44 resultados para i d farmacéutico
Resumo:
Titanium oxide (TiO(2)) has been extensively applied in the medical area due to its proved biocompatibility with human cells [1]. This work presents the characterization of titanium oxide thin films as a potential dielectric to be applied in ion sensitive field-effect transistors. The films were obtained by rapid thermal oxidation and annealing (at 300, 600, 960 and 1200 degrees C) of thin titanium films of different thicknesses (5 nm, 10 nm and 20 nm) deposited by e-beam evaporation on silicon wafers. These films were analyzed as-deposited and after annealing in forming gas for 25 min by Ellipsometry, Fourier Transform Infrared Spectroscopy (FTIR), Raman Spectroscopy (RAMAN), Atomic Force Microscopy (AFM), Rutherford Backscattering Spectroscopy (RBS) and Ti-K edge X-ray Absorption Near Edge Structure (XANES). Thin film thickness, roughness, surface grain sizes, refractive indexes and oxygen concentration depend on the oxidation and annealing temperature. Structural characterization showed mainly presence of the crystalline rutile phase, however, other oxides such Ti(2)O(3), an interfacial SiO(2) layer between the dielectric and the substrate and the anatase crystalline phase of TiO(2) films were also identified. Electrical characteristics were obtained by means of I-V and C-V measured curves of Al/Si/TiO(x)/Al capacitors. These curves showed that the films had high dielectric constants between 12 and 33, interface charge density of about 10(10)/cm(2) and leakage current density between 1 and 10(-4) A/cm(2). Field-effect transistors were fabricated in order to analyze I(D) x V(DS) and log I(D) x Bias curves. Early voltage value of -1629 V, R(OUT) value of 215 M Omega and slope of 100 mV/dec were determined for the 20 nm TiO(x) film thermally treated at 960 degrees C. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The effect of sewage sludge (SS) amendment on the general properties of the top layers of a sandy and a clayey oxisols and on the nature of their humic acid (HA) fractions was evaluated by chemical and physico-chemical techniques. The amended soils, especially the sandy soil, benefited of SS amendment by increasing their pH to above neutrality and enhancing the contents of C, N, P, and Ca and cation exchange capacity. The SS-HA-like sample showed larger H and N contents and a greater aliphatic character and humification degree than the HAs isolated from non-amerided soils. The composition and structure of amended soil HAs were affected by SS application as a function of soil type and layer. In particular, N-containing groups and aliphatic structures of SS-HA-like sample appears to be partially incorporated in the amended soil HAs, and these effects were more evident in the HAs from the sandy oxisol. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
New fast liquid chromatographic and capillary zone electrophoresis methods were developed and validated for simultaneous determination of atenolol and chlortalidone in combined dose tablets. The reversed phase HPLC method was carried out on a CN LiChrosorb (R) (125 x 4 mm, 5 mu m) column. The CZE method was carried out on an uncoated fused-silica capillary of 30 cm x 75 mu m i.d. with 25 mmol L(-1) sodium tetraborate, pH 9.4. The total analysis time was <6 and <2.5 min for HPLC and CZE methods, respectively. Both methods can be used for stability studies as well.
Resumo:
A reversed-phase high performance liquid chromatographic (RP-HPLC) method for determination of econazole nitrate, preservatives (methylparaben and propylparaben) and its main impurities (4-chlorobenzl alcohol and alpha-(2,4-dicholorophenyl)-1H-imidazole-1-ethanol) in cream formulations, has been developed and validated. Separation was achieved on a column Bondclone (R) C18 (300 mm x 3.9 mm i.d., 10 mu m) using a gradient method with mobile phase composed of methanol and water. The flow rate was 1.4 mL min(-1), temperature of the column was 25 C and the detection was made at 220 nm. Miconazole nitrate was used as an internal standard. The total run time was less than 15 min, The analytical curves presented coefficient of correlation upper to 0.99 and detection and quantitation limits were calculated for all molecules. Excellent accuracy and precision were obtained for econazole nitrate. Recoveries varied from 97.9 to 102.3% and intra- and inter-day precisions, calculated as relative standard deviation (R.S.D), were lower than 2.2%. Specificity, robustness and assay for econazole nitrate were also determined. The method allowed the quantitative determination of econazole nitrate, its impurities and preservatives and could be applied as a stability-indicating method for econazole nitrate in cream formulations. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
The aim of this study was to develop and validate selective and sensitive methods for quantitative determination of an antibacterial agent, gemifloxacin, in tablets by high performance liquid chromatography (HPLC) and capillary zone electrophoresis (CZE). The HPLC method was carried out on a LiChrospher (R) 100 RP-8e, 5 mu m (125 x 4 mm) column with a mobile phase composed of tetrahydrofuran-water (25:75, v/v) with 0.5 % of triethylamine and pH adjusted to 3.0 with orthophosphoric acid. The CZE method was performed using 50 mM sodium tetraborate buffer (pH 8.6). Samples were injected hydrodynamicaly (0.5 psi, 5 s) and the electrophoretic system was operated under normal polarity, at +20 kV and capillary temperature of 18 degrees C. A fused-silica capillary 40.2 cm (30 cm effective length) x 75 mu m i.d. was used. Both, HPLC and CZE could be interesting and efficient techniques to be applied for quality control in pharmaceutical industries.
