longitudinal 3 values were higher in the RV free basal and middle wall segments compared with the left ventricle. In the RV free wall apical segment, longitudinal SR and 3 were maximal. LV systolic SR and epsilon values were higher radially compared with longitudinally (radial peak systolic SR midportion, 2.9 +/- 0.6 s(-1); radial peak systolic epsilon 53.8 +/- 19%; longitudinal peak systolic SR midportion, -1.8 +/- 0.5 s(-1); longitudinal peak systolic epsilon, -24.8 +/- 3%; P < .01). Longitudinal systolic epsilon and SR interobserver variability values were 1.2% and 0.7%, respectively. Conclusion: Ultrasound-based SR and 3 imaging is a practical and reproducible clinical technique in neonates, allowing the calculation of regional longitudinal and radial deformation in RV and LV segments. These regional SR and epsilon indices represent new, noninvasive parameters that can quantify normal neonate regional cardiac function. Independent from visual interpretation, they can be used as reference values for diagnosis in ill neonates. (J Am Soc Echocardiogr 2009;22:369-375.)
Resumo:
Radiation dose calculations in nuclear medicine depend on quantification of activity via planar and/or tomographic imaging methods. However, both methods have inherent limitations, and the accuracy of activity estimates varies with object size, background levels, and other variables. The goal of this study was to evaluate the limitations of quantitative imaging with planar and single photon emission computed tomography (SPECT) approaches, with a focus on activity quantification for use in calculating absorbed dose estimates for normal organs and tumors. To do this we studied a series of phantoms of varying complexity of geometry, with three radionuclides whose decay schemes varied from simple to complex. Four aqueous concentrations of (99m)Tc, (131)I, and (111)In (74, 185, 370, and 740 kBq mL(-1)) were placed in spheres of four different sizes in a water-filled phantom, with three different levels of activity in the surrounding water. Planar and SPECT images of the phantoms were obtained on a modern SPECT/computed tomography (CT) system. These radionuclides and concentration/background studies were repeated using a cardiac phantom and a modified torso phantom with liver and ""tumor"" regions containing the radionuclide concentrations and with the same varying background levels. Planar quantification was performed using the geometric mean approach, with attenuation correction (AC), and with and without scatter corrections (SC and NSC). SPECT images were reconstructed using attenuation maps (AM) for AC; scatter windows were used to perform SC during image reconstruction. For spherical sources with corrected data, good accuracy was observed (generally within +/- 10% of known values) for the largest sphere (11.5 mL) and for both planar and SPECT methods with (99m)Tc and (131)I, but were poorest and deviated from known values for smaller objects, most notably for (111)In. SPECT quantification was affected by the partial volume effect in smaller objects and generally showed larger errors than the planar results in these cases for all radionuclides. For the cardiac phantom, results were the most accurate of all of the experiments for all radionuclides. Background subtraction was an important factor influencing these results. The contribution of scattered photons was important in quantification with (131)I; if scatter was not accounted for, activity tended to be overestimated using planar quantification methods. For the torso phantom experiments, results show a clear underestimation of activity when compared to previous experiment with spherical sources for all radionuclides. Despite some variations that were observed as the level of background increased, the SPECT results were more consistent across different activity concentrations. Planar or SPECT quantification on state-of-the-art gamma cameras with appropriate quantitative processing can provide accuracies of better than 10% for large objects and modest target-to-background concentrations; however when smaller objects are used, in the presence of higher background, and for nuclides with more complex decay schemes, SPECT quantification methods generally produce better results. Health Phys. 99(5):688-701; 2010
Resumo:
Universidade de São Paulo - LIM[40/HC-FM-USP]
Using BCG, MPT-51 and Ag85 as antigens in an indirect ELISA for the diagnosis of bovine tuberculosis
Resumo:
This study evaluated the Mycobacterium tuberculosis protein antigen MPT-51, the trimeric antigen 85 (Ag85) complex, and Bacillus Calmette-Guerin (BCG) in an indirect ELISA to diagnose bovine tuberculosis (TB) from serum samples. Serum was collected from 208 intra-dermal tuberculin test (ITT)-positive and 54 ITT-negative animals from a region where bovine TB is endemic. Using the Ag85 and BCG antigens, the indirect ELISA was able to discriminate ITT-positive from ITT-negative animals. This level of discrimination was not achieved when using the MPT-51 antigen. The highest sensitivity (Se) and specificity (Sp) of the test was found when BCG was used (Se, 82%; Sp, 91%). Further work in different epidemiological settings and with larger numbers of animals will be required to validate these findings. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Gene amplification occurs in Bradysia hygida salivary glands, at the end of the fourth larval instar. The hormone 20-hydroxyecdysone (20E) triggers this process, which results in DNA puff formation. Amplified genes are activated in two distinct groups. The activity of the first group is dependent on high levels of 20E, while the second group needs low hormone levels. Consequently, the salivary glands of B. hygida constitute an interesting biological model to study how 20E, and its receptors, affect gene amplification and activity. We produced polyclonal antibodies against B. hygida EcR (BhEcR). In western blots a polypeptide of about 66 kDa was detected in salivary gland extracts. The antibodies were also used for indirect immune-localization of BhEcR in polytene chromosomes. RNA-polymerase II was also immune-detected. We did not detect the receptor in chromosome C where the first and second groups of DNA puffs form during DNA puff anlage formation, but it was present during puff expansion. During the active phase of both groups of DNA puffs, RNA polymerase II co-localized with BhEcR. After puff regression, these antigens were not detected. Apparently, EcR plays a direct role in the transcription of amplified genes, but its role in gene amplification remains enigmatic.
Resumo:
Purpose: The aim of this study was to compare the measured energy expenditure (EE) and the estimated basal EE (BEE) in critically ill patients. Materials and Methods: Seventeen patients from an intensive care unit were randomly evaluated. Indirect calorimetry was performed to calculate patient`s EE, and BEE was estimated by the Harris-Benedict formula. The metabolic state (EE/BEE x 100) was determined according to the following criteria: hypermetabolism, more than 130%; normal metabolism, between 90% and 130%; and hypometabolism, less than 90%. To determine the limits of agreement between EE and BEE, we performed a Bland-Altman analysis. Results: The average EE of patients was 6339 +/- 1119 kJ/d. Two patients were hypermetabolic (11.8%), 4 were hypometabolic (23.5%), and 11 normometabolic (64.7%). Bland-Altman analysis showed a mean of -126 +/- 2135 kJ/d for EE and BEE. Only one patient was outside the limits of agreement between the 2 methods (indirect calorimetry and Harris-Benedict). Conclusions: The calculation of energy needs can be done with the equation of Harris-Benedict associated with lower values of correction factors (approximately 10%) to avoid overfeeding, with constant monitoring of anthropometric and biochemical parameters to assess the nutritional changing and adjust the infusion of energy. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Hemophilia A is an X-linked, inherited, bleeding disorder caused by the partial or total inactivity of the coagulation factor VIII (FVIII). Due to difficulties in the direct recognition of the disease-associated mutation in the F8 gene, indirect diagnosis using polymorphic markers located inside or close to the gene is used as an alternative for determining the segregation of the mutant gene within families and thus for detecting carrier individuals and/or assisting in prenatal diagnosis. This study characterizes the allelic and haplotype frequencies, genetic diversity, population differentiation and linkage disequilibrium of five microsatellites (F8Int1, F8Int13, F8Int22, F8Int25.3 and IKBKG) in samples of healthy individuals from Sao Paulo, Rio Grande do Sul and Pernambuco and of patients from Sao Paulo with haemophilia A to determine the degree of informativeness of these microsatellites for diagnostic purposes. The interpopulational diversity parameters highlight the differences among the analyzed population samples. Regional differences in allelic frequencies must be taken into account when conducting indirect diagnosis of haemophilia A. With the exception of IKBKG, all of the microsatellites presented high heterozygosity levels. Using the markers described, diagnosis was possible in 10 of 11 families. The F8Int22, F8Int1, F8Int13, F8Int25.3 and IKBKG microsatellites were informative in seven, six, five and two of the cases, respectively, demonstrating the effectiveness of using these microsatellites in prenatal diagnosis and in carrier identification in the Brazilian population.