Resumo:
A simple, fast, inexpensive and reliable capillary zone electrophoresis (CZE) method for the determination of econazole nitrate in cream formulations has been developed and validated. Optimum conditions comprised a pH 2.5 phosphate buffer at 20 mmol L(-1) concentration, +30 kV applied voltage in a 31.5 cm x 50 mu m I.D. capillary. Direct UV detection at 200 nm led to an adequate sensitivity without interference from sample excipients. A single extraction step of the cream sample in hydrochloric acid was performed prior to injection. Imidazole (100 mu g mL(-1)) was used as internal standard. Econazole nitrate migrates in approximately 1.2 min. The analytical curve presented a coefficient of correlation of 0.9995. Detection and quantitation limits were 1.85 and 5.62 mu g mL(-1), respectively. Excellent accuracy and precision were obtained. Recoveries varied from 98.1 to 102.5% and intra- and inter-day precisions, calculated as relative standard deviation (RSD), were better than 2.0%. The proposed CZE method presented advantageous performance characteristics and it can be considered suitable for the quality control of econazole nitrate cream formulations. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
Vecuronium bromide is a neuromuscular blocking agent used for anesthesia to induce skeletal muscle relaxation. HPLC and CZE analytical methods were developed and validated for the quantitative determination of vecuronium bromide. The HPLC method was achieved on an amino column (Luna 150 x 4.6 mm, 5 mu m) using UV detection at 205 nm. The mobile phase was composed of acetonitrile:water containing 25.0 mmol L(-1) of sodium phosphate monobasic (50:50 v/v), pH 4.6 and flow rate of 1.0 mL min(-1). The CZE method was achieved on an uncoated fused-silica capillary (40.0 cm total length, 31.5 cm effective length and 50 mu m i.d.) using indirect UV detection at 230 nm. The electrolyte comprised 1.0 mmol L(-1) of quinine sulfate dihydrate at pH 3.3 and 8.0% of acetonitrile. The results were used to compare both techniques. No significant differences were observed (p > 0.05).
Resumo:
In the present study a fast, sensitive and robust validated method to quantify chlorpheniramine in human plasma using brompheniramine as internal standard (IS) is described. The analyte and the IS were extracted from plasma by LLE (diethyl ether-dichloromethane, 80:20, v/v) and analyzed by HPLC-ESI-MS/MS. Chromatographic separation was performed using a gradient of methanol from 35 to 90% with 2.5 mm NH(4)OH on a Gemini Phenomenex C(8) 5 mu m column (50 x 4.6 mm i.d.) in 5.0 min/run. The method fitted to a linear calibration curve (0.05-10 ng/mL, R > 0.9991). The precision (%CV) and accuracy ranged, respectively: intra-batch from 1.5 to 6.8% and 99.1 to 106.6%, and inter-batch from 2.4 to 9.0%, and 99.9 to 103.1%. The validated bioanalytical procedure was used to assess the comparative bioavailability in healthy volunteers of two dexchlorpheniramine 2.0 mg tablet formulations (test dexchlorpheniramine, Eurofarma, and reference Celestamine (R), Schering-Plough). The study was conducted using an open, randomized, two-period crossover design with a 2 week washout interval. Since the 90% confidence interval for C(max) and AUC ratios were all within the 80-125% interval proposed by ANVISA and FDA, it was concluded that test and reference formulations are bioequivalent concerning the rate and the extent of absorption. Copyright (C) 2009 John Wiley & Sons, Ltd.
Resumo:
The diagnosis of a catecholamine-secreting pheochromocytoma is always suggested by occurrence of severe and symptomatic paroxysmal hypertension. However, in most patients this diagnosis is not confirmed, despite extensive investigation.(1) Traditionally, besides pheochromocytoma, the differential diagnosis in cases of paroxysmal hypertension associated with catecholamine excess should include cocaine use, antiparkinsonian drugs, obstructive sleep apnoea and baroreflex failure.(2) Nonetheless, when the paroxysmal hypertension is associated not only with catecholamine excess, but also with neurologic signs, a very rare differential diagnosis should also be considered: a brainstem tumour mimicking pheochromocytoma.(3-5)
Resumo:
Objective To evaluate the influence of CYP17 polymorphism on menopausal symptoms after estrogen treatment. Methods A total of 130 women were recruited, but only 100 of these were selected according to inclusion and exclusion criteria; they were treated with 0.3 mg/day conjugated equine estrogens. One year later, the study was completed by 71 women. The analysis of the Kupperman menopausal index symptoms was made with information provided by the patients on daily diary cards. Blood samples were analyzed and the women were divided into two groups based on the CYP17, 5`-untranslated region: group A (wild-type homozygote and heterozygote) and group B (mutated homozygote). Results The values for the Kupperman menopausal index were similar in both groups at baseline. The symptoms in both groups decreased after 1 year of treatment when compared to those at baseline. The improvement rate was approximately 27.09% and 32.18%, in groups A and B, respectively. The levels of estrogen after treatment were higher in both groups in comparison with the baseline values. The testosterone level rose in group B with the 1-year treatment (0.48 +/- 0.16 ng/ml), reaching a higher level than the level in group A after treatment. The sex hormone binding globulin (SHBG) level showed a significant increase after the 1-year treatment in group B, surpassing both the baseline and the after-treatment values in group A (p < 0.01). Conclusion Our data suggest that the CYP17 polymorphism did not influence the action of estrogen on menopause symptoms during the 1-year treatment. The extra production of estrogen and androgen may have been countered by the elevation of SHBG levels.
Resumo:
Objective To investigate the association between the CYP17 alpha gene polymorphism and hot flushes in postmenopausal women. Methods Ninety-three non-hysterectomized, postmenopausal women were enrolled in this study. Vasomotor symptoms were assessed at the baseline visit and based on information provided by each participant. The genotypic polymorphism of CYP17 alpha gene was analyzed by PCR-RFLP assay using genomic DNA isolated from peripheral blood lymphocytes. Results Thirty-six women reported hot flushes of mild intensity, 25 reported hot flushes of moderate intensity and 32 of severe intensity. There was no significant difference between the severity of hot flushes and the CYP17 genotype or allele frequencies, 0.58 and 0.67 respectively. No association was found between hot flush severity and the CYP17 allele (odds ratio = 1.17, p = 0.61). Conclusion The results of this study suggest that the CYP17 MspAI polymorphism was not significantly associated with an increased risk of reporting hot flushes. At the World Congress on Menopause in Madrid, May 2008, Dr Massad-Costa was awarded the Robert Greenblatt Prize for Basic Science for the study reported in this paper.
Resumo:
Introduction: Some studies have made use of the antioxidative capabilities of high doses of vitamins C and E with the aim of neutralizing the noxious effects of free radicals following spinal cord lesion. Objectives: To evaluate the effects of vitamins C and E, separately and together, on the functional performance of rats that were subjected to standardized spinal cord contusion. Materials and methods: Forty male Wistar rats were used, divided into four groups of 10 animals each. Group 3 received vitamin C 100 mg kg(-1) day(-1) intraperitoneally; Group 2 received vitamin E 100 mg kg(-1) day(-1) orally; Group 1 received vitamins C and E, at the same dosages; and Group 4 was the control. The vitamin therapy was administered for 1 month and then the animals were killed. A direct contusional injury was caused and functional evaluation was performed using the Basso, Beattie and Bresnahan rating scale. The rats were evaluated on the second postoperative day and weekly thereafter, until the end of the experiment. Results: The results were evaluated by means of the one-tailed, non-paired and non-parametric Mann-Whitney test, comparing the groups two by two. No significant difference in functional performance was observed between the groups. Conclusion: The use of vitamins C and E in these rats did not improve their neurological performance. However, histopathological examination showed that the inflammatory response was less intense following administration of the combination of vitamins C and E. Spinal Cord (2009) 47, 458-463; doi:10.1038/sc.2008.155; published online 9 December 2008
Resumo:
Objectives: Depression and dementia are highly prevalent in the elderly. Language impairment is an inherent component of Alzheimer`s disease (AD), which can also be encountered in depressed patients. The aim of this study wasto compare the profiles of language abilities in late-onset depression and mild AD groups. Methods: We studied 25 patients with late-onset depression (mean age 73.6 +/- 6.6 years; schooling 9.1 +/- 5.7 years) and 30 patients with mild AD (77.6 +/- 5.4 years; 7.5 +/- 7.1 years) using the Arizona Battery for Communication Disorders of Dementia (ABCD), compared to a group of 30 controls (73.8 +/- 5.8 years; 9.1 +/- 5.4 years). Cut-off scores to discriminate between Controls x Depression and Depression x AD were determined. Results: Depressed patients` scores were similar to AD in confrontation naming, concept definition, following commands, repetition and reading comprehension (sentence). Episodic memory and mental status subtests were useful in differentiating depressed patients from AD, a result that was reproduced when using analysis of covariance to control for the effect of age in the same subtests (p = 0.01 and 0.04, respectively). Conclusion: Language impairment resembling AD was found in the aforementioned language subtests of the ABCD in elderly depressed patients; the mental status and episodic memory subtests were useful to discriminate between AD and depression. The ABCD has proven to be a suitable tool for language evaluation in this population and should aid in the differentiation of AD and pseudodementia (as that of depression).
Resumo:
Background: We report the validation of a method for the determination of acetaldehyde, acetone, methanol, and ethanol in biological fluids using manual headspace sample introduction and an acetonitrile internal standard. Method: This method uses a capillary column (I = 30 m, I.D. = 0.25 mm, dF = 0.25 mu m) installed in a gas chromatography-flame ionization detector (GC-FID) apparatus with a run time of 7.5 minutes. Results: Analysis of the retention times and the resolution of the analyte peaks demonstrated excellent separation without widening of the peaks. Precision and accuracy were good (interassay precision < 15% and recovery between 85% and 115%) in both blood and urine. Conclusion: The method was linear (r > 0.09) over the analytical measurement range (AMR) of each analyte